HP ProLiant Storage Server iscsi Feature Pack

Similar documents
HP MSA2000 Family VDS and VSS Hardware Providers installation guide

HP StorageWorks Performance Advisor. Installation Guide. Version 1.7A

HP StorageWorks 4000/6000/8000 Enterprise Virtual Array connectivity for Sun Solaris installation and reference guide

MSA1500csReleaseNotes8_ txt MSA1500cs ReleaseNotes. hp StorageWorks Modular Smart Array 1500 cs Release Notes. Third Edition (February 2005)

ProLiant Cluster HA/F500 for Enterprise Virtual Array Introduction Software and Hardware Pre-Checks Gathering Information...

HP StorageWorks Continuous Access EVA 2.1 release notes update

Configuring the HP StorageWorks Modular Smart Array 1000 and 1500cs for external boot with Novell NetWare New Installations

Data Protector Express Hewlett-Packard Company

HP ProLiant DL580 Generation 2 and HP ProLiant ML570 Generation 2 Server Hot-Add Memory. July 2003 (Second Edition) Part Number

HP Video Over Ethernet. User Guide

QuickSpecs. What's New. Models. ProLiant Essentials Server Migration Pack - Physical to ProLiant Edition. Overview

HP ProLiant Essentials RDMA for HP Multifunction Network Adapters User Guide

HP Mobile Remote Control (Select Models Only) User Guide

HP StorageWorks Using the QLogic HBA Driver for Single-path or Multi-path Failover Mode on Linux Systems

Configuring the MSA1000 for Linux or NetWare Environments

hp StorageWorks Using the QLogic Driver for Single-path or Multi-path Failover Mode on Linux Systems

Release Notes: ProCurve Mobility Manager Version 1.0, Update 1

HP Point of Sale (POS) Peripherals Configuration Guide Barcode Scanner

ProLiant CL380 Software User Guide. Fourth Edition (December 2000) Part Number Compaq Computer Corporation

Virtual Recovery Assistant user s guide

QuickSpecs. What's New. Models. HP ProLiant Essentials Performance Management Pack version 4.5. Overview. Retired

HP StorageWorks Enterprise Virtual Array 4400 to 6400/8400 upgrade assessment

QuickSpecs SmartStart TM Release 6.0

HP LeftHand SAN Solutions

HP Storage Manager User Guide. May 2005 (First Edition) Part Number

Modem and Networking compaq notebook series

HP Insight Remote Support Advanced HP StorageWorks P4000 Storage System

Generating Unique System IDs (SIDs) after Disk Duplication using Altiris Deployment Solution

HP StorageWorks Enterprise Virtual Array

Retired. ProLiant iscsi Acceleration Software Pack for Embedded Multifunction Server Adapters Overview

HP StorageWorks Using the QLogic HBA driver for single-path or multipath failover mode on Linux systems application notes

Release Notes: ProCurve Network Immunity Manager Version 1.0, Update 3

QuickSpecs. Models. Overview

HPE VMware ESXi and vsphere 5.x, 6.x and Updates Getting Started Guide

HP ProLiant Agentless Management Pack (v 3.2) for Microsoft System Center User Guide

HP VMware ESXi and vsphere 5.x and Updates Getting Started Guide

HP ProLiant ML370 G4 Storage Server

HP StorageWorks Partitioning in an EBS Environment Implementation Guide

HP D6000 Disk Enclosure Direct Connect Cabling Guide

HP UFT Connection Agent

Upgrading the MSA1000 for Enhanced Features

HP integrated Citrix XenServer Online Help

TippingPoint Best Practice Guide. RADIUS PEAP Configuration for IPS Devices and Cisco ACS. Version:

Release Notes: ProCurve Identity Driven Manager Version 2.0, Update 2

HP LaserJet P3005 Series Printers. Getting Started Guide

Quick Setup & Getting Started

Getting Started. HP Business PCs

OpenVMS Management Station Overview and Release Notes

The use of the HP SAS Expander Card requires a minimum of 256MB cache on the SA-P410 or SA-P410i Controller.)

HP Supporting the HP ProLiant Storage Server Product Family.

Target Environments The Smart Array 6i Controller offers superior investment protection to the following environments: Non-RAID

HP Storage Provisioning Manager (SPM) Version 1.3 User Guide

VERITAS StorageCentral 5.2

SQL Server Installation and Configuration Guide. Abstract

HP P4000 SAN Solution User Guide

HP Server tc2110 Network Operating System Installation Guide

HP LeftHand P4000 Virtual SAN Appliance in an HP BladeSystem environment solution guide

Marvell BIOS Utility User Guide

Models PDC/O5000 9i W2K Cluster Kit B24

DtS Data Migration to the MSA1000

HP ProLiant ML150 Server NOS Installation and Software Guide. November 2003 (Second Edition) Part Number

Guest Management Software Administrator Guide. Installation and Getting Started Guide Administrator Guide

Computer Setup (F10) Utility Guide HP Compaq d220 and d230 Microtower

HP Data Protector Media Operations 6.11

HP Database and Middleware Automation

NonStop Development Environment for Eclipse 4.0 Debugging Supplement

HP StorageWorks. EVA Virtualization Adapter administrator guide

HP Accelerated iscsi for Multifunction Network Adapters User Guide

QuickSpecs. HP StorageWorks Command View SDM. Models. Models Feature List

QuickSpecs. Models. HP Smart Array P400i Controller. Overview

Installation and Configuration Guide

TippingPoint Intrusion Prevention System Release Notes

QuickSpecs. What's New HP 120GB 1.5Gb/s SATA 5400 rpm SFF HDD. HP Serial-ATA (SATA) Hard Drive Option Kits. Overview

QuickSpecs. Models. Overview

HP Internet Usage Manager Software Release Notes

Configuring Security Mitigation Settings for Security Bulletin HPSBPI03569 Protecting Solution Installation Settings

Configuring Embedded LDAP Authentication

HP ProLiant Hardware Inventory Tool for Configuration Manager 2007 User Guide

Replacing the Battery HP t5730 and t5735 Thin Clients

HP Factory-Installed Operating System Software for Microsoft Windows Server 2003 R2 User Guide

HP ALM Client MSI Generator

Fully integrated and tested with most ProLiant servers and management software. See list of servers with each adapter specifications.

HP StorageWorks Modular Smart Array 1500 cs application note

QuickSpecs. What's New Support for HP software and hardware server support. Models. HP Insight Server Migration software for ProLiant v.3.

Guidelines for using Internet Information Server with HP StorageWorks Storage Mirroring

Retired. Microsoft iscsi Software Target for ProLiant Storage Servers Overview

QuickSpecs. What's New. Models. Overview

HP Network Node Manager i Software Step-by-Step Guide to Scheduling Reports using Network Performance Server

Configuring RAID with HP Z Turbo Drives

HP Insight Control for Microsoft System Center Installation Guide

QLogic iscsi Boot for HP FlexFabric Adapters User Guide

Achieve Patch Currency for Microsoft SQL Server Clustered Environments Using HP DMA

QuickSpecs. VMware Virtualization Software For HP ProLiant Servers. Overview

Computer Setup (F10) Utility Guide HP Elite 7000 MT Series PCs

HP Service Test Management

QuickSpecs. HP SANworks Storage Resource Manager. Overview. Model HP SANworks Storage Resource Manager v4.0b Enterprise Edition.

CA ehealth Integration for HP OpenView

Models Smart Array 6402/128 Controller B21 Smart Array 6404/256 Controller B21

HP Data Protector Integration with Autonomy IDOL Server

System information update for system board replacement events

Transcription:

Release Notes HP ProLiant Storage Server iscsi Feature Pack Product Version: Version 1.51 First Edition (November 2004) Part Number: T3669-90902 This document provides information not covered elsewhere in user documentation for the HP ProLiant Storage Server iscsi Feature Pack (V1.51). Refer to this document if you plan to install, configure, and use this application. For other related documentation, access the HP storage web site at: http://www.hp.com/country/us/eng/prodserv/storage.html.

Copyright 2004 Hewlett-Packard Development Company, L.P. Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. This document contains proprietary information, which is protected by copyright. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of Hewlett-Packard. The information contained in this document is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Compaq Computer Corporation is a wholly-owned subsidiary of Hewlett-Packard Company. Microsoft, MS-DOS, MS Windows, Windows, and Windows NT are U.S. registered trademarks of Microsoft Corporation. Hewlett-Packard Company shall not be liable for technical or editorial errors or omissions contained herein. The information is provided as is without warranty of any kind and is subject to change without notice. The warranties for Hewlett-Packard Company products are set forth in the express limited warranty statements for such products. Nothing herein should be construed as constituting an additional warranty. HP ProLiant Storage Server iscsi Feature Pack Release Notes First Edition (November 2004) Part Number: T3669-90902 2 HP ProLiant Storage Server iscsi Feature Pack Release Notes

This document is intended for customers who purchased the HP ProLiant Storage Server iscsi Feature Pack Version 1.51. These release notes cover the following major topics: Installation issues, page 4 iscsi Feature Pack issues, page 7 Application Storage Manager issues, page 9 Troubleshooting Tips, page 12 For general information on using the iscsi Feature Pack, please refer to: Online Help (accessible through the software) iscsi Feature Pack User Guide (on the Documentation CD) Application Storage Manager User Guide (on the Documentation CD) White papers and best practices documents are available on the HP web site at: http://www.hp.com/support/storage, under NAS Upgrades/ Options/Accessories. HP ProLiant Storage Server iscsi Feature Pack Release Notes 3

Installation issues Installation issues This section provides information related to the installation of the HP ProLiant Storage Server iscsi Feature Pack programs. The HP ProLiant Storage Server iscsi Feature Pack Installer The iscsi Feature Pack installer presents only those software options that are compatible with the operating system of the destination server. HP-recommended features are checked during the installation process. See the description of each feature to find out more information and to see if the installer detects any previous installations of this feature. Supported Configurations Table 1: Supported servers The Installation CD contains both the iscsi Feature Pack target software and Application Storage Manager (ASM) software. The software is supported on the following HP storage servers: Software Supported servers iscsi Feature Pack HP StorageWorks NAS 1200 HP StorageWorks NAS 2000 HP StorageWorks NAS 4000 HP ProLiant DL100 Storage Server/HP StorageWorks NAS 1500 HP ProLiant DL380 G4 Storage Server (SAN and direct attach storage models) HP ProLiant ML110 Storage Server/HP StorageWorks NAS 500 HP ProLiant ML350 G4 Storage Server HP ProLiant ML370 G4 Storage Server Application Storage Manager HP StorageWorks NAS 2000 HP ProLiant DL100 Storage Server/HP StorageWorks NAS 1500 HP ProLiant DL380 G4 Storage Server (except SAN storage models) HP ProLiant ML110 Storage Server/HP StorageWorks NAS 500 HP ProLiant ML350 G4 Storage Server HP ProLiant ML370 G4 Storage Server 4 HP ProLiant Storage Server iscsi Feature Pack Release Notes

Installation issues Installing Application Storage Manager Using the installation program on the CD, install iscsi Feature Pack first, before installing ASM. ASM installs software on both the HP Windows Storage Server (WSS) as well as any Exchange servers in your environment whose Exchange data (Mail Stores, Public Stores, and Logs) you plan to host on the WSS. During the installation process: If your storage server is not compatible with ASM, the Select Features section of the installer is blank. Click Next to continue the installation. You are prompted for an administrator user name and password. This user account can be a local administrator or a domain administrator. Entering a domain administrator account provides the additional ability for ASM to automatically detect all Exchange servers in your domain. While installing the ASM Exchange Agent on your Exchange server, select the iscsi Snapshot components only if you have purchased and obtained license keys to enable them. If you receive the message, Service Already Exists, ASM is already installed. Uninstall ASM using Start > Control Panel > Add or Remove Programs, and then reinstall it. After installing ASM, access it from the Start menu of your storage server by selecting Start > Programs > HP Application Storage Manager > HP Application Storage Manager. Licensing the iscsi Feature Pack Before running ASM, license the iscsi Feature Pack. A License Key Entitlement Certificate is included in your iscsi Feature Pack software kit. To install the license: 1. Load the Windows Storage Server WebUI. 2. Log in (if necessary). 3. Click the iscsi tab. 4. Select Configuration. 5. Select License and Version Information. 6. Enter your license key, and then click OK. HP ProLiant Storage Server iscsi Feature Pack Release Notes 5

Installation issues After installing ASM, access it from within the Start menu on the Windows Storage Server (Start > Programs > HP Application Storage Manager > HP Application Storage Manager. Virtual Disk Service (VDS) does not start on Exchange server after installation Occasionally, after installing the ASM Agent on the Exchange server, the Microsoft Virtual Disk Service does not start. The VDS should always be running if the ASM Agent is running. To verify the service is running: 1. Select Start > Programs > Administrative Tools > Services. 2. Scroll down and select Virtual Disk Service. 3. Verify that the service is running. If it is not running, right-click Virtual Disk Service, and select Start. Unsigned driver installation During the installation of the iscsi Feature Pack, you must install the unsigned driver. This driver is a SCSI HBA emulation driver and is necessary for the proper operation of the iscsi Feature Pack. If you do not install this driver, the iscsi Feature Pack installation fails. To correct this situation, go to the Support/Tools directory on your iscsi Feature Pack Installation CD and run the FSRepair.exe utility. Then, reboot the storage server, and reinstall the iscsi Feature Pack with the unsigned driver. 6 HP ProLiant Storage Server iscsi Feature Pack Release Notes

iscsi Feature Pack issues iscsi Feature Pack issues The following section provides information related to the iscsi Feature Pack target software. Shadow Copy Web UI page does not display properly After installing the iscsi Feature Pack target software, the Windows Storage Server (WSS) 2003 Web UI shadow copy page may not display properly. To correct this, exit the WSS Web UI, and use the standard Microsoft shadow copy tools in Windows Explorer or in My Computer. iscsi Oracle 10g Snapshot Agent availability Oracle snapshot agents are currently available for Oracle versions 8i and 9i only. Oracle 10g snapshot agents will be available at a later date after the full quality assurance program is complete. Logical drive is not displayed as available iscsi storage A new logical drive may not be displayed in the iscsi Logical Unit or storage pool tabs. This occurs after a logical drive is deleted through the hp Array Configuration Utility before deleting the logical unit or storage pool information in the iscsi tab. iscsi is unable to use this logical drive until the administrator removes the information from the logical drive. Complete the following steps from a DOS prompt to correct this problem: 1. Change directory to C:\Program Files\HP\ProLiant Server iscsi Feature Pack. 2. Run StopiSCSIServer.bat. 3. Use Disk Manager to initialize the new logical drive. 4. Change directory to C:\Program Files\HP\ProLiant Server iscsi Feature Pack\etc\<Computer Name>. 5. Copy ipstor.conf to ipstor.conf.bak. 6. Edit ipstor.conf to remove the Physical Devices marked Residual Virtual Device. HP ProLiant Storage Server iscsi Feature Pack Release Notes 7

iscsi Feature Pack issues <PhysicalDev name="hp:logical" wwid="" type="direct-access" isnew="false" owner="electra" devname="" category="residual Virtual Device" guid="00000000-0000-0000-0000-000000000000" fsid="fa1c0300-7414-3a66-2fee-863220bb3dbb" key="1096304998" fsidrelianceenabled="true" poolid="0" queuedepth="8" connectiontype="" controllertype="generic" primaryid="" alternateid="" isfsidreliable="true" ntdiskid="3"> <IPStorPartition checksum=""> <DynamicDiskSegment guid="91be8fde-66f8-7146-86cf-7894bcbfb952" firstsector="14336" lastsector="20479" owner="electra" dataset="1096065190" seqno="0" islastsegment="true" sectorsize="512" type="umap" timestamp="1096065190" devicename="lu9"/> <DynamicDiskSegment guid="91be8fde-66f8-7146-86cf-7894bcbfb952" firstsector="20480" lastsector="2048159" owner="electra" dataset="1096065190" seqno="1" islastsegment="true" sectorsize="512" type="san" timestamp="1096065190" devicename="lu9"/> </IPStorPartition> <SCSIAddress adapter="3" channel="0" id="10" lun="0"/> <SCSIAliasing/> <Geometry startingsector="14336" endingsector="6144479" sectorsize="512"/> <InquiryString>0000000233000002HP LOGICAL VOLUME 1.92</InquiryString> <Comments/> </PhysicalDev> Figure 1: Example of a Residual Physical Device Entry 7. Change directory to C:\Program Files\HP\ProLiant Server iscsi Feature Pack. 8. Run StartiSCSIServer.bat. 8 HP ProLiant Storage Server iscsi Feature Pack Release Notes

Application Storage Manager issues Application Storage Manager issues The following section provides information related to the ASM component of the iscsi Feature Pack. Running the Host Storage Groups Wizard Task View dialog iscsi license key error The Host Storage Groups Wizard instructions on the Mailstore Database Capacity Planning screen should read: Enter the amount of space needed for the Mailstore database. Also, on the same screen, the number of mailbox and mailbox size values are theoretical extremes for informational purposes only. The actual number of mailboxes and their sizes are not changed by ASM. The Task View dialog is displayed automatically for any task that takes longer than two seconds to complete. You can manually launch it at any time from the ASM toolbar (Tools > Task Viewer). After storage system changes are made, the Task Viewer window opens (if the task is longer than two seconds) and displays the task list that the system is running, and the status of those tasks. If ASM is launched before installing the iscsi license key, a warning box displays that iscsi is not licensed. A hyperlink to the iscsi License Key web page is provided. Click the link to install the license. After the license is installed, clicking OK displays an error page stating that the web page has timed out or you might have opened this page without opening the default home page. If you receive this error, the iscsi license key installed successfully. You can ignore the error and begin using ASM. Dynamic Disks are not supported ASM and iscsi Feature Pack software do not support Windows Dynamic Disks configured on the storage server. HP ProLiant Storage Server iscsi Feature Pack Release Notes 9

Application Storage Manager issues Migrated Exchange Storage Group components display as size zero After migrating Exchange Storage Group components to the storage server, ASM displays the component size as zero. This occurs because the actual size of the component data has not been determined. To update the component size display, perform one of the following: Restart ASM. From the menu bar, select Actions > Refresh. Wait up to one hour until a refresh occurs automatically. Hot Spare Disk gets assigned to all virtual arrays In order to migrate Exchange Storage Group components to the storage server, ASM may configure a virtual array with a Hot Spare Disk. If the Hot Spare Disk is assigned to the newly created virtual array, it is assigned to all existing virtual arrays on the same controller not just the virtual array that was created. To remove the Hot Spare Disk from virtual arrays where it is not wanted: 1. Select Start > Programs > Compaq System Tools > hp Array Configuration Utility. 2. After running hp Array Configuration Utility, remove unwanted assignments. Duplicate Exchange Storage Group components displayed If Exchange Storage Group components are migrated to the storage server, then migrated off the storage server, and then back onto the storage server a second time, ASM displays duplicate components. To remove the duplicate Exchange components from view: 1. Right-click the component to remove from view. 2. Select Remove from view. 3. Click OK to confirm the action. 10 HP ProLiant Storage Server iscsi Feature Pack Release Notes

Application Storage Manager issues Stacked bar chart error in Allocate Space Advanced Storage Attributes dialog box After you make changes to Allocated Space and click Advanced to access the Advanced Storage Attributes, the dialog box may contain the following error message: Stacked bar chart error: there must be at least one row and one numeric column, and data should be all positive or negative. This occurs if the system is attempting to display boundary storage size values. To correct the error: 1. Click Cancel on the Advanced Storage Attributes dialog box. 2. Change the allocated size slightly in the Allocate Space Wizard. 3. Click Advanced again. ML110 and DL100 systems do not support creating and growing storage space ASM does not support creating and growing RAID sets and logical drives on HP ProLiant ML110 and DL100 Storage Servers containing the Adaptec 2410 storage controller. These systems are shipped with the storage pre-configured. To work around this issue, delete the factory storage configuration and reconfigure all RAID sets and logical drives manually. Attaching disks with different capacities on a controller is not supported ASM does not support disks with different capacities attached to the same controller where they could be shared by the same RAID set or virtual array. To work around this issue, move disks of the same size to the same controller. Note: For systems with SmartArray 6404 controllers that act as two 2-port controllers, same sized disks need only be moved to their own 2-port pair to work correctly. HP ProLiant Storage Server iscsi Feature Pack Release Notes 11

Troubleshooting Tips ASM sets warning and critical thresholds for the directory quotas The warning threshold value that is entered for an application area corresponds to the WSS WebUI Directory Quotas warning and critical threshold values. ASM sets both the warning value and the critical value to the number entered in the ASM warning threshold field. To separate the warning and critical values, set the critical value in the WSS WebUI Directory Quotas page rather than setting it in ASM. Note: Only the warning value is displayed in the ASM user interface. Troubleshooting Tips ASM Errors All ASM-detected errors are logged to the Windows Event Manager. Examine the Event Manager contents while looking for additional error information by selecting Start > Programs > Administrative Tools > Event Viewer. 12 HP ProLiant Storage Server iscsi Feature Pack Release Notes