Hardware Manual RM CANview Gateway

Similar documents
Hardware Manual RM CANview

Hardware Manual RM Display 2401

Hardware Manual RM Display 2501 S01..S04

Hardware Manual RM Display 1001

Hardware Manual RM CANlink Bluetooth 2xxx

Content. Sontheim Industrie Elektronik GmbH Page 2 of 15 07/2016 Installation instructions Version 1.2

Operating instructions. Standstill monitor A / / 2011

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Installation instructions Inclination sensor EC2019 EC / / 2013

Serial PROFIBUS Interface

Installation instructions Ethernet switch EC / / 2011

Operating instructions. Speed monitor D / / 2014

Operating instructions Evaluation system for flow sensors VS / / 2013

Operating instructions. Switching amplifier DN0210 DN / / 2015

PCAN-Router FD Universal, programmable Converter for CAN FD and CAN. User Manual. Document version ( )

R60 USB to CAN interface Manual (1.4 EN)

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Modbus TCP/RTU Gateway

Kvaser Leaf Light v2 User s Guide

HARDWARE MANUAL ENGLISH

Kvaser PCIEcan 2xHS v2 User s Guide

R70 Ethernet to CAN interface Manual (1.4 EN)

BNI USB A501. User s Guide

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

BNI IOL K023 BNI IOL K023. User s Guide

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

USB-to-CAN V2. Compact Embedded Automotive Professional USER MANUAL ENGLISH

Assembly and Operating Instructions. NFC module for BDC-i440 control units

USB/RS-485 INTERFACE CONVERTER PD10 TYPE USER S MANUAL

BNI IOL A027 BNI IOL A027

Kvaser Leaf Light v2 User s Guide

PCAN-Repeater DR CAN Repeater for the Decoupling of Bus Segments. User Manual. Document version ( )

WiMOD - ic880a. Application Note AN014 / Version 1.3. USB modifications for direct SPI operation. Document ID: 4000/40140/0079

DN-DP PROFIBUS-DP / DeviceNet-Gateway

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010

BNI IOL Z046. IO-Link 1.1 Sensor hub with extension port User's Guide

Operating instructions IO-Link master CabinetLine AL19xx

EX-RC1 Remote I/O Adapter

BNI IOL K023 BNI IOL K023. User s Guide

Installation- and Operating instructions for CU Port USB 2.0 Hub. Version: 1.3 Date:

PCAN-Optoadapter Plug-on Adapter for Decoupling CAN Networks. User Manual. Document version ( )

CU Compact-Flash card adapter for USB. Version: 1.0 Date:

GT- IRDM-9603 Product description Rev. 2 17/06/2014

Operating Instructions Differential Pressure Transducer PS27

Kvaser Mini PCI Express User s Guide

BNI IOL Z019. IO-Link 1.1 sensor hub With extension port User s Guide

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

USER MANUAL en-us ENGLISH

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Kvaser Leaf Light v2 User s Guide

Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU)

General Operating, Maintenance and Installation Manual

DF PROFI II PC/104-Plus

Operating instructions RFID evaluation unit DTE / / 2016

DF PROFI II PCIe. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II PCIe KUNBUS

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

BNI IOL E012. IO-Link 1.1 sensor/actuator hub with extension port User's Guide

USB-to-CAN FD. Compact Embedded Automotive USER MANUAL ENGLISH

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Serial/Ethernet Converter

Technical Documentation

WiMOD - im880b. Application Note AN017 / Version 1.1. Firmware Update for im880b. Document ID: 4100/40140/0103. Category:

BNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

BNI IOL Z012 BNI IOL-302-S01-Z012 BNI IOL Z042

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

BNI IOL Z046. IO-Link 1.1 sensor/actuator hub with extension port User's Guide

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

Kvaser PCIEcan 4xHS User s Guide

Installation- and Operating instructions for CU Port USB 3.0 Hub. Version: 1.1 Date:

Kvaser USBcan Light User s Guide

EZ864 UMTS Terminal Telit Cellular GSM Engine

SUBCON-PLUS-PROFIB...

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

CANbridge NT. 200 and 420 USER MANUAL EN 1.3

GV204 Impulse Splitter for Incremental Encoders

CAN-USB/2. USB 2.0-CAN-Interface. Hardware Installation and technical Data. to Product C.2066.xx. Installation and technical Data CAN-USB/2 Rev. 1.

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

Kvaser USBcan Light 4xHS User s Guide

BLE232: Manual Copyright 2014 taskit GmbH

Documentation. CU20xx, CU22xx. Ethernet Switch. Version: Date:

DF PROFI II CPCI. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II CPCI KUNBUS

Operating instructions AC010S Compact AS-i E-STOP safety module

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

Operating Instructions SECUTEST SI /12.10

CAN Repeater CAN-CR200, CAN-CR220, CAN-CR210/FO USER MANUAL ENGLISH

Tina 1A Blanking plug

Kvaser PCIcan II User's Guide

Kvaser PCIEcan HS v2 User s Guide

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

CPCI-PS24 24V-Power Supply

Kvaser Linx J1587 User's Guide

SSW5/USB. S5-PLC to USB converter cable US US13. User Manual. Edition 2 / / HW1 and higher

DIN Rail RTU 540CMD01 Data sheet

Transcription:

Hardware Manual RM CANview Gateway 2008 RM Michaelides Software & Elektronik GmbH Donaustraße 14 D-36043 Fulda Germany cvgateway-hw-e.doc

Table Of Contents 1 Legal Regulations... 3 2 About the CANview Gateway... 4 3 Disposal... 4 4 Important information for using CANview Gateway... 5 5 The Connectors... 7 5.1 CAN-Connectors... 8 5.2 USB connector... 9 5.3 Serial interface Connector... 10 5.4 Power connector... 10 6 Mechanical Outlines... 11 6.1 Standard housing... 11 7 Naming Conventions... 12 8 Technical Data... 13 9 Certificate of conformity... 15 10 History... 16 10.1 Hardware Documentation History... 16 10.2 Hardware History... 16 2 2008 RM Michaelides Software & Elektronik GmbH Donaustraße 14 D-36043 Fulda Germany cvgateway-hw-e.doc

1 Legal Regulations Safety instructions These instructions are part of the device. They contain text and illustrations for the correct handling of the unit and must be read before installation or use. Adhere to the information in the documentation. Non-observance of the instructions, operation, which is not in accordance with use as prescribed below incorrect installation or handling, can affect the safety of people and equipment. The device must be installed, connected and put into operation by a qualified electrician. Disconnect the device externally before handling it. Also disconnect any independently supplied output load circuits. As no components to be maintained by the user are contained in the device, the housing must not be opened. The device can only be repaired by the manufacturer. The device must be disposed of in accordance with the national environmental regulations. In case of malfunction of the device or uncertainties, please contact the manufacturer. Tampering with the device can seriously affect the safety of people and equipment. This is not permitted and leads to an exclusion of liability and warranty. This device is not designed for direct connection to telecommunication networks. This device is designed to be used in systems, which must be checked for conformity with legal requirements prior to placing into operation. The integrator of this device is responsible to check and comply with regional directives and requirements. This device is also designed for use in restricted access locations. RM Michaelides GmbH assumes no responsibility for the use of any information contained in this manual and makes no representation that they free of patent infringement. RM Michaelides GmbH does not convey any license under its patent rights nor the rights of others. This device requires an explicit permission of the manufacturer in order to be exported into the USA 2008 RM Michaelides Software & Elektronik GmbH Donaustraße 14 D-36043 Fulda Germany cvgateway-hw-e.doc 3

2 About the CANview Gateway CANview Gateway is designed for a fast data exchange between two CAN networks or as a repeater for long distance CAN networks. The two CAN interfaces are separately galvanically isolated. Optionally received CAN messages can be transmitted via USB to a host PC for monitoring and data analysis. CANview Gateway can be completely powered by its integrated male CAN (CAN 1) connector, the power supply connector or via USB. It is equipped with a high-performance 16-Bit microcontroller. The firmware and configuration can be updated using the integrated serial interface. This makes it possible to program the device to support proprietary CAN protocols or to run customer specific complex applications. CANview Gateway can be delivered as an OEM device or in a rugged aluminum case for use in harsh environments. The device state is indicated by four LEDs. The device is available in various options. It may optionally be equipped with a CAN termination resistor and/or different connectors. The device is also available in an IP67 version. The different ordering options are described in chapter 7 Naming Conventions on page 12. For further information, support and customer specific hardware and firmware adaptations see our web page: www.rmcan.com - Support or contact us via e-mail: mailto:info@rmcan.com 3 Disposal Observe your national laws when disposing the device and its package. 4 2008 RM Michaelides Software & Elektronik GmbH Donaustraße 14 D-36043 Fulda Germany cvgateway-hw-e.doc

4 Important information for using CANview Gateway This device CANview Gateway 2101 is designed to be used in systems, which must be checked for conformity with legal requirements prior to placing into operation. The integrator of this device is responsible to check and comply with regional directives and requirements. Observe the information of the devices manuals. Non-observance of the notes, operation that is not in accordance with the use as prescribed below, wrong installation or handling can result in serious harm concerning the safety of people and plant. The operation manual has to be stored available at any time and has to be handed over to each user. The device may only be installed, connected and commissioned by qualified personnel. Disconnect the device externally before doing any work on it. If necessary, also disconnect separately supplied output circuits. In the case of malfunctions or uncertainties, please contact the manufacturer. Tampering with the device can lead to considerable risks for the safety of people and plant. It is not permitted and leads to an exclusion of any liability and warranty claims. This device requires an explicit permission of the manufacturer in order to be exported into the USA. The type label and the housing must not be contacted (particularly cleaned) with any kind of solvent-containing substance. Operation The device must not be operated in machines and applications where life depends on the proper operation of this piece of equipment. CAN The signals on the CAN connection terminals CAN-Low and CAN-High must match the signals on the CAN-terminals of the connected devices. GND of the CAN-connector has to be connected to CAN-GND. The CAN interfaces are separately galvanically isolated against the rest of the device. The shielding must be placed on the power side only as shielding of CAN ports will neutralize the galvanic isolation. Because of the galvanic isolation of the CAN interface, the CAN Ground and the power supply ground should not be short-circuited. Otherwise the galvanic isolation will be suspended. 2008 RM Michaelides Software & Elektronik GmbH Donaustraße 14 D-36043 Fulda Germany cvgateway-hw-e.doc 5

To estimate the maximum length of the CAN bus-line for a given CAN baud rate, the following table can be used: CAN Baud Rate 1Mbit/s Max. bus length 25m 800 kbit/s 50m 500 kbit/s 100m 250 kbit/s 250m 125kbit/s 50kbit/s 500m 1000m 6 2008 RM Michaelides Software & Elektronik GmbH Donaustraße 14 D-36043 Fulda Germany cvgateway-hw-e.doc

5 The Connectors The drawing below this text shows an overview of the explained hardware components. 5.3 Serial interface Connector 5.1 CAN-Connectors 5.2 USB connector 5.4 Power connector 5.1 CAN-Connectors Depending on the different ordering options as described in chapter 7 Naming Conventions on page 12, the device may be equipped with just a sub set of the connectors shown above. The device may only be installed, connected and commissioned by qualified personnel. Disconnect the device externally before doing any work on it. If necessary, also disconnect separately supplied output circuits. 2008 RM Michaelides Software & Elektronik GmbH Donaustraße 14 D-36043 Fulda Germany cvgateway-hw-e.doc 7

5.1 CAN-Connectors Apart from connecting CANview Gateway to the first CAN bus, the CAN-connector 1 can be used to supply the device with power. If used so the CANview Gateway has to be connected to the CAN-Bus in order to operate. The device can be equipped with two 9-pole Sub-D connectors (male/can1; female/can2) or with a male 8-pole M12 connector which connects both CAN interfaces. The different ordering options are described in chapter 7 Naming Conventions on page 12. The Pin assignments of the Sub-D CAN-connectors are according to the CiA DR303-1 and are shown in the tables and drawings below. The female screwlock thread diameter is UNC 4-40. Because the CAN interface is galvanically isolated, the CAN-Ground and the power supply ground should not be short-circuited. Otherwise the galvanic isolation will be suspended. Table 1: Sub-D 9-pole CAN1-connector pin assignment (male) Destination Pin Potential CAN Ground CAN-L Power supply 6 GND 1 2 4 3 5 9 9 36 V DC GND 6 7 9 8 CAN interface 2 CAN-L 3 CAN Ground 7 CAN-H CAN-H VCC Front view of CANview Gateway Sub-D-9 CAN1 connector (male) Table 2: Sub-D 9-pole CAN2-connector pin assignment (female) Destination Pin Potential CAN interface 2 CAN-L 5 4 2 3 CAN Ground 1 CAN-L 3 CAN Ground 9 8 6 7 7 CAN-H CAN-H Front view of CANview Gateway Sub-D-9 CAN2 connector (female) 8 2008 RM Michaelides Software & Elektronik GmbH Donaustraße 14 D-36043 Fulda Germany cvgateway-hw-e.doc

Table 3: M12 CAN-connector pin assignment Destination Pin Potential CAN interface 1 CAN1-H 2 CAN1-L 3 CAN2-L 4 CAN2-H VCC GND CAN1-H 5 6 4 7 8 3 1 2 CAN2-H CAN2-L CAN1-L Power supply 5 Not connected 6 Not connected 7 GND 8 9 36 V DC Front view of CANview Gateway M12 CAN connector (male) 5.2 USB connector The USB-Port is used to interface the CANview Gateway with the PC. It provides a data transmission rate of up to 12Mbit/s. For interfacing the device with a PC a standard USB cable can be used. The device can be powered via the USB interface. It is recommeded to power the device by a USB Host or by a self powered USB Hub. On bus powered Hubs, the Voltage drop of V Bus can be too high under worst case conditions which might prevent the device from starting up. Table 4: USB connector Destination Pin Potential USB Connector (B Type) 1 V Bus 2 D- 3 D+ 4 GND Front view of CANview Gateway USB connector (B Type) 2008 RM Michaelides Software & Elektronik GmbH Donaustraße 14 D-36043 Fulda Germany cvgateway-hw-e.doc 9

5.3 Serial interface Connector The serial interface connector is used to update the device's firmware and to write the configuration to the device. The CANview Gateway serial interface is equipped with a male 9-pole Sub-D connector. A non-crossed RS232 cable may be used to connect the CANview Gateway to the Computer to download new Firmware or the configuration. The serial interface may also be used for customer specific applications. The female screwlock thread diameter is UNC 4-40. For Firmware download please refer to the RM 16x-Programmer manual. For Configuration download please refer to the CANview Gateway Configurator manual. Table 5: Serial interface connector pin assignment Destination Pin Potential Serial interface (RS232) 2 TxD (CANview Gateway) 3 RxD (CANview Gateway) 4 DSR (starts the device in firmware update mode) 5 GND 7 CTS (resets the device) CTS TxD RxD 1 2 4 3 6 7 8 9 DSR Front view of CANview Gateway Serial interface connector (male) 5 GND 5.4 Power connector The Power connector is used to power the CANview Gateway if the supply voltage is not provided via the CAN bus cable. Table 6: Power connector pin assignment Destination Pin Potential Power Connector 1 GND 9...36V DC GND 2 9 36 V DC Front view of CANview Gateway Power connector 10 2008 RM Michaelides Software & Elektronik GmbH Donaustraße 14 D-36043 Fulda Germany cvgateway-hw-e.doc

6 Mechanical Outlines 6.1 Standard housing Figure 1: Standard housing of CANview Gateway 2008 RM Michaelides Software & Elektronik GmbH Donaustraße 14 D-36043 Fulda Germany cvgateway-hw-e.doc 11

7 Naming Conventions The CANview Gateway Family is available with various Options. To differentiate between these options four ciphers are attached to the family name CANview Gateway. These name extension can be found on the rating plate on the back of the housing. The following names have been defined until now: Device name Description Order number CANview Gateway 2001 CANview Gateway 2002 CANview Gateway 2101 Others CANview Gateway in aluminum housing - Sub-D 9-pole (male) CAN1 connector - Sub-D 9-pole (female) CAN2 connector - CAN1 and CAN2 are galvanically isolated - Configuration update via RS232 interface - RS232 and power connector hidden behind hinged flap CANview Gateway in aluminum housing - Sub-D 9-pole (male) CAN1 connector - Sub-D 9-pole (female) CAN2 connector - CAN1 and CAN2 are galvanically isolated - Configuration update via RS232 interface CANview Gateway in aluminum housing - Sub-D 9-pole (male) CAN1 connector - Sub-D 9-pole (female) CAN2 connector - CAN1 and CAN2 are galvanically isolated - USB interface - Configuration update via RS232 interface - RS232 and power connector hidden behind hinged flap 253 002 007 253 002 009 253 002 008 On request 12 2008 RM Michaelides Software & Elektronik GmbH Donaustraße 14 D-36043 Fulda Germany cvgateway-hw-e.doc

8 Technical Data Table 7: Technical Data of CANview Gateway Value Supply Voltage (V+) Current Drawn Operating Temp. LEDs IP rating Additional features Controller Flash Memory Size SRAM Size EEPROM Size CAN Specification CAN-Bus coupling Galvanic Isolation Max. Baud Rate Description 10... 30V DC < 60mA @ 30V DC < 80mA @ 24V DC < 210mA @ 10V DC -40 +60 C (without USB interface) in restricted access locations: 40 +80 C (without USB interface, with appropriate interconnection cables) 0 +60 C (with USB interface) in restricted access locations: 0 +70 C (with USB interface, with appropriate interconnection cables) 4 (ON, CAN1 communication, Error, CAN2 communication) Devices with USB interface: 5 (ON, CAN1 communication, Error, CAN2 communication, USB communication) IP20 16 Bit a) Optional IP67 rated M12 CAN connector b) Optional Low speed CAN interface 128 kb (optional: external data-flash up to 8 MB) 262 KB 8 KB 2.0 A/B According to ISO 11898, High speed Both CAN interfaces seperately galvanically isolated 1Mbit/s 2008 RM Michaelides Software & Elektronik GmbH Donaustraße 14 D-36043 Fulda Germany cvgateway-hw-e.doc 13

Value Description CAN Protocol Layer 2 Order Numbers See Naming Conventions on page 12 Optional Parts Standard Housing 136 000 055 CAN Cable 9-pin SUBD \ 9-pin SUBD Power CAN cable with SubD-9 (f) and SubD-9 (f), 2m with power connector. 136 000 004 CAN Cable 9-pin SUBD \ 9-pin SUBD CAN cable with SubD-9 (f) and SubD-9 (f), 2m 142 200 010 Wall mounting set Aluminum Dimensions in mm 120 x 85 x 35 Weight in grams 230 Certifications UL File number: E205530 CANview Gateway 2001/2002: CE EN61000-6-3:2005; EN61326-1:2006; EN61000-6-2:2006; ISO7637-3:1995 e1 (Type approval number: e1*72/245*2006/28*5016*00) 14 2008 RM Michaelides Software & Elektronik GmbH Donaustraße 14 D-36043 Fulda Germany cvgateway-hw-e.doc

9 Certificate of conformity 2008 RM Michaelides Software & Elektronik GmbH Donaustraße 14 D-36043 Fulda Germany cvgateway-hw-e.doc 15

10 History 10.1 Hardware Documentation History V1.00 (13.12.2006): - First official version V1.01 (13.03.2007): - Hint for immunity related functions added - Additional device options added - Temperature range changed for devices without USB port - Screwlock thread diameter added V1.02 (11.07.2007): - CE certificate added - e1 type approval added V1.03 (07.04.2008): - Telecommunication network and restricted access locations hints added - Temperature range: restricted access locations added - IP rating added V1.04 (14.04.2008): - Temperature range for restricted access locations changed V1.05 (25.04.2008): - Voltage range changed - Temperature range: appropriate interconnection cables added 10.2 Hardware History V2.00 (13.12.2006): - First official version V2.02 (18.04.2007): - Corrections due to CE certification 16 2008 RM Michaelides Software & Elektronik GmbH Donaustraße 14 D-36043 Fulda Germany cvgateway-hw-e.doc