The LSI Gateway. GS220, GS221, GS222 series - LSI gateways. Features:

Similar documents
Applications: Industrial Automation, Cranes, Hoists, Utility Vehicles, Off-highway, Ag, and Forestry Equipment

Applications: Industrial Automation, Cranes, Hoists, Utility Vehicles, Off-highway, Ag, and Forestry Equipment

Applications: Power generator sets and control systems for industrial engine applications.

Discrete I/O P/N: AXDIO inputs, 8 relay outputs, SAE J1939 with Electronic Assistant

GW1101 Rev Introduction. DASH7 - IP Gateway for Industrial Applications. Applications. Description. 868MHz / 915MHz.

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

Migration from 9XStream-PKG Modem to XBee-PRO XSC RF Modem

Inclination sensors 1-dimensional, measuring range

Applications: Industrial Automation, Cranes, Hoists, Utility Vehicles, Off-highway, Ag, and Forestry Equipment

WIRELESS GATEWAY DUOS

Product description Rev. 3 11/06/14

VDC. Wireless VDC Voltage Meters. The Leader in Low-Cost, Remote Monitoring Solutions. Monnit Sensor Core Specifications. General Description

Webdom Datalogger 1.5

Inclination sensors 2-dimensional, measuring range up to ±90

Wireless Low Temperature Sensor

SCALE LINK - SL2 Technical Manual

Ordering Part Numbers: TECHNICAL DATASHEET #TDAX BLDC MOTOR CONTROLLER P/N: AX100260

Wireless High Temperature Sensor

Team 2228 CougarTech 1. Training L2. Software Environment

Bel Power Solutions AC Power Distribution Unit (PDU) is used to distribute AC voltage in IT Racks following the Open Rack specification.

WIRELESS SERIES Single or Dual Axis MEMS Inclinometer

PRELIMINARY. Preliminary Technical Datasheet #TDAX Discrete I/O P/N: AX inputs, 8 relay outputs, SAE J1939 with Electronic Assistant

FTM84/85 Feature Application. Temperature & Humidity / Flow Measuring Specialist

Reindeer Technologies Pvt Ltd Excellence through Innovation

TXP3500/4000 Series AC-DC Industrial PSU

RN-134. WiFly GSX Super Module SuRF Board. Features. Description. Applications. ~ page 1 ~ rn-134-ds v1.

ACS HEAVY DUTY INCLINOMETER SAE J1939 INTERFACE

LVX Control Unit. Features:

CONCEPT P/N: AX Concept TECHNICAL DATASHEET #TDAX Analog Input CAN Controller CAN (SAE J1939 or CANopen ) with Electronic Assistant

TECHNICAL PRODUCT DATASHEET

Features. Preliminary. Industrial IEEE b/g/n with 2x10/100Base-T(X) 1x RS-232/422/485 IoT LTE LPWAN Gateway. Introduction

TECHNICAL DATASHEET Heavy Duty - Absolute Encoder AR 62/63

Applications: Stationary, portable power generator sets Genset control systems

TECHNICAL DATASHEET #TDAX Analog Signal Output CAN Controller (SAE J1939)

Wireless Asset Sensor

PHASED OUT PRODUCT DC2. Microcontroller DESCRIPTION FEATURES ORDERING INFORMATION. BLN Issued: June 1995

WE CONNECT REAL WORLD STRUCTURAL MONITORING SMART SENSORS SOFTWARE CLOUD WIRELESS INTERFACE TO THE

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

Installation Instructions for: Channel Thermocouple Amplifier

T1K MODBUS Base Controller Specifications

Dearborn Protocol Adapter (DPA) and PLC TestCon Pinouts and Industry Connectors Reference Guide Including the J1939 Type-2 Connector

EA500. Installation Instructions Transponder

DeviceNet Master (Scanner) HE800DNT450 / HE-DNT450* DeviceNet Communications * HE- denotes plastic case.

Accessories: PL-DTM06-12SA-12SB Mating Plug Kit (1 DTM06-12S, DTM06-12SB, 2 W12S, 24 contacts) Electronic Assistant Configuration KIT: AX070502

Specification G-NSDOG2-200

WLS-TC Specifications

The 2U package makes the unit suitable for using in workstations, storage systems, racks for industrial and many other applications.

RN-174 WiFly Super Module

Product Specification SmartHarness Electronic Control Module 0610 (SH-ECM-0610)

Wireless Dry Contact Sensor

Wireless Dry Contact Sensor

TECHNICAL DATASHEET #TDAX050000K CAN

Wireless Activity Sensors

RC1170-RC232 USER MANUAL

A-307. Mobile Data Terminal. Android OS Platform Datasheet

Aarlogic TER-GX910. Product description. Rev.9 17/03/2013

GW-7228 J1939/Modbus RTU Slave Gateway

NPort Z2150/Z3150 Series

Industrial Media Converters

CAN485. Wall Mounting CAN to RS-485 Interface Converter. Support data conversion between 1 CAN port and 1 RS-485 serial port

RN-174. WiFly GSX Super Module. Features. Description. Applications. rn-174-ds v1.1 4/20/2011

D-SERIES INCLINOMETER

ALPW-BLEM103 Datasheet 1.0 Bluetooth Low Energy HCI

ATTINGIMUS RADAR AT-CAS S

Smart Wireless THUM Adapter

TEMPERATURE - HUMIDITY ELEKTRONIK EE08

DVC700 Series. Programmable System Controller

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) SUITABLE FOR EXTERNAL DISTRIBUTION

RN-174. WiFly GSX Super Module. Features. Description. Applications. rn-174-ds v1.1 1/24/2011

Wireless Receiver W/ USB Output BA/RCVxxx-USB Installation and Operating Instructions

Introduction Video Camera Support Option TREQ Platform Datasheet. January Rev. 2 A-317 Video Getting Started Guide 1 / 6

RN-174. WiSnap M2 Super Module. Features. Description. Applications. ~ page 1 ~ rn-174-ds v1.1 6/1/2011

TB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.

SST-2450 Wireless Modem User s Manual

NEW! ZERO-UP. Control Flexibility for Worldwide Applications 200W/400W/800W. Built-in RS232 & RS485 Interface with GPIB optional.

LED55WPG Programmable LED Driver

Moxa TCC-100 Series Hardware Installation Guide

SMI-100 Stack Monitoring Interface Installation & Operation Manual

GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway

intelligent monitoring solutions C A N t r a k C O N F I G U R A B L E I N P U T M O D U L E ( C C I M ) I N S T A L L A T I O N M A N U A L

Mobileye EyeCAN (with CAN sniffer cable) User Guide

MOXA EtherDevice Switch

COR Series Router IBR900/IBR950 AND IBR1100/IBR1150

Media Converters. Media Converters. Product Selection Guides

Skywire BeagleBone Black Cape Data Sheet

KCD-HP. KCD-HP200x, 300X. [Figures] Top : 1% Sensor probe Bottom left : 10% / 20% Sensor probe Bottom right : Holding bracket(optional) Measurement

Features and Benefits. Certifications

SST200 Inclinometer SST500 SST400 SST300 SST200 SST100 SST30 SST20 SST900 SSG200 SSG100 SST830 SST820 SST810 SST800. Features.

RN-174. WiFly GSX Super Module. Features. Description. Applications. rn-174-ds v1.1 3/3/2011

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

MGate 5102-PBM-PN Series

Wireless Dry Contact Sensor

CBL Starter Cable Kit for DuraNAV System

CM5000 DATASHEET v0.1

NPort W2150A/W2250A Series Quick Installation Guide

Technical Data Sheet OPUS A3 STANDARD Basic TDS OPUS A3sB,

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

955S BRIK. Series 955S Brik. Smart BRIK LDT ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS. Linear Displacement Transducer

Transcription:

Features: Receive all LSI standard radio communications Configurable to be the master of up to 30 sensors, or to listen to unlimited number of devices. Input power supply: 9 to 30V, or USB port, or other depending on model number, current requirement of 200mA maximum. Could output data on CAN bus, J1939 networks, RS232 or USB. Industrial (-40 C to 85 C) tested industrial temperature ratings. Humidity 0 to 100%RH. IP65 water resistant aluminum enclosure. Potted electronics for increase water proof protection General Description: The LSI Gateway receives readings from any LSI wireless sensors. The readings could be forwarded to other devices the Gateway is connected to, such as a CAN bus, J1939 network, RS232 PLC or computer, USB ports of computers, etc... Applications: Remote sensor reading Replacing wired sensors by wireless sensors with easy integration in current system. Datalogger / recorder : to record wireless sensor readings on file Live alarm monitoring Forward wireless sensor readings to a PLC via RS232 port Forward wireless sensor readings to an embedded computer This photo is an illustration of the gateway, the actual connectors and cables will depend on the part number. The radio operates license free at 900MHz in North America or 869MHz in Europe. Every piece of equipment is industrially hardened and rigorously tested to withstand harsh environment, shocks and thermal extremes. Information furnished by LSI is believed to be accurate and reliable. L S I I n d u s t r i a l D i v i s i o n R e v 1. 4 P a g e 1 o f 9

Table of contents Features:... 1 Applications:... 1 General Description:... 1 Table of contents... 2 Specifications... 3 Absolute maximum ratings... 3 Certifications... 3 Ordering information... 3 Applications details... 4 GS220 Gateway with USB port works with a PC software... 4 GS221 Gateway with CAN bus interface... 6 GS221 Gateway with CAN bus and J1939... 6 GS222 Gateway with RS232 output... 8 Dimensions... 9 Revision History... 9 L S I I n d u s t r i a l D i v i s i o n R e v 1. 4 P a g e 2 o f 9

Specifications The LSI Gateway Parameter Test Condition Min Typ Max Unit Number of sensors Maximum number of sensors in master mode 1 32 Maximum number of sensors in listening mode 1 1000 Power Supply GS220 (from USB port) GS221 & GS222 on 9V to 30Vdc power source 60 200 ma 60 200 ma Absolute maximum ratings Parameter Test Condition Min Typ Max Unit Input voltage GS221-GS222 9 12 or 30 V 24 Temperature range Operating -40 +60 ºC Temperature range Storage -50 +70 ºC Certifications FCC / IC / CE certification ETSI 300-220-1, 300-220-3, EN 301 489-3 EN61000-4, EN60079-0, EN60079-11, EN60079-26 Ordering information Model GS22x-nn GS22x-nn-ce Description 915MHz frequency band for North America 868MHz frequency band for Europe x represents the signal output option: GS220=USB only, GS221=CAN Bus+USB, GS222=RS232+USB, etc... nn represents other options: such as wires instead of connectors, wall plug transformers instead of bare wires, etc.. P/N Description Connectors and cables GS220-01 Datalogger to PC or laptop, listener, 100+ sensors USB connector only GS220-02 Datalogger to PC or laptop, listener, to add external antenna USB connector + RP-SMA antenna connector GS220-04 Datalogger & Repeater with 35 ft power cable USB connector & power cable for Repeater GS221-01 CAN bus wind speed receiver 1 cable for both: power & CAN bus. GS221-04 CAN bus with J1939 protocol Std connector for J1939 GS221-05 CAN bus & power supply on a M12 connector M12 connector with 31 of cable GS222-01 RS232 Datalogger to PC or laptop, listener, 100+ sensors, wall power supply. RS232 DB9-F connector, wall plug transformer for 120/220Vac GS222-05 RS232 with two cables Two bare wires cables, one for power (9 to 36V) and one for PLC. L S I I n d u s t r i a l D i v i s i o n R e v 1. 4 P a g e 3 o f 9

Applications details GS220 Gateway with USB port works with a PC software Two operating modes exist: Datalogger mode and Master mode The LSI Gateway Datalogger mode: A receiver card in datalogger mode listens to everything around without a need to setup specific IDs. The PC software will show sensors as they are detected. On the screen, the values change in real time, live, as shown in the picture below. Alternatively, a graphical user interface Example of application with the Dashboard software to monitor crane sensors: When a receiver card is in listen mode, the sensors must be in their normal wake-up condition, not in sleep mode. Two ways of keeping sensors awake when needed exist: All sensors could have a master unit, waking them up when required Sensors could be in the dual mode, an operating mode without a master where the sensor broadcast to everything around. This de-activate their sleep condition. L S I I n d u s t r i a l D i v i s i o n R e v 1. 4 P a g e 4 o f 9

Master mode: Sensors, or nodes, could be configured, adjusted, calibrated. The picture below illustrates a receiver card prepared to listen to a load sensor ID # 16191. Because the receiver card is the master of this sensor, the sensor will enter low power sleep mode when the receiver card is off. On power-up, the receiver card will wake-up the sensor. In master mode, the receiver card is limited to about 32 sensors. The configurator software allows a receiver card to setup internal parameters internal to the sensors: L S I I n d u s t r i a l D i v i s i o n R e v 1. 4 P a g e 5 o f 9

GS221 Gateway with CAN bus interface The LSI Gateway CAN bus (Controller Area Network) is a bus standard designed to allow microcontrollers and devices to communicate with each other. It has been designed specifically for automotive applications but is now used in industrial and medical applications. The LSI Gateway will communicate with other devices on a CAN bus network. It could forward the information coming wirelessly from other radio sensors such as load cells, inclinometers, etc With the free LSI configurator software, it is possible to change how the data will be output on a CAN bus. Sensors readings could be sent based on a timer or based on events, such as a change of load. The default is live, which means that every update received from a sensor will be forwarded on CAN bus. CAN bus source and destination address number could be set manually. The Configurator software allows the setup of the CAN bus operation by connecting the gateway to a PC USB port. GS221 Gateway with CAN bus and J1939 J1939 uses the CAN bus as the communication link. It is built over CAN bus. J1939 is the vehicle bus standard used for communication and diagnostics among vehicle components, originally by the car and heavy duty truck industry in the United States. J1939 is used in the commercial vehicle area for communication throughout the vehicle. SAE, the Society of Automotive Engineers administers the J1939 standard. The J1939 receiver card uses PGN numbers for the communication on the network. Consult these documents for details: Gateway J1939 specifications.pdf Gateway CANbus specifications.pdf J1939 Receiver Information Sheet.pdf L S I I n d u s t r i a l D i v i s i o n R e v 1. 4 P a g e 6 o f 9

Wiring GS221-01: one cable for power and the CAN bus network wires Wire color Black Red Blue Green White Description Ground Power supply, 9 to 36 volts CAN bus ground CAN-H CAN-L Bare wires Wiring GS221-04: standard 3-pin Deutsch J1939 connector J1939 connector 15 ft power cable: Pin A B C Signal CANL CANH GND Signal Ground Power (9-30V) Wire color Blue Red Power J1939 USB Wiring GS221-05: one M12 connector for power and the CAN bus network singals Wire Description Cable length: 31 1 Shield 2 Power 3 Gnd 4 CAN_H 5 CAN_L L S I I n d u s t r i a l D i v i s i o n R e v 1. 4 P a g e 7 o f 9

GS222 Gateway with RS232 output The LSI Gateway RS232 was a serial communication port present in most PC computers before 2005. It is still widely used on PLC or other electronic controllers. As for the CAN bus interface, the Configurator software provides a way to define the data format on the RS232. The GS222-01 has a female connector mating the one shown above. Applications: this output is often wanted to interface with existing computer, consoles or PLC (Programmable Logic Controller) Wiring GS222-01: this part number has a DB9 connector at the end of a cable Cable Description 1 6 ft long cable with wall plug transformer 2 6 ft long cable with DB9-F female connector Wiring GS222-05: this part number has bare wires instead of the DB9 connector Cable Cable 1 15 ft long 2 wires Cable 2 15 ft long 4 wires Wire Color Red Blue Red Green Blue Description Power supply 9 to 30V Ground RS232 gateway TX* signal RS232 gateway RX signal RS232 ground Yellow Not used *Note the gateway TX signal means transmit and must connect to the receive wire of the PC or PLC. L S I I n d u s t r i a l D i v i s i o n R e v 1. 4 P a g e 8 o f 9

Dimensions The picture is an illustration of the gateway, the actual connectors and cables will depend on the part number. Revision History Rev 1.0 Release Rev 1.1 Minor update to p/n Rev 1.2 Update to wiring description Rev 1.3b Typo corrected Rev 1.4 Update to photo renderings L S I I n d u s t r i a l D i v i s i o n R e v 1. 4 P a g e 9 o f 9