XW3B. Connector Terminal Boxes. Ratings and Specifications. Compatible Connectors. Materials and Finish

Similar documents
Round Water-resistant Connectors (M12) XS2

Round Water-resistant Connectors (M8) XS3

XS2. Water- and Environmentresistive. Wiring and Maintenance Effort. Sensor I/O Connectors (M12) Construction (XS2G Soldering Plug Connector Assembly)

M8 & M12 Connector Cables

XS3. Small Round Water-resistive Connectors. Round Water-resistant Connectors (M8/S8) Pin Arrangement (Engaged Side)

BGS (at min. setting) BGS (at max. setting)

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

E4PA. Ultrasonic Displacement Sensor. Ordering Information

onlinecomponents.com

XC5. DIN-style Twin-contact Connectors. Expanding the DIN Concept. Materials and Finish. Ratings and Characteristics

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

Pin plunger D2JW-011 D2JW-011-MD. Short hinge lever D2JW-01K1A1 D2JW-01K1A1-MD. Hinge lever D2JW-01K11 D2JW-01K11-MD

E4PA-N. Application Examples. Features. Ultrasonic Displacement Sensor. Now, more advanced with a new mutual interference prevention function.

Without Indicator. With Indicator Model XM9B XM9B Contact Plating Specification 4: Gold Flash Plating

650 VAC for 1 min (leakage current: 1 ma max.) Phosphor bronze/ Brass/nickel base, Brass/nickel base, 0.4-μm gold nickel base, 0.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

XC7. DIN Sequence Connectors. An improved DIN-standard Sequence. Connectors. connectors. Ratings and Characteristics. Materials and Finish

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Y.COM.TW WWW. 0Y.COM.TW WW. Text D-Sub Connectors - XM3-L/XM2-L/XM4K/XM4L

Phosphor bronze/ Brass/nickel base, Brass/nickel base, 0.4- m gold nickel base, 0.4- nickel base, mm gold plating. plating m gold plating

XS2. Water- and Environment-resistive FA Connectors Save Wiring and Maintenance Effort. Round Water-resistant Connectors (M12 Threads)

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

14CESeries. Miniature Pre-Leaded Vertical Enclosed Switches

1 XS3W-M R Robot cable

Inductive Proximity Sensor

D2SW-3L1HS D2SW-01L1HS

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

NPN output PNP output Cord connection Cord length: 2 m Through-beam 7 m Light-ON. 2 m. (selectable by wiring) Diffuse reflective 0.

Long-distance Photoelectric Sensor with Built-in Amplifier. Connection method Sensing distance. --- Retro-reflective. (500 mm) Terminal block ---

RM84 miniature relays

masterelectronics.com onlinecomponents.com

Operation mode. Output configuration. Relay DC SSR. Light-ON Dark-ON (switch selectable) Relay DC SSR. Relay DC SSR

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4. 40 XW2B-40G5 Flat Cable Connectors

Chemical Resistant Inductive Prox

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4 40 XW2B-40G5 *1 50 XW2B-50G5 60 XW2B-60G5 40 XW2B-40G5-T

Basic Switch. Pin plunger Short hinge Hinge lever Long hinge lever Simulated hinge Short hinge Hinge roller lever lever roller lever lever

Actuator Terminal Model

Inductive Proximity Sensor

E2K-X4ME1 2M E2K-X4ME2 2M

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are

XH2. Half-pitch Board-to-Board Connectors

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

Switches and Indicators 84

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

Model Number Structure

Contact form. Operating Force. Plunger SPDT 204g Dust- Proof (in closed position) Plunger SPST-NC 204g Dust- Proof (in closed position)

the Interactive Catalog

Appearance Sensing distance Output configuration Operation mode Model NO E2EQ-X7D1 2M

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

Thread length (overall length) material

Contact form. Operating Force. SPDT 25g Unsealed Solder / 187 Quick Connect. SPDT 50g Unsealed Solder / 187 Quick Connect

16 g SS-01GL-FD SS-01GL-F SS-01GL-FT 50 g SS-01GLD SS-01GLD1 SS-01GLD2 SS-01GL SS-01GLT Simulated roller lever

ITS-Z0344 Half Pitch Interface Connectors

must Operate Voltage (V)

Absolute Rotary Encoder E6C-N. Ordering Information. Ideal for Stepping Motor Tripping Detection and Position Control of Loaders or Unloaders

RFC CONNECTOR 2J Specifications. Standards. Disconnectable Crimp style Wire-to-wire connectors

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Miniature Basic Switch

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m)

CJ series Ergonomic multifunction joysticks

CNE. Wire mount plug Wire mount socket Item. Type Wire mount plug Wire mount socket Board mount socket Model CNE-P - CNE-S - CNE-B

Plug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs

Industrial Ethernet Cables XS5/XS6

AMP Drawer Series Connectors Miniature Power Drawer (MPD) Connectors

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

(Applicable output load) to 264 (see note 2) (see note 1) (2Aat75to264VAC) G3R-202SLN-US PCB Yes 2 A at 100 to 120 VDC. (2 A at 75 to 132 VDC)

PRODUCT SPECIFICATION

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

ORDERING INFORMATION: P/N 5 2 M D - x x M x HALF PITCH (1.27MM) D-SUB. IDC TYPE CABLE MALE CONNECTOR WITHOUT HOOD C0201

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction.

RFC CONNECTOR 2J Specifications. Standards. Disconnectable Crimp style Wire-to-wire connectors

IP68 Sealed - Mini USB Buccaneer

1Certified LR R Inner-housing lock. Outer-housing lock

Ordering Information. Smart Sensors (Inductive Displacement Type) ZX Series. Sensors

Quick-connect terminals (#110)

Information. EX260 Integrated Type (For Output) Serial Transmission System 5 Port Solenoid Valve mm. Series SY/SV/VQC/S0700

PRODUCT SPECIFICATION

Mini Photoelectric Sensor

Long Sensing-distance Capacitive Separate Amplifier Proximity Sensor E2J-W10MA 1M E2J-W20MA 1M. E2J-JC4A Amplifier Unit

Sensing method Appearance Connection method Sensing distance Part number NPN output PNP output Through-beam Prewired (2 m) E3Z-T61A E3Z-T81A 10 m

Cylindrical Proximity Sensor

Vane Type Photoelectric Switches with Self-contained Amplifier

MICRO SWITCH Sealed Subminiature Basic Switches. ZW Series. Datasheet

Inductive Proximity Sensor

PA FAMILY SERIES/PA PAF PAL CONNECTOR

Peripheral Devices for Environment-resistive Slaves

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

NO: PH-185 PRODUCT: E3JK Photoelectric Sensors DATE: May 2014 TYPE: Discontinuation Notice

3 Series Thumbwheel Switches

D5B. Detects Objects in Multiple Directions with High Sensitivity, Ideal for Robotics. Mechanical Touch Switch. Model Number Structure

Long-distance Photoelectric Sensor with Built-in Amplifier. Connection method Sensing distance. E3G-R13 2M --- Retro-reflective.

E3X-NA. Adjuster type standard that is the culmination of true ease and simplicity. Super Manual Fiber Amplifier. Features

DUBOX SHUNTS BOARD/WIRE-TO-BOARD CONNECTORS FEATURES & BENEFITS. Dual-beam contacts for added reliability

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

Standard Series Standard

400 Series Buccaneer BUCCANEER FOR POWER. IP68 rating tested at 1.054kg/sq cm (15lb/sq in) 10m depth for 2 weeks

Transcription:

es XWB Series Includes New Lightweight, Low-profile Connector Terminal Boxes for Use Outside of Control Boxes to Centralize I/O with Reduced Labor and Greater Environmental Resistance Tough model with a significantly lower profile satisfies IP. Available for Photoelectric s, Proximity s, and es with I/O (M). Increased rated current, with added ground terminal, and compatible with valves and solenoids. Incorporates power and operation indicators. Uses a single mounting method regardless of the number of ports, which ensures easy system expansion. / Ratings and Specifications Rated current A/port (signal lines) A/box (power lines) Rated voltage 0 to 0 VDC Contact resistance 0 MΩ max. (with 00 ma max., 0 mv max.)* Insulation resistance 00 MΩ min. (at 00 VDC) Dielectric strength 00 VAC for min (leakage current: ma max.)* Degree of protection IP (IEC) Cable retention force N/ s Insertion tolerance 00 times Operating temperature to 0 C *. The contact resistance of the Connector. *. The dielectric strength of the Connector. Compatible / /XW XWB XS G W H Connector Plug Assemblies (crimping, soldering, or screw-on) on cable ends (Sockets or Plugs) on one cable end (Plugs) Materials and Finish Item Part name Materials and finish Anchor Brass/nickel plated Contacts Brass/nickel base, 0.-μm gold plating Cable Cable Sheath color: gray Core size: AWG/AWG * Case PBT resin (ULV-0)/light gray Case Bushing Rubber PCB Glass-epoxy board Seal resin Urethane resin * The positive power supply, negative power supply, and ground lines are AWG. Signal lines are AWG.

XWB XWB Dimensions (Unit: mm) XWB-P@-@ (Four Input Ports) indicator (green LED) Operation indicator (red LED). Three,. dia.. dia. L 00 0 0. 0. dia. Internal connection indication. 0 XWB-P@-@ (Six Input Ports) indicator (green LED) Operation indicator (red LED). Three,. dia.. dia. 0. 00 L 00 0 0 / XWB-P@-@ (Eight Input Ports)... dia. dia. dia. Internal connection indication indicator (green LED) Operation indicator (red LED). 0 Three,. dia.. dia. L 00 0 0 0... dia. dia.. dia. Internal connection indication 0 / /XW XWB XS

XWB Ordering Information type and connections -wire DC /-wire DC - -wire DC-/ without polarity - -wire DC /-wire DC - Actuator connections Actuator connections - Actuator connections - No. of ports Cable length (m) Model Model Model XWB-P-G XWB-P-G XWB-P-G XWB-P-G XWB-P-G XWB-P-G XWB-P-G XWB-P-G XWB-P-G Note: Here - and - are connector pin numbers. Connection Diagrams Standard Japanese Specification XWB-P@-@ for -wire DC, -wire DC (without polarity -), and Actuator (-) -WIRE Japanese Specification European Specification XWB-P@-@ for -wire DC XWB-P@-@ for -wire DC, (with polarity -, without polarity -) -wire DC (with polarity -), and Note: Cannot be used with -type Photoelectric and Actuator (-) Proximity s. Cannot be used with Proximity s with polarity -. -WIRE -WIRE Positive power supply (Brown) indicator (Green LED) Negative power supply (Blue) Ground (Green/Yellow) Connector pin number Positive power supply (Brown) indicator (Green LED) Negative power supply (Blue) Ground (Green/Yellow) Connector pin number Positive power supply (Brown) indicator (Green LED) Negative power supply (Blue) Ground (Green/Yellow) Connector pin number / Signal (White) Lead color Signal (Green) Signal (Yellow) Operation indicator (Red LED) Signal (White) Lead color Signal (Green) Signal (Yellow) Operation indicator (Red LED) Signal (White) Lead color Signal (Green) Signal (Yellow) Operation indicator (Red LED) Signal (Gray) Signal (Pink) Signal (Red) Signal (Black) Signal (Purple) Signal (Gray) Signal (Pink) Signal (Red) Signal (Black) Signal (Purple) Note:. The above wiring diagrams are for eight-port use.. Figures in parentheses indicate lead colors.. The expression white/red means white and red stripes.. Here - and - are pin numbers. Signal (Gray) Signal (Pink) Signal (Red) Signal (Black) Signal (Purple) / /XW XWB XS

Mounting Holes XWB (Unit: mm) Three, M or. dia. ±0. ±0. Note: Mounting hole dimensions are always the same regardless of the number of ports. Safety Precautions Refer to Warranty and Limitations of Liability on page F-. Precautions for Correct Use Do not use the product in atmospheres or environments that exceed Applicable product ratings. Connector Connection or Disconnection Before using a or, check this catalog and be sure that the or can be connected. Be sure to turn OFF the power supplied to the XWB before Connector connection or disconnection. Do not touch the engaged side of any Connector with a wet hand. If a Connector is wet with water, wipe the Connector and be sure that the connector is completely dry. Be sure that there is no metal plate or powder on the engaged side of any Connector. Cable Connection Be sure to wire the cable correctly according to the wiring diagram so that the blue wire will be connected to the negative power supply terminal and the brown wire will be connected to the positive power supply terminal. If there is any wiring mistake, the load will not operate or the operation indicator will not light. Be sure to connect a load to the signal lines to operate the and Actuator. Applicable are the G (assembly type), H (monoblock type), and W (monoblock type). After a Connector is engaged, tighten the Connector securely with a mounting bracket. Be sure to put the Z- Waterproof Cover or Z- Dust Cover on any Connector that is not used. Supply and Operation Indicators When power is supplied, the green power indicator will be lit. When the s and Actuators are operating, the corresponding red operation indicators will be lit. Only DC s and Actuators can be connected to the XWB. Do not connect AC s or Actuators. es are internally wired with or wires. The type is marked on the case. -WIRE -WIRE -WIRE / / /XW XWB XS

XWB Input Device Connections Using I/O Direct Connection Type Connection Type Pre-wired Type Proximity Photoelectric W Cable with connector Proximity Photoelectric Proximity Photoelectric G Connector Assembly (solderless/soldering type) XWB XWB XWB Input Using I/O / / /XW XWB XS Connector Terminal Box XWB-P@-G XWB-P@-G XWB-P@-G Cable W-D@-@-A W-D@-@-A -wire DC Proximity -wire DC Proximity () Photoelectric () Note: Use the G Connector assembly in combination with a pre-wired input device. *. Any of these models is available provided that only its SPST-NO contact is used. *. Any of these models is available provided that it uses an NO connection. Input devices using I/O EE-XD-MJ-T, EE-XD-MJ-T, EE-X0D-MJ-T EE-X@D-M EE-XE-M, EE-XE-M, EE-X0E-M EE-XME-M, EE-X0ME-M, EE-XME-M ES-AT, ES-AT, ES-AD, ES-AD, ES-AD, ES-AD, ES-AD, ES-AD, ES-AR, ES-AR WL@-@DKEJ@ *, WL@-@-MGJ *, DC-@0@@-DKEJ@ * W-D@-@-A WL@-@K *, DE-@@0N * W-D@-@-A W-D@-@-A W-D@-@-A -wire DC Proximity () Photoelectric () -wire DC Proximity W-D@-@-A EE-XF-M, EE-XF-M, EE-X0F-M EE-XMF-M, EE-X0MF-M, EE-XMF-M ES-AT, ES-AT, ES-AD, ES-AD, ES-AD, ES-AD, ES-AD, ES-AD, ES-AR, ES-AR EE-XD-MGJ, EE-XD-MJ-T, EE-XD-MGJ, EE-XD-MJ-T, EE-X0D-MGJ, EE-X0D-MJ-T EE-XMD-MGJ, EE-XMD-MGJ, EE-X0MD-MGJ EEQ-XD-MGJ, EEQ-XD-MGJ, EEQ-X0D-MGJ EE-XD-MG, EE-XD-MG, EE-X0D-MG EE-XMD-MG, EE-XMD-MG, EE-X0MD-MG WL@-@DKEJ@ *, WL@-@-MGJ *, DC-@0@@-DKEJ@ * WL@-@K *, DE-@@0N *, DCC-@@@@ *

XWB Attaching the G Connector to Pre-wired Input Device -wire DC () : +, :, : output -wire DC (with polarity) : +, : Input devices and connector pin number -wire DC (with polarity) :, : + -wire DC (with no polarity), -wire DC () : +, :, : output XWB-P@-G Yes No Yes Yes Yes No XWB-P@-G No Yes No No No Yes XWB-P@-G No Yes No Yes Yes No es for Input with I/O Photoelectric s Proximity s es Input device Type Connection method Model -wire DC -wire DC ES-AT/, ES-AR/, and ES-AD///// ES-AT/, ES-AR/, and ES-AD///// EE-X@D-MJ-T EE-X@D-MGJ and EE-X@D-MJ-T EE-X@MD-MGJ EEQ-X@D-MGJ EE-X@D-MG EE-X@MD-MG EE-X@D-M EE-X@E-M EE-X@ME-M EE-X@F-M EE-X@MF-M WL@-@DKEJ@ *, WL@-@-MJ *, and DC-@0@@-DKEJ@ * WL@-@K * and DE-@@0N * DCC-@@@@ * *. Any of these models is available provided that only its SPST-NO contact is used. *. Any of these models is available provided that it uses an NO connection. Cable W-D@-@-A See the models above for components that are compatible with I/O. Connector Terminal Box XWB-P@-G XWB-P@-G XWB-P@-G XWB-P@-G XWB-P@-G XWB-P@-G XWB-P@-G, XWB-P@-G XWB-P@-G / / /XW XWB XS Cat. No. G0-E-0 In the interest of product improvement, specifications are subject to change without notice.