Meter FMOGe. Translation of the original. operating manual. Operating manual

Similar documents
Operating Instructions Differential Pressure Transducer PS27

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

Operating instructions. Standstill monitor A / / 2011

Badger Meter Europa GmbH. INSTRUCTION MANUAL Deluxe LCD display for the MN series. September Version MN-Deluxe LCD display-09/01-e

Multi Battery Charger MBC-08. Manual

ACCESS TO THE FUNCTIONS

Instruction Manual FB-606 FB-606 TF. Infrared Manual Remote Control. LJU Automatisierungstechnik GmbH

Operating instructions. Speed monitor D / / 2014

Installation instructions Inclination sensor EC2019 EC / / 2013

Start Stop Relay ehb5040x

Energy Logger. User's Guide. Model EM Washington Street Melrose, MA Phone Toll Free

Installation manual plugs and connectors with screw connection (16/32 A)

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

Operating manual. Diagnostic adapter VAS Operating manual Diagnostic adapter VAS Client documentation Revision: 00 Version: 05/2018

ENVIRONMENTAL PROTECTION

IPCB42501 / IPCB42551

M-610 USER MANUAL PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES

Operating Manual -ENGLISH- Page 1 KWG-ISO

NXT4 Three phase meter for commercial, industrial and advanced residential applications

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Sliding shutter control Aluminium shutters

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Manual Simatek Control Unit GFC 32

Dialock DT Lite. Operating instructions...2. Operating instructions

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

BIC 1B0-ITA50-Q40KFU-SM4A4A BIC 1B0-IT005-Q40KFU-SM4A4A BIC 2B0-ITA50-Q40KFU-SM4A5A. User s Guide

Operating Instructions VEGAMET 381

SURGE PROTECTION USER MANUAL. Surge Protection Device PORTABLE POWER DISTRIBUTION SURGE PROTECTION DEVICE (SPD) B

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

Manual Control Unit GFC 32

Assembly and Operating Instructions Door Control

Display Panel BAT 100 LSN. en Operation Guide

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06

Expansion module EM-BAC-MOD-01. Installation manual

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...

Operating Instruction for Rotating Vane Flow Meter. Model: DRG-...

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

Intrinsically safe batch controller Batching Master 110i

Foot switch. Installation, operation and maintenance manual

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

English. Operating manual. Limit switch GS125. Keep for future reference. Ventures / brands of GHM

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Version-E Manual PR1a. Photocell. Manual. Page 1

Hardware Manual RM Display 1001

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Operating manual Solareg II BASIC DC

Englisch. Operating Manual. Operating Software GHMware Retain for further references. Unternehmen / Marken der GHM

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

B63/ NS MS. EtherNet/IP LINK

Operating Instructions for Rotating Vane Flow Meter. Model: DRH-...

BNI IOL K023 BNI IOL K023. User s Guide

INSTALLATION INSTRUCTIONS 07/2018

CMC III Universal Sensor

Operating Instruction for Turbine-wheel Flow Meter. Model: DRS

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.

AS-i Safety Relay Output Module with Diagnostic Slave

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

High Pressure E/P Regulator. ITVH Series

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2.

Operating Instructions SECUTEST SI /12.10

Assembly and Operating Instructions. M2 module for BDC-i440 control units

Operating Instructions

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

Operating Instructions

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Draft sensor KMB series 30

Operating manual Solareg II BASIC

BNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

Hardware Manual RM Display 2401

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

BNI USB A501. User s Guide

BNI IOL K023 BNI IOL K023. User s Guide

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

C9900-P223 and C9900-P224

SonoMeter 30 Ultrasonic energy meter for heating and cooling applications

Druck DPI 620 advanced modular calibrator

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

Manual. Polaron SMPS Watt power supply for chargers. No. S2024. Copyright Graupner/SJ GmbH

Operating manual. GTL - Configuration tool. Please keep the manual for future use.

XTM1250SA DIN rail three phase four wire LCD display energy meter

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

Manual Control Unit GFC 16

BNI IOL Z012 BNI IOL-302-S01-Z012 BNI IOL Z042

OPERATING INSTRUCTIONS

Transcription:

Operating manual Meter FMOGe Item-No.: 027175201, 027175301, 027175401, 027175501, 027175601, 027175701, 027175801, 027175901 Translation of the original operating manual

Important! Copyright The operating manual is always to be read before commissioning the equipment. No warranty claim will be granted for faults and damage to the equipment arising from insufficient knowledge of the operating manual. HORN GmbH & Co. KG. All rights reserved. Text, graphics and layout copyright protected. Reproduction and copying, including in part, only permitted with written permission. Technical changes reserved. Service Hotline +49 1805 900 301 Reparatur Service +49 1805 900 302 (0,14 /Min: on the German landline network, Mobile telephone max. 0,42 /Min.) service@tecalemit.de Document-No.: 44 1493 103-E Program version: ab V 1.25 As of: 18.10.2012 2 44 1493 103-E Zähler FMOGe

Table of contents 1. Safety instructions...... 4 2. Technical description...... 6 2.1 Description... 6 2.2 Product versions... 6 2.3 Technical data... 7 2.4 Elements of the FMOG... 7 2.4.1 Display... 7 2.4.2 Keyboard... 7 2.4.3 Battery... 7 2.4.4 Measured value recording... 7 2.4.5 Double pulse exit (optional)... 8 3. Operating manual...... 8 3.1 Delivery state... 8 3.2 Basic state, volume measuring... 8 3.3 Reset key... 8 3.4 Totalizer key Total... 8 3.5 Display of the calibration factor keys Total + Reset... 9 4. Error Control......... 9 4.1 Flashing volume display in basic state... 9 4.2 Battery symbol display in the basic state... 9 4.3 Display of five lines -----... 9 5. Programming the meter...... 9 5.1 General... 9 5.2 Switching to the programming mode... 10 5.3 Adjusting the measurement unit and rotational direction... 10 5.4 Setting the calibrating factor... 10 5.5 Resetting all settings (first initialization)... 11 5.6 Ending the programming mode... 11 6. Disposal......... 11 6.1 Return of batteries... 11 7. Declaration of conformity...... 12 8. Notice......... 13 44 1493 103-E Zähler FMOGe 3

1. Safety instructions This device has been constructed per the current state of technology and in accordance with the recognized technical safety regulations. Regardless, risks to the user or third parties and/or damages to the device or other material assets could result from its use. The instructions in this operation manual, especially the safety instructions and the sections marked with warning signs, must thus be complied with. Warning signs and symbols The following symbols are used for especially important information in the operation manual. Special information regarding the efficient use of the device. Special information and/or dos and don'ts for damage prevention. Information and/or dos and don ts for personal accident prevention or comprehensive material damages. Appropriate use This device may only be used when functioning free of technical problems and must used according to its designated use, with full knowledge of the safety and hazard risks and in consideration of the instruction manual! Malfunctions which could affect safety must be remedied immediately. The device and its components are to be used exclusively with the fluids listed and the use designated. Any other use or use extending beyond is deemed as undesignated. The manufacture is not liable for damages thus resulting; the operator shall bear the risk alone. Organisational measures The operation manual must always be kept accessible at the place of use! Every person who is involved with the assembly, commissioning, maintenance and operation of the device must have read and understood the complete operation manual. The type label on the device and the warning signs on the device must be heeded and kept in a fully legible condition. Qualified personnel The personnel for the operation, maintenance and assembly must have the corresponding qualifications for this work. The operator must precisely regulate the spheres of responsibility, authority and monitoring of the personnel. If the personnel do not possess the necessary knowledge, they must be trained and instructed. In addition, the operator must ensure that the contents of the operation manual have been fully understood by the personnel. Water protection The device is designed to handle substances hazardous to water. The valid regulations for the place of use (e.g. water resources act, ordinance for systems with substances hazardous to water) are to be complied with. 4 44 1493 103-E Zähler FMOGe

Compressed air Only persons with special knowledge and experience with pneumatic systems may carry out work on pneumatic parts and equipment. Prior to any inspection, maintenance or repair work, ensure that the equipment is not under pressure. All lines, hoses and screw joints should regularly be checked for leaks and external damage. Any damage must be rectified immediately. Hydraulics Only personnel with special knowledge and experience with hydraulics may work on the hydraulic parts and equipment. All wires, hoses and screws must be checked regularly for leaks and externally detectable damages and these must be remedied immediately. Squirting oil can cause injuries and fires. Note the safety guidelines valid for the product when dealing with oils, greases and other chemical substances! Maintenance and repairs In accordance with the legal regulations, only companies specialized can be hired for work with systems for substances hazardous to water. Do not make any modification, additions or conversions to the system which could affect its safety with the approval of the manufacturer. Replacement parts must correspond to the technical requirements of the manufacturer. This is always ensured when original parts are used. Electrical energy Work on the electrical equipment may only be conducted by a trained electrical technician or by trained personnel under the supervision of an electrical technician as per the electrical engineering regulations. Machines and system components which are to undergo inspection, maintenance and repair work must be rendered currentless. First check that these components are voltage-free, then ground and short circuit them, as well as insulate neighboring voltage-carrying components. 44 1493 103-E Zähler FMOGe 5

2. Technical description 2.1 Description The FMOGe is a flow meter for flowing liquids based on the measuring principle of an oval wheel meter. It can be used as a fixed meter or as a manual flow meter. The pulse generator allows it to be used in a fluid management system. The FMOGe must not be operated with combustible and explosive liquids from hazard classes AI, AII and B. Liquids of hazard class A III must not be used, if they are heated above their flash point. The operation of the remote oil equipment in explosive areas is not permitted. This would constitute a risk of explosion! The FMOGe oval wheel meter consists of a measuring chamber with an oval pair of wheels and a cover containing the evaluation electronics as well as display and keyboard. The oval wheels are each equipped with a magnet pair which in the case of volume flow transfers the meter pulses to staggered reed switches on the evaluation electronics. 2.2 Product versions Item no. Model 027175401 Meter inlet, bottom 027175501 Meter inlet; top 027175601 Meter inlet, left 027175701 Meter inlet, right 027175201 Meter with pulse output, inlet, bottom 027175301 Meter with pulse output, inlet, top 027175801 Meter with pulse output, inlet, left 027175901 Meter with pulse output, inlet, right 6 44 1493 103-E Zähler FMOGe

2.3 Technical data Housing Viscosity range Smallest volumetric flow Q min Largest volumetric flow Q max Max. operating pressure P max Threaded connection aluminium 20 2000 mpa s 1 l /min (HDZ 0,5 l /min) 10 l / min 10 bar G ½ internal Measuring accuracy +/- 0,5% Dimensions Weight Permitted operating temperature Permissible storage temperature Protection class IP 65 Battery 2.4 Elements of the FMOG 2.4.1 Display 90x90*x60 (wxhxd) * flow direction approx. 0,5 kg -10 C to +50 C -20 C to +70 C Lithium battery LC display with five digit amount display, 16 mm high characters as well as display of the measuring unit Litre (optional US-Gal, UK-Gal) and display at low battery capacity. The smallest numeral step of the measured value is 0,01 litres, the smallest numeral step of the non-resettable totalizer is 1 litre. 2.4.2 Keyboard Foil keyboard with two keys: Total and Reset. 2.4.3 Battery Lithium battery (type CR ½ AA, 3,6V, 1200 mah) with a minimum service life of approx. 10 years given a flow amount of 1.000.000 litres during this time. The battery can be exchanged when casing is opened. Totals and calibration values are saved during the exchange. As the calibration marks have to be damaged when changing the battery, the battery is to be changed as a precautionary measure when calibration is performed. 2.4.4 Measured value recording Recording of the double pulse signal of the sensing chamber. Error redundant saving and selection of measuring unit and calibration factor. 44 1493 103-E Zähler FMOGe 7

2.4.5 Double pulse exit (optional) In the option double pulse exit, the counter is equipped with a dual-channel double pulse exit with 2 x 100 pulses / measuring unit. The pulses are phase-deferred by 90 ± 60. The counter can be operated with an external voltage source of 5 VDC 24 VDC. Data of the pulse exits: open collector, UCEmax =30V, Icmax =50 ma Pin assignment: Connection V dc (5 VDC 24 VDC) Pulse exit A Pulse exit B Gnd (Mass) Colour Yellow Green White Brown 3. Operating manual 3.1 Delivery state At delivery, the counter is set at works to the measuring unit litre and the calibration factor 1.000. The calibration factor of pre-inspected counters have already been justified at works, otherwise this can also be done subsequently. The counter is ready to measure dispensations without any further interventions. 3.2 Basic state, volume measuring In the basic state the LC display shows the measured volume since the last reset. The display shows two pre-decimal and three decimal places, the smallest digit step is 0,005 litres. In the lower line, the measuring unit litre (optional US-Gal, UK-Gal) is displayed. During the measurement, the keys are locked. A flashing display indicates that more than two incorrect pulses (phase errors) have occurred since the last reset. The keys are blocked when metering takes place. 3.3 Reset key After pressing the key Reset the programme state is displayed as long as the key remains pressed. After releasing the key, all segments are tested successively, and the resetting of the volume counter is executed. Should pulse signals incur at the same time (volume flow), the display test is interrupted and the counter changes back to the basic state. 3.4 Totalizer key Total After pressing the key Total, the totalizer state is displayed as long as the key remains pressed. The display is in rounded litres. Should pulse signals incur at the same time (volume flow), the display of the totalizer is interrupted, and the counter changes back to the basic state. 8 44 1493 103-E Zähler FMOGe

3.5 Display of the calibration factor keys Total + Reset When the Reset key is pressed in addition to the pressed Total key (totaliser status display), the set calibrating factor is displayed for as long as the two keys are pressed. The calibrating factor can be between 0.950 and 1.500. In addition, the rotational direction is displayed by the letters l (left) or r (right) in the foremost display segment Should pulse signals proceed (volumetric flow) during the display, then the calibrating factor display is interrupted and changed to the basic state. 4. Error Control 4.1 Flashing volume display in basic state A flashing volume display indicates that more than two incorrect pulses (phase errors) have occurred since the last reset. The incorrect pulses and the flashing can be reset by pressing the Reset button. If this fault occurs repeatedly it may be assumed that there is either air in the hydraulic system or that pressure surges and hence back pulses are briefly occurring. These can be suppressed by the use of a suitable back flow preventer. 4.2 Battery symbol display in the basic state The built-in 3.6 V lithium battery, type CR ½ AA, is designed for a minimum operating life of approx. 10 years given a 1,000,000 litre flow rate during this period. The appearance of the battery symbol in the basic state indicates that the battery capacity is exhausted and that the battery must be replaced within the next 6 months. The times may be reduced given extreme operating conditions such as a high flow rate or very low temperatures! The battery can be replaced without tools once the housing is opened. Cumulative and calibration values are not affected by replacement. In the event of the W & M seal being damaged, the responsible body (weights and measures office) must be informed and the meter must be re-calibrated if necessary. 4.3 Display of five lines ----- Should the counter stop functioning and the display only show five horizontal lines, then an error has occurred in the evaluation electronic, and the counter has to be exchanged. 5. Programming the meter 5.1 General The measuring unit (litre, US-Gal, UK-Gal) and the calibration factor (0.950 1.050) can be set and saved. 44 1493 103-E Zähler FMOGe 9

5.2 Switching to the programming mode In order to access programming mode, the cover with the evaluation electronics is to be disconnected from the measuring chamber; the evaluation electronics is to remain installed in the cover. For this, the W & M seal on calibrated meters must be removed. Then the pushbutton on the back of the evaluation electronics must be pressed once. Then all segments rapidly flash (approx. 3 Hz) on the LC display. 5.3 Adjusting the measurement unit and rotational direction The set rotational direction and the measurement unit appear on the display when the Reset button is pressed. Renewed pressing of the Reset button results in the rotational direction switching between l for left and r for right and the measurement unit switching between Litre, US-Gal and UK-Gal. The set rotational direction and measurement unit are taken over by pressing the Total button. Notice: Any change to the measurement unit causes the volume indicator and totaliser to be reset. Pressing the programming button without previously pressing the Total button terminates programming mode without adopting the displayed rotational direction and measurement unit. 5.4 Setting the calibrating factor After pressing the Total key, the calibrating factor set appears in the display. After repeatedly pressing the Total button the calibration factor is cumulatively counted in steps of 0.001, in order to jump back to the smallest possible value 0.950 after the highest possible value of 1.050 etc. Press the Reset key and the set calibrating factor is taken on. Pressing the programming button without previously pressing the Reset button terminates programming mode without adopting the displayed calibration factor. Before a new calibrating factor can be established, a delivery must be made into a satisfactorily accurate vessel or undertaken by means of a reference meter. The new calibrating factor is calculated as follows: Volume Factor new = Factor old Volume dispensed displayed Example: A 2 litre calibration cylinder is filled; the meter only indicates 1.985 litres. The existing calibrating factor is 1.004. The new calibrating factor is calculated to: 2,000 1,004 = 1,012 (rounded) 1,985 10 44 1493 103-E Zähler FMOGe

5.5 Resetting all settings (first initialization) If the Reset button is also pressed while the Total button is pressed (setting of calibrating factor), all values of the meter are deleted and a first time initialization is carried out. Following values are initialized: Measuring unit: Litres Calibration factor: 1.000 Dispensing amount: Totalizer: 5.6 Ending the programming mode 0, 00 litres 0 litres To end the programming mode, press the mode key once again after setting the calibration factor. The counter switches back into the basic state. If no key has been pressed for longer than five minutes while in programming mode, then the counter will switch back to the basic state automatically. 6. Disposal The device is to be emptied completely and the liquids properly disposed of in case it is taken out of service. The equipment is to be disposed of properly when taken permanently out of service: - Return old metal for recycling. - Return plastic parts for recycling. - Return electronic waste for recycling. The water legal regulations are to be followed. 6.1 Return of batteries Batteries must not be disposed of with the domestic waste. Batteries can be returned free of charge via a suitable collecting point or to the dispatch stores. Consumers are legally obliged to return used batteries. Batteries that contain harmful substances are marked with a crossed out dustbin (see above) and the chemical symbol (Cd, Hg or Pb) of the heavy metal that is decisive for the classification as containing harmful substances: 1. Cd stands for cadmium 2. Pb stands for lead 3. Hg stands for mercury 44 1493 103-E Zähler FMOGe 11

7. Declaration of conformity 12 44 1493 103-E Zähler FMOGe

8. Notice 44 1493 103-E Zähler FMOGe 13

14 44 1493 103-E Zähler FMOGe

44 1493 103-E Zähler FMOGe 15

HORN GmbH & Co. KG Munketoft 42 24937 Flensburg Germany T +49 461-8696-0 F +49 461-8696-66 www.tecalemit.de info@tecalemit.de 16 44 1493 103-E Zähler FMOGe