Corso di laurea in Fisica A.A Fisica Medica 5 SPECT, PET

Similar documents
Introduction to Positron Emission Tomography

Medical Imaging BMEN Spring 2016

Fast Timing and TOF in PET Medical Imaging

Positron Emission Tomography

Cherenkov Radiation. Doctoral Thesis. Rok Dolenec. Supervisor: Prof. Dr. Samo Korpar

Emission Computed Tomography Notes

Diagnostic imaging techniques. Krasznai Zoltán. University of Debrecen Medical and Health Science Centre Department of Biophysics and Cell Biology

Implementation and evaluation of a fully 3D OS-MLEM reconstruction algorithm accounting for the PSF of the PET imaging system

in PET Medical Imaging

SNIC Symposium, Stanford, California April The Hybrid Parallel Plates Gas Counter for Medical Imaging

Introduction to Emission Tomography

Review of PET Physics. Timothy Turkington, Ph.D. Radiology and Medical Physics Duke University Durham, North Carolina, USA

Positron. MillenniumVG. Emission Tomography Imaging with the. GE Medical Systems

Nuclear Medicine Imaging

FRONT-END DATA PROCESSING OF NEW POSITRON EMIS- SION TOMOGRAPHY DEMONSTRATOR

Continuation Format Page

CHAPTER 11 NUCLEAR MEDICINE IMAGING DEVICES

Constructing System Matrices for SPECT Simulations and Reconstructions

An educational tool for demonstrating the TOF-PET technique

3-D PET Scatter Correction

Medical Imaging Modalities

BME I5000: Biomedical Imaging

COUNT RATE AND SPATIAL RESOLUTION PERFORMANCE OF A 3-DIMENSIONAL DEDICATED POSITRON EMISSION TOMOGRAPHY (PET) SCANNER

Corso di laurea in Fisica A.A Fisica Medica 4 TC

218 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 44, NO. 2, APRIL 1997

Digital Image Processing

Conflicts of Interest Nuclear Medicine and PET physics reviewer for the ACR Accreditation program

Fits you like no other

SUV Analysis of F-18 FDG PET Imaging in the Vicinity of the Bladder. Colleen Marie Allen. Graduate Program in Medical Physics Duke University

REMOVAL OF THE EFFECT OF COMPTON SCATTERING IN 3-D WHOLE BODY POSITRON EMISSION TOMOGRAPHY BY MONTE CARLO

Fits you like no other

Time-of-Flight Technology

James R Halama, PhD Loyola University Medical Center

Extremely Fast Detector for 511 kev Gamma

8/2/2017. Disclosure. Philips Healthcare (Cleveland, OH) provided the precommercial

Semi-Quantitative Metrics in Positron Emission Tomography. Michael Adams. Department of Biomedical Engineering Duke University.

Tomographic Reconstruction

Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition

In-vivo dose verification for particle therapy

INVESTIGATION OF ACCURACY IN QUANTITATION OF 18 F-FDG CONCENTRATION OF PET/CT. A Thesis

AX-PET : A novel PET concept with G-APD readout

Performance optimization of a PET insert for simultaneous. breast PET/MR imaging

PURE. ViSION Edition PET/CT. Patient Comfort Put First.

Introduction to Biomedical Imaging

SPECT QA and QC. Bruce McBride St. Vincent s Hospital Sydney.

Image reconstruction for PET/CT scanners: past achievements and future challenges

MOHAMMAD MINHAZ AKRAM THE EFFECT OF SAMPLING IN HISTOGRAMMING AND ANALYTICAL RECONSTRUCTION OF 3D AX-PET DATA

Investigations of a novel small animal PET scanner with depth of interaction using GATE and a newly developed data rebinning application

The great interest shown toward PET instrumentation is

The Effects of PET Reconstruction Parameters on Radiotherapy Response Assessment. and an Investigation of SUV peak Sampling Parameters.

Acceleration of an image reconstruction algorithm for Positron Tomography using a Graphics Processing Unit

Study of a High-Resolution PET System Using a Silicon Detector Probe TESIS DOCTORAL UNIVERSITAT DE VALENCIA

A full-brain PET scanner based on the AX-PET concept: Monte Carlo performance study

Performance Evaluation of radionuclide imaging systems

Effects of system geometry and other physical factors on photon sensitivity of high-resolution

Investigations of a novel small animal PET scanner with depth of interaction using GATE and a newly developed data rebinning application

JOHN M. OLLINGER AND JEFFREY A. FESSLER

Detection of Lesions in Positron Emission Tomography

Characterization of a Time-of-Flight PET Scanner based on Lanthanum Bromide

Outline. What is Positron Emission Tomography? (PET) Positron Emission Tomography I: Image Reconstruction Strategies

Technological Advances and Challenges: Experience with Time-Of-Flight PET Combined with 3T MRI. Floris Jansen, GE Healthcare July, 2015

Determination of Three-Dimensional Voxel Sensitivity for Two- and Three-Headed Coincidence Imaging

Medical Images Analysis and Processing

Simulations in emission tomography using GATE

Iterative SPECT reconstruction with 3D detector response

Goals of this presentation

Detector simulations for in-beam PET with FLUKA. Francesco Pennazio Università di Torino and INFN, TORINO

SPECT: Physics Principles and Equipment Design

Evaluation of Centrally Located Sources in. Coincidence Timing Calibration for Time-of-Flight PET

Validation of PET/CT dataset for radiation treatment planning

A. Specific Aims. Principal Investigator/Program Director (Last, First, Middle): Kagan, Harris

Quantitative capabilities of four state-of-the-art SPECT-CT cameras

Hybrid Imaging for Patient-Specific Dosimetry in Radionuclide Therapy

Workshop on Quantitative SPECT and PET Brain Studies January, 2013 PUCRS, Porto Alegre, Brasil Corrections in SPECT and PET

ANALYSIS OF CT AND PET/SPECT IMAGES FOR DOSIMETRY CALCULATION

The SIMIND Monte Carlo Program Version /12/2017

Performance Evaluation of the Philips Gemini PET/CT System

Reconstruction in CT and relation to other imaging modalities

Evaluation of attenuation and scatter correction requirements in small animal PET and SPECT imaging

STATISTICAL PERFORMANCE EVALUATION, SYSTEM MODELING, DISTRIBUTED COMPUTATION AND SIGNAL PATTERN MATCHING FOR A COMPTON MEDICAL IMAGING SYSTEM

RICE UNIVERSITY. Optimization of Novel Developments in Positron Emission Tomography (PET) Imaging. Tingting Chang

Iterative and analytical reconstruction algorithms for varying-focal-length cone-beam

Position and Energy Reconstruction from Scintillation Light in a Liquid Xenon Gamma Ray Detector designed for PET

If it matters to you, it matters to us

Modeling and Incorporation of System Response Functions in 3D Whole Body PET

664 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 52, NO. 3, JUNE 2005

Design of a Real Time FPGA based Three Dimensional Positioning Algorithm

Index. aliasing artifacts and noise in CT images, 200 measurement of projection data, nondiffracting

Motion Correction in PET Image. Reconstruction

X-ray simulation and applications

INTERNATIONAL STANDARD

PERFORMANCE MEASUREMENTS OF POSITRON EMISSION TOMOGRAPHS

Monte-Carlo Modeling of Scintillator Crystal Performance for Stratified PET Detectors with DETECT2000

Development of Spect and Ct Tomographic Image Reconstruction

Respiratory Motion Compensation in 3D. Positron Emission Tomography

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

Lecture 6: Medical imaging and image-guided interventions

ISO ISO ISO OHSAS ISO

Computational Medical Imaging Analysis

Simulation of Mammograms & Tomosynthesis imaging with Cone Beam Breast CT images

Transcription:

Corso di laurea in Fisica A.A. 2007-2008 Fisica Medica 5 SPECT, PET

Step 1: Inject Patient with Radioactive Drug Drug is labeled with positron (β + ) emitting radionuclide. Drug localizes in patient according to metabolic properties of that drug. Trace (pico-molar) quantities of drug are sufficient. Radiation dose fairly small (<1 rem). Drug Distributes in Body

Ideal Tracer Isotope Interesting Biochemistry Easily incorporated into biologically active drugs. 1 Hour Half-Life Maximum study duration is 2 hours. Gives enough time to do the chemistry. Easily Produced Short half life local production. 18 18 F 2 hour half-life 15 15 O, 11 11 C, 13 13 N 2, 2, 20, & 10 minute half-lives

Step 2: Detect Radioactive Decays Ring of Photon Detectors Radionuclide decays, emitting β +. β + annihilates with e from tissue, forming back-to-back 511 kev photon pair. 511 kev photon pairs detected via time coincidence. Positron lies on line defined by detector pair (known as a chord or a line of response or a LOR). Detect Pairs of Back-to-Back 511 kev Photons

Multi-Layer PET Cameras Scintillator Tungsten Septum Lead Shield Can image several slices simultaneously Can image cross-plane slices Can remove septa to increase efficiency ( 3-D PET ) Planar Images Stacked to Form 3-D Image

Step 3: Reconstruct with Computed 2-Dimensional Object Tomography 1-Dimensional Vertical Projection 1-Dimensional Horizontal Projection By measuring all all 1-dimensional projections of of a 2-dimensional object, you can reconstruct the object

Why Do Computed Tomography? Planar X-Ray Computed Tomography Separates Objects on Different Planes

Attenuation Correction β + Source Use external β + source to measure attenuation. Attenuation (for that chord) same as for internal source. Source orbits around patient to measure all chords. Measure Attenuation Coefficient for Each Chord Obtain Quantitative Images

Time-of-Flight Tomograph c = 1 foot/ns 500 ps timing resolution 8 cm fwhm localization Can localize source along line of flight. Time of flight information reduces noise in images. Time of flight tomographs have been built with BaF 2 and CsF. These scintillators force other tradeoffs that reduce performance. Not Compelling with Present Technology...

PET Images of Cancer Brain Heart Bladder Treated Tumor Growing Again on Periphery Metastases Shown with Red Arrows Normal Uptake in Other Organs Shown in Blue

PET Cameras Patient port ~60 cm diameter. 24 to 48 layers, covering 15 cm axially. 4 5 mm fwhm spatial resolution. ~2% solid angle coverage. $1 $2 million dollars.

Early PET Detector Element BGO Scintillator Crystal (Converts γ into Light) 10 30 mm high (determines axial spatial resolution) 3 10 mm wide (determines in-plane spatial resolution) 30 mm deep (3 attenuation lengths) Photomultiplier Tube (Converts Light to Electricity)

Modern PET Detector Module 4 PMTs (25 mm square) 50 mm Saw cuts direct light toward PMTs. Depth of cut determines light spread at PMTs. Crystal of interaction found with Anger logic (i.e. PMT light ratio). 50 mm 30 mm BGO Scintillator Crystal Block (sawed into 8x8 array, each crystal 6 mm square) Good Performance, Inexpensive, Easy to Pack

Radial Elongation Penetration of 511 kev photons into crystal ring blurs measured position. Radial Projection Tangential Projection Effect variously known as Radial Elongation, Parallax Error, or Radial Astigmatism. Can be removed by measuring depth of interaction.

No Pair Production / EM Showers Scatter Length 10 cm Compton scatter in patient produces erroneous coincidence events. ~15% of detected events are scattered in 2-D PET (i.e. if tungsten septa used). ~50% of events are scattered in 3-D Whole Body PET. Compton Scatter is Important Background Use Energy to Reject Scatter in Patient