FLOW Measurement for Tanker Vehicles

Similar documents
VEGA II. Electronic counter. The solutions that count

NF760 Batch Controller

NF770 Temperature Compensation Liquid Flow Computer

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Oil & Gas. Control Control. every move. Pressure Temperature Level Flow

Flexible temperature transmitter and sensor

Masterload II electronic meter controller for aircraft refuelling vehicles

Ink supply systems for the graphics industry

Springfield Product Portfolio

Overfill Prevention Controller EUS-2

EC 600 Electronic Volume Corrector

Universal IV Water Cut Meter

Temperature sensors TTM series. Miniature transmitters

HPM Series - Sensor Recognition

Temperature dry-well calibrator Models CTD , CTD

The SF-586b Insertion Flow Meter For Compressed Air, Gases And Exhaust Air (up to 400 C) In Pipe Diameters From 25mm to 5000mm

Dual differential pressure sensor For ventilation and air-conditioning Model A2G-52

ME6008M Batch Monitor Printer Driver Unit

Humidity + Temp. + Dew Point Pocket size HUMIDITY METER. Model : HT-315

How to build a Conductivity Measurement System

MBS1250 Heavy Duty Pressure Transmitter. Product Electrical Installation

Yokogawa Y-Flow Master Database 62102

Flow Computer compart DXF 351. Universal Application for Gas, Steam and Liquids

METER REGISTER & DATA CONTROLLER

Differential pressure sensor For ventilation and air-conditioning Model A2G-50

HygroPalm 0. Portable Humidity Temperature Indicator. Instruction Manual

XRC G Panel Mount XSeries G4 Products Remote Controller

Versatile Transmitter Series For Intelligent Measurement Solutions. INGOLD Leading Process Analytics

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas

SWING Ultrasonic Level & Flow Controller

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

Range. Body Material. Max. Press ms K=0, C 4 bar Glass Graphite 13.5 PG Full integrated 5-meter cable

ASM Series. Advanced Signal Multi-scanner. Functional signal multi-scanner adding flexibility to your calibration needs

Dräger Polytron 8200 Stationary gas detector (CatEx)

Flow VA 500/

Level Plus. Liquid-Level Sensors With Temposonics Technology. Accessories Catalog

MAJOR INSTRUMENTS. Oval Gear Positive Displacement Flow Meter

MID approval no. DE-08-MI004-PTB004 Date of release

Smart Energy & Power Quality Solutions. ProData datalogger. Datalogger and Gateway

TORRIX M12. Technical Documentation. TORRIX Configuration Tool. Edition: Version: 1 Article no.:

Precision thermometer Model CTR2000

OPTIFLEX 1100 C Technical Datasheet

Sensor for car parks and tunnels

OPERATION MANUAL MODEL TT-LP

DCT7088 Portable Digital Correlation Transit Time Flowmeter

Dynamic Flow Computers, Inc Southwest Freeway, Suite 320 Stafford, TX Ph: (281) Fax: (281)

Ultrasonic Flow Meter Brochure

MANOMETER OPERATION MANUAL. 200 mbar, differential input. Model : PM-9102

Digital Indicator Solutions

Heat Value Gas Chromatograph ISO standard version

VACUUM METER Model : VC-9200

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

T 9510 EN Media 7 Differential Pressure Meter with remote data transmission

MCG 1500SFI. MCG 1500SFI Smart Flash Infrared Servo Gauge. Features. Smart Flash Infrared Servo Gauge

16 pools with just one central unit with ProMinent The new swimming pool controller DULCOMARIN II

METER Ultrasonic level transmitter

Installation Manual Series PQ-L. Electronic Module. Bulletin /UK

MANOMETER OPERATION MANUAL mbar, differential input. Model : PM-9107

TEMPRO Mold Temperature Controllers

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

EXD-TEVI Economizer Controller for Tandem Compressors

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Industrial Wet/Wet Differential Pressure Transducer

Pneumatic precision pressure controller Model CPC6000

Flow. Order number VA 550. Order no. VA 570. Further accessories A_...M_

CODUCTIVITY METER OPERATION MANUAL. Model : CD-4303

APPLICATIONS. Boiler / Burners Turbines Engines Incinerators Process Control Landfills Cogeneration plants

CALEC energy master The benchmark in energy measurement

Operating Instructions for Level Switch for Liquids. Model: RFS

LAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER

Self-Powered Wireless Instrumentation

SX 6000 Paperless Recorder

Flow Computer. FloWEB

Overfill Prevention Controller EUS-2

TEMPERATURE CALIBRATOR TC305

Series DMHF Heat Meter

Model T3000 Resistance Temperature Transmitters

DIAGNOSTICS PN# / / FSP

CoriolisMaster Accurate flow measurement of liquids and gases

ALIBRATORS. Portable Calibrators Product Guide. Pressure, temperature, electrical and frequency. Compact and rugged design

Datasheet DE DB_EN_DE45_LCD Rev. ST4-G 11/17. Digital differential pressure switch / transmitter with colour-change LCD * *

Family of Water Cut Analyzers

Operating Instructions for Digital Thermometers. Model: DTM

Operating Instructions VEGAMET 381

SwirlMaster The new generation of swirl flowmeters

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

Temperature dry-well calibrator Models CTD9100-COOL, CTD , CTD , CTD

INSTRUCTION MANUAL FOR TQ-8800 TORQUE METER PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Data sheet deltwavec-f

Sensors with analog output

Thermal Mass Flowmeter Sensyflow FMT200-D

LiquiDens. SensoTech. Process density meter for liquids Product description

Conductivity Transmitters

Controllers. Metal Finishing. and Surface Treatment

Model 332 Differential Pressure Transmitter

Automation System TROVIS 5400 District Heating Controller TROVIS 5476

DATASHEET ULTRASONIC COMPACT ENERGY METER MODEL 773

Smith Meter ETR-1000 Electronic Register

WTX120. Legal-for-trade industrial weighing terminal. Special features. Data sheet

Scanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A

Transcription:

11/03 FLOW Measurement for Tanker Vehicles for Propane & Butane Flow Instruments & Engineering GmbH Heiligenstock 34 c-f D-42 697 Solingen Postfach 11 03 25 D-42 663 Solingen Tel.: 00 49 (0)2 12-70 05-0 Fax: 0049(0)212-70 0555 www.flow-instruments.de - sales@flow-instruments.de

S ince 1981 Flow Instruments has been any ancillary equipment such as a laptop or successfully designing and manufacturing handheld computer. While the flow processor is flow meter systems for cryogenic liquids as well as being configured, help information as well as carbondioxide, nitrousoxide and LNG. In 2001 minimum and maximum values are displayed for Flow introduced its first flow meter for propane- each parameter individually. The four push buttons butane and obtained approval from PTB. The of the flow meter are labeled on the display above latest addition to the flowcom product line, the and clearly indicate their current function Flowcom 2000, was made possible due to up-to- depending on the context. The user is guided date microprocessor technology and know-how, through the menus which allows the meter to be gained over 20 years of experience in this field. The operated and configured even without a manual. main feature of the Flowcom 2000 is its user- This minimizes user errors by offering clear friendly and intuitive operation. For instance, it is instructions. possible to configure the flow processor without

Four binary outputs with built in short circuit protection and over-temperature protection Available for products such as LIN, LOX, LAR, CO2, N2O, LNG, C2H4, C3H8, C4H10 Temperature compensation Intuitive operation Features Ticket printer Dimensions, HxWxD: Power supply: Options Data transfer to remote computer such as a handheld or vehicle board computer Technical Data 200 x 230 x 175 mm 9... 36 VDC Power consumption (w/o options): max. 30 VA Large, back lit graphic LCD (240x64pixels) Operating temperature range: Storage temperatur range: -20... 55 C -30... 65 C Rugged aluminium housing IP65 Serial service interface (RS232) via MIL-connector Software download capability (via RS232) Serial printer port (RS232) Wide power supply range from 9 VDC up to 36 VDC Approvals CE-labeled and designed according to OIML recommendations Type approvals available for Germany, Poland and Austria. Contact our Customer Service Department for type approvals in other countries. Approvals for Denmark and Swizerland in preparation.

urrently there are more than 2000 C Flowcom systems in use world wide. They have been proven to be very reliable and can be economically upgraded as needed. The illustration shows the Example of installed Flow Metering System for Propane/Butane with differential pressure transmitter, temperature probe (PT100), gas bubble sensor and metering section. The ticket printer prints 42 characters per line on paper formats varying from 80x80 mm up to 182x257 mm. The TM-295 produces duplicates along with the original and its graphics capability is unmatched in this class. The printer can work with various fonts in 3 sizes.

Gasbubble sensor The Flowcom 2000 metering system comes with a gas bubble sensor which replaces the traditionally used large and heavy phase separator and thus simplifies the pipework substantially. This sensor is used to determine the percentage amount of gas bubbles in the liquid in order to terminate the delivery if a certain threshold is exceeded which normally occurs when the vehicle tank runs out of liquid. Metering Section The metering section is the nucleus of the system. It operates on the basis of effective pressure measurement. The quantity of media flowing is calculated from the pressure drop across an orifice restrictor in the line. The metering section features no moving parts, and thus is totally maintenance-free. Temperature Sensor The used temperature sensor, type PT100, is a resistance platinum sensor which operates on the basis of the 4-conductor principle. DP-Transmitter In order to measure the differential pressure the reliable ROSEMOUNT 1151, is installed to the metering section. The transmitter provides a 4... 20 ma output signal, from which the electronic processor calculates the flow rate.

The FLOWCOM S8, approved in numerous countries around the world, is installed on more than one thousand road tankers. It features temperature compensation and optional vapor return compensation for applications with dual hose delivery of carbon dioxide and nitrous oxide. It comes with eight binary inputs and outputs which allow the flow processor to control valves and pump. The FLOWCOM LC aims at applications where system cost is a critical factor. It is the most basic member of the Flowcom product line and works without temperature compensation. Thus, it is ideal for metering of products which have a fairly constant temperature such as cryogenic liquids stored in low pressure tanks. The Flowcom LC is intended to be used in applications where specific approvals are not required. An optional ticket printer can be connected. The FILLCOM 250 system was especially designed for stationary applications like loading stations for road- and railroad tanker vehicles. The LC-Display allows for easy operation because menus and messages can be displayed in different languages. Its expandable input and output ports make it an ideal choice for many applications.