UPS5000-E (25-75 kva) Series

Similar documents
Modular Uninterruptible Power System

Huawei Energy Powering the Future. Huawei UPS Solutions. Huawei Energy Powering the Future HUAWEI TECHNOLOGIES CO., LTD.

Trademark Notice. General Disclaimer.

UPS5000-E ( kva) Series

Trademark Notice. General Disclaimer.

Trademark Notice. General Disclaimer.

HUAWEI TECHNOLOGIES CO., LTD. Huawei UPS5000-A Series kVA Uninterruptible Power Systems

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

MP7. Uninterruptible Power Supply

Rectifier Module R4815N1. Introduction. Feature Features High efficiency: >94% Output feature. Efficiency curve

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

LEVELUPS T3 3 UPS. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability with Embedded Isolation Transformer

Huawei FusionHome Smart Energy Solution

MUST900 Modular UPS. Datacenter & servers. Internet centers. Local Area Networks (LAN) Telecommunication devices. Emergency application

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output

THOR Modular. Modular UPS system. Online double-conversion Scalable Decentralized Parallel. Modular. 10, 20, 30, 40kVA modules kVA systems

LEVELUPS T3. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability and Robust Protection for Industrial Loads

the Centric 300 An advanced modular UPS up to 1800kVA/kW

HUAWEI TECHNOLOGIES CO., LTD. HUAWEI FusionServer X6000 High-Density Server

SMARTONLINE E3 UPS SYSTEMS

Huawei Embedded Power System

HUAWEI TECHNOLOGIES CO., LTD. Huawei IDS2000-S Small Modular Data Center Solution

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva

Schneider Electric Easy UPS 3S

GAMATRONIC, A SolarEdge Division.

APMTM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology

HUAWEI Tecal X8000 High-Density Rack Server

Galaxy VM. Three-phase power protection. Galaxy VM trusted partner for your business continuity

Business continuity made easy

Distributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Galaxy VM. 160/200 kva Parallel capable up to 800 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology

Trademark Notice. General Disclaimer.

Galaxy VX. From 500 to 1500 kw N+1 Parallel solutions up to 4000 kw 380V / 400V / 415V / 440V. schneider-electric.com/ups

Socomec Netys PR RT U P S TOWER / RACK MOUNT

Tel: AC Power for Business-Critical Continuity TM

Eaton 9EHD Industrial UPS

Kohler EW 6000TX. Transformer-based. (UPS kVA)

Actual4Test. Actual4test - actual test exam dumps-pass for IT exams

SLI 15 INVERTER SERIES, 1500 W

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

POWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA)

ELEKTRA SMALL FOOT PRINT SERIES. Mission Critical & I.T Grade UPS I.T GRADE ONLINE DOUBLE CONVERSION UPS 10KVA ~ 200KVA (3/3)

24/48V Battery Bank Ah High Cycling Long Life

SmartOnline 277/480V 3-Phase Wye 80kVA Modular 3-Phase UPS System, On-line Double- Conversion UPS for North America

SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules

SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

The Power of Modularity

Modular, scalable, high-efficiency power protection for data centers

MGE Galaxy /900 kva

SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America

SmartOnline SV Series 40kVA Medium-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, 2 Battery Modules

RT12-240V/2.4kW Rectifier Specification

SmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

Smarter Energy for a Better Life. Huawei FusionHome Smart Energy Solution. For Homeowners

HP Rackmountable 3 Phase Uninterruptible Power Systems Overview

Symmetra PX 48kW. Scalable from 16 to 48kW. Make the most of your energy TM. Modular, Scalable, High-Efficiency Power Protection for Data Centers

MUST 900 UPS. Finally the benefits of Modular ups are for all. 3 Phase Modular. Hot swappable, scalable 30kVA to 900kVA

Schneider Electric Easy UPS 3S

AIS 3000 APC AIS kVA 400V w/3 Batt. Modules Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

About Huawei. A Global Leader of ICT Solutions

Modular, scalable, high-efficiency power protection for data centers

MGE Galaxy /50/60/80/100/130 kva. The recommended power protection for all critical applications

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

DSP Control. 0.9 Output Power Factor. Wide Input Range. High Efficiency Mode(ECO) Frequency Converter Mode. Input THDi<5% Output THDv<2%

APMTM UPS 18kW - 90kW The Flexpower Technology for mission critical applications

S-series Mass Connection Solutions

Power Solutions Catalogue

Liebert NXr Series 30kVA to 160kVA. AC Power for Business-Critical Continuity TM

SmartPro 230V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

AP 160 N. UPS COMPACT Rack tower convertible 1-10 kva. online LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS

EP Series II UPS 230 V

MGE Galaxy /30/40/60/80/100/120 kva. The recommended power protection for all critical applications.

Smart Energy Center. Simple & Easy. Higher Revenue. Battery Ready. Safe & Reliable

EA660 Modular UPS Introduction 1/35

RT4F-110V/25A RECTIFIER

SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial

Eaton 93E UPS Simple power management for every IT environment.

SmartOnline V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Bypass Switch

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial

SCALABLE, FAULT TOLERANT, INDUSTRIAL PROTECTION. SOLAHD S5KC UNINTERRUPTIBLE POWER SUPPLIES, 5 20 kva

ALL PRODUCTS UNINTERRUPTIBLE POWER SYSTEMS

Huawei KunLun Mission Critical Server. KunLun 9008/9016/9032 Technical Specifications

Data Sheet FUJITSU Server PRIMERGY CX400 M4 Scale out Server

Huawei KunLun Mission Critical Server. KunLun 9008/9016/9032 Technical Specifications

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

UPS Sentry MPS. SENTRY MPS is also compatible with different battery technologies: openvase lead acid and AGM and Gel VRLA, NiCd.

SmartOnline V 3kVA 2.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

SmartOnline Hot-Swappable Modular UPS System On-line, double-conversion protection for mission critical applications

TME Modular Series UPS System kva/kw - 208/220 VAC

Symmetra PX. Symmetra PX 48kW Scalable from 16kW to 48kW. Modular, Scalable, High-Efficiency Power Protection for Data Centers

Product catalogue. going for the highest level in sustainability! -Syncro+ -Office Protection Station

EA300. EA300 series 500 ~ 1500VA

SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA)

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

Transcription:

Battery Integrated Uninterruptible Power System UPS5000-E (25-75 kva) Series HUAWEI TECHNOLOGIES CO., LTD.

CONTENTS 02 Solution Overview 03 Customer Benefits 09 System Architecture and Key Components 12 Typical Configuration 13 System Parameters 14 Global Services

Solution Overview UPS5000-E Battery Integrated Solution Rated capacity: 25-75 kva The three-phase uninterruptible power supply solution is applicable to small- and medium-sized data centers or high-density areas. The integrated UPS adopts online double conversion design and power modules with a leading efficiency of 96.5%. The UPS is fully modular with hot-swappable modules. Redundancy is also supported. UPS5000-E-75K-BF UPS and batteries integrated in one cabinet Modular and redundant Efficient double conversion technology, module efficiency 96.5% High power density design 1.0 output power factor (kva = kw) Front maintenance, can be installed against a wall Battery module hot-swappable Battery module fault displayed locally 02

Customer Benefits: Simple Efficient Reliable 01 All Modular Design Simple installation: Site survey and battery wiring are not required. Professional installation, complex wiring, long labor hours Huawei battery integrated UPS Traditional battery rack solution The power module, bypass module, battery module, and control module all use modular and integrated design. Compared with traditional UPS and battery rack solutions, the integrated UPS is installed by inserting modules onsite and does not require site survey or wiring. A common engineer can finish installation and wiring, greatly reducing labor hours for site installation and wiring. 02 Battery Modular Pre-integration Batteries pre-integrated before delivery Hot-swappable terminals Wiring not required onsite 03

03 Simple Maintenance Power module Battery module Bypass module Control module The power module, battery module, bypass module, and control module are all hot-swappable. Online maintenance is supported. A common engineer can finish replacement and maintenance in 5 minutes. 04 Intelligent Battery Management Without Manual Inspection Battery module overtemperature alarm Fuse blown for protection if battery module is abnormal Fault displayed locally, easy to locate the faulty module Intelligent equalized charging, float charging, and temperature compensation Battery hibernation can be enabled, preventing battery lifespan from being shortened due to long-time float charging 04

Customer Benefits: Simple Efficient Reliable 01 Space Saving >> Power Module: High Power Density 25 kva power module The power density increases exponentially Structure patent design Heat sink design Occupying 2 U space, improve space use by 50% compared with the industry >> Highly Integrated, Saving Footprint Traditional UPS Battery rack Battery integrated UPS Huawei battery integrated solution saves 50% footprint compared with a traditional solution. 05

02 Efficient and Energy-saving >> >> High efficiency at low load rate Due to redundancy configuration to ensure reliability and excessive configuration at the initial stage to meet the power demand in 3-5 years, the UPS system of traditional datacenter often operates at load rate of 10%-40% and the operating efficiency is far below the value claimed. It's estimated that the UPS loss takes up 6%-10% of the total power consumption in datacenter Huawei UPS can keep high efficiency operation at low load rate: 96% at 40% rated load and 95% at 20% rated load Efficiency 100% 95% 90% 85% 80% 75% 70% 65% 60% 55% 50% 0% 20% 40% 60% 80% 100% Load rate >> Intelligent hibernation design When the load rate is very low (below 10%-15%), intelligent hibernation can be enabled and some power modules will switch to "standby" state to boost load rate and improve operating efficiency To ensure reliability, at least one power module serves as redundancy module and when load increases dramatically, the sleep module will be awaked instantly 100% 75% 50% 25% 0% Load Module Module Module Module Module Module Module Module 06

Customer Benefits: Simple Efficient Reliable 01 Redundancy Design, Eliminating Single Point of Failure Redundancy design for energy control unit, communication buses to eliminate single point of failure Fault-tolerant design for fan system: 30% load can be driven when 2 fans fail and 50% load when 1 fan fails Redundant Energy Control Units Control module CAN2 Control module CAN2 CAN1 CAN1 Dual communication system design, single bus system failure, will not affect the normal operation of the system. Power module Power module Power module 3 power module running 2 power module running Power module redundancy design, a single power module failure, will not affect the normal operation of the system. 20% Load rate 20% Load rate 30% Load rate 20% Load rate 30% Load rate Fan fault tolerance design, Single fan faults with load 50%,two fan faults with load 30% 07

02 Strong Adaptability in Power Grid, Load & Environment High grid adaptability 138-485 Vac wide input voltage range to minimize battery use: 485-305Vac for 100% load; 305-138 Vac for 100%-40% load (derating linearly) 6 kv/5 ka lightning protection design, reducing lightning-related failure rate Areas allowing load rate >50% Huawei UPS Input Voltage Range Typical UPS Input Voltage Range 100 150 200 250 300 350 400 450 500 Input Voltage Range (V) High load adaptability High output power factor of up to 1, 25% more load driven than traditional UPSs The application of PFC technology in modern IT devices like servers, storages, routers improves the input power factor to more than 0.95. And if they are powered by UPS with output power factor of 0.7-0.8, the investment on UPS will increase remarkably No derating for capacitive or inductive devices with a PF>0.5 PF=0.9 (leading) PF=0.7 (leading) PF=0.5 (leading) Ideal Active power (P) PF=1 φ PF=0.9 (leading) PF=0.7 (leading) PF=0.5 (leading) Huawei UPS Reactive power (Q) High environment adaptability No derating at 40 to ensure power continuity Conformal coating on PCB, improving adaptability to dusty or salty spray environment System normal operation After Airborne Hygroscopic Dust Test 08

System Architecture and Key Components 01 System Architecture and Composition 1 2 25 kva power module Static bypass module 1 6 3 4 Monitoring module Battery module 3 2 10 5 Battery switch 6 LCD 4 7 8 Air filter Maintenance bypass switch 9 8 5 9 Input switch 7 10 Monitoring unit (SNMP and RS485 communications in standard configuration) Dimensions: 600 mm x 1200 mm x 2000 mm 09

02 Key Components Power module The Power module with rated capacity of 25 kva/kw can eliminate all the nine common problems in public grid and output pure and stable sine wave. Dimensions (H x W x D): 86 mm x 442 mm x 620 mm Bypass module The bypass module can provide continuous power supply to load when overload. The bypass module of UPS5000-E features concentrated design and maximum output power 128kW. Dimensions (H x W x D): 130 mm x 442 mm x 620 mm Energy control module The ECM supports intra-rack parallel CAN communication and inter-rack parallel CAN communication. The intra-rack loadshare control and inter-rack loadshare control are isolated at ECM to achieve better expandability. Battery Module A battery module consists of ten B.B. 9 Ah batteries. An alarm will be generated if the battery module temperature is abnormal and the fuse will be blown for protection if the battery module is abnormal. If there is a fault, the fault indicator turns on locally. Dimensions (H x W x D): 160 mm x 108 mm x 786 mm 10

System Architecture and Key Components 03 Key Components (Optional) Battery Cabinet The battery cabinet meets the long-time power backup requirements. Each battery cabinet can house eight battery strings (each string contains four battery modules) and is equipped with a battery switch. A maximum of four battery cabinets can be connected. Dimensions (H x W x D): 2000 mm x 600 mm x 1200 mm >> Other Optional Components Component Function Antiseismic kit Reinforces the cabinet so that the cabinet meets the requirements of 9 degree seismic fortification intensity. IP21 component Prevents water from dropping into the cabinet, protecting the cabinet to IP21. Battery temperature sensor Feedbacks real-time temperature and humidity data to dynamic environment monitoring system. BSC cable Transmits bus synchronization signals in a dual-bus system. 11

Typical Configuration 01 Configuration scene Typical Configuration Long-time Power Backup Configuration 3+1 power modules 8-16 battery modules Battery integrated cabinet Battery cabinet Battery cabinet Battery cabinet Battery cabinet 36 battery strings 144 battery modules 2-4 battery strings 8 battery strings 8 battery strings 8 battery strings 8 battery strings Battery integrated cabinet: One to three 25 kva power modules, a maximum of four power modules can be configured with one module redundant. Battery module: One battery module contains ten B.B. 12 V 9 Ah batteries and one battery string contains four battery modules. Battery cabinet: Supports a maximum of eight battery strings, that is, 32 battery modules. >> Backup Time Table Unit: min 350 Battery Integrated Cabinet 300 250 1# Battery Cabinet 330 2# Battery Cabinet 3# Battery Cabinet 4# Battery Cabinet 235 200 150 100 50 0 25.6 9.9 5.6 88 44 26 161 74 49 107 68 144 88 25kVA 50kVA 75kVA 12

System Parameters Model UPS5000-E- (25-75kVA) -BF Capacity (kva/kw) 25kVA/kW 50kVA/kW 75kVA/kW Input Output Environment Others Mains Bypass Rated Voltage Output Frequency Rated Voltage Voltage Range Input Wiring Frequency Range Total Harmonic Distortion Input Power Factor 0.99 Rated Voltage Frequency Range Input Wiring Output Power Factor 1 Waveform Output Wiring System Efficiency 96% Overload Capacity 380/400/415Vac 138 to 485Vac 3Ph+N+PE 40 to 70 Hz <3% (100% linear load) 380/400/415Vac 50/60Hz (adjustable, 0.5 to 6Hz, ±2Hz by default) 3Ph+N+PE 380/400/415Vac Tracking the bypass input (Normal mode); 50/60Hz±0.05% (Battery mode) Sine wave; THDv<1% (linear load) 3Ph+N+PE Operation Temperature 0 to 40 ºC Storage Temperature -40 to 70 ºC Relative Humidity Maximum Operation Altitude Noise Integrated Cabinet Power Backup Battery Cabinet (optional) Power Backup Battery Module 110% overload for 60min; 125% overload for 10min; 150% overload for 1min 0% to 95% (No condensing) 0 to 1000m. Above 1000m, derating 1% for each additional 100m 65dB Height Width Depth (mm) 2000 600 1100 Standard configuration 1 to 4 groups of battery (4 to 16 battery modules) Optional battery cabinet, 1 to 8 groups of battery (4 to 32 battery modules) per cabinet, max. 4 cabinets in parallels Hot swappable design. Support battery or empty battery for battery module, battery typical configuration: 10 12V 9Ah Weight 747.4kg 766.5kg 785.6kg Certifications Communications EN/IEC 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, CE, CB, etc. SNMP, RS485, Dry contacts etc. 13

Global Services Huawei has professional UPS service engineers deployed globally, providing global technical support with rapid response speed. Huawei provides customized services that include: 7*24 remote support Software support Active prevention Hardware support Onsite support Others 140+ countries 129+ national spare parts centers 300+ regional warehousing centers 22,000+ servers 24*7 online service North Africa Russia Western Europe Northeast Europe Middle East & Central Asia China Headquarter Latin America West Africa India Southeast Asia & South Pacific South of South America Southeast Africa 14

Copyright Huawei Technologies Co., Ltd. 2016. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd. Trademark Notice, HUAWEI, and are trademarks or registered trademarks of Huawei Technologies Co., Ltd. Other trademarks, product, service and company names mentioned are the property of their respective owners. General Disclaimer The information in this document may contain predictive statements including, without limitation, statements regarding the future financial and operating results, future product portfolio, new technology, etc. There are a number of factors that could cause actual results and developments to differ materially from those expressed or implied in the predictive statements. Therefore, such information is provided for reference purpose only and constitutes neither an offer nor an acceptance. Huawei may change the information at any time without notice. HUAWEI TECHNOLOGIES CO., LTD. Huawei Industrial Base Bantian Longgang Shenzhen 518129, P.R. China Tel: +86-755-28780808 Version No.: M3-022334-20161207-E-2.0 www.huawei.com