SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

Similar documents
RS485 MODBUS Module 8AO

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

RS485 MODBUS Module 6RO

RS 485 Mini Modbus 1AO

SDM-8I8O. Expansion Module 8 digital inputs, 8 digital outputs. Manufactured for

RS485 MODBUS Module 16I-M

RS485 MODBUS Module 8I8O

RS485 MODBUS Module 8I8RO

RS485 IO Slim Module MOD-ETH

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

isma-b-fcu FCU Hardware User Manual Global Control 5 Sp. z o.o. Warsaw, Poland

NetBiter I/O Extender User Manual

Real Time Clock with Temperature Sensor and RS485/Modbus Comunications

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.

ASTAT XB/XBm Remote Operator

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

MU110-6U. Analog output module 6 channel. User guide

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

MOD-MUX MODBUS TCP I/O PRODUCTS

VPGate Manual PROFIBUS to serial

SmartMod DC Digital Input Module HE359DIM610 12/24VDC Negative Logic

3 CH Analog Output module / CANopen

Expansion Module HZS 541-1S

SIC184 Manual Stepper motor servo controller

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL

XT-9100 Technical Bulletin

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

PGR-3200 MANUAL INSULATION MONITOR

ProfiPro Distributed PROFIBUS I/O Modules User Manual

Message Runner KP3H. Text Display. Small messages on your machine. Compact DIN 36 x 72 profile. Green and orange character display.

SC2004MBS 20x4 Characters MODBUS RTU Slave LCD

EE870 Modular CO 2 Transmitter

KTA-250 Anemometer Alarm Card

Submittal Data Sheet WAGO Node for itm

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

Process displays For current and voltage

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

SSI-1016H Specifications and Operation Manual

MODEL: R2K-1 SEN TRONIC AG. R2K Series

MODBUS RTU MODULE INSTRUCTIONS. for use with WSIQ2/WSE

Copyright: December 2017 Nidec Issue: E

DL-10. User Manual. RS-485 Remote Temperature and Humidity. English Ver. 1.0, Jul. 2017

Carbon Monoxide Sensor - ModBus

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Serial Data DIN Fiber Link System

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

Serial Communication Converters & Adapters Instruction Manual

Warranty. Warning. Copyright. Contact Us

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

DI-917MB/DI-918MB. Heavy-duty 1A solid-state relays provide dependable on/off control of industrial devices. Analog Output Module. Four Analog Outputs

Product Specification for SAB-S-MODBUS

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions

IO Module User Manual

APPLICATION NOTE. OJ-DRHX Modbus protocol OJ DRHX A DRIVES PROGRAMME DEDICATED TO ROTARY HEAT EXCHANGERS /17 (OSH) 2017 OJ Electronics A/S

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance.

Manual and Protocol Description

IFC 100 Supplementary instructions

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Vorne Industries. Model 77/232 Serial Input Numeric 3" Display User's Manual

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

RS-485 I/O Modules: ADAM-4000

Installation & Operation Guide

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Measurement Systems Datascan Installation and User Guide

UNIVERSAL TRANSDUCER AR594

mbc082 Bus Converter

GE Fanuc IC694ALG221. Rx3i PacSystem

Millenium 3 logic controllers

TM3AI4 module TM3-4 analog inputs

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

USER MANUAL 2012 V1.1

ABB Drives. User s Manual Modbus Adapter Module FMBA-01

INSTRUCTION SHEET. Eaton Logic Controller DeviceNet Distributed I/O Adapter Module. [Applicable Distributed I/O Adapter Module] ELC-CADNET

User manual RFID IND-M1 Reader

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

GE Fanuc IC694ALG391. Rx3i PacSystem

iologik R1200 Series User s Manual

ABB Drives. User s Manual RS-485 Adapter Board FRSA-00

Communications Quick-Start Guide

NGC-40-BRIDGE. Control and Monitoring Modules for use with the nvent Raychem NGC-40 System Installation Instructions

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Time Counters mini "h", DC Version

Quick Start Installation Guide

Winsonic MODBUS Remote IO user manual Rev. 1.0

PLC-CPU-CM3-SP Series

ELSETA IOMOD 8DI8DO. User manual. Elseta 3/2017 V1.0

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

MDA-8000 DIO User Manual

Safety: UL508 EMC: CE IEC , IEC Vibration: IEC (2 g s during operation) Warranty

Transcription:

Version 1.0 16.05.2014 Manufactured for

Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have been prepared with utmost care by our professionals and serve as a description of the product without incurring any liability for the purposes of commercial law. This information does not release you from the obligation of own judgment and verification. We reserve the right to change product specifications without notice. Please read the instructions carefully and follow the recommendations contained therein. WARNING! Failure to follow instructions can result in equipment damage or impede the use of the hardware or software. Version 1.0-16.05.2014 2 z 17

1. Safety rules Before first use, refer to this manual Before first use, make sure that all cables are connected properly Please ensure proper working conditions, according to the device specifications (eg: supply voltage, temperature, maximum power consumption) Before making any modifications to wiring connections, turn off the power supply 2. Module Features 2.1. Purpose and description of the module The SDM-8AO module has a set of 8 analog outputs that could work as a current output (0-20mA or 4-20mA) or as a voltage output (0-10V). Setting the output curent or voltage value is done via RS485 (Modbus protocol), so you can easily integrate the module with popular PLCs, HMI or PC equipped with the appropriate adapter. This module is connected to the RS485 bus with twisted-pair wire. Communication is via MODBUS RTU or MODBUS ASCII. The use of 32-bit ARM core processor provides fast processing and quick communication. The baud rate is configurable from 2400 to 115200. The module is designed for mounting on a DIN rail in accordance with DIN EN 5002. The module is equipped with a set of LEDs used to indicate the status of inputs and outputs useful for diagnostic purposes and helping to find errors. Module configuration is done via USB by using a dedicated computer program. You can also change the parameters using the MODBUS protocol. Version 1.0-16.05.2014 3 z 17

2.2. Technical Specifications Power Supply Outputs Temperature Connectors Size Voltage Maximum Current * 10-30 VDC; 10-28VAC DC: 52 ma @ 24VDC AC: 62 ma @ 24VAC Maximum power consumption DC: 1,25W; AC: 1,5VA No of outputs 8 Voltage output Current output Current output Measurement resolution ADC processing time Work Storage Power Supply Communication Outputs Configuration Height Length Width 0V do 10V ( resolution 1.5mV) 0mA do 20mA ( resolution 5μA) 4mA do 20mA (value in 1000 steps) (resolution 16μA) 12 bits 16ms / channel -10 C - +50 C -40 C - +85 C 2 pins 3 pins 2x 10 pins Mini USB 110 mm 62 mm 88 mm Interface RS485 Up to 128 devices * Maximum current with active Modbus transmission, all inputs connected and all output active Version 1.0-16.05.2014 4 z 17

2.3. Dimensions of the product Look and dimensions of the module are shown below. The module is mounted directly to the rail in the DIN industry standard. Power connectors, communication and IOs are at the bottom and top of the module. USB connector configuration and indicators located on the front of the module. 91 45 42,3 110 35 110 88 Version 1.0-16.05.2014 5 z 17

3. Communication configuration 3.1. Grounding and shielding In most cases, IO modules will be installed in an enclosure along with other devices which generate electromagnetic radiation. Examples of these devices are relays and contactors, transformers, motor controllers etc. This electromagnetic radiation can induce electrical noise into both power and signal lines, as well as direct radiation into the module causing negative effects on the system. Appropriate grounding, shielding and other protective steps should be taken at the installation stage to prevent these effects. These protective steps include control cabinet grounding, module grounding, cable shield grounding, protective elements for electromagnetic switching devices, correct wiring as well as consideration of cable types and their cross sections. 3.2. Network Termination Transmission line effects often present a problem on data communication networks. These problems include reflections and signal attenuation. To eliminate the presence of reflections from the end of the cable, the cable must be terminated at both ends with a resistor across the line equal to its characteristic impedance. Both ends must be terminated since the direction of propagation is bidirectional. In the case of an RS485 twisted pair cable this termination is typically 120 Ω. 3.3. Setting Module Address in RS485 Modbus Network The following table shows how to set switch to determine the address of the module. The module address is set with the switches in the range of 0 to 127. Addresses From 128 to 255 can by set via RS485 or USB. Switch Address SW1 +1 SW2 +2 SW3 +4 SW4 +8 SW5 +16 SW6 +32 SW7 +64 Ex. if switches 1, 3 and 5 are on than module addres is: Address = 1 + 4 + 16 = 21 Version 1.0-16.05.2014 6 z 17

3.4. Types of Modbus Registers There are 4 types of variables available in the module Typ e Beginning address Variable 1 00001 Digital Outputs 2 10001 Digital Inputs 3 30001 Input Registers 4 40001 Output Registers Access Bit Read & Write Bit Read Registered Read Registered Read & Write Modbus Command 1, 5, 15 2 3 4, 6, 16 3.5. Communication settings The data stored in the modules memory are in 16-bit registers. Access to registers is via MODBUS RTU or MODBUS ASCII. 3.5.1. Default settings You can restore the default configuration by the switch SW8 (see 3.5.2 - Restore the default configuration) Baud rate 19200 Parity Data bits 8 Stop bits 1 Reply Delay [ms] 0 Modbus Type 3.5.2. Restore the default configuration To restore the default configuration: turn off the power turn on the switch SW8 turn on the power when power and communication LED start blinking alternately than turn off the switch SW8 Caution! After restoring the default configuration all values stored in the registers will be cleared as well. No RTU Version 1.0-16.05.2014 7 z 17

3.5.3. Configuration registers Modbus Dec Hex Name Values 40003 2 0x02 Baud rate 40005 4 0x04 Parity 40004 3 0x03 Stop Bits LSB 40004 3 0x03 Data Bits MSB 0 2400 1 4800 2 9600 3 19200 4 38400 5 57600 6 115200 other value * 10 0 none 1 odd 2 even 3 always 1 4 always 0 1 one stop bit 2 two stop bits 7 7 data bits 8 8 data bits 40006 5 0x05 Response delay Time in ms 40007 6 0x06 Modbus Mode 0 RTU 1 ASCII Version 1.0-16.05.2014 8 z 17

4. Switches ON 1 2 3 4 5 6 7 8 Switch Function Description 1 Module address +1 2 Module address +2 3 Module address +4 4 Module address +8 5 Module address +16 6 Module address +32 7 Module address +64 8 Restoring default settings Setting module address from 0 to 127 Restoring default settings (see 3.5.2 - Restore the default configuration). Version 1.0-16.05.2014 9 z 17

5. Front panel removing To remove the panel and gain access to the switch, you must pry open the panel using a thin tool (eg a small screwdriver) as in the picture below. Version 1.0-16.05.2014 10 z 17

6. Indicators Output 1 4 state Communication ON 1 2 3 4 5 6 7 8 mini USB configuration connector Output 5 8 state Power supply Indicator Power supply Communication Outputs state Description LED indicates that the module is correctly powered. The LED lights up when the unit received the correct packet and sends the answer. LED indicates that the output is on. Version 1.0-16.05.2014 11 z 17

7. Module Connection POWER SUPPLY SHIELD Voltage output* Current output* * Each of outputs can be configured as a voltage output or a current output POWER SUPPLY Version 1.0-16.05.2014 12 z 17

8. Setting output mode SDM-8AO Each of outputs can be configured as a voltage outputs or a current outputs. To change the operating mode in addition to configuration changes by using the program or via RS485, also set the jumpers inside the module as shown below. Jumper Description Current output (default) Voltage output 9. Opening the housing 1. Remove the clip by pressing it and moving toward the center of the housing 2. Separate the housing gently tilting the clamps using a thin tool. Version 1.0-16.05.2014 13 z 17

10. Modules Registers 10.1. Registered access Modbus Dec Hex Register Name Access Description 30001 0 0x00 Version/Type Read Version and Type of the device 30002 1 0x01 Switches Read Switches state 40003 2 0x02 Baud rate Read & Write RS485 baud rate 40004 3 0x03 Stop Bits & Data Bits Read & Write No of Stop bits & Data Bits 40005 4 0x04 Parity Read & Write Parity bit 40006 5 0x05 Response Delay Read & Write Response delay in ms 40007 6 0x06 Modbus Mode Read & Write Modbus Mode (ASCII or RTU) 40009 8 0x08 Watchdog Read & Write Watchdog 40033 32 0x20 Received packets LSB Read & Write 40034 33 0x21 Received packets MSB Read & Write 40035 34 0x22 Incorrect packets LSB Read & Write 40036 35 0x23 Incorrect packets MSB Read & Write 40037 36 0x24 Sent packets LSB Read & Write 40038 37 0x25 Sent packets MSB Read & Write No of received packets No of received packets with error No of sent packets 30051 50 0x32 Outputs Read Bit is set if value 0 40053 52 0x34 Analog output 1 Read & Write 40054 53 0x35 Analog output 2 Read & Write 40055 54 0x36 Analog output 3 Read & Write 40056 55 0x37 Analog output 4 Read & Write 40057 56 0x38 Analog output 5 Read & Write 40058 57 0x39 Analog output 6 Read & Write 40059 58 0x3A Analog output 7 Read & Write 40060 59 0x3B Analog output 8 Read & Write 40061 60 0x3C Default output 1 value Read & Write 40062 61 0x3D Default output 2 value Read & Write 40063 62 0x3E Default output 3 value Read & Write 40064 63 0x3F Default output 4 value Read & Write 40065 64 0x40 Default output 5 value Read & Write 40066 65 0x41 Default output 6 value Read & Write 40067 66 0x42 Default output 7 value Read & Write 40068 67 0x43 Default output 8 value Read & Write Value of analog output: in mv for voltage output (max 10240) in μa for current output 0-20mA (max 20480) in for current output 4-20mA (max 1000) Default value of output set when power is on or when watchdog reset occurs Version 1.0-16.05.2014 14 z 17

Modbus Dec Hex Register Name Access Description 40069 68 0x44 Output 1 setting Read & Write Setting of output mode: 70 69 0x45 Output 2 setting Read & Write 40071 70 0x46 Output 3 setting Read & Write 40072 71 0x47 Output 4 setting Read & Write 40073 72 0x48 Output 5 setting Read & Write 40074 73 0x49 Output 6 setting Read & Write 40075 74 0x4A Output 7 setting Read & Write 40076 75 0x4B Output 8 setting Read & Write 0 output disable 1 voltage output 2 current output 0-20mA 3 current output 4-20mA Caution! For the change to take effect, you must also set the jumper inside the module. 10.2. Bit access Modbus Address Dec Address Hex Address Register name Access 801 800 0x320 Output 1 Read 802 801 0x321 Output 2 Read 803 802 0x322 Output 3 Read 804 803 0x323 Output 4 Read 805 804 0x324 Output 5 Read 806 805 0x325 Output 6 Read 807 806 0x326 Output 7 Read 808 807 0x327 Output 8 Read Description If voltage or current is greater than 0 then according bit is set. Version 1.0-16.05.2014 15 z 17

11. Configuration software Modbus Configurator is software that is designed to set the module registers responsible for communication over Modbus network as well as to read and write the current value of other registers of the module. This program can be a convenient way to test the system as well as to observe real-time changes in the registers. Communication with the module is done via the USB cable. The module does not require any drivers. USB PC Configurator is a universal program, whereby it is possible to configure all available modules. Version 1.0-16.05.2014 16 z 17

Table of content 1. Safety rules...3 2. Module Features...3 2.1. Purpose and description of the module...3 2.2. Technical Specifications...4 2.3. Dimensions of the product...5 3. Communication configuration...6 3.1. Grounding and shielding...6 3.2. Network Termination...6 3.3. Setting Module Address in RS485 Modbus Network...6 3.4. Types of Modbus Registers...7 3.5. Communication settings...7 3.5.1. Default settings...7 3.5.2. Restore the default configuration...7 3.5.3. Configuration registers...8 4. Switches...9 5. Front panel removing...10 6. Indicators...11 7. Module Connection...12 8. Setting output mode...13 9. Opening the housing...13 10. Modules Registers...14 10.1. Registered access...14 10.2. Bit access...15 11. Configuration software...16 Manufactured for: Aspar s.c. ul. Kapitańska 9 81-331 Gdynia POLAND ampero@ampero.eu www.ampero.eu tel. +48 58 351 39 89; +48 58 732 71 73 Version 1.0-16.05.2014 17 z 17

Output No Current output (default) Voltage output 1 2 3 4 5 6 7 8