BNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide

Similar documents
BNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide

BNI IOL K006 BNI IOL-106-S01-K006 BNI IOL-106-S01-K006-C01. User s Guide

BNI IOL K006. IO Link Sensorhub digital User s Guide

BNI IOL-104-S01-Z012-C02

BNI IOL Z012. User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide

BNI IOL Z036 BNI IOL Z036

BNI IOL Z012 BNI IOL-302-S01-Z012 BNI IOL Z042

BNI IOL Z019. IO-Link 1.1 sensor hub With extension port User s Guide

BNI IOL K023 BNI IOL K023. User s Guide

BNI IOL Z046. IO-Link 1.1 sensor/actuator hub with extension port User's Guide

BNI IOL E012. IO-Link 1.1 sensor/actuator hub with extension port User's Guide

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide

BNI IOL Z046. IO-Link 1.1 Sensor hub with extension port User's Guide

BNI IOL-75x-Vxx-K007 Valve Plug Short Guide

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide

BNI IOL A027 BNI IOL A027

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 Short Guide

BNI IOL K023 BNI IOL K023. User s Guide

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001. Quick start guide

BNI PBS Z001. IP67 module, Profibus IO-Link Master Short Guide

BNI IOL K023 BNI IOL K023. User s Guide

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide

BNI PNT Z015. IP67 Modules 16 Input User s Guide

BNI PNT Z015. IP67 Modules 4 IO-Link/In-/Outputs,12 In-/Outputs User s Guide

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

BNI DNT Z004 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005 Short Guide

BNI EIP Z016. IP67 Modules, 8 Outputs BNI EIP Z016 BNI EIP Z016 IP67 Modules, 16 Outputs User s Guide

BNI USB A501. USB IO-Link Master User's Guide. english

BNI IOL Z036 BNI IOL Z BNI IOL Z037 BNI IOL Z Smart Light User s Guide

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide

BNI EIP Z016 IP67 Modules, 16 In-/Outputs User s Guide

BNI IOL Z012. User s Guide

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

BNI USB A501. User s Guide

BIS L x-07-S4

BNI DNT Z001 DeviceNet IO-Link Master User s Guide

BIC 1B0-ITA50-Q40KFU-SM4A4A BIC 1B0-IT005-Q40KFU-SM4A4A BIC 2B0-ITA50-Q40KFU-SM4A5A. User s Guide

BNI DNT Z001. DeviceNet IO-Link Master User s Guide

BNI PNT Z015 BNI PNT Z015. IP67 Module User s Guide

BNI DNT Z001. DeviceNet IO-Link Master User s Guide

BNI EIP E002. EtherNet/IP IP69 modules User's Guide

BNI EIP Z015-C06. IP67 Modules 8 IO-Link/In-/Outputs, 8 In-/Outputs User s Guide

Balluff Network Interface / CC-Link BNI-CCL Z001 BNI CCL Z001. Extended User Manual. 1

BNI EIP Z015 IP67 Modules 16 Inputs User s Guide

BNI CCL Z001. CC-Link IO-Link Master User s Guide

BNI EIP Z015. IP67 Modules 8 IO-Link/In-/Outputs, 8 In-/Outputs User s Guide

BNI EIP Z040. IP67 Module 4 IO-Link Class A and 8 in- and outputs 4 IO-Link Class B and 4 inputs User's Guide

BNI PNT Z015 BNI006C. IP67 Module User s Guide

BNI DNT Z004 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005. User s Guide

BIS L x-07-S4

BNI CIE Z015 BNI CIE Z015 BNI CIE Z015 BNI CIE Z015. CC-Link IE Field Standard I/O Modules User's Guide

BNI PNT Z031 BNI PNT Z IP67 Module User s Guide

BNI PNT Z015 BNI PNT Z015. IP67 Module User s Guide

BNI EIP R015 BNI EIP R015. EtherNet/IP IP67 modules User's Guide

BNI EIP Z015 BNI EIP Z015. EtherNet/IP IP67 modules User's Guide

BNI CIE Z015 BNI CIE Z015. CC-Link IE Field IO-Link Master User's Guide

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001. Profibus IO Modules User's Guide

BNI CCL Z001. CC-Link IO-Link Master User s Guide

Profibus I/O Modules BNI PBS Z001 BNI PBS Z001

GFK-2415A March Type of sensor connection

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

BIS M _ 0 _ -07-S4 BIS M _ 0 _ -07-S4

BIS M xx-ST4 PROFINET

BIS M _ -07-S4 BIS M _ -07-S4

BTL6-V1 _ E-M -A1-S115 User's Guide

SCHMIDT Sensor interface PROFIBUS Instructions for use

BIS M x-ST4 EtherNet/IP

BTL6-V11V-M -A1-S115 User's Guide

VersaMax IP I/O Module

BIS L , BIS Z-EL-...

BIS V-6102 PROFIBUS. Technical Description, User s Guide. english 42,7 61,9 5,3 168,3 +6,0 157,6 +6,0 36,4 2,5 48,2

BIS V-6102 Profibus. Technical Description, User's Guide. English 42,7 61,9 5,3 168,3 +6,0 157,6 +6,0 36,4 2,5 48,2

Pressure Transmitters with IO-Link BSP-Bxxx-xx004-xxxS1A-xx, BSP-Vxxx-xx004-xxxS1A-xx

BTL6-A_10-M -A1-S115. Data Sheet. english

AXL E IOL AO1 U M12 R

Manual LioN-P - IO-Link Device - I/O Hub

User's Manual. english

BNI EIP Z015 BNI EIP Z015 BNI EIP Z015. EtherNet/IP IP67 Modules User s Guide

2-Axis Counter BDD 622

BNI EIP Z015-C06. EtherNet/IP IP67 modules User's Guide

VersaMax IP Input Module

Balluff smart safety BE ON THE SAFE SIDE. SAFETY OVER IO-LINK

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

BTL5-A/C/E1_-M- -SF-F User's Guide

Manual Electronic Identification Systems BIS Processor BIS C-6_1 C6_1-023_9912-e.p65 Deutsch bitte wenden!

Single-Axis Counter BDD 611

SK TU4-IOE-M12-C Part Number

BIS V-6108 PROFINET. Technical Description, User s Guide. english

BNI PNT Z063. IP67 Module User's Guide

BIS S-6027 Ethernet with TCP/IP-Protocol

Operating instructions Memory plug E /02 11/2011

BVS SC-_1280Z _0 SMARTCAMERA Fieldbus

BIS V-6102 PROFIBUS Technical Reference, Operating Manual

Manual ICA-16DI-G60A-IO, ICA-10DI6DO-G60A-IO. I/O Hub with IO-Link

Manual Electronic Identification Systems BIS Processor BIS C-6_0 RS 232 C-6_ _836905_E_0704.p65 Deutsch bitte wenden!

Operating instructions AC010S Compact AS-i E-STOP safety module

BNI PNT Z015 BNI PNT Z015. IP67 Module User s Guide

Transcription:

BNI IOL302000K006 BNI IOL302000K006C01 BNI IOL302S01K006 BNI IOL302S01K006C01 IOLink 1.1 SensorHub / ActuatorHub User s Guide

Content 1 Notes to the user 2 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 Enumerations 2 Actions 2 Syntax 2 Crossreferences 2 1.4 Symbols 2 1.5 Abbreviations 2 2 Safety 3 2.1 Intended use 3 2.2 General safety notes 3 2.3 Meaning of the warnings 3 3 Getting Started 4 3.1 Connection overview 4 3.2 Mechanical connection 5 3.3 Electrical connection 5 3.4 Function ground 5 3.5 IOLink connection 5 Sensor Hub connection 6 Module versions 6 3.6 Digital Sensors 6 4 IOLink Interface 7 4.1 IOLink Data 7 4.2 Process data inputs 7 4.3 Processdata / Output data 11 4.4 Parameter data/ Onrequest data 11 Inversion 13 Port Direction 13 Fault State Pin 4 13 Fault State Pin 2 14 Voltage Monitoring 15 Actuator short 15 Actuator warning 15 Us>Ua 15 Identification 15 4.5 Errors 16 4.6 Events 16 5 Technical Data 17 5.1 Dimensions 17 5.2 Mechanical data 17 5.3 Electrical data 17 5.4 Operating conditions 17 5.5 Function indicators 18 Module LEDs 18 Digital Input LEDs 18 6 Appendix 19 6.1 Type designation code 19 6.2 Order information 19 www.balluff.com 1

IOLink SensorHub / Actuator Hub 1 Notes to the user 1.1 About this guide This guide describes the Balluff IOLink sensor collector module, also called the Sensor Hub / Actor Hub. Connection to the host interface master is made through the IOLink protocol. Functionally this compact, costeffective module is comparable with a passive splitter box: It takes digital and analog sensor signals and passes them over the IOLink interface. 1.2 Structure of the guide 1.3 Typographical conventions Enumerations Actions Syntax The Guide is organized so that the sections build on one another. Section 2 : Basic safety information. Section 3 : The main steps for installing the device. Section 4: IOLink, parameter and process data for the device. Section 5: Technical data for the device.. The following typographical conventions are used in this Guide. Enumerations are shown in list form with bullet points. Entry 1, Entry 2. Action instructions are indicated by a preceding triangle. The result of an action is indicated by an arrow. Action instruction 1. Action result. Action instruction 2. Numbers: Decimal numbers are shown without additional indicators (e.g. 123), Hexadecimal numbers are shown with the additional indicator hex (e.g. 00 hex). Crossreferences Crossreferences indicate where additional information on the topic can be found (see Section 5 "Technical Data ). 1.4 Symbols Note! This symbol indicates a security notice which most be observed. Note tip This symbol indicates general notes. 1.5 Abbreviations BNI DPP I/OPort EMC FE IOL LSB MSB SPDU Balluff Network Interface Direct Parameter Page Digital input/output port Electromagnetic Compatibility Function ground IOLink Least Significant Bit Most Significant Bit Service Protocol Data Unit www.balluff.com 2

2 Safety 2.1 Intended use The BNI IOL is a decentralized sensor input module which is connected to a host IOLink master over an IOLink interface. 2.2 General safety notes Installation and startup Installation and startup are to be performed only by trained specialists. Any damage resulting from unauthorized manipulation or improper use voids the manufacturer's guarantee and warranty. The device is an equipment in accordance with EMC Class A. Such equipment may generate RF noise. The operator must take precautionary measures accordingly. The device must be powered only using an approved power supply (see Section 5 Technical Data ). Only approved cables may be used. Operation and testing The operator is responsible for observing local prevailing safety regulations. When defects and nonclearable faults in the device occur, take it out of service and secure against unauthorized use. Approved use is ensured only when the housing is fully installed. 2.3 Meaning of the warnings Note! The pictogram used with the word "Caution" warns of a possible hazardous situation affecting the health of persons or equipment damage. Ignoring these warnings can result in injury or equipment damage. Always observe the described measures for preventing this danger. www.balluff.com 3

IOLink SensorHub / Actuator Hub 3 Getting Started 3.1 Connection overview 15 16 17 7 1 14 55 13 1 2 3 12 4 5 11 1 6 7 10 8 9 1 Mounting hole 2 IOLink interface 3 Digital I/O Port 1 4 Digital I/O Port 3 5 StatusLED: Digital I/O Port 5 (pin 2) 6 Digital I/O Port 5 7 StatusLED: Digital I/O Port 5 (pin 4) 8 Digital I/O Port 7 9 Status LED Power Supply 10 Digital I/O Port 6 11 Digital I/O Port 4 12 Digital I/O Port 2 13 Digital I/O Port 0 14 Label 15 StatusLED IOLink 16 Status LED actor power supply 17 Function ground connection www.balluff.com 4

3 Getting Started 3.2 Mechanical connection 3.3 Electrical connection The BNI IOL modules are attached using 3 M4 screws (Item 1, Fig. 31/32). The BNI IOL302xxxK006 modules require no separate supply voltage connection. Power is provided through the IOLink interface by the host IOLink Master. 3.4 Function ground The modules are provided with a ground terminal. Connect Sensor Hub module to the ground terminal. Note! The FE connection from the housing to the machine must be lowimpedance and as short as possible. 3.5 IOLink connection The IOLink connection is made using an M12 connector (Acoded, male). IOLink (M12, Acoded, male) Pin Function 1 Supply voltage Us, +24 V, max. 1.3 A 2 Actor power supply Ua, +24V, max 1.6A 3 GND, reference potential 4 C/Q, IOLink data transmission channel Note! Us should be maximum 0.5 V higher than Ua www.balluff.com 5

IOLink SensorHub / Actuator Hub 3 Getting Started Sensor Hub connection Connection protection ground to FE terminal, if present. Connect the incoming IOLink line to the Sensor Hub. Note! A standard sensor cable is used for connecting to the host IOLink Master. Module versions Sensor Hub Version Digital Port BNI IOL302000K006 16 Inputs / Outputs configurable BNI IOL302S01K006 16 Inputs / Outputs configurable, with single channel monitoring BNI IOL302000K006C01 16 Inputs / Outputs configurable, with identification BNI IOL302S01K006C01 16 Inputs / Outputs configurable, with single channel monitoring and identification 3.6 Digital Sensors Digital Input / Output port (M12, Acoded, female) Pin Function 1 +24 V, 200 ma 2 Standard Input / Output 3 0 V, GND 4 Standard Input / Output 5 FE Note! For the digital sensor inputs follow the input guideline per EN 611312, Type 2. Note! Digital Outputs can be loaded with maximum 350 ma. Total current of actuator supply is maximum 1.6 A Note! Unused I/O port sockets must be fitted with cover caps to ensure IP67 protection rating. www.balluff.com 6

Input Port 7 Pin 4 Input Port 6 Pin 4 Input Port 5 Pin 4 Input Port 4 Pin 4 Input Port 3 Pin 4 Input Port 2 Pin 4 Input Port 1 Pin 4 Input Port 0 Pin 4 Input Port 7 Pin 2 Input Port 6 Pin 2 Input Port 5 Pin 2 Input Port 4 Pin 2 Input Port 3 Pin 2 Input Port 2 Pin 2 Input Port 1 Pin 2 Input Port 0 Pin 2 4 IOLink Interface 4.1 IOLink Data BNI IOL302000K006 Baudrate COM2 (38,4 kbaud) Frame type 2.V Minimum cycle time 3.5 ms Process data length 2 byte input, 2 byte output BNI IOL302S01K006 Baudrate COM2 (38,4 kbaud) Frame type 2.V Minimum cycle time 5 ms Process data length 8 byte input, 2 byte output BNI IOL302000K006C01 Baudrate COM2 (38,4 kbaud) Frame type 2.V Minimum cycle time 4 ms Process data length 4 byte input, 2 byte output BNI IOL302S01K006C01 Baudrate COM2 (38,4 kbaud) Frame type 2.V Minimum cycle time 5.5 ms Process data length 10 byte input, 2 byte output 4.2 Process data inputs BNI IOL302000K006 Process data length 2 Byte: Byte 0 1 www.balluff.com 7

Port 7 Pin 4 Port 6 Pin 4 Port 5 Pin 4 Port 4 Pin 4 Port 3 Pin 4 Port 2 Pin 4 Port 1 Pin 4 Port 0 Pin 4 Port 7 Pin 2 Port 6 Pin 2 Port 5 Pin 2 Port 4 Pin 2 Port 3 Pin 2 Port 2 Pin 2 Port 1 Pin 2 Port 0 Pin 2 Port 7 Pin 4 Port 6 Pin 4 Port 5 Pin 4 Port 4 Pin 4 Port 3 Pin 4 Port 2 Pin 4 Port 1 Pin 4 Port 0 Pin 4 Port 7 Pin 2 Port 6 Pin 2 Port 5 Pin 2 Port 4 Pin 2 Port 3 Pin 2 Port 2 Pin 2 Port 1 Pin 2 Port 0 Pin 2 Port 7 Port 6 Port 5 Port 4 Port 3 Port 2 Port 1 Port 0 Us > Ua Undervoltage Ua Undervoltage Us Input Port 7 Pin 4 Input Port 6 Pin 4 Input Port 5 Pin 4 Input Port 4 Pin 4 Input Port 3 Pin 4 Input Port 2 Pin 4 Input Port 1 Pin 4 Input Port 0 Pin 4 Input Port 7 Pin 2 Input Port 6 Pin 2 Input Port 5 Pin 2 Input Port 4 Pin 2 Input Port 3 Pin 2 Input Port 2 Pin 2 Input Port 1 Pin 2 Input Port 0 Pin 2 IOLink SensorHub / Actuator Hub 4 IOLink Interface BNI IOL302S01K006 Process data length 8 Byte: Byte 0 1 Byte 2 3 Byte 4 5 Byte 6 7 www.balluff.com 8

Input Port 7 Pin 4 Input Port 6 Pin 4 Input Port 5 Pin 4 Input Port 4 Pin 4 Input Port 3 Pin 4 Input Port 2 Pin 4 Input Port 1 Pin 4 Input Port 0 Pin 4 Input Port 7 Pin 2 Input Port 6 Pin 2 Input Port 5 Pin 2 Input Port 4 Pin 2 Input Port 3 Pin 2 Input Port 2 Pin 2 Input Port 1 Pin 2 Input Port 0 Pin 2 4 IOLink Interface BNI IOL302000K006C01 Process data length 4 Byte: Byte 4 5 Byte 2 3 Identification byte 0 Identification byte 1 www.balluff.com 9

Port 7 Pin 4 Port 6 Pin 4 Port 5 Pin 4 Port 4 Pin 4 Port 3 Pin 4 Port 2 Pin 4 Port 1 Pin 4 Port 0 Pin 4 Port 7 Pin 2 Port 6 Pin 2 Port 5 Pin 2 Port 4 Pin 2 Port 3 Pin 2 Port 2 Pin 2 Port 1 Pin 2 Port 0 Pin 2 Port 7 Pin 4 Port 6 Pin 4 Port 5 Pin 4 s Port 4 Pin 4 Port 3 Pin 4 Port 2 Pin 4 Port 1 Pin 4 Port 0 Pin 4 Port 7 Pin 2 Port 6 Pin 2 Port 5 Pin 2 Port 4 Pin 2 Port 3 Pin 2 Port 2 Pin 2 Port 1 Pin 2 Port 0 Pin 2 Port 7 Port 6 Port 5 Port 4 Port 3 s Port 2 Port 1 Port 0 Us > Ua Undervoltage Ua Undervoltage Us Input Port 7 Pin 4 Input Port 6 Pin 4 Input Port 5 Pin 4 Input Port 4 Pin 4 Input Port 3 Pin 4 Input Port 2 Pin 4 Input Port 1 Pin 4 Input Port 0 Pin 4 Input Port 7 Pin 2 Input Port 6 Pin 2 Input Port 5 Pin 2 Input Port 4 Pin 2 Input Port 3 Pin 2 Input Port 2 Pin 2 Input Port 1 Pin 2 Input Port 0 Pin 2 IOLink SensorHub / Actuator Hub 4 IOLink Interface BNI IOL302S01K006C01 Process data length 10 Byte: Byte 0 1 Byte 2 3 Byte 4 5 Byte 6 7 Byte 8 9 Identification byte 0 Identification byte 1 www.balluff.com 10

Identification Data Read only Output Port 7 Pin 4 Output Port 6 Pin 4 Output Port 5 Pin 4 Output Port 4 Pin 4 Output Port 3 Pin 4 Output Port 2 Pin 4 Output Port 1 Pin 4 Output Port 0 Pin 4 Output Port 7 Pin 2 Output Port 6 Pin 2 Output Port 5 Pin 2 Output Port 4 Pin 2 Output Port 3 Pin 2 Output Port 2 Pin 2 Output Port 1 Pin 2 Output Port 0 Pin 2 4 IOLink Interface 4.3 Processdata / Output data BNI IOL302 Process data length 2 Byte Byte 0 1 4.4 Parameter data/ Onrequest data 08hex Range Default value 0378hex DPP SPDU Parameter Data Index Index Subindex length 07hex Vendor ID 2 Byte 09hex Device ID 3 Byte 05010Bhex(302000K006) 0Ahex 0Bhex 05010Chex(302000K006 C01) 05010Dhex(302S01K006) 05010Ehex(302S01K006 C01) 10hex 0 Vendor 8 Byte BALLUFF Name 11hex 0 Vendor text 16 Byte www.balluff.com 12hex 0 Product 20/24 BNI IOL302000K006 Name Byte 13hex 0 Product ID 7 Byte BNI005L (302000K006) BNI005U (302000K006 C01) BNI005T (302S01K006) BNI005W (302S01K006 C01) 14hex 0 Product text 16 Byte IOLink Sensor/Actor Hub 16hex Hardware Revision 17hex 0 Firmware Revision 18hex 0 Application Specific Tag 3 Byte 3 Byte 32 Byte 0hex 16x FFFFhex www.balluff.com 11

Parameter Data IOLink SensorHub / Actuator Hub 4 IOLink Interface DPP SPDU Parameter Data Range Default Index Index Subindex length value 40hex 0 64 116 Inversion 2 Byte 0hex FFFFhex 0hex 41hex 0 65 116 Port Direction 2 Byte 0hex FFFFhex 0hex 42hex 0 66 18 Fault State Pin 4 2 Byte 0hex FFFFhex 0hex 43hex 0 67 18 Fault State Pin 2 2 Byte 0hex FFFFhex 0hex 44hex 0 68 116 Supply Monitoring 2 Byte 0hex FF0Dhex 45hex 0 69 116 Actuator short 2 Byte 0hex FFFFhex 46hex 0 70 116 Actuator warning 2 Byte 0hex FFFFhex 47hex 71 60hex 96 * Only at BNI IOL302xxxK006C01 0 Us>Ua warning 2 Byte 0hex 1hex 1hex 0 Identification * 2 Byte 0hex FFFFhex 0hex Note! The Index 60, which includes the identification bytes, is not part of the parameter server list for the data storage. If the parameter server of the IOLink master port is activated, this Index will not be assigned during data storage, neither from the IOLink Device to the master port, nor from the master port to the IOLink device. www.balluff.com 12

Fault State Port 3 Pin 4 Fault State Port 2 Pin 4 Fault State Port 1 Pin 4 Fault State Port 0 Pin 4 Fault State Port 7 Pin 4 Fault State Port 6 Pin 4 Fault State Port 5 Pin 4 Fault State Port 4 Pin 4 Direction Port 7 Pin 4 Direction Port 6 Pin 4 Direction Port 5 Pin 4 Direction Port 4 Pin 4 Direction Port 3 Pin 4 Direction Port 2 Pin 4 Direction Port 1 Pin 4 Direction Port 0 Pin 4 Direction Port 7 Pin 2 Direction Port 6 Pin 2 Direction Port 5 Pin 2 Direction Port 4 Pin 2 Direction Port 3 Pin 2 Direction Port 2 Pin 2 Direction Port 1 Pin 2 Direction Port 0 Pin 2 Inversion Port 7 Pin 4 Inversion Port 6 Pin 4 Inversion Port 5 Pin 4 Inversion Port 4 Pin 4 Inversion Port 3 Pin 4 Inversion Port 2 Pin 4 Inversion Port 1 Pin 4 Inversion Port 0 Pin 4 Inversion Port 7 Pin 2 Inversion Port 6 Pin 2 Inversion Port 5 Pin 2 Inversion Port 4 Pin 2 Inversion Port 3 Pin 2 I Inversion Port 2 Pin 2 Inversion Port 1 Pin 2 Inversion Port 0 Pin 2 4 IOLink Interface Inversion Inversion of the input signals: Byte 0 1 Sub Index 8 7 6 5 4 3 2 1 16 15 14 13 12 11 10 9 Inversion Port (x): 0 Normal 1 Inverted Port Direction Byte 0 1 Sub Index 8 7 6 5 4 3 2 1 16 15 14 13 12 11 10 9 Direction Port (x) 0 Input 1 Output Fault State Pin 4 Byte 0 1 Sub Index 4 3 2 1 8 7 6 5 www.balluff.com 13

Fault State Port 3 Pin 2 Fault State Port 2 Pin 2 Fault State Port 1 Pin 2 Fault State Port 0 Pin 2 Fault State Port 7 Pin 2 Fault State Port 6 Pin 2 Fault State Port 5 Pin 2 Fault State Port 4 Pin 2 IOLink SensorHub / Actuator Hub 4 IOLink Interface Fault State Pin 2 Byte 0 1 Sub Index 4 3 2 1 8 7 6 5 Value bin dec Output State 00 0 Ausgang ist 0V 01 1 Ausgang ist 24V 10 2 Aktueller Zustand wird gehalten 11 3 Nicht definiert www.balluff.com 14

Enable Us>Ua Port 7 Pin 4 Port 6 Pin 4 Port 5 Pin 4 Port 4 Pin 4 Port 3 Pin 4 Port 2 Pin 4 Port 1 Pin 4 Port 0 Pin 4 Port 7 Pin 2 Port 6 Pin 2 Port 5 Pin 2 Port 4 Pin 2 Port 3 Pin 2 Port 2 Pin 2 Port 1 Pin 2 Port 0 Pin 2 Port 7.0 Port 6.0 Port 5.0 Port 4.0 Port 3.0 Port 2.0 Port 1.0 Port 0.0 Port 7.1 Port 6.1 Port 5.1 Port 4.1 Port 3.1 Port 2.1 Port 1.1 Port 0.1 Port 7 Port 6 Port 5 Port 4 Port 3 Port 2 Port 1 Port 0 Us > Ua+0.5 Undervoltage Ua Undervoltage Us 4 IOLink Interface Voltage Monitoring Byte 0 Byte 1 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Short circuit at Port x between Pin 1 and Pin 3 Port x = 1 Where x=0...7 Actuator short Byte 0 Byte 1 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Short circuit at Signalport at Port x Actuator warning Byte 0 Byte 1 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Actuator warning by Signalport at Port x Us>Ua Byte 0 7 6 5 4 3 2 1 0 When warning is enabled, and Us > Ua (> = 0.5V), a event will be sent. Identification Byte 0 Byte 1 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Identification Byte 0 Identification Byte 1 www.balluff.com 15

IOLink SensorHub / Actuator Hub 4 IOLink Interface 4.5 Errors Error Code 0x8011 Index not available 0x8012 Subindex not available 0x8023 Access Denied 0x8033 Parameter length overrun 0x8034 Parameter length underrun 0x8035 Function not available 4.6 Events IOLink Revision 1.0 Event Code 0x5112 Low sensor voltage (US) 0x5114 Low actuator voltage (UA) 0x5410 Short circuit 0x1800 Us > Ua (> = 0.5V) IOLink Revision 1.1 Event Code 0x5111 Low sensor voltage (US) 0x5112 Low actuator voltage (UA) 0x7710 Short circuit 0x1800 Us > Ua (> = 0.5V) www.balluff.com 16

5 Technical Data 5.1 Dimensions 5.2 Mechanical data Housing Material Plastic, transparent IOLinkPort M12, Acoded, male InputPorts Enclosure rating Weight Dimensions (L W H, excluding connector) 8x M12x1, Acoded, female IP67 (only when pluggedin and threadedin) 90 g 115 50 30,8 mm 5.3 Electrical data Operating voltage 18... 30,2 V DC, per EN 611312 Ripple < 1 % Current draw without load 65 ma 5.4 Operating conditions Operating temperature 5 C +55 C Storage temperature 25 C +70 C EMC EN 6100042/3/4/5/6 Severity level 3A/3A/4A/2A/3A Enclosure rating IP67 (only when pluggedin and threadedin) Vibration/shock EN 60068 Teil 26/27 www.balluff.com 17

IOLink SensorHub / Actuator Hub 5 Technical Data 5.5 Function indicators COM UA LED 1 LED 2 US Module LEDs Status Function IOLink Green No Communication Communication Green negative pulsed Communication OK Red Communication line overload Off Module unpowered Us LED Green Module power is OK Green slowly flashing Sensor supply Green rapidly flashing Module power supply < 18 V Off Module unpowered Ua LED Green Actuator power supply OK Green slowly flashing Actuator short circuit Green rapidly flashing Undervoltage < 18 V Off No Actuator power supply Digital Input LEDs LED 2, Input Pin 4 and LED 1, Input Pin 2 Status Function Yellow Input signal = 1 Sensor power supply short circuit, Red Actuator short circuit Actuator warning Off Input / Output signal = 0 www.balluff.com 18

6 Appendix 6.1 Type designation code BNI IOL302xxxK006C01 Balluff Network Interface IOLink interface Functions 302 = 16 inputs / Outputs Version 000 = Standard version S01 = Single channel monitoring Mechanical configuration K006 =Plastic housing, Connectors: BUS and Power supply: 1x M12x1, external thread Input ports: 8x M12x1, internal thread Extra functions C01 = Identification 6.2 Order information Type Order Code BNI IOL302000K006 BNI005L BNI IOL302S01K006 BNI005T BNI IOL302000K006C01 BNI005U BNI IOL302S01K006C01 BNI005W www.balluff.com 19

IOLink SensorHub / Actuator Hub Notes www.balluff.com 20

Nr. 887780 E Edition 1209 Revised Edition 1208 Subject to modification www.balluff.com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.f. Germany Tel. +49 7158 1730 Fax +49 www.balluff.com 7158 5010 balluff@balluff.de