Torque Thrust Transducers Model Issue 1. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION PORTFOLIO VALUE TO CUSTOMERS

Similar documents
Model SC500. Programmable Single-Channel Transducer Indicator/Conditioner DESCRIPTION FEATURES

MICRO SWITCH Snap-in Panel Mount Basic Switches. DM DP Series. Datasheet

Rotary Switches. Datasheet

Push-Pull and E-Stop Switches. Datasheet

SS400 Series. Please refer to SS400 Series Order Guide on page 7 for details.

MICRO SWITCH Military-Grade Toggle Switches TL Series Issue 4. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO

SMART Position Sensor, 100 and 180 Arc Configurations

MICRO SWITCH Military-Grade Toggle Switches. TL Series. Datasheet

MICRO SWITCH Miniature Sealed Basic Switches. SE and XE Series. Datasheet

Quick Start Guide for the Limitless WLS Series Single Switch Adapter

MICRO SWITCH Sealed Subminiature Basic Switches. ZW Series. Datasheet

MICRO SWITCH Commercial-Grade Toggle Switches. NT Series. Datasheet

With this sensor, Honeywell has utilized MR technology through the ASIC at a level never before accomplished.

MICRO SWITCH Standard Basic Switches V15 Series Issue 9. Datasheet

Installation Instructions for the ISSUE 3 RDS-DIN1 Series Single Channel Interface Module PK 80103

Technical Note Entering and Using Command Mode on the Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH- 6130/6131 Series

MICRO SWITCH Miniature Precision Limit Switches 914CE Series Issue 7. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION

MICRO SWITCH Premium Subminiature Basic Switches. SM Series. Datasheet

MICRO SWITCH Premium Subminiature Basic Switches. SX Series. Datasheet

MICRO SWITCH General Purpose Limit Switches. SZL-WL Series. Datasheet

With this sensor, Honeywell has utilized MR technology through the ASIC at a level never before accomplished.

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

MICRO SWITCH Compact Precision Limit Switches. 14CE Series. Datasheet

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

HC900 Remote Termination Panel (RTP) For Relay Outputs

MICRO SWITCH Miniature Precision Limit Switches 914CE Series Issue 8. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION

3M Serial Advanced Technology Attachment (SATA) Connector Signal Plug, Boardmount, Surface Mount Right Angle and PTH Vertical

TM0-1 AMPLIFIER / CONDITIONER MODULE OPERATORS MANUAL. Transducer Techniques R

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Sensing method Appearance Connection method Sensing distance Model. Pre-wired (2 m) Power supply Application Appearance Function Model

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

LCI User Manual mantracourt.com

Power supply voltage Output configuration Output phases Resolution (pulses/rotation) Model. 100, 200, 360 E6A2-CWZ5C (resolution) 0.

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units.

S82S (3/7.5-W Models)

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

SP6R Level Controller Operation Manual

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction.

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

LCI Load Cell Junction Box with Fault Monitor

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Number of input channels

3M Pak 100 Wiremount Plug Series

IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL MONITORED DEVICE

Description, continued

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4. 40 XW2B-40G5 Flat Cable Connectors

D5B. Detects Objects in Multiple Directions with High Sensitivity, Ideal for Robotics. Mechanical Touch Switch. Model Number Structure

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

Product Description. S&C IntelliNode Interface Module. Table of Contents. Instruction Sheet

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

CMOS Laser Sensor with Built-in Amplifier ZX0

User Instructions for the

Long Sensing-distance Capacitive Separate Amplifier Proximity Sensor E2J-W10MA 1M E2J-W20MA 1M. E2J-JC4A Amplifier Unit

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

CSM_PYF S/P2RF- -S_DS_E_2_5

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

Solid State Relays with Failure Detection Function

SVP110 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

Aluminum-detecting Proximity Sensor (Separate Amplifier Type)

Corona 70,000 Ft. Permeability Risetime Degradation (Mated Pair) 2.0 max MH z

Features various encoder interfaces and controls multiple analog servo drives at high speeds

P027 Series Pressure Transducer Installation & Operation Manual

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

DFI 9000 PORTABLE DIGITAL INDICATOR USER S GUIDE

3M Ribbon Cable Socket and Header, Series 451 & " x.050" (1.27 mm x 1.27 mm)

Connecting Sockets, Mounting Brackets, DIN Rails

Low Pressure Digital & Analog Sensor

iconverter 2-Module Power Chassis

X-12s Users Manual. X-12s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc.

OPERATING INSTRUCTIONS

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

SVP48 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

Communication Unit Dedicated for RFID V680 Allowing Direct Connection to OMRON PLC CJ/ CS/NJ-series

3M 4-Wall, Tripolarized Header.050".100" Latch/Ejector, PTH & SMT Straight, PTH Right Angle 810 Series

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

SafePace 600 Variable Messaging Sign

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

Model A7BS

Series 8000 RF Signal Switch Solution

Series 8000 RF Signal Switch Solution

SPECIFICATION SHEET Electronic Force Proving Instrument (For verification of uni-axial testing machine) MODEL : FS-117F

NPN output. 200 mm. Type Cable length Model Remarks

Industrial Wet/Wet Differential Pressure Transducer

6A27 6A40 6A68 6A154 6A175

3M I/O Connector Mounting Options and Hardware

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

Tempco Instruction Manual

THERM-O-FLOW EC-20/40 Timer

SX100A. Features. Typical Applications. Description

onlinecomponents.com

PSD Strain Gauge or Load Cell Hand Held Display TEDS enabled

Automated Tuner System Power Distribution Hub

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4 40 XW2B-40G5 *1 50 XW2B-50G5 60 XW2B-60G5 40 XW2B-40G5-T

PRODUCT CONTENTS... 3 II. REQUIRED MATERIALS... 3 III. OVERVIEW... 3 IV. BENCH LAYOUT...

DF-G2 High Speed Expert Dual Display Small Object Counter

P7TF-IS16/OS16/OS08. I/O classification I/O points Internal I/O common Rated voltage Model 12 VDC P7TF-IS16 DC12 24 VDC P7TF-IS16 DC24 For inputs

SX01DN. Features. Typical Applications. Description

Transcription:

Torque Thrust Transducers Model 6459 FEATURES 500 lb-in torque, 500 lb thrust 1000 lb-in torque, 1000 lb thrust 2000 lb-in torque, 2000 lb thrust 0.15 % non-linearity and hysteresis Minimized crosstalk Extraneous load resistance Single piece construction Fatigue rated 008906 Issue 1 Datasheet 6459 - Low capacity DESCRIPTION Model 6459 torque thrust transducers are used in applications where the need to sense both torque and thrust parameters simultaneously. Nickel-plated, alloy steel, one-piece construction. Designed specifically to provide the strength and rigidity required to withstand extraneous loads and bending moments. Unique construction provides both maximum structure life and minimum thrust/torque crosstalk. VALUE TO CUSTOMERS Capable of sensing both torque and thrust parameters simultaneously Independent torque and thrust connectors with output values POTENTIAL APPLICATIONS Industrial Material test machines Durability testing Structural/integrity testing Fatigue/endurance testing Metrology lab R&D center PORTFOLIO The Model 6459 is part of a family of torque thrust transducers that includes Models 6467-6470. DIFFERENTIATION Unique design offers enhanced accuracy performance with minimal crosstalk error, along with ability to handle extraneous loading conditions under high-cycle fatigue test situations Sensing and Productivity Solutions

Output Output SETUP Model 6469 Torque Thrust Transducer Table 1. Performance Specifications Torque-thrust range Non-linearity Hysteresis Repeatability Output @ rated capacity 500 lb-in torque, 500 lb thrust 1000 lb-in torque, 1000 lb thrust 2000 lb-in torque, 2000 lb thrust ±0.1 % of rated output ±1.5 mv/v (nominal) (Both components) Figure 1. Typical System Diagram DIN-Rail Mount Table 2. Environmental Specifications Temperature, operating Temperature, compensated Temperature effect, zero Temperature effect, output Table 3. Electrical Specifications Excitation (maximum) Insulation resistance Bridge resistance Zero balance Static overload capacity -54 C to 93 C [-65 F to 200 F] 21 C to 77 C [70 F to 170 F] ±0.002 % of rated output/ F ±0.002 % of reading/ F 20 Vdc or Vac RMS > 5000 mohm @ 50 Vdc 700 ohm (nominal) ±1 % of rated output 150 % of rated capacity DIN-Rail Mount For long cable runs or electrically noisy environments, an amplified sensor or locally mounted amplifier is often preferred. NOTE: There are two connectors on the transducer. They both need a cable and an amp. MODEL 6459 Customer Supplied Chart recorder Alarm panel Data acquisition Computer PLC Display Units SC2000 SC3004 SC2001 2003.1 lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE UP DOWN ENTER EXIT Mating Connectors and Cables 064-LW13621 Mating connector 7200-76-XX* Mating connector and six-conductor cable (unamplified unit with sense leads, but not shunt cal) 7200-75-XX** Mating connector and four-conductor cable (unamplified unit without sense leads, but not shunt cal) 7200-111-XX* Mating connector and six-conductor cable 7200-110-XX** Mating connector and four-conductor cable * XX represents length in feet, 100 ft maximum ** XX represents length in feet, 20 ft maximum 2 sensing.honeywell.com

Model 6459 Torque Thrust Transducer Figure 2. Mounting Dimensions For reference only, mm[in] 4X 3/8-24 stud on a Ø 69,85 [Ø 2.75] BC Thrust Ø 38,13 [Ø 1.501] 6,35 [0.25] Torque Ø 101,6 [Ø 4.00] Ø 88,9 [Ø 3.50] 25,4 [1.00] 2 X MS-3102A-14S-5P 19,05 [0.75] 95,25 [3.75] 4,83 [0.19] Ø 107,87 [Ø 4.247] Ø 152,4 [Ø 6.00] 16X Ø 7,11 [Ø 0.28] thru on a Ø 127 [Ø 5.00] BC Sensing and Productivity Solutions 3

Torque Thrust Transducers Model 6467 008907 Issue 1 Datasheet FEATURES 2500 in-lb, 2500 lb 2500 in-lb, 5000 lb 5000 in-lb, 10,000 lb 0.15 % non-linearity and hysteresis Minimized crosstalk Extraneous load resistance Single piece construction Fatigue rated DESCRIPTION Model 6467 torque thrust transducers are used in applications where the need to sense both torque and thrust parameters simultaneously. Nickel-plated, alloy steel, one-piece construction. Designed specifically to provide the strength and rigidity required to withstand extraneous loads and bending moments. Unique construction provides both maximum structure life and minimum thrust/torque crosstalk. VALUE TO CUSTOMERS Capable of sensing both torque and thrust parameters simultaneously Independent torque and thrust connectors with output values POTENTIAL APPLICATIONS Industrial Material test machines Durability testing Structural/integrity testing Fatigue/endurance testing Metrology lab R&D center PORTFOLIO The Model 6467 is part of a family of torque thrust transducers that includes Models 6459 and 6467-6470. DIFFERENTIATION Unique design offers enhanced accuracy performance with minimal crosstalk error, along with ability to handle extraneous loading conditions under high-cycle fatigue test situations Sensing and Productivity Solutions

Output Output SETUP Model 6467 Torque Thrust Transducer Table 1. Performance Specifications Torque-thrust range Non-linearity Hysteresis Repeatability Output @ rated capacity 2500 in-lb, 2500 lb 2500 in-lb, 5000 lb 5000 in-lb, 10,000 lb ±0.1 % of rated output ±1.5 mv/v (nominal) (Both components) Figure 1. Typical System Diagram DIN-Rail Mount Table 2. Environmental Specifications Temperature, operating Temperature, compensated Temperature effect, zero Temperature effect, output -54 C to 93 C [-65 F to 200 F] 21 C to 77 C [70 F to 170 F] ±0.002 % of rated output/ F ±0.002 % of reading/ F DIN-Rail Mount Customer Supplied Chart recorder Alarm panel Data acquisition Computer PLC Table 3. Electrical Specifications Excitation (maximum) 20 Vdc or Vac RMS Insulation resistance > 5000 mohm @ 50 Vdc Bridge resistance 700 ohm (nominal) Zero balance ±1 % of rated output Static overload capacity 150 % of rated capacity For long cable runs or electrically noisy environments, an amplified sensor or locally mounted amplifier is often preferred. NOTE: There are two connectors on the transducer. They both need a cable and an amp. MODEL 6467 Display Units SC2000 SC3004 SC2001 2003.1 lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE UP DOWN ENTER EXIT Mating Connectors and Cables 064-LW13621 Mating connector 7200-76-XX* Mating connector and six-conductor cable (unamplified unit with sense leads, but not shunt cal) 7200-75-XX** Mating connector and four-conductor cable (unamplified unit without sense leads, but not shunt cal) 7200-111-XX* Mating connector and six-conductor cable 7200-110-XX** Mating connector and four-conductor cable * XX represents length in feet, 100 ft maximum ** XX represents length in feet, 20 ft maximum 2 sensing.honeywell.com

Model 6467 Torque Thrust Transducer Figure 2. Mounting Dimensions For reference only, mm[in] Thrust Ø 63,53 [2.501] 6,35 [0.25] 4 x 1/2-13 UNC 19,05 [0.75] on a 101,6 [Ø 4.00] BC Torque Ø 145,8 [Ø 5.74] 2 X MS-3102A-14S-5P 44,45 [1.75] 133,35 [5.25] Ø 187,45 [Ø 7.38] Ø 133,27 [Ø 5.247] 2,29 [0.09] 16 X Ø 10,72 [Ø 0.422] thru on a Ø 165,1 [Ø 6.500] BC Sensing and Productivity Solutions 3

Torque Thrust Transducers Model 6468 008904 Issue 1 Datasheet FEATURES 10,000 lb-in, 20,000 lb 25,000 lb-in, 50,000 lb 25,000 lb-in, 75,000 lb 0.15 % non-linearity and hysteresis Minimized crosstalk Extraneous load resistance Single piece construction Fatigue rated DESCRIPTION Model 6468 torque thrust transducers are used in applications where the need to sense both torque and thrust parameters simultaneously. Nickel-plated, alloy steel, one-piece construction. Designed specifically to provide the strength and rigidity required to withstand extraneous loads and bending moments. Unique construction provides both maximum structure life and minimum thrust/torque crosstalk. VALUE TO CUSTOMERS Capable of sensing both torque and thrust parameters simultaneously Independent torque and thrust connectors with output values POTENTIAL APPLICATIONS Industrial Material test machines Durability testing Structural/integrity testing Fatigue/endurance testing Metrology lab R&D center PORTFOLIO The Model 6468 is part of a family of torque thrust transducers that includes Models 6459 and 6467-6470. DIFFERENTIATION Unique design offers enhanced accuracy performance with minimal crosstalk error, along with ability to handle extraneous loading conditions under high-cycle fatigue test situations Sensing and Productivity Solutions

Output Output SETUP Model 6468 Torque Thrust Transducer Table 1. Performance Specifications Torque-thrust range Non-linearity Hysteresis Repeatability Output @ rated capacity 10,000 lb-in, 20,000 lb 25,000 lb-in, 50,000 lb 25,000 lb-in, 75,000 lb ±0.1 % of rated output ±1.5 mv/v (nominal) (Both components) Figure 1. Typical System Diagram DIN-Rail Mount Table 2. Environmental Specifications Temperature, operating Temperature, compensated Temperature effect, zero Temperature effect, output -54 C to 93 C [-65 F to 200 F] 21 C to 77 C [70 F to 170 F] ±0.002 % of rated output/ F ±0.002 % of reading/ F DIN-Rail Mount Customer Supplied Chart recorder Alarm panel Data acquisition Computer PLC Table 3. Electrical Specifications Excitation (maximum) 20 Vdc or Vac RMS Insulation resistance > 5000 mohm @ 50 Vdc Bridge resistance 700 ohm (nominal) Zero balance ±1 % of rated output Static overload capacity 150 % of rated capacity For long cable runs or electrically noisy environments, an amplified sensor or locally mounted amplifier is often preferred. NOTE: There are two connectors on the transducer. They both need a cable and an amp. MODEL 6468 Display Units SC2000 SC3004 SC2001 2003.1 lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE UP DOWN ENTER EXIT Mating Connectors and Cables 064-LW13621 Mating connector 7200-76-XX* Mating connector and six-conductor cable (unamplified unit with sense leads, but not shunt cal) 7200-75-XX** Mating connector and four-conductor cable (unamplified unit without sense leads, but not shunt cal) 7200-111-XX* Mating connector and six-conductor cable 7200-110-XX** Mating connector and four-conductor cable * XX represents length in feet, 100 ft maximum ** XX represents length in feet, 20 ft maximum 2 sensing.honeywell.com

Model 6468 Torque Thrust Transducer Figure 2. Mounting Dimensions For reference only, mm[in] Ø 101,67 [4.003] 6,35 [0.25] Thrust 8 x 5/8-11 UNC 28,7 [1.12] on a 165,1 [6.50] BC Torque Ø 203,2 [Ø 8.00] 2 X MS-3102A-14S-5P 215,9 [8.50] Ø 273,05 [Ø 10.75] 57,15 [2.25] Ø 203,12 [Ø 7.997] 4,06 [0.16] 16 X Ø 17,53 [Ø 0.69] thru on a Ø 241,3 [Ø 9.50] BC Sensing and Productivity Solutions 3

Torque Thrust Transducers Model 6469 008905 Issue 1 Datasheet FEATURES 50,000 lb-in, 50,000 lb 50,000 lb-in, 100,000 lb 0.15 % non-linearity and hysteresis Minimized crosstalk Extraneous load resistance Single piece construction Fatigue rated DESCRIPTION Model 6469 torque thrust transducers are used in applications where the need to sense both torque and thrust parameters simultaneously. Nickel-plated, alloy steel, one-piece construction. Designed specifically to provide the strength and rigidity required to withstand extraneous loads and bending moments. Unique construction provides both maximum structure life and minimum thrust/torque crosstalk. VALUE TO CUSTOMERS Capable of sensing both torque and thrust parameters simultaneously Independent torque and thrust connectors with output values POTENTIAL APPLICATIONS Industrial Material test machines Durability testing Structural/integrity testing Fatigue/endurance testing Metrology lab R&D center PORTFOLIO The Model 6469 is part of a family of torque thrust transducers that includes Models 6459 and 6467 to 6470. DIFFERENTIATION Unique design offers enhanced accuracy performance with minimal crosstalk error, along with ability to handle extraneous loading conditions under high-cycle fatigue test situations Sensing and Productivity Solutions

Output Output SETUP Model 6469 Torque Thrust Transducer Table 1. Performance Specifications Torque-thrust range Non-linearity Hysteresis Repeatability Output @ rated capacity 50,000 lb-in, 50,000 lb 50,000 lb-in, 100,000 lb ±0.1 % of rated output ±1.5 mv/v (nominal) (Both components) Figure 1. Typical System Diagram DIN-Rail Mount Table 2. Environmental Specifications Temperature, operating Temperature, compensated Temperature effect, zero Temperature effect, output Table 3. Electrical Specifications Excitation (maximum) Insulation resistance Bridge resistance Zero balance Static overload capacity -54 C to 93 C [-65 F to 200 F] 21 C to 77 C [70 F to 170 F] ±0.002 % of rated output/ F ±0.002 % of reading/ F 20 Vdc or Vac RMS > 5000 mohm @ 50 Vdc 700 ohm (nominal) ±1 % of rated output 150 % of rated capacity DIN-Rail Mount For long cable runs or electrically noisy environments, an amplified sensor or locally mounted amplifier is often preferred. NOTE: There are two connectors on the transducer. They both need a cable and an amp. MODEL 6469 Customer Supplied Chart recorder Alarm panel Data acquisition Computer PLC Display Units SC2000 SC3004 SC2001 2003.1 lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE UP DOWN ENTER EXIT Mating Connectors and Cables 064-LW13621 Mating connector 7200-76-XX* Mating connector and six-conductor cable (unamplified unit with sense leads, but not shunt cal) 7200-75-XX** Mating connector and four-conductor cable (unamplified unit without sense leads, but not shunt cal) 7200-111-XX* Mating connector and six-conductor cable 7200-110-XX** Mating connector and four-conductor cable * XX represents length in feet, 100 ft maximum ** XX represents length in feet, 20 ft maximum 2 sensing.honeywell.com

Model 6469 Torque Thrust Transducer Figure 2. Mounting Dimensions For reference only, mm[in] Thrust Ø 101,67 [4.003] 6,35 [0.25] 8 x 7/8-9 UNC 28,702 [1.13] on a 165,1 [6.50] BC Torque Ø 206,5 [Ø 8.13] 2 X MS-3102A-14S-5P 254 [10.0] Ø 273,05 [Ø 10.75] 76,2 [3.00] Ø 203,12 [Ø 7.997] 7,11 [0.28] 16 X Ø 21,41 [Ø 0.843] thru on a Ø 241,3 [Ø 9.50] BC Sensing and Productivity Solutions 3

Torque Thrust Transducers Model 6470 008908 Issue 1 Datasheet FEATURES 100,000 lb-in 200,000 lb 0.15 % non-linearity and hysteresis Minimized crosstalk Extraneous load resistance Single piece construction Fatigue rated DESCRIPTION Model 6470 torque thrust transducers are used in applications where the need to sense both torque and thrust parameters simultaneously. Nickel-plated, alloy steel, one-piece construction. Designed specifically to provide the strength and rigidity required to withstand extraneous loads and bending moments. Unique construction provides both maximum structure life and minimum thrust/torque crosstalk. POTENTIAL APPLICATIONS Industrial Material test machines Durability testing Structural/integrity testing Fatigue/endurance testing Metrology lab R&D center PORTFOLIO The Model 6470 is part of a family of torque thrust transducers that includes Models 6459 and 6467-6469. VALUE TO CUSTOMERS Capable of sensing both torque and thrust parameters simultaneously Independent torque and thrust connectors with output values DIFFERENTIATION Unique design offers enhanced accuracy performance with minimal crosstalk error, along with ability to handle extraneous loading conditions under high-cycle fatigue test situations Sensing and Productivity Solutions

Output Output SETUP Torque Thrust Transducers 00XXXX-1-EN Table 1. Performance Specifications Torque-thrust range Non-linearity Hysteresis Repeatability Output @ rated capacity 100,000 lb-in 200,000 lb ±0.1 % of rated output ±1.5 mv/v (nominal) (Both components) Figure 1. Typical System Diagram DIN-Rail Mount Table 2. Environmental Specifications Temperature, operating Temperature, compensated Temperature effect, zero Temperature effect, output Table 3. Electrical Specifications Excitation (maximum) Insulation resistance Bridge resistance Zero balance Static overload capacity -54 C to 93 C [-65 F to 200 F] 21 C to 77 C [70 F to 170 F] ±0.002 % of rated output/ F ±0.002 % of reading/ F 20 Vdc or Vac RMS > 5000 mohm @ 50 Vdc 700 ohm (nominal) ±1 % of rated output 150 % of rated capacity NOTE: There are two connectors on the transducer. They both need a cable and an amp. DIN-Rail Mount For long cable runs or electrically noisy environments, an amplified sensor or locally mounted amplifier is often preferred. MODEL 6470 Customer Supplied Chart recorder Alarm panel Data acquisition Computer PLC Display Units SC2000 SC3004 SC2001 2003.1 lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE UP DOWN ENTER EXIT Mating Connectors and Cables 064-LW13621 Mating connector 7200-76-XX* Mating connector and six-conductor cable (unamplified unit with sense leads, but not shunt cal) 7200-75-XX** Mating connector and four-conductor cable (unamplified unit without sense leads, but not shunt cal) 7200-111-XX* Mating connector and six-conductor cable 7200-110-XX** Mating connector and four-conductor cable * XX represents length in feet, 100 ft maximum ** XX represents length in feet, 20 ft maximum 2 sensing.honeywell.com

Model 6470 Figure 2. Mounting Dimensions For reference only, mm[in] Thrust Ø 127,08 [5.003] 6,35 [0.25] 8 x 1-8 UNC 38,1 [1.5] on a Ø 241,3 [Ø 9.50] BC Torque Ø 304,8 [Ø 12.00] 2 X MS-3102A-14S-5P 279,4 [11.00] 95,25 [3.75] Ø 419,1 [Ø 16.50] Ø 317,42 [Ø 12.497] 4,83 [0.19] 16 X Ø 28,7 [Ø 1.13] thru on a Ø 361,95 [Ø 14.25] BC Sensing and Productivity Solutions 3

ADDITIONAL MATERIALS The following associated literature is available on the web site at sensing.honeywell.com: Torque transducer range guide White Paper: New Ways To Torque m WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. m WARNING MISUSE OF DOCUMENTATION The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Find out more serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office. To learn more about s test and measurement products, call +1-614-850-5000, visit http://measurementsensors. honeywell.com, or e-mail inquiries to info.tm@honeywell.com Warranty/Remedy warrants goods of its manufacture as being free of defective materials and faulty workmanship. s standard product warranty applies unless agreed to otherwise by in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to during the period of coverage, will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. Sensing and Productivity Solutions 1985 Douglas Drive North Golden Valley, MN 55422 honeywell.com September 2015 2015 International Inc. All rights reserved.