U-Match Series DC Inverter Service Manual PRODUCT

Similar documents
DUCTED SPLIT SYSTEMS With Scroll compressors

SINGLE. Technical Data Book. 4Way Cassette S for (Inv, R410A,

Slim duct (AMTTTFNLDEH ) Indoor units

SINGLE. Technical Data Book. Big Duct for EU (R410A, 50Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU

AIR COOLED CONDENSERS

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity

VRF. Technical Data Book. Slim duct for America (R410A, 60Hz, HP) Model : AM***FNLDCH***

HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT

DESIGN & TECHNICAL MANUAL

Product Data. S Up to 19 SEER / up to 12.5 EER S Microtube Technologyt refrigeration system Sound

MULTI SPLIT 074 PRODUCT LINEUP & 3-4 ROOMS MULTI ROOMS MULTI 080 INDOOR UNITS FOR MULTI SPLIT SPECIFICATIONS 082 MULTI COMBINATION

VRF Technical Data Book

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24,

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

Product Data. S Up to 19 SEER /13.0 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound

Product Data. S Up to 18 SEER /12.5 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound

STANDARD MODELS MT 3/4 HP + LT 2.5 HP MT 1.0 HP + LT 2.5 HP. Other models available upon request

HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED HEAT PUMP WITH OBSERVER

CTXA-AS/AT/AW, FTXA-AS/AT/AW

R410A D2D_AU019E/

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw

VRF. Technical Data Book. DVM S Eco 8, 9 HP

SINGLE. Technical Data Book. Multi-position AHU for North America (Low Ambient, R410A, 60Hz, H/P)

SINGLE. Technical Data Book. Multi-position AHU for North America (Low Ambient, R410A, 60Hz, H/P)

SINGLE Technical Data Book. SINGLE for Europe (R410A, HP)

Product Data. S Up to 19 SEER /13 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD

User's manual. GREE AHU kit. Type: U-Match Version: 1.02

Slim Ducted type. Contents MMD-AP 4SPH2UL MMD-AP0094SPH2UL MMD-AP0124SPH2UL MMD-AP0154SPH2UL MMD-AP0184SPH2UL

Product Submittal. Project Information Project Name: Ulta 1307 Seneca SC. Customer Information Company Name: Engineering Information Company Name:

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXB-C

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

KLP. Low Profile Evaporators CONTENTS PRODUCT DATA & INSTALLATION

Product Data. 24ANA1 Infinityt 21 Series Air Conditioner with PuronR Refrigerant 2Through5NominalTons(Size24To60) INDUSTRY LEADING FEATURES / BENEFITS

FPS SERIES Super Slim Ceiling Mount Air Handling Units

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

Ceiling Concealed Split System C Series

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 05 Jl. Malibu Raya, Cengkareng Jakarta Barat Indonesia. Phone

DCC Commercial. Submittal Data Form Tons Packaged Air Conditioners

AIR COOLED HEAT PUMPS WITH SCREW COMPRESSORS AND AXIAL FANS

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

SmoothAir Modular Precision Cooling

Filter Fan Unit LIGHT

DCG Commercial. Submittal Data Form

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full perimeter rail Sloped drain pan

1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES

Split System Cooling Product & Performance Data

Air Conditioning Technical Data FBA-A > FBA35A2VEB > FBA50A2VEB > FBA60A2VEB > FBA71A2VEB > FBA100A2VEB > FBA125A2VEB > FBA140A2VEB

CHAPTER 1. Unit CHA/IK/WP CHA/CLK CHA/ML/ST CHA/ML/ST CHA/ML/ST 182-P 302-P 50-51

Motivair MLC-SC Air-Cooled Scroll Chillers Tons

7. PCB AND FUNCTIONS

14ACX. MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,700 to 58,000 Btuh. 14 AC x MODEL NUMBER IDENTIFICATION

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

ZTE ZXCR Series DX In-Row Air Conditioning Product Description

NEOSTAR AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE HFC. 18 > 1240 kw. NEOSTAR POWER The choice of performance and low space requirement.

Reliability and extended operation

InPac 600 Series Fully configurable severe duty and explosion proof HVAC and building pressurization systems 2 5 ton ::

Air Conditioning Technical Data FVA-A > FVA71AMVEB > FVA100AMVEB > FVA125AMVEB > FVA140AMVEB

Precision Cooling. Precision Cooling Advantages

AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS

IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.

Split System Cooling Product & Performance Data

Product Data. 25HNA9 Infinityt 19 Series Heat Pump with Puronr Refrigerant 2 To 5 Tons Nominal (Size 24 To 60) INDUSTRY LEADING FEATURES / BENEFITS

14ACX. MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,700 to 58,000 Btuh. 14 AC x MODEL NUMBER IDENTIFICATION

MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers

IT Air Conditioning Units

Kirby NK Heavy Commercial Industrial Unit Cooler. Natural fluids: Glycol water

SERVICE Manual DUCT TYPE AIR CONDITIONER. (Cool) OUTDOOR UNIT INDOOR UNIT TYPE UDH4400G DH44ZAX IDH4400A DH44ZA1(A2) ADH4400G DH44ZA1(A2)

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

CPH Series. Submittal Data Form. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. with R-410A

MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers

Semi-hermetic Air-cooled Condensing Units

Product Data PH16NA FEATURES / BENEFITS. 16 SEER 2---Stage Split---System Heat Pump With R---410A Refrigerant 2 To 5 Tons ( ) AVAILABLE SIZES:

42C/V. Fan Coil Unit Air Flow: 340~2040m 3 /h

Technical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC

DTH Series. Submittal Data Form. 3-5 Tons Heat Pumps 15 SEER Up to 13.0 EER / 8.2 HSPF

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

AIR Compressor. Efficient Cooling System. PCG Series 01/02

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons

1.5 to 5 Tons INDOOR COILS CX35. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES

Air Conditioning Technical Data FHA-A > FHA35AVEB > FHA50AVEB > FHA60AVEB > FHA71AVEB > FHA100AVEB > FHA125AVEB > FHA140AVEB

HV-STYLVENT Series WALL OR WINDOW EXTRACT FANS. Wall or window extract fans HV-STYLVENT. Elegant design harmonising with any environment

McQuay. Commercial Unitary Rooftop Cooling Only or with Electric Heat. LCA Design 1. Last Manufactured: 2004

Product Data. S SEER/ EER/ HSPF S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound

kyalfa V- VDD/VDD6 General Contents

MAKING MODERN LIVING POSSIBLE. ADAP-KOOL Drive. A New Drive for Energy Efficiency AKD 102 REFRIGERATION & AIR CONDITIONING DIVISION

COMMERCIAL AIR CONDITIONERS Flooded Type Water Cooled Screw Chiller 2012

Product Data. 25HNA6 Infinityt 16 Series Heat Pump with Puronr Refrigerant Sizes 24 to 60 2To5NominalTons INDUSTRY LEADING FEATURES / BENEFITS

EQUIPMENT ENGINEERING & SPACE PLANNING DATA SYSTEM LEVEL

Ecoflair Air Economizers

Aquaflair. BREC & BREF kW 380V/3ph/60Hz - 460V/3ph/60Hz. Air-cooled chillers and free-cooling chillers with double screw compressors

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

Technical Concept. Filter Fan Unit RETURN AIR. Type RA-AC Type RA-EC

Split. Air Conditioning Technical Data FTXM-M > FTXM20M2V1B > FTXM25M2V1B > FTXM35M2V1B > FTXM42M2V1B > FTXM50M2V1B > FTXM60M2V1B

1.5 to 5 Tons INDOOR COILS C35. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F - 1 MODEL NUMBER IDENTIFICATION FEATURES

Transcription:

PRODUCT 1

PRODUCT 1 MODELS LIST 1.1 Outdoor Unit Name Product Code Power Supply (V, Ph, Hz) Appearance GUHD24NS3GO CF090W0800 220-240V~ 50/60Hz GUHD36NS3GO CF090W0860 220-240V~ 50/60Hz GUHD42NS3GO CF090W0870 220-240V~ 50/60Hz GUHD48NS3GO CF090W0880 220-240V~ 50/60Hz GUHD60NS3GO CF090W0790 220-240V~ 50/60Hz 2

1.2 Indoor Unit Type Name Product Code Nominal Capacity Cooling/Heating (kw) Power Supply (V, Ph, Hz) Appearance GFH24S3GI CF060N0560 7.0/8.0 GFH24S3G1I CF060N0630 7.0/8.0 220-240V~ 50/60Hz GFH36S3GI CF060N0650 10.0/12.0 GFH36S3G1I CF060N0660 10.0/12.0 220-240V~ 50/60Hz Duct Type GFH42S3GI CF060N0670 12.0/13.8 GFH42S3G1I CF060N0680 12.0/13.8 220-240V~ 50/60Hz GFH48S3GI CF060N0690 13.7/16.0 GFH48S3G1I CF060N0700 13.7/16.0 220-240V~ 50/60Hz GFH60S3GI CF060N0550 16.0/18.0 GFH60S3G1I CF060N0640 16.0/18.0 220-240V~ 50/60Hz 3

2 NOMENCLATURE 2.1 Outdoor Unit G U H D 24 N S 3 G O 1 2 3 4 5 6 7 8 9 10 NO. Description Options 1 Gree Electric Appliances Inc Capital Letter :G 2 Unit Type U=U-Match Outdoor Unit 3 Product Type 4 Compressor Power Supply Type Code 5 Nominal Cooling Capacity 6 Climate Type C=Cool Only H=Heat Pump without Aux Electric Heaters N=Constant Frequency D=DC Inverter A=AC Inverter Nominal Cooling Capacity =Number 1000Btu/h N=Climate T1 Condition T= Climate T3 Condition 7 Power Supply Code S= 220-240V~ 50/60Hz 8 Refrigerant 1 =R22; 2=R407C; 3=R410A 9 Design Code 10 Unit Code O=Outdoor unit 2.2 Intdoor Unit Design Code: A, B, C, D Design Change Code=0 (default) 1,2,3... G F H 24 T S 3 G I 1 2 3 4 5 6 7 8 9 NO. Description Options 1 Gree Electric Appliances Inc Capital Letter :G 2 Unit Type F=Duct Type; K=Cassette Type; T= Floor-ceiling Type 3 Product Type 4 Nominal Cooling Capacity 5 Climate Type C=Cool Only H=Heat Pump without Aux Electric Heaters Nominal Cooling Capacity =Number 1000Btu/h Omit=Climate T1 Condition T= Climate T3 Condition 6 Power Supply Code S= 220-240V~ 50/60Hz 7 Refrigerant 1 =R22; 2=R407C; 3=R410A 8 Design Code Design Code: A, B, C, D Design Change Code=0 (default) 1,2,3... 9 Unit Code I=indoor unite 4

3 PRODUCT DATA 3.1 Product Data of Indoor Unit 3.1.1 Duct Type Nominal Capacity Piping Power Input Cooling Heating Indoor unit GFH24S3GI GFH24S3G1I Outdoor unit GUHD24NS3GO GUHD24NS3GO kw 7.00 7.00 Btu/h 23884 23884 kw 8.00 8.00 Btu/h 27296 27296 Cooling kw 2.18 2.18 Heating kw 2.28 2.28 EER/COP W/W 3.21/3.51 3.21/3.51 Indoor Unit GFH24S3GI GFH24S3G1I Power Supply 220-240V~ 50/60Hz Heat Exchange Cross Fin Coil Cross Fin Coil Type Centrifugal Centrifugal Drive Direc t Direc t Motor Output kw Air Flow m 3 /h 1500 1500 Rated Ext. Static Pa 50 50 Pressure Sound Pressure Level(SS/H/M/L) db(a) 46/43/41/38 46/43/41/38 Compressor Refrigerant Air Filter PPKZ Drain Piping Φ20 1.2 Φ20 1.2 1225 290 775 1225 290 775 1338 305 877 1338 305 877 Weight(Net/Gross) kg 47.0/55.0 47.0/55.0 Outdoor Unit GUHD24NS3GO GUHD24NS3GO Power Supply 220-240V~ 50/60Hz Heat Exchange Cross Fin Coil Connections Type Axial-flow Motor Speed rpm 800 800 Type Inverter Rotary Inverter Rotary Power Input W 2550 2550 Type R410A Control Electronic Expansion Valve Charge kg 2.2 2.2 1005 790 425 1005 790 425 1083 855 488 1083 855 488 Weight(Net/Gross) kg 69.0/74.0 69.0/74.0 Liquid Inch 3/8 3/8 Gas Inch 5/8 5/8 Max. Length m 50 50 Max. Height m 15 15 5

Nominal Capacity Power Input Indoor unit GFH36S3GI GFH36S3G1I GFH42S3GI Outdoor unit GUHD36NS3GO GUHD36NS3GO GUHD42NS3GO Cooling Heating kw 10.00 10.00 12.00 Btu/h 34120 34120 40944 kw 12.00 12.00 13.80 Btu/h 40944 40944 47086 Cooling kw 3.10 3.10 3.70 Heating kw 3.30 3.30 4.00 EER/COP W/W 3.23/3.64 3.23/3.64 3.24/3.45 Indoor Unit GFH36S3GI GFH36S3G1I GFH42S3GI Power Supply 220-240V~ 50/60Hz Heat Exchange Cross Fin Coil Cross Fin Coil Cross Fin Coil Type Centrifugal fan Centrifugal fan Centrifugal fan Drive direct direct direct Motor Output kw Air Flow m 3 /h 2000 2000 2200 Rated Ext. Static Pressure Pa 50 50 50 Sound Pressure Level(SS/H/M/L) db(a) 48/45/43/41 48/45/43/41 50/48/46/43 Compressor Refrigerant Air Filter PPKZ PPKZ PPKZ Drain Piping Φ20 1.2 Φ20 1.2 Φ20 1.2 1340 350 750 1340 350 750 1340 350 750 1423 455 837 1423 455 837 1423 455 837 Weight(Net/Gross) kg 56/68 56/68 59/71 Outdoor Unit GUHD36NS3GO GUHD36NS3GO GUHD42NS3GO Power Supply 220-240V~ 50/60Hz Heat Exchange Cross Fin Coil Type Axial fan Motor Speed rpm 780 780 780 Type Inverter Rotary Inverter Rotary Inverter Rotary Power Input W 4150 4150 4580 Type R410A Control Electronic Expansion Valve Charge kg 3.5 3.5 3.9 1105 1100 440 1105 1100 440 1105 1100 440 1158 1235 493 1158 1235 493 1158 1235 493 Weight(Net/Gross) kg 91/100 91/100 101/111 Liquid Inch 3/8 3/8 3/8 Piping Connections Gas Inch 5/8 5/8 5/8 Max. Length m 50 50 50 Max. Height m 15 15 30 6

Nominal Capacity Power Input Indoor unit GFH42S3G1I GFH48S3GI GFH48S3G1I Outdoor unit GUHD42NS3GO GUHD48NS3GO GUHD48NS3GO Cooling Heating kw 12.0 13.7 13.7 Btu/h 40944 46744 46744 kw 13.8 16.0 16.0 Btu/h 47086 54592 54592 Cooling kw 3.70 4.25 4.25 Heating kw 4.00 4.80 4.80 EER/COP W/W 3.24/3.45 3.22/3.33 3.22/3.33 Indoor Unit GFH42S3G1I GFH48S3GI GFH48S3G1I Power Supply 220-240V,~50/60Hz Heat Exchange Cross Fin Coil Type Centrifugal fan Drive direct Motor Output kw Air Flow m 3 /h 2200 2500 2500 Rated Ext. Static Pressure Pa 50 50 50 Sound Pressure Level(SS/H/M/L) db(a) 50/48/46/43 51/48/46/44 51/48/46/44 Air Filter PPKZ Drain Piping Φ20 1.2 Φ20 1.2 Φ20 1.2 1340 350 750 1340 350 750 1340 350 750 1423 455 837 1423 455 837 1423 455 837 Weight(Net/Gross) kg 59/71 59/71 59/71 Outdoor Unit GUHD42NS3GO GUHD48NS3GO GUHD48NS3GO Power Supply 220-240V~50/60Hz 220-240V~ 50/60Hz 220-240V~50/60Hz Heat Exchange Cross Fin Coil Cross Fin Coil Cross Fin Coil Compressor Type Axial fan Axial fan Axial fan Motor Speed rpm 780 800 800 Type Inverter Rotary Inverter Rotary Inverter Rotary Power Input W 4580 4580 4580 Type R410A R410A R410A Refrigerant Control Electronic Expansion Valve Charge kg 3.9 4.0 4.0 1105 1100 440 1085 1365 425 1085 1365 425 1158 1235 493 1143 1505 478 1143 1505 478 Weight(Net/Gross) kg 101/111 117/128 117/128 Liquid Inch 3/8 3/8 3/8 Piping Connections Gas Inch 5/8 5/8 5/8 Max. Length m 50 50 50 Max. Height m 30 30 30 7

Nominal Capacity Power Input Indoor unit GFH60S3GI GFH60S3G1I Outdoor unit GUHD60NS3GO GUHD60NS3GO Cooling Heating kw 16.0 16.0 Btu/h 54592 54592 kw 18.0 18.0 Btu/h 61416 61416 Cooling kw 5.00 5.00 Heating kw 5.00 5.00 EER/COP W/W 3.20/3.60 3.20/3.60 Indoor Unit GFH60S3GI GFH60S3G1I Power Supply 220V-240V 50/60Hz Heat Exchange Cross Fin Coil Type Centrifugal Drive direct Motor Output kw - Air Flow m 3 /h 3100 3100 Rated Ext. Static Pressure Pa 50 50 Sound Pressure Level(SS/H/M/L) db(a) 55/53/51/48 55/53/51/48 Compressor Refrigerant Piping Connections Air Filter PPKZ Drain Piping φ 30 1.5 φ 30 1.5 1497 389 799 1497 389 799 1578 470 883 1578 470 883 Weight(Net/Gross) kg 79.0/103.0 79.0/103.0 Outdoor Unit GUHD60NS3GO GUHD60NS3GO Power Supply 220-240V~ 50/60Hz Heat Exchange Cross Fin Coil Type Axial-flow Motor Speed rpm 800 800 Type Inverter Rotary Power Input W 4580 4580 Type R410A Control Electronic expansion valve Charge kg 5.5 5.5 1085 1365 425 1085 1365 425 1143 1505 478 1143 1505 478 Weight(Net/Gross) kg 121.0/133.0 121.0/133.0 Liquid Inch 3/8 3/8 Gas Inch 3/4 3/4 Max. Length m 50 50 Max. Height m 30 30 Note: Nominal capacities are based on the follow conditions. Mode Indoor ( ) Outdoor ( ) Cooling Heating DB:27(80.6) WB:19(66.2) DB:20(68.0) WB:--(--) DB:35(95.0) WB:24(75.2) DB:7(44.6) WB:6(42.8) Piping Length 24K-60K 7.5m 8

The air volume is measured at the relevant standard external static pressure. Noise is tested in the Semianechoic room, so it should be slightly higher in the actual operation due to environmental change. 3.2 Operation Range Mode Range of Outdoor Temperature Cooling -15-48 Heating -10-24 3.3 Electrical Data 3.3.1 Outdoor unit Table 1-4-1 Electrical Data of Outdoor Unit Compressor Motor Power Supply Qty. RLA FLA Fuse/Breaker Capacity Min. Power Supply Cord V/Ph/Hz A A A 2 GUHD24NS3GO 220-240,1,50/60 1 11.5-20 2.5 GUHD36NS3GO 220-240,1,50/60 1 19.0-20 4.0 GUHD42NS3GO 220-240,1,50/60 1 21.0-25 4.0 GUHD48NS3GO 220-240,1,50/60 1 21.0-40 6.0 GUHD60NS3GO 220-240,1,50/60 1 21.0-40 6.0 3.3.2 Indoor unit Table 1-4-2 Electrical Data of Indoor Unit Power Supply Motor FLA Fuse/Breaker Capacity Min. Power Supply Cord V/Ph/Hz A A 2 GFH24S3GI 220,1,50 <1 5/6 1.0 GFH24S3G1I 220,1,50 <1 5/6 1.0 GFH36S3GI 220,1,50 <1 5/6 1.0 GFH36S3G1I 220,1,50 <1 5/6 1.0 GFH42S3GI 220,1,50 <1 5/6 1.0 GFH42S3G1I 220,1,50 <1 5/6 1.0 GFH48S3GI 220,1,50 <1 5/6 1.0 GFH48S3G1I 220,1,50 <1 5/6 1.0 GFH60S3GI 220,1,50 <1 5/6 1.0 GFH60S3G1I 220,1,50 <1 5/6 1.0 9

Notes: RLA:Rated load amperes LRA:Locked rotor amperes FLA:Full load current 1 Install the disconnect device with a contact gap of at least 3 in all poles nearby the units (Both indoor unit and outdoor unit).the appliance must be positioned so that the plug is accessible. 2 The specifications of the breaker and power cable listed in the table above are determined based on the maximum power (maximum amps) of the unit. 3 The specifications of the power cable listed in the table above are applied to the conduit-guarded multi-wire copper cable (like, YJV copper cable, consisting of PE insulated wires and a PVC cable jacket) used at 40 С and resistible to 90 С. If the working condition changes, they should be modified according to the related national standard. 4 The specifications of the breaker listed in the table above are applied to the breaker with the working temperature at 40 С. If the working condition changes, they should be modified according to the related national standard. 4 PIPING DIAGRAM 10