SAUTER HD Version /2015 GB

Similar documents
Instruction Manual Digital Sound Level Meter

SAUTER TVM-N Version /2016 GB

Operating instruction Platform scale

KERN FEJ Version /2005

Operating instruction Precision balances

Operating instruction Analytical and precision balances

ENGLISH ENGLISH ENGLISH ENGLISH. Installation and User Manual. version 1.00 MODWF 2014/53/UE EN :2016

Instruction Manual Digital Sound Level Meter

Operating instructions Precision/ compact balances and platform scales

Operating instructions Touch screen-industrial Balance

KTE. L Rev. 10/03/00

Návod na použitie(en) Presná váha, kontrolná váha, laboratórna váha

Operating instruction Precision/ compact balances and platform scales

Instruction Manual Mobile digital Leeb Impact Hardness Tester

Operating instructions Analytical balance


Operating Instructions

GliderThrow. Digital Angle Throw and Differential Meter. Manual

Operating Manual Compact balance

TranzPort User s Guide Version 1.0

REACH YOUR SUMIT USER GUIDE

Operating Manual Compact balance

KERN PCB Version /2015 GB

Operating Instructions For Rotating Vane Level Switch Model NIR-9 / NIR-E9

Operating Manual Precision balances

Introducing the world most advanced Shore/IRHD durometer DIGI TEST II

Shore D Hardness Tester TH210. Instruction Manual. TIME GROUP INC. Beijing Time High Technology Ltd

KERN PCB Version /2013 GB

ProLab Operating manual. ph/ise meter with automatic sensor recognition and electronic access control. DRAFT January 28, :34 pm

Incucenter ICN52/118

KERN PCB Version /2009 GB

Integrated DC RTS RECEIVER DC RTS RECEIVER

ISH-DSA DIGITAL SHORE DUROMETER OPERATION MANUAL

1. GETTING STARTED WHAT S IN THE BOX WEARING YOUR HEY BRACELET CHARGING YOUR HEY BRACELET DOWNLOADING THE HEY APP

Digital Coating Thickness Gauge Model No

Operator s Manual Product Name TEC -II Here Tissue Embedding Center Catalog # TEC2120

Manual Interface Converter K-114

ProLab Operating manual. ph/ise/conductivity measuring instrument with automatic sensor recognition and electronic access control

ProLab Operating manual. ph / ISE meter with automatic sensor recognition and electronic access control. DRAFT January 18, :18 pm

MOISTURE METER OPERATION MANUAL. all in one. Model : PMS-713

Operating instruction Moisture analyzer

FIXED RESOLUTION INCREMENTAL ENCODERS, DHM5 RANGE, 100 C. DHM5_10 connection G3R (radial cable)

ITEM ESM-BA301

1.0 Description. 2.0 Unpacking. 3.0 Installation

Operating Instructions

ProLab Operating manual. ph / ISE / conductivity / D.O. meter with automatic sensor recognition and electronic access control

HD HD [ GB ] Probes for soil volumetric water content measurement. Temperature. Humidity PART OF G H M GROUP TELEMETRIE & AUTOMATION

DS1100. LASER LIGHT DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT MAX. OUTPUT RADIATION 1mW EMITTED WAVE LENGTH nm TO EN :2001

Servicemanual KERN HCB. KERN & Sohn GmbH. Version /2014. Ziegelei 1 D Balingen

UCI ASTM-A , DIN , JB-T

C-BOX 200. Installation Manual

Mouse with Bluetooth wireless technology. SPM6950. EN User manual. Register your product and get support at

Operating Manual Electronic Moisture analyzer

Product Manual. Version 1.0

User Guide E

Hardness measurement of rubber and elastomers IRHD ISO 48 VLRH DIN ISO 27588

Operating Instructions

MFFT 10 (VF9600) MFFT 20 (VF9700)

NIM BIN NIM POWER SUPPLY TYPE

600 g x 0.02 g DIGITAL BALANCE

Manual. Expert Bypass Switch Gude Analog- und Digitalsysteme GmbH Manual Ver

Precision Instruments For Testing Rubbers & Plastics

USB to SERIAL ADAPTER

NIM / CAMAC Crates User & Service Manual

HOT WIRE ANEMOMETER. Model : 204HA

Installation and operation manual EPIC

LVB-2 INSTRUCTION SHEET. Leakage Current Verification Box

LEX 1 Ei. II 2 G EEx ia II C T6 PTB 05 ATEX 2012 X. Highly Precise, Intrinsically Safe Digital Manometer for use in Hazardous Applications.

Laser, PHOTO TACHOMETER RS

Quick Installation Guide Mercury

Instruction Manual FH EXT

User guide. Bluetooth Keyboard BKB10


Quick Installations Guide DISC1000 DISC3000 DISC4000 DISC7000

Always there to help you. Register your product and get support at DS3480. Question? Contact Philips.

40.00/400.0/4,000/40,000/400,000 Lux LIGHT METER

AC Power cord. HDMI cable (Optional)

HD 650. Bedienungsanleitung Instruction Manual Notice d emploi Istruzioni per l uso Instrucciones para el uso Gebruiksaanwijzing

AVS-Meßstative, Schlauchgarnituren und Zubehör. AVS Measurement Tripods, hose sets and accessories

Precision Measuring Instrument P650-EX/P655-EX

TU-2016 TURBIDITY METER

Level Plus. Magnetostrictive Liquid-Level Transmitters with Temposonics Technology

Instruction Manual FH EXT

FM Wireless Headphone System

DES-1016R+/DES-1024R+ 10/100 Fast Ethernet Switch

DOSTMANN electronic. Precision Measuring Instrument P600-EX/P605-EX/P650-EX/P655-EX. Operation manual

Introduction. User Manual Benutzerhandbuch Manual d utilisation Modo de uso Manuale di istruzione

Quick Start Guide for Remote Display. English Français Deutsch Nederlands Español Italiano

ECOLINE EL 515 PLUS EL 515 PLUS SET

Instruction Manual FH

BC-7000 Field Calibration Procedure 55 AMP

TKM-459 PORTABLE HARDNESS TESTER

CODUCTIVITY METER OPERATION MANUAL. Model : CD-4303

Hot wire anemometers ESV306 and ESV307. User manual

Adam Equipment. Manual. (P.N. 9009, Rev. D2, Mar 2016)

GraviTek Titration Scale Instruction Manual

OPERATION MANUAL. Pen type, air oxygen and Temp. O2 METER. Model : PO2-250

User guide. Stereo Bluetooth Headset SBH60

Instruction Manual FH

Instruction Manual FH

Transcription:

Sauter GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@sauter.eu Tel: +49-[0]7433-9933-199 Fax: +49-[0]7433-9933-149 Internet: www.sauter.eu Instruction Manual Digital Shore Hardness Tester SAUTER HD Version 2.2 02/2015 GB HD-BA-e-1522

GB SAUTER HD Version 2.2 02/2015 Instruction Manual Digital Shore Hardness Tester Thank you for buying a digital SAUTER Shore hardness tester. We hope you are pleased with your high quality instrument and with its big functional range. If you have any queries, wishes or helpful suggestions, do not hesitate to call our service number. Summary: 1 Features... 3 2 Specifications... 3 3 Front Panel Descriptions... 4 4 Measuring Procedure... 4 5 Calibration Check... 5 5.1 Zero calibration... 6 5.2 High end calibration... 6 6 Battery replacement... 6 7 Note... 6 8 Declaration of Conformity... 7 2 HD-BA-e-1522

This Shore Hardness Tester is small in size, light in weight, easy to carry, it is convenient to use and operate. It`s ruggedness will allow many years of use if proper operating techniques are followed. Please read the following instructions carefully and always keep this manual within easy reach. 1 Features * Designed to determine the indentation hardness of materials ranging from cellular products to rigid plastics. Each durometer type is made to a specific scale (e.g. A, D, O) and is capable of producing a value between 0 and 100. * Shore A is designed for soft vulcanized rubber, natural, thermoplastic elastomers, flexible polyacrylics and thermosets, wax, felt, and leathers. * Shore D is designed for hard Rubber, thermoplastic elastomers, harder plastics and rigid thermoplastics moderately hard * Shore O is designed for soft rubber, thermoplastic elastomers, very soft plastics and thermoplastics, medium-density textile windings. * Uses the exclusive Micro-computer LSI circuit and crystal time base to offer high accuracy measurement. * Digital display gives exact reading with no guessing or errors. * Can communicate with PC for recording, printing and analyzing by the optional software and cable for RS232C interface. * Automatic power off to conserve power. * A test stand as optional part can get better accuracy and repetitiveness due to a constant measurement force to eliminate the errors caused by artificially applied different forces. 2 Specifications Display: LCD Display Housing: High impact ABS Resolution: 0.1 Range: 0~100H Accuracy: ±1% Measurement speed: >30 (readings per minute) Operating temperature: 0 C~50 C Power: 2x1.5v AAA (UM-4) battery Size: 176x63x25mm Weight: 310 g Standard Accessories: * Main unit * Test block * Carrying case * Operation manual Optional Accessories: * RS-232 data output HD-BA-e-1522 3

3 Front Panel Descriptions 3-1 Display 3-2 Number of measurements in the state of Average Value 3-3 Indicator of Average Value 3-4 RS 232 Interface 3-5 max. HOLD key 3-6 CAL key 3-7 Battery Cover 3-8 Wrist Ring 3-9 State of Average Value 3-10 Power key 3-11 N/ Average key 3-12 Zero key 3-13 Sensor (Indenter) 4 Measuring Procedure 4.1 The Specimen should allow measurement to be taken at least 12 mm from any edge. Specimen surface should be flat and parallel to allow the presser face to contact to the specimen over an area which has a minimum radius of 6mm from the durometer probe. The specimen may be constructed with layered pieces to achieve the necessary thickness requirements, however measurements taken on these specimens may not agree with those made on solid specimens, due to the surface faces between layers not being in complete contact. 4 HD-BA-e-1522

4.2 Press and release the Power key to power the tester on. 4.3 Press the MAX key until the mark MAX is shown on the display. 4.4 Hold the durometer vertically with the point of the indenter at least 12 mm from any edge. Apply the presser foot to the specimen as rapidly as possible, without shock, keeping the foot parallel to the surface of the specimen. Apply just sufficient force to obtain firm contact between the presser foot and the specimen. Hold for 1 or 2 seconds, the maximum reading can be obtained automatically. 4.5 To take the next measurement, just press the Zero key and repeat 4.4. On the other hand, you can press the till the mark MAX disappears from the display. And then repeat the step 4.3 and 4.4. 4.6 If other than a maximum reading is needed, no need to set the mark MAX showing on the display. In such case, the reading on the display is an instant value. Just hold the durometer in place without motion and obtain the reading after the required time interval (Normally less than 1 second). 4.7 How to take average value 4.7.1 To take the average value of many times of measurements, just press and release the N/AVE key to make the symbol N to be shown on the display, followed by a digit between 1-9 with the prefix No. Here the digit is the times of measurements used to calculate the average value. Every time you press and release the N/AVE key, the digit will increase 1. And the digit will become 1 again while pressing the N/AVE key at 9. 4.7.2 Adjust the digit to the number needed and press MAX key or Zero key to return to the measurement state or wait for several seconds till 0 appears on the display. 4.7.3 Take measurements as per steps from 4.3 to 4.5. Be sure that every test should be 6 mm apart. Every time a measurement is performed, the reading and the times of measurements are shown on the display. When the times of measurements are equal to the number set, the unit first displays the reading of the last, and then displays the average value of last N measurements, followed by 2 beeps, with a symbol AVE indicated on the display. 4.7.4 To take the next average value, just repeat 4.7.3. 4.7.5 To release from average measurement, just press the N/AVE till N disappears. 5 Calibration Check To check whether the tester is accurate, just insert the indenter into the hole of the calibrated test block. Apply enough force to make firm contact between the top surface of the test block and the presser foot. The reading should agree with the value stamped on the test block. If not, just carry out Zero calibration and High end calibration. HD-BA-e-1522 5

5.1 Zero calibration Hold the durometer vertically with the point of the indenter hanging in the air, the reading on the display should be 0. If not, press the Zero key to make the tester display 0. 5.2 High end calibration Just place the indenter onto a flat glass, apply enough force to make firm contact between the glass and the presser foot. The readings on the display should be between 99.5 and 101. If not, press CAL key to carry out high end calibration. 6 Battery replacement a) When the battery symbol appears on the display, it is time to replace the batteries. b) Slide the battery cover away from the tester and remove batteries. c) Install batteries, paying careful attention to polarity. 7 Note Readings below 10HD for Shore D type may be inexact and should not be reported for some materials. Measurements should be made on a Shore A type. Readings above 90HA for Shore A should be made on a Shore D type durometer. 6 HD-BA-e-1522

8 Declaration of Conformity Sauter GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@sauter.eu Ziegelei 1 D-72336 Balingen E-Mail: info@sauter.eu Konformitätserklärung Declaration of conformity for apparatus with CE mark Konformitätserklärung für Geräte mit CE-Zeichen Déclaration de conformité pour appareils portant la marque CE Declaración de conformidad para aparatos con marca CE Dichiarazione di conformità per apparecchi contrassegnati con la marcatura CE D GB E F I Konformitätserklärung Declaration of conformity Declaración de conformidad Déclaration de conformité Dichiarazione di conformità Wir erklären hiermit, dass das Produkt, auf das sich diese Erklärung bezieht, mit den nachstehenden Normen übereinstimmt. We hereby declare that the product to which this declaration refers conforms with the following standards. Manifestamos en la presente que el producto al que se refiere esta declaración está de acuerdo con las normas siguientes Nous déclarons avec cela responsabilité que le produit, auquel se rapporte la présente déclaration, est conforme aux normes citées ci-après. Dichiariamo con ciò che il prodotto al quale la presente dichiarazione si riferisce è conforme alle norme di seguito citate. Digital Shore Hardness Tester: HD EU Directive EMC directive 2004/108/EC Standards EN 55011:2009+A1:2010 EN 61000-3-2:2006+ A1:2009+ A2:2009 EN 61000-3-3:2008 EN 61000-6-2:2005 Datum Date Ort der Ausstellung Place of issue 07.04.2014 Signatur Signature 72336 Balingen Albert Sauter SAUTER GmbH Geschäftsführer Managing director SAUTER GmbH, Ziegelei 1, D-72336 Balingen, Tel. +49-[0]7433/9933-199 Fax +49-[0]7433/9933-149, E-Mail: info@sauter.eu, Internet: www.sauter.eu HD-BA-e-1522 7