Field-testing procedure. LANmark-6

Similar documents
Field-testing procedure of. LANmark-6 10G. Cabling System. Technical Paper Nexans Cabling Solutions June Revision 1.4

LANmark-6 10G LANmark-6 A

Design Guidelines. LANmark-6A Cabling System. January 2015 Revision 2.0. Nexans LANmark-6A Design Guidelines Ver January Page 1

DATWYLER SYSTEM WARRANTY

Appendix 1 to the R&Mfreenet Warranty Program

Psiber Data WireXpert P R O F E S S I O N A L N E T W O R K T E S T I N G & P R O T O C O L A N A L Y S I S

LanTEK III FiberTEK III. Certifier for Copper and Fibre Cabling. Proof of Performance

LanTEK III FiberTEK III. Certifier for Copper and Fibre Cabling. Proof of Performance

SECTION TELECOMMUNICATIONS TESTING AND DOCUMENTATION

Qualified Partner Programme QPP. Cat.6 Channel Meassurement Issues Felice Guarna

The High Cost of a Low-Cost Cable Certification Tester

"IL CABLAGGIO IN RAME DI CATEGORIA 6 E LA CERTIFICA SUL CAMPO DEI PARAMETRI TRASMISSIVI FINO A 250 MHZ"

Remote Calibration. Connect the WireScope/FrameScope 350 and DualRemote 350 per either of the configurations below.

White paper. Field Testing of Direct Attach Modified Permanent Links. occfiber.com

Copper Certification Testing Best Practices Pocket Guide

Cable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment F Cable Certification

LANmark Snap-In Toolless connector. screened, with rear cover CAT7 GG45 INSTALLATION GUIDE

Certification for 10G copper cabling

The Impact of Internet of Things (IoT) on Cable Certification

The Impact of Internet of Things on Cable Certification

WireScope 155 SCOPE. Agilent Wirescope 155 Specs Provided by The Performance Leader in Hand-Held Network Tools

Open System Architecture Selecting the Right Cable and Connectivity for Your Application

Introduction. Standards

ANSI/TIA-568-C Cat 6A Field Test Specifications

CERTIFICATION PLUS SM

PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY

Chapter 3 Certifying Twisted Pair Cabling

Qualified Partner Programme QPP. Warranty Felice Guarna

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE

Technical Committee. Addendum to ATM Physical Medium Dependent Interface Specification for 155 Mb/s Over Twisted Pair Cable (af-phy-0015.

Training Offer. Catalogue

ANSI/TIA-568-C Cat 6 Field Test Specifications

DTX-PCU6S. Users Manual. Patch Cord Adapters

New standards that have led to higher speeds and new cable categories. Mike Gengler Sales Area VP, Asia/Pac & Japan Fluke Networks

TECHNICAL DATA SHEET Family code C2424SOLPCORD CAT 6 UTP Solid. version 1 LSNH PATCHCORD date page 1/5

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

Telegärtner Point of View

DTX-PCxxS. Users Manual. Patch Cord Test Adapters

Qualified Partner Programme QPP. Installation Practice Felice Guarna Wetzikon, July 2001

R&Mfreenet Advanced Cat 6A Shielded Connection Module

Performance specification for the Fluke DSP Fluke Corporation

Deviser Part No.: TC500-DL Deviser Instruments, Inc. All rights reserved.

INSTALLATION GUIDE. LANmark EVO Series Snap-in Connector UTP

Standards Update. by Paul Kish NORDX/CDT

Category 8 paves the way for IEEE 40GBASE-T. David Hughes RCDD/DCDC/NTS Senior Technical Manager MEA CommScope

2,5 and 5GBASE-T A Study of Development and Deployment. White Paper January 2017

An Introduction to Transmission Testing in the LAN Environment Copyright 2014, IDEAL Networks

DTX Series. Fluke Networks DTX-1200 Specs Provided by Users Manual. CableAnalyzer

LANmark-7A H i g H - S p e e d C O p p e R S O l u t i O n F O R 4 0 g i g a b i t a p p l i C a t i O n S

Advanced Test Equipment Rentals ATEC (2832) OMNIScanner TM. featuring OMNIFiber TM

Power Over Ethernet with Panduit Copper Cabling. How To Create More Meaningful Connections With The Highest Performing Infrastructure

Test Report modcon - PS88A6M

USB 2.0 LR 4-Port Extender

Contents. Structured Cabling Solutions. LAN Cables Patch Cords Connectors Patch Panels... 06

Ethernet Media. Technical Data. Cable Spools 2. Cordsets & Patchcords 5. Patchcords & Field Attachables 12

ANSI/TIA/EIA-568-B Cabling Standard

FREQUENTLY ASKED QUESTIONS (FAQs)

Cat 6 (500 MHz) UTP solid cable (PVC sheath)

White Paper: Audio / Video (AV) Cabling Considerations

The advantages of the 6-connector channel

JUN 2016 Rev B

DTX Series. Users Manual. CableAnalyzer

Passive Infrastructure Technical Specification. Version 1 / March 14

LANmark-6A H I G H - S P E E D C O P P E R S O L U T I O N F O R 1 0 G I G A B I T A P P L I C A T I O N S

The AMP NETCONNECT Category 6 Cabling System

DTX CableAnalyzerTM Accessories Guide

25-Year System Warranty. Terms and Conditions. NetworkSciences

The six major components of a structured wiring system are:

UTP Cat 5e cable (200 MHz) (PVC sheath)

LANmark-7A HIGH-SPEED COPPER SOLUTION FOR 40 GIGABIT APPLICATIONS

ANSI/TIA/EIA-568-B Cabling Standard

/June/2014 Rev C

Engraved Labelling Service

NGBASE-T Cabling Requirements

The module for the highest standards, guarantees the best performance in the 10 Gigabit Ethernet cabling.

PANGEN SYSTEM WARRANTY. Warranty Guide

E-DAT C6A. The compact connection system of course with Cat.6A

AMP-TWIST* 6S Series SL Jack

HOW DO I KNOW IF THE CABLING FIRM I AM TALKING WITH IS REALLY QUALIFIED? Wire is Wire Q & A. Cabling is an Investment. Ask the Right Questions

Voice Integration Overview

QuickLAN 6050 & Easy instrument for a preliminary LAN test

Product information 19" 3U Global Patch Panel 48xRJ45/u, Cat. 6, partly populated R302361

Changes or modifications not expressly approved by InFocus Corporation may void authority to operate the equipment.

USB Raven Port USB 3.1, 100m CAT 6a/7 Point-to-Point Extender System User Guide

IBDN 110 Cross-Connect System

UNIVERSITY OF CALICUT (Purchase Division)

[0.057] 5.8 [0.23]

Cat.8 Shielded Field Termination Plug Description

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

KRAMER ELECTRONICS LTD. USER MANUAL MODELS: WP-110, XGA Line Transmitter. PT-120, XGA Line Receiver. TP-120, XGA Line Receiver. P/N: Rev 1

STRUCTURED CABLING WORKS SCHEDULE 1: GROUND FLOOR ITEM DESCRIPTION QTY UNIT RATE KSH

Ethernet Media. Technical Data. Cable Spools 2. Cordsets & Patchcords 5. Patchcords & Field Attachables 10

5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800. User's Manual

SIMPLY PRECISE USER MANUAL. ADJUSTMENT TOOL For NUMERIK JENA Encoders with Online Compensation

LANmark-6A. High-speed Copper Solution For 10 Gigabit Applications

The Quality Connection. LEONI QuickLine Class E Cabling Solution

GST Connectivity Solutions

LANmark-6A. High-speed Copper Solution For 10 Gigabit Applications

CAT5-1600A Extender. EXT-CAT5-1600A User Manual.

PIONEERS OF The Structured Cabling Systems

Transcription:

Field-testing procedure LANmark-6 Technical Paper Nexans Cabling Solutions September 2006

Table of Contents 1 Introduction 3 2 How to proceed? 4 2.1 Introduction 4 2.2 Permanent link testing vs. Channel testing 4 2.3 Category 6 and connecting hardware interoperability 5 2.3.1 How to recognize a LANmark network from the old standard to the new standard 5 2.4 Installation models 6 2.4.1 2 connectors : Interconnect - TO 6 2.4.2 3 connectors : Cross connect - TO 7 2.4.3 3 connectors : Interconnect - CP - TO 8 2.4.4 4 connectors : Cross connect - CP - TO 9 2.4.5 Summary 10 3 What equipment is available to test for compliance? 11 3.1 Level III testers 11 3.2 Care of the Tester and leads 11 3.3 Before you go to site 12 4 How to configure the tester? 13 4.1 Fluke DSP 4X00 and DTX series 13 4.2 Fluke Omniscanner 2 14 4.3 Agilent Wirescope 350 14 4.4 Ideal LANtek-6 & 7 (G) 14 4.5 Summary 15 4.6 Testing a network conform the category 6 mated component requirements of ISO/IEC 11801 from before 2003 16 4.6.1 Fluke DSP 4X00 and DTX series 16 4.6.2 Fluke Omniscanner 2 16 4.6.3 Agilent Wirescope 350 17 4.6.4 Ideal LT8600 series 17 4.6.5 Summary 17 4.7 Selecting the right cable type 18 5 Understanding the test results 19 Field Testing Procedure LANmark-6 2 September-2006

1 Introduction The testing of Class E (Category 6) solutions is a longer and more involved process than for Class D (Category 5e). The purpose of testing is to validate the installation against both the requirements of the standards and the demands of the Nexans warranty process. This document serves to qualify the current testing requirements for LANmark 6 solutions against the ISO/IEC 11801 : 2002. If testing throws up errors or failures in the results the information gathered should be used to identify the source of the problem so that the installer can rectify and re-test. To pass testing for the Nexans warranty all Permanent Links and/or Channels in an installation should be tested, and all should pass. You should agree with the client before starting the contract how to deal with marginal pass results, as they may not be aware that a marginal result may be because of the accuracy and tolerances of the tester. Field Testing Procedure LANmark-6 3 September-2006

2 How to proceed? 2.1 Introduction This procedure is meant as a support tool for field-testing copper cabling networks. The definitions in the standard ISO/IEC 11801 : 2002 are applied into practical recommendations. After describing some general definitions, the second half of this chapter is especially focused on measuring category 6/Class E networks. The procedure is to be followed in case of applying for Nexans Certified Systems Warranty. 2.2 Permanent link testing vs. Channel testing In the ISO standards two different ways of testing are described. A permanent link is the fixed part of the cabling, which is tested after installation, these testresults give information on installation quality. The permanent link extends from the patch panel in the cabinet to the telecommunications outlet at the user side. It excludes work area cords, equipment cords and crossconnections, but does include the optional consolidation point. Permanent link Active Equipment PC Channel Figure 1: Model of Permanent Link and Channel testing Field Testing Procedure LANmark-6 4 September-2006

A channel represents the complete end-to-end path between the user equipment (PC, phone, video, printer, ) and the active equipment at the cabinet side (switch, hub, PABX, video equipment). The channel includes the work area cord, the equipment cord, and the cross-connection. Both permanent link and channel can be measured with the current commercially available field testers. In the next paragraphs following issues are covered: How the several installation models of Class E/category 6 networks can be tested? and Which specific models of test-equipment and test heads can be used. 2.3 Category 6 and connecting hardware interoperability The Category 6 test method is being specified in the American TIA/EIA-568-B.2-1 and the international IEC 60603-7-4 (unscreened) and IEC 60603-7-5 (screened) standards, of which the TIA standard has been ratified. In the category 6 networks prior to end 2002 manufacturer's plugs and jacks are not necessarily matching in NEXT and return loss performance. While they mate properly and pass wire map, you often do not get Category 6 component performance unless you use a plug and jack from the same manufacturer. Even more important is that the connection of field test equipment should be made with vendor dedicated category 6 test heads! With the arrival of the full ratified and published standard this all now is specified by the so-called deembedded test plug values. See for more background information in Nexans White paper Deembedded, impact on Category 6 offering. This change has its implications on field testing. In the following paragraphs the implication in regards to the Nexans offering is described. Before you go to the test site, please make sure to prepare your tester in accordance to the right standard. 2.3.1 How to recognize a LANmark network installation from the old standard to the new standard Nexans has brought its product set in line with the standard. The jacks are distinguished from the legacy by a relief (raised) of the description of LANmark6 on the jack. On the legacy ones the logo of LANmark6 is impressed. Field Testing Procedure LANmark-6 5 September-2006

2.4 Installation models 2.4.1 2 connector model : Interconnect - TO Figure 2.1 : Testing a permanent link in a 2 connector model Figure 2.1 shows the two-connector model as described in the standard. In this installation model both Permanent Link testing and Channel testing methods can be applied. In case of Permanent Link testing, make sure the right test heads are used (see also chapter 4). In case of Channel testing make sure only Nexans LANmark6 Ultim patch cords are used. When submitting the test results for the Nexans Certified System Warranty, the guarantee and warranty will be based on a 2 connector system model. Field Testing Procedure LANmark-6 6 September-2006

2.4.2 3 connector model : Cross connect - TO Option 1 a. If the installation is done with pre-terminated single ended LANmark6 Ultim patch cords of Nexans to connect the active equipment AND b. If LANmark6 patch cords of Nexans are used to cross connect the patch panels, Testing as a 2-connector test model, described in 2.4.1, will do to acquire a Nexans Certified Systems Warranty on the complete installation (= 3 connector installation). Option 2 If the single ended patch cord is manually terminated on the patch panel, then the full channel has to be measured, as shown in figure 2.2. Only Channel testing will do when Nexans LANmark6 Ultim patch cords are used. When one of these options is chosen the Certified Systems Warranty on the 3 connector model system can be obtained, when the test results are submitted together with the filled in Nexans Warranty application form and other required documents are included. Figure 2.2 : Testing at 3 connector Cross connect - TO model (only Channel Testing allowed) Note: An alternative way of testing is to test as a 2-connector installation ignoring the conditions mentioned in option 1 of this paragraph, see Figure 2.1. (With these test results only a Certified Systems Warranty on the 2 connector installation can be obtained.) Field Testing Procedure LANmark-6 7 September-2006

2.4.3 3 connector model : Interconnect - CP - TO In this model of installation three (3) options of testing are possible: Option 1 The installation is done with pre-terminated single ended LANmark6 Ultim patch cords of Nexans to connect the Consolidation Point (CP) with the Terminal Outlet (TO) Testing in a 2 connector test model as described in 2.4.1 will do to acquire a Certified Systems Warranty on the complete installation (= 3 connector installation). Option 2 If the single ended patch cord is manually terminated on the Terminal Outlet (TO), then the full installation has to be measured. See Figure 2.3. Permanent Link testing will do, under the condition that the right test heads are in use. Option 3 If the single ended patch cord is to be manually terminated on the Terminal Outlet (TO), then as an alternative to option 2 also Channel testing will do, under the condition that only Nexans LANmark6 Ultim patch cords are used When one of these options is chosen the Cerified Systems Warranty on the 3 connector system model can be obtained, when the test results are submitted together with the filled in Nexans Warranty application form and other required documents are included. Figure 2.3 : Testing at 3 connector Interconnect - CP - TO model Note: An alternative way of testing is to test as a 2-connector installation from the Patch Panel to the Consolidation Point (CP) ignoring the conditions mentioned in option 1 of this paragraph. (With these test results only a Certified Systems Warranty on the 2 connector installation can be obtained.) Field Testing Procedure Copper 8 September-2006

2.4.4 4 connector : Interconnect - Cross connect - CP - TO Important: In a 4 connector model a maximum of 2 connectors at each side should be respected as mentioned in the standard. In this model of installation Nexans recommend two options of testing: Option 1 a. The installation is done with pre-terminated single ended LANmark6 Ultim patch cords of Nexans to connect the active equipment and to connect the Consolidation Point (CP) with the Terminal Outlet (TO) and b. LANmark6 patch cords of Nexans are used to cross connect the patch panels Then testing in a 2 connector test model as described in 2.4.1 will do to acquire a Nexans Certified Systems Warranty on the complete installation (= 4 connector installation). Option 2 The single ended patch cords are manually terminated on the patch panel and on the Terminal Outlet (TO) Then the full channel has to be measured, see figure 2.4. Only Channel testing will do, under the same conditions as described in the previous paragraphs. When one of these options is chosen the Certified Systems Warranty on the 4 connector system model can be obtained, when the test results are submitted together with the filled in Nexans Warranty application form and other required documents are included. Figure 2.4: Testing at 4 connector Interconnect - Cross connect CP TO model (only Channel Testing possible) Note: An alternative way of testing is to test as a 2-connector installation from the Patch Panel to the Consolidation Point (CP) ignoring the conditions mentioned in option 1 of this paragraph. (With these test results only a Certified Systems Warranty on the 2 connector installation can be obtained.) Field Testing Procedure LANmark-6 9 September-2006

2.4.5 Summary 2 connectors : 3 connectors : 3 connectors : 4 connectors : Interconnect - TO Cross connect - TO Interconnect - CP - TO Interconnect - Cross connect - CP - TO Class E CM/PL CM CM/PL CM CM= Channel Measurement PL= Permanent Link Measurement Field Testing Procedure LANmark-6 10 September-2006

3 What equipment is available to test for compliance? 3.1 Level III testers Nexans strongly recommends the use of equipment with baseline accuracy that exceeds TIA level III, as indicated by independent laboratory testing. Test equipment must be capable of certifying Class D and Class E links. Nexans have endorsed a number of testers and configurations for use in validating the LANmark 6 solution against the Warranty and performance requirements on installations. The list includes: 1. Fluke DSP 4X00 and DTX series 2. Fluke (Microtest) Omniscanner 2 3. HP Agilent Wirescope 350 4. Ideal (Wavetek) LT-8600 series 5. Ideal Industries Lantek-6 and 7(G) 3.2 Care of the Tester and leads The tester is an accurate piece of equipment and as such needs to be looked after. Please follow manufacturer recommendations for the care and maintenance of your tester. Have your tester calibrated at least once a year by the tester manufacturer. The test leads are susceptible to wear and damage. Please follow manufacturer recommendations for the care and maintenance of your test leads and do not fold or exceed the bend radius of the test cables. Do not allow the weight of the tester to be supported by the test lead. Always put your tester on charge the day before it will be needed and then place it on charge overnight during the testing phase of the project. Cat 5e Cat 6 Cat 6 DE Fluke DSP 4X00 and DTX series x x x Fluke (Microtest) Omniscanner 2 x x x HP Agilent Wirescope 350 x x x Ideal (Wavetek)8600 series x x x Ideal Industries Lantek-6 and 7(G) x x x Field Testing Procedure LANmark-6 11 September-2006

3.3 Before you go to site The firmware update and the version of the software database on the tester are important. The firmware from the tester manufacturer provides the tester with the correct parameters to test and how to interact with the test head. The software database holds the test parameters and limits for the standards that you will be comparing the cabling installation against. For all testers ensure you have the latest version of the tester firmware loaded, this can be obtained from the manufacturer of the test equipment Internet site along with the latest software and database which should also be loaded into the tester. You must calibrate the tester local and remote ends to each other before you go to site. If you are using some testers you will also need to have the test leads calibrated onto the tester units. This will improve the accuracy of the tester. Make sure you have the latest version of the upload and diagnostic software on your PC on to which you will download the test results from the tester (available on Internet sites of the manufacturers). Always download each day s worth of test results at the end of the day onto your PC. Always put your tester on charge the day before it will be needed and then place it on charge overnight during the testing phase of the project. Field Testing Procedure LANmark-6 12 September-2006

4 How to configure the tester? 4.1 Fluke DSP 4x00 and DTX series DSP-LIA101S or DTX-PLA001 A method for testing LANmark 6 is to use the Permanent Link Adapter with a swappable Personality Module PM06 or PM25. The PM06 can be used in both UTP, FTP and STP environment. Also the PM25 can be used only in a UTP environment. The limits to be used in this configuration are the ISO/IEC 11801 Class E PL standard database limits for the Permanent Link. General Testing Tips : Use the straps to hang up the tester. This leaves one hand free to press buttons and one hand to support the weight of the PL cable. Only screw finger tight the screw attaching PM module to PL lead. Do not use screwdriver. Look for any damage caused by overtightning. Failure to adequately support the weight of the PL cable or test lead may result in excessive load being applied to the RJ 45 jack or misalignment of the plug and jack during the test process. The consequences of this action may result in poor readings damage to the test lead or outlet and may invalidate Nexans product warranty. Use the OMNI Field Cal tool (5 finger tool which looks like a set of PM s without the plugs) to set the PL leads into the tester before you start testing. Field Testing Procedure LANmark-6 13 September-2006

4.2 Fluke Omniscanner 2 OMNI- Universal Link Adapter A method for testing LANmark 6 is to use the Omniscanner Universal Link Adapter with a Personality Module PM06 or PM25. The PM06 can be used in both UTP, FTP and STP environment. PM25 is only meant to be used in a UTP environment. The limits to be used in this configuration are the ISO/IEC 11801 Class E PL standard database limits for the Permanent Link. General Testing Tips : Use the straps to hang up the tester. This leaves one hand free to press buttons and one hand to support the weight of the PL cable. Only screw finger tight the screw attaching PM module to PL lead. Do not use screwdriver. Look for any damage caused by overtightning. Failure to adequately support the weight of the PL cable or test lead may result in excessive load being applied to the RJ 45 jack or misalignment of the plug and jack during the test process. The consequences of this action may result in poor readings damage to the test lead or outlet and may invalidate Nexans product warranty. 4.3 Agilent Wirescope 350 The configuration accepted by Nexans for the Agilent Wirescope 350 tester uses a test head Universal Link Test Probe (N2604A-10x) with a patchcord type test lead. This product set is subject to wear in the test cord, which should be monitored closely and looked after during its life. Eventually errors and miss readings will occur as the lead wears. The limits to use with this configuration are the limits for ISO Class E and can be found on the Agilent website. 4.4 Ideal LANtek-6 & 7(G) The configuration accepted by Nexans for the Lantek 6 & 7(G) testers uses a Basic Link test head with a patch cord type test lead. This product set is subject to wear in the test cord, which should be monitored closely and looked after during its life. Field Testing Procedure LAnmark-6 14 September-2006

4.5 Summary Fluke Agilent Technologies Ideal Industries Website www.flukenetworks.com/ www.wirescope.com www.idealindustries.com Field Tester DSP-4300 Digital OMNIScanner 2 WireScope 350 LANTEK-6 & 7 Characteristics Support for Cat.6 Universal Adapters Vendor specific Basic Channel Adapter and Permanent Link and Vendorspecific Link adapters 2 Patchcords and through Basic Link Calibration procedure adapters Support for Cat.6 Channel Adapter Channel Adapter Smartprobe with ACT Channel Adapter Channel through with Remote with Adaptive Vector Software Connector Cancellation (AVC) Compensation Technology (RCC) Technology On site No (partially for LIA101) No Yes Calibration Cat.6 Channel Test Adapters Product Name Cat.6 Channel Omniscanner Agilent Smartprobe LANTEK Cat.6 adapter for Category 6 Cat6 Channel Channel Adapter DSP4x00, RJ45 Channel Adapter RJ45 Order Code DSP-LIA012S 8262-02 N2604A-100 0012-00-0627 DSP-4x00 software Test head compatible with version 4.00 All Version 3.00 All software and later Testsetup to be ISO Class E Class E Channel-4/01 ISO Class E Channel ISO Class E Channel used (LIMITS) Channel Test patchcords User patchcord User patchcord User patchcord User patchcord N101.225 N101.225 N101.225 N101.225 series Universal Permanent DSP-LIA101 OMNI-LIA101S N2604A-101 Cat.6 Channel Adapter Link Cat.6 (uses Sentinel plug) Adapter N2604A-10x Name of Personality PM06, PM25 PM06, PM25 NA User patchcord Module (N121.225 series) or Pair Cat6 RJ45-to-Cat6 RJ45 Permanent Link Reference Patchcords (preloaded) 2m*2 LIMIT Setup NA to be tested ISO Class E Link ISO Class E Link ISO Class E Link ISO Class E Link Field Testing Procedure LANmark-6 15 September-2006

4.6 Testing a network conform the category 6 mated component requirements of ISO/IEC 11801 from before 2003 If you have to measure on networks that are made conform the category 6 mated component requirements of ISO/IEC 11801 from before end 2002, be aware that some electrical properties of other manufacturer plugs and patch cords are not compatible with the LANmark 6 products. Therefore to avoid any issues of interoperability and errors or low pass margins caused through use of incompatible products Nexans have defined, with the tester manufactures, the correct test heads, plugs, leads and database to test the LANmark 6 solution. This will provide the installer and end user with repeatable and reliable results to demonstrate the compliance of the LANmark 6 solution with the ISO 11801 standards. 4.6.1 Fluke DSP 4x00 and DTX series There is one configuration accepted by Nexans for the Fluke DSP 4x00 and DTX series testers: DSP-LIA101S A method for testing LANmark 6 is to use the Permanent Link Adapter with a swappable Personality Module PM06. The limits to be used in this configuration are the ISO 11801 Class E PL standard database limits for the Permanent Link. DTX- PLA001 A method for testing LANmark 6 is to use the Permanent Link Adapter with a swappable Personality Module PM06. The limits to be used in this configuration are the ISO 11801 Class E PL standard database limits for the Permanent Link. 4.6.2 Fluke Omniscanner 2 OMNI- Universal Link Adapter The only method for testing LANmark 6 is to use the Omniscanner Universal Link Adapter with a Personality Module PM06. The limits to be used in this configuration are the ISO 11801 Class E PL standard database limits for the Permanent Link. Field Testing Procedure LANmark-6 16 September-2006

4.6.3 Agilent Wirescope 350 The configuration accepted by Nexans for the Agilent Wirescope 350 tester uses a test head Universal Link Test Probe (N2604A-003) with a patch cord type test lead. This product set is subject to wear in the test cord, which should be monitored closely and looked after during its life. Eventually errors and miss readings will occur as the lead wears. The limits to use with this configuration are the limits for ISO Class E and can be found on the Agilent website. 4.6.4 Ideal LT6800 series The configuration accepted by Nexans for the Wavetek 8600 and 8601 testers uses a test head with a patch cord type test lead. This product set is subject to wear in the test cord, which should be monitored closely and looked after during its life. Eventually errors and miss readings will occur as the lead wears. The limits to use with this configuration are the ISO limits for ISO Class E and can be found on the Ideal Internet web site. 4.6.5 Summary Cat6 Adapter Reference Code Limits Fluke DSP 4x00 series Permanent Link DSP-LIA101 ISO Adapter + PM06 Permanent Personality Module Link Class E Fluke DTX series Permanent Link DTX-PLA001 ISO Adapter + PM06 Permanent Link Class E Fluke (Microtest) Permanent Link 8262-38 ISO Omniscanner 2 Adapter Omniscanner Permanent Cat6 + PM06 Link Class E Personality Module Agilent Wirescope 350 Universal Smartprobe N2604A-10x ISO Class-E-adapter Permanent Link Class E Ideal Lantek 6 and 7(G) Class E Link Test ISO Probe Permanent Link Class E Ideal LT 8600 series Nexans Class ISO E/Cat6 Adapter Permanent Link Class E Table 1: Recommended testheads & limits for testing conform the category 6 mated component requirements of ISO/IEC 11801 Field Testing Procedure LANmark-6 17 September-2006

4.7 Selecting the right cable type When setting up your tester you should pay attention to the tester set up and the NVP (Nominal Velocity of Propagation) for the cable under test. This setting will determine the length and skew parameters and will therefore affect the results obtained. Some testers set themselves to pre-set or default settings each time they are switched on. You therefore must check this and configure the tester according to the cable data sheet for the product you are testing. Generally for Nexans cabling systems, the values to be used are: Commercial cable name NVP Nexans LANmark-5 UTP 0.69 Nexans LANmark-5 F 2 TP F 1 TP 0.69 Nexans LANmark-6 UTP 0.69 Nexans LANmark-6 F 2 TP F 1 TP 0.69 Nexans LANmark-6 S-FTP 0.69 Nexans STP 0.79 Field Testing Procedure LANmark-6 18 September-2006

5 Understanding the test results 5.1 What the test results show One can only hope that first time of testing a link the results will show a pass with headroom. However the first thing most testers will show is a wire map failure. As there is an insertion life on tester heads and leads a number of installers make use of a more basic test tool which just checks for wire mapping before running with a full set of tests for Cat 6. This releases the tester for use elsewhere and saves on head wear. If a failure is detected then make use of the tester diagnostics to locate the problem. Some of the later testers come with analysis software and tools that will locate the problem to a point along the length of the cable or at the termination. The treatment of marginal asterisked (*) results should be clarified with the client in advance. Due to the known experience of tester inaccuracies due to test head variations it is our experience that results are usually on the pessimistic side. Nexans will therefore consider a *PASS as acceptable within the warranty. A *FAIL however should be investigated and is not acceptable. 5.2 What to do with the result - Certification When submitting results for the Nexans Warranty, a Nexans Warranty application form for the site has to be filled in and submitted to your local Nexans unit. This warranty application form can be obtained form your local Nexans contact. Upload and Save Which format? DSP-4x00 & DTX: *.flw Omniscanner: *.flw Wirescope: *.mdb Ideal: *.zip(database) It is preferable to save the test results with plots if they are available on your tester as re-certification of graphical test result is only possible if plots are saved. Field Testing Procedure LANmark-6 19 September-2006

Global expert in cables and cabling systems Paris rue Mozart, 4-10 92587 Clichy CEDEX France Tel +33 (0)1 56 69 84 00 Fax +33 (0)1 56 69 86 38 Brussels Alsembergsesteenweg 2, b3 1501 Buizingen Belgium Tel +32 (0)2 363 38 00 Fax +32 (0)2 365 09 99 Orpington Swan House - New Mill Road Crayfields Business Park Orpington - Kent - BR5 3QD - UK Tel +44 (0) 1689 887654 Fax +44 (0) 1689 887650