Purpose of High Voltage Circuit Switchers

Similar documents
Medium Voltage Metal-Enclosed Power Capacitor Banks

It is the job of the protection system equipment to recognize and remove the fault.

Medium Voltage Metal-Enclosed Thyristor-Switched Harmonic Filter Banks

Medium Voltage Metal-Enclosed Harmonic Filter Systems

Improvements in Transmission Switching Reliability using SF 6 Interrupter Technology

DTRV-EP. COMPLEX DIGITAL PROTECTION FOR 120 kv / MEDIUM VOLTAGE TRANSFORMERS. Application field

Circuit Breakers,Reclosers, Switches, and Fuses

High and Medium Voltage Substation Design, Testing and Maintenance. KSA, Jeddah, Holiday Inn Jeddah Gateway Hotel.

S&C Circuit-Switchers Mark VI

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D.

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

Lessons Learned in Static VAR Compensator Protection

4. CIRCUIT BREAKERS. Functional Emergency Switching

Approval...6. Current Revision...7. Introduction... 8 About PJM Manuals... 8 About This Manual... 8 Using This Manual...9

FUSELESS ists C,H,K & G

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

Voltage Sag Simulator

Specifications. S&C Line-Rupters. For Line and Cable Switching. Outdoor Transmission (115 kv through 230 kv) Conditions of Sale

AIR COOLED MODULAR RECTIFIER

Current Limiting Protector

Voltage Dip-Proofing Inverter

IMP/ 001 / 014 Policy for the Protection of Distribution Networks

BRC SERIES 20kW High Voltage Power Supply

DRS-LA413. Circuit Breaker Failure Relay. Operating Principle DRS-LA413. Operating Principle. Revision: 2 from Dwg.No.: DIL

1. Micro Drive Load sharing application note

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

ES Energy Saver Product Ranges 90Amp 6000Amp

Engineered for Best Fixture Performance. Product features

LED Driver 12W, 3-24 Vdc, 600/825 ma LED Driver 12W, 3-34 Vdc, 350/700 ma

Air & Moulded Case Circuit Breaker Service & Maintenance

Application Techniques CENTERLINE 2100 Motor Control Centers

Voltage Dip-Proofing Inverter

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

Solving High Performance Circuit Protection Needs in Space-constrained, High Density Electronics

WiAutoLink Frequently Asked Questions

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

Microprocessor protection and automation devices

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

Our Power & Control line of Business offers solutions that safely distribute power to your home or business. Our product range includes Low/Medium

Redundant Power Supplies. Keep Machines Up When Power Goes Down

L05055 LED Driver 60W, Vdc, mA L05059 LED Driver 60W, Vdc, mA L1M S-60E L1M S-60E

Innovation for MV distribution

Section 4 Ground-Fault Protection Devices

ELG4125: System Protection

REOHM series 156 Max. continous power: W

Ethernet Protection A Whole Solution Han Zou, ProTek Devices

COOPER POWER SERIES. Fusing Equipment Catalog Data CA132064EN. Effective February 2018 Supersedes January 2014 (240-50)

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

Products Portfolio. Pole mounted Vacuum Recloser

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

for the protection of gas-insulated metal-enclosed switchgear against lightning and switching overvoltages

S&C Scada-Mate Switching Systems Outdoor Distribution (14.4 kv through 34.5 kv)

TENGIZ PROJECT - FIELD SUBSTATION REPLACEMENT

Solid State Remote Power Controller E /627

Prime Point on Wave Energy Reducing Switchgear ( SWITCHGEAR ).

ELSP current-limiting backup fuse

Technical Requirements for High-voltage DC Power Feeding Interfaces of ICT equipment

Mounting and Connections

PFC Mini TM Power Factor Corrected AC-DC Switchers

User Manual. AQ-F215 Simulator

Standards Update Notice (SUN) Issued: April 25, 2017

Understanding SCCR. THE BEST ELECTRICAL CONTROLS BUSINESS ON THE PLANET! Unmatched Service Superior Product Quality Advantage Pricing

Mitigation of Voltage Swells I

Surgelogic Surge Protective Device I-Line Plug-On Unit Series

SWITCHYARD SYSTEM BC1-SS-11-SD TRAINING SYSTEM DESCRIPTION NRG ENERGY, INC. BIG CAJUN 1

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

In the simplest terms, surge protective devices (SPDs) prevent damaging transient voltage surge levels from reaching the devices they protect.

LPI SG + SS480 Spark Gap Surge Filters

Applying branch circuit breakers and supplementary protectors in North America

ELSP current-limiting backup fuse

Application Notes on Generator Protection Schemes

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

High Voltage Contactors

1. Warnings Introduction Mechanical Installation Electrical Installation Application Examples...

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

Geomagnetic Induced Current (GIC) Mitigation System Summary for the White Paper

LAB1 INTRODUCTION TO PSS/E EE461: POWER SYSTEMS COLORADO STATE UNIVERSITY

L05060 LED Driver 100W, Vdc, ma

Miniature Circuit Breakers and Supplementary Protectors. Contents

SE-135 MANUAL GROUND-FAULT GROUND-CHECK MONITOR

S&C IntelliRupter PulseCloser Fault Interrupter Overhead Source-Transfer Application

Surge Protective Device

Circuit Breaker Sentinel (CBS) for SF 6. power circuit breakers

Applying branch circuit breakers and supplementary protectors in North America

UniSec, MV AIS for Secondary Distribution Smart Grid applications

6 Buck Boost Transformers

Bulletin 1489 Circuit Breakers. Selection Guide

Elastimold Molded Vacuum Recloser - MVR

GUJARAT TECHNOLOGICAL UNIVERSITY

Prepared by: Yvon Filion eng. TransÉnergie, a division of Hydro-Québec

L CV1050 Constant Voltage LED Driver, 24Vdc, 25W L1K1MID024V-25E

Control IT. Features and Benefits. Overview. Modular Power System III. Inputs: 120/240 VAC or 125 VDC power feeds allowing mixed AC and DC operation.

Circuit Breakers Type CTI 25M, CTI 45MB

RB60 RANGE. Miniature circuit breakers

ECE 528 Understanding Power Quality. Paul Ortmann (voice) Lecture 23

Micro Contactor MA Series

2.1. SPD, Power Conditioning, PF Capacitors and Harmonic Filters. Contents Description. Introduction. Surge Protection and Power Conditioning

1. Coordination of series-rated devices is permitted where indicated on Drawings.

Transcription:

Purpose of High Voltage Circuit Switchers Vertical interrupter circuit switcher without integral disconnect switch (Figure 2) Three-phase Interruption and Protection Circuit switchers have been developed to overcome some of the limitations of fusing forsubstation power transformers. Circuit switchers have SF6 gas interrupters and are designed to provide three-phase interruption (solving the unbalanced voltage considerations) and to provide protection for transient overvoltages and overloads at a competitive cost between the costs of power fuses and circuit breakers. Additionally they can provide protection from power transformer faults based on differential,sudden pressure, and overcurrent relay schemes as well as critical operating constraints such as for low oil level, high oil or winding temperature, pressure relief device operation, etc. The earliest circuit switchers were designed and supplied as a combination of a circuit breaking interrupter and an in-series isolating disconnect switch. These earliest models (see Fig. 1) had

multiple interrupter gaps per phase on above 69 kv interrupters and grading resistors, thus the necessity for the in-series disconnect switch. Later models have been designed with improved interrupters that have reduced the number of gaps required for successful performance to a single gap per phase, thus eliminating the necessity of the disconnect switch blade in series with the interrupter. Figure 1 - Multiple interrupter gap per phase circuit switcher Circuit switchers are now available in vertical interrupter design (see Fig 2 picture above) or horizontal interrupter design configurations with (see Figure 3) or without (see Figure 4) an integral disconnect switch. The earliest circuit switchers had a 4 ka symmetrical primary fault current interrupting capability, but subsequent design improvements over the years have produced circuit switchers capable of8, 10, 12, 16, 20, 25, 31.5, and 40 ka symmetrical primary fault current interrupting, with the highest of these interrupting values being on par with circuit breaker capabilities.

Figure 3 - Horizontal interrupter circuit switcher with integral vertical break disconnect switch. Horizontal interrupter line switchers provide load breaking, loop splitting, and line dropping capabilities for your most critical line switching applications. Additional applications include transformer magnetizing current interrupting and cable switching. All circuit making and breaking operations are accomplished in SF6 gas, eliminating open air arcs.

Figure 4 - Horizontal interrupter circuit switcher without integral disconnect switch The interrupting speeds of circuit switchers have also been improved from their initial 8 cycle interrupting time to 6 to 5 to 3 cycles, with the 3 cycle offering the same speed as the most commonly available circuit breaker interrupting time. Different model types, configurations, and vintages have different interrupting ratings and interrupting speeds. Circuit switchers have been developed and furnished for applications involving protection of: 1. Power transformers 2. Lines,

3. Cables 4. Capacitor banks, and 5. Line connected or tertiary connected shunt reactors. Circuit switchers can also be employed in specialty applications such as series capacitor bypassing and for load= line =loop interrupting applications where fault-closing capabilit y is required (as fault-closing capability is not a feature inherent in disconnect switch mounted load =line =loop interrupters or in the disconnect switches these interrupters are mounted on). Key Advantages These are the main advantages of HV Circuit Switchers: 1. Makes and breaks circuit in SF6 2. Ships fully assembled to minimize installation time 3. Local visual indication of gas pressure provided by color coded temperature compensated gas gauge 4. Common gas system with gas density switch with low pressure alarm and low pressure lockout for remote status monitoring 5. Compact design and easy installation makes this an ideal switcher for replacement of power fuses to achieve 3 phase protection 6. Straight forward mechanical design insures long life, repeatable operation Rated Duty Cycle O 0.3 sec CO 15 sec CO Source: http://electrical-engineering-portal.com/purpose-of-high-voltage-circuit-switchers