HPE PSR300-12A & PSR300-12D1

Similar documents
HPE FlexNetwork MSR Router Series

HPE StoreEver MSL6480 Tape Library CLI Utility Version 1.0 User Guide

HP 527 Dual Radio ac Unified Wired-WLAN Walljack

HP 10500/ G Unified Wired-WLAN Module

HPE Intelligent Management Center

H3C Transceiver Modules and Network Cables

HP 5920 & 5900 Switch Series

HP 5120 EI Switch Series

HPE 3PAR OS MU2 Patch 53 Release Notes

About the HP 830 Series PoE+ Unified Wired-WLAN Switch and HP 10500/ G Unified Wired-WLAN Module

HP Intelligent Management Center Remote Site Management User Guide

HP High-End Firewalls

About the Configuration Guides for HP Unified

HPE Intelligent Management Center

HPE Intelligent Management Center

HPE 3PAR OS GA Patch 20 Release Notes

Marvell BIOS Utility User Guide

HP MSR Router Series. IPX Configuration Guide(V5) Part number: Software version: CMW520-R2513 Document version: 6PW

Sun StorageTek. 1U Rackmount Media Tray Reference Guide. Sun Doc Part Number: Second edition: December 2007

Replacing the Battery HP t5730 and t5735 Thin Clients

HP A5120 EI Switch Series IRF. Command Reference. Abstract

HP 5920 & 5900 Switch Series

HP UFT Connection Agent

HP FlexFabric 5700 Switch Series

HP 5830 Switch Series. Installation Guide. Abstract

Aruba JL311A Cable Guard Installation Instructions

HPE 5820X & 5800 Switch Series

H3C S9800 Switch Series

HP 5820X & 5800 Switch Series IRF. Command Reference. Abstract

HPE StoreVirtual OS Update Guide

Upgrading and Servicing Guide

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

HP 1920 Gigabit Ethernet Switch Series

HPE Synergy 40Gb F8 Switch Module

HPE ProLiant Updates Catalog (v ) User Guide

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Upgrading and Servicing Guide

Guidelines for using Internet Information Server with HP StorageWorks Storage Mirroring

Integrated Smart Update Tools for Windows and Linux User Guide

StoreOnce 6500 (88TB) System Capacity Expansion Guide

M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions

TRC-190 User s Manual

HPE 3PAR OS MU5 Patch 49 Release Notes

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

H3C SecBlade SSL VPN Card

TRC-190 User s Manual

HP 3PAR OS MU1 Patch 11

HP 5130 EI Switch Series

H3C WA4320-ACN-PI Access Point

Managing Individual Components

Hard Drive/Solid-State Drive Replacement Instructions

HP Intelligent Management Center v7.1 MySQL 5.6 Installation and Configuration Guide (Windows)

Wall-Mounting your HP TouchSmart. User Guide

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

To connect the AC adapter:

SCSI Cable Installation Instructions

Motion LE1700 Tablet PC Hard Disk Drive Upgrade Procedure

Installation AC Power Supply

XTM 1050 Replacement Parts Installation

HPE StoreVirtual Storage Application Aware Snapshot Manager Deployment Guide

Replacing the Gateway 200ARC Keyboard

HPE 3PAR OS MU3 Patch 24 Release Notes

HP StoreVirtual Storage Multi-Site Configuration Guide

H3C S5130-EI Switch Series

Catalyst 6500 Series Wireless LAN Services Module Installation and Verification Note

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

HPE Insight Management WBEM Providers for Microsoft Windows Eventlog Messages

Installation and Getting Started Guide. HP ProCurve 600/610 External Power Supplies. PoE. Power over Ethernet Devices

IDE Connector Customizer Readme

Installing the A4505A PCI Module Upgrade. HP Part No. A Edition E0297 Printed in U.S.A.

HP 5920 & 5900 Switch Series

HPE 1/8 G2 Tape Autoloader and MSL Tape Libraries Encryption Kit User Guide

H3C S12500 Routing Switch Series

Replacing the Power Supply

Upgrading and Servicing Guide

HPE 3PAR OS MU3 Patch 28 Release Notes

Maintaining the ERX System

Upgrading and Servicing Guide

HPE 3PAR OS MU2 Patch 36 Release Notes

HP AutoPass License Server

H3C S5560-EI Switch Series

HP 5820X & 5800 Switch Series

HPE StoreOnce 5100 System Capacity Upgrade Guide

HPE 3PAR OS MU3 Patch 23 Release Notes

hp uninterruptible power system r12000 xr models installation instructions

HP CX4 & XFP Interface Cards User Guide

External Media Cards User Guide

HP 3PAR OS MU3 Patch 18 Release Notes

HP ProLiant SL160z G6 Server

Replacing the Gateway M305 Optical Drive

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Installing and Upgrading Memory and Virtual Private Network Modules

Olive_QS_SL.book Page 1 Wednesday, September 18, :41 PM Quick Start

HP P6300/P6500 EVA Fibre Channel Controller Replacement Instructions

Replacing the Gateway M275 Keyboard

HP Business Service Management

HP 5500 EI & 5500 SI Switch Series

Hewlett Packard Enterprise. HPE OmniStack for vsphere Upgrade Guide

HP Business Availability Center

External Media Cards. User Guide

Transcription:

HPE PSR300-12A & PSR300-12D1 Power Supplies User Guide 5998-1604s Part number: 5998-1604s Document version: 6PW103-20160405

Copyright 2015, 2016 Hewlett Packard Enterprise Development LP The information contained herein is subject to change without notice. The only warranties for Hewlett Packard Enterprise products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. Hewlett Packard Enterprise shall not be liable for technical or editorial errors or omissions contained herein. Confidential computer software. Valid license from Hewlett Packard Enterprise required for possession, use, or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor s standard commercial license. Links to third-party websites take you outside the Hewlett Packard Enterprise website. Hewlett Packard Enterprise has no control over and is not responsible for information outside the Hewlett Packard Enterprise website. Acknowledgments Intel, Itanium, Pentium, Intel Inside, and the Intel Inside logo are trademarks of Intel Corporation in the United States and other countries. Microsoft and Windows are trademarks of the Microsoft group of companies. Adobe and Acrobat are trademarks of Adobe Systems Incorporated. Java and Oracle are registered trademarks of Oracle and/or its affiliates. UNIX is a registered trademark of The Open Group.

Contents Introduction to the power supply 1 Introduction 1 Specifications 3 Panel 4 Status LEDs 5 Installing and removing the power supply 8 Precautions 8 Tools 9 Installing and removing the power supply 9 Installing the power supply 9 Removing the power supply 11 Connecting the power cord 11 Connecting the AC power cord 12 Connecting the DC power cord 13 Document conventions and icons 15 Conventions 15 Network topology icons 17 Support and other resources 19 Accessing Hewlett Packard Enterprise Support 19 Accessing updates 19 Websites 20 Customer self repair 21 Remote support 22 Documentation feedback 22 i

Introduction to the power supply Introduction The PSR300-12A (JC087A) is an AC-input and DC-output power supply; the PSR300-12D1 (JC090A) is a DC-input and DC-output power supply. They both can convert the input voltage to 12 V that is required by the powered device, and their maximum output power is 300 W. Table 1 Features supported by the PSR300-12A/PSR300-12D1 Feature Protection Redundancy Hot swapping Description Output over-voltage protection, output short-circuit protection, output current-limiting protection, and overheat protection. Supports parallel connection of two power supplies, implementing 1+1 redundant current sharing. When the device operates properly, you can power off a power supply of the 1+1 redundant power supply system and remove it from the device. Auto-recovery support of the PSR 300-12A and PSR 300-12D1 in the protection status is shown in Table 2. 1

Table 2 Protection functions of the PSR 300-12A and PSR 300-12D1 Protection function Over-voltage protection Short-circuit protection Current-limiting protection Overheat protection Status No power supply with the power supply deadly locked No power supply with the power supply deadly locked No power supply with the power supply deadly locked No power supply Auto-recovery support Not supported Not supported Not supported Restoring power supply after the temperature decreases NOTE: When a power supply is deadly locked, it does not support the auto-recovery function. In this case, you need to power off the power supply, disconnect the power cord and connect it again, and then power on the power supply. After all these operations, the power supply gets restored. In case of overheat protection, take measures to decrease the temperature of the device so that the power supply can recover itself. 2

Specifications Table 3 PSR300-12A/PSR300-12D1 specifications Item Rated voltage range Max voltage range Output voltage Max output current Max output power Dimensions (H W D) Operating temperature Storage temperature Specifications PSR300-12A: 100 VAC to 240 VAC; 50 Hz or 60 Hz PSR300-12D1: 48 VDC to 60 VDC PSR300-12A: 90 VAC to 264 VAC; 47 Hz to 63 Hz PSR300-12D1: 40.5 VDC to 72 VDC 12 V 25 A 300 W 40.1 101.6 228 mm (1.58 4.00 8.98 in) 0 C to 55 C (32 F to 131 F) 40 C to 70 C ( 40 F to +158 F) 3

Panel Figure 1 Panel of the PSR300-12A (1) Power switch (push O to switch off and push to switch on) (2) AC receptacle (3) Tab (4) Power supply handle (5) Status LED for DC output (6) Status LED for AC input (7) Captive screw 4

Figure 2 Panel of the PSR300-12D1 (1) Power switch (push O to switch off and push to switch on) (2) DC power receptacle (3) Tab (4) Power supply handle (5) Status LED for DC output (6) Status LED for DC input (7) Screw hole of the plug (8) Captive screw Status LEDs The PSR300-12A/PSR300-12D1 has two LEDs, which indicate the input and output statuses of the power supply. Table 4 describes the colors and working status of the LEDs in different cases. 5

Table 4 Description of the LEDs Power supply LED Color Status PSR300-12A AC OK DC OK Off On Off On No power is input or an input failure occurs. The power input is normal. No power is output or an output failure occurs. The power output is normal. PSR300-12D1 Input Output Off ON Off On No power is input or an input failure occurs. The power input is normal. No power is output or an output failure occurs. The power output is normal. 6

NOTE: In normal cases, the input and output LEDs of the power supply stay in the off state after you connect the power cord without switching on the power supply; they both turn on after you power on and switch on the power supply. However, if the input LED is on but the output LED is off, this case may be caused by output short-circuit, output over-current, output over-voltage, or over-temperature. To solve such cases, take the following actions: Switch off the power supply and disconnect the power cord, and then reconnect the power cord and switch on the power supply to check whether the power supply can work properly. This action can solve the locking of the power supply due to output short-circuit, output over-current, or output over-voltage. If the above action does not work, the case may be caused by over-temperature. Take actions to cool down the power supply, and then it can work properly. 7

Installing and removing the power supply This chapter describes how to install and remove the power supply and the power cord. To prevent damage to the device and personal injury, follow the installation and removal procedures illustrated in Figure 3 and Figure 4, respectively. Figure 3 Installation procedure Figure 4 Removal procedure Precautions When installing and removing a power supply, note the following guidelines: Wear an ESD-preventive wrist strap and ensure a good skin contact before installing or removing the power supply. Before installing the power supply, make sure that the operating voltage provided by the power source is consistent with that marked on the power supply, and the output voltage of the power supply is consistent with the powered device, thus to prevent damage to the power supply and powered device. 8

Do not touch any naked wire or terminal. Doing so may result in a personal injury. Never place the power supply in wet locations and prevent fluid from leaking into the power supply. Do not often open the shell of the power supply to prevent damage to the power supply. If a failure occurs on the internal wires or units, contact the technical stuff to troubleshoot the problem. Tools Prepare the following tools for installation and removal: Flat-blade screwdriver Phillips screwdriver ESD-preventive wrist strap Installing and removing the power supply The installation/removal procedures for the PSR300-12A and PSR300-12D1 are similar. This document takes the PSR300-12A as an example to describe the installation and removal of the power supply. CAUTION: Before installation and removal, make sure the power supply is switched off and no power cord is connected to the power supply. Installing the power supply 1. Wear an ESD-preventive wrist strap, and make sure the wrist strap makes good skin contact and is well grounded. 9

2. Take the power supply from the package and check that the input mode of the power supply is as required. 3. Face the slot and plug in the power supply. 4. Insert the power supply with the upside up. Grasping the handle of the power supply with one hand and supporting the power supply bottom with the other, slide the power supply slowly along the guide rails into the slot (see callout 1 in Figure 5). 5. Fasten the captive screw on the power supply clockwise with a Philips screwdriver until the power supply seats into the chassis (see callout 2 in Figure 5). Figure 5 Install a power supply 2 1 10

NOTE: If the slot has a filler panel, remove it before inserting the power supply. To prevent damage to the power supply or the connector on the backplane of the powered device, insert the power supply gently. If you encounter a hard resistance while inserting the power supply, pull out the power supply and then insert it again. If the captive screw cannot be tightly fixed, check the installation of the power supply. Removing the power supply 1. Wear an ESD-preventive wrist strap, and make sure that the wrist strap makes good skin contact and is well grounded. 2. Switch off the power supply and disconnect the power cord. 3. Face the power supply to be removed from the powered device. 4. Loosen the captive screw of the power supply anti-clockwise with a Philips screwdriver until the captive screw falls off the powered device. 5. Grasping the handle of the power supply with one hand, pull it part way out. Supporting the power supply bottom with the other hand, pull the power supply slowly along the guide rails out of the slot. NOTE: Put the power supply into an antistatic bag after removal. Connecting the power cord After you insert the power supply into the device, you can connect the power cord. For an AC-powered device, use an AC power cord to 11

connect the power source; for a DC-powered device, use a DC power cord to connect the power source. Connecting the AC power cord 1. Switch off the AC power supply 2. Connect one end of the AC power cord to the AC receptacle on the power supply (see Figure 6). 3. Connect the other end of the AC power cord to the power source. Figure 6 Connect the AC power cord 12

Connecting the DC power cord CAUTION: The power cord color code scheme in Figure 7 is for illustration only. The cable delivered for your country or region might use a different color scheme. When you connect a power cord, always identify the polarity symbol on its wires. To connect the DC power cord: 1. Switch off the DC power supply. 2. Insert the DC connector into the DC power receptacle. See callout 1 in Figure 7. The connector of the DC power cord and the DC power receptacle are foolproof. Make sure the connector is correctly oriented. 3. Use a flat-blade screwdriver to fix the two screws on the DC plug clockwise to secure the plug to the DC receptacle (see callout 2 in Figure 7). 4. Connect the other ends of the wires to the DC power source wiring terminals, with the negative wire ( or L ) to the negative terminal ( ) and the positive wire (+ or M/N) to the positive terminal (+). 13

Figure 7 Connect the DC power cord 2 2 1 14

Document conventions and icons Conventions This section describes the conventions used in the documentation. Port numbering in examples The port numbers in this document are for illustration only and might be unavailable on your device. Command conventions Convention Boldface Italic [ ] { x y... } [ x y... ] { x y... } * Description Bold text represents commands and keywords that you enter literally as shown. Italic text represents arguments that you replace with actual values. Square brackets enclose syntax choices (keywords or arguments) that are optional. Braces enclose a set of required syntax choices separated by vertical bars, from which you select one. Square brackets enclose a set of optional syntax choices separated by vertical bars, from which you select one or none. Asterisk marked braces enclose a set of required syntax choices separated by vertical bars, from which you select at least one. 15

Convention [ x y... ] * &<1-n> # Description Asterisk marked square brackets enclose optional syntax choices separated by vertical bars, from which you select one choice, multiple choices, or none. The argument or keyword and argument combination before the ampersand (&) sign can be entered 1 to n times. A line that starts with a pound (#) sign is comments. GUI conventions Convention Boldface > Description Window names, button names, field names, and menu items are in Boldface. For example, the New User window appears; click OK. Multi-level menus are separated by angle brackets. For example, File > Create > Folder. Symbols Convention WARNING! CAUTION: Description An alert that calls attention to important information that if not understood or followed can result in personal injury. An alert that calls attention to important information that if not understood or followed can result in data loss, data corruption, or damage to hardware or software. 16

Convention IMPORTANT: NOTE: TIP: Description An alert that calls attention to essential information. An alert that contains additional or supplementary information. An alert that provides helpful information. Network topology icons Convention Description Represents a generic network device, such as a router, switch, or firewall. Represents a routing-capable device, such as a router or Layer 3 switch. Represents a generic switch, such as a Layer 2 or Layer 3 switch, or a router that supports Layer 2 forwarding and other Layer 2 features. Represents an access controller, a unified wired-wlan module, or the access controller engine on a unified wired-wlan switch. Represents an access point. T Represents a wireless terminator unit. 17

Convention T Description Represents a wireless terminator. Represents a mesh access point. Represents omnidirectional signals. Represents directional signals. Represents a security product, such as a firewall, UTM, multiservice security gateway, or load balancing device. Represents a security card, such as a firewall, load balancing, NetStream, SSL VPN, IPS, or ACG card. 18

Support and other resources Accessing Hewlett Packard Enterprise Support For live assistance, go to the Contact Hewlett Packard Enterprise Worldwide website: www.hpe.com/assistance To access documentation and support services, go to the Hewlett Packard Enterprise Support Center website: www.hpe.com/support/hpesc Information to collect Technical support registration number (if applicable) Product name, model or version, and serial number Operating system name and version Firmware version Error messages Product-specific reports and logs Add-on products or components Third-party products or components Accessing updates Some software products provide a mechanism for accessing software updates through the product interface. Review your product documentation to identify the recommended software update method. To download product updates, go to either of the following: 19

Hewlett Packard Enterprise Support Center Get connected with updates page: www.hpe.com/support/e-updates Software Depot website: www.hpe.com/support/softwaredepot To view and update your entitlements, and to link your contracts, Care Packs, and warranties with your profile, go to the Hewlett Packard Enterprise Support Center More Information on Access to Support Materials page: www.hpe.com/support/accesstosupportmaterials IMPORTANT: Access to some updates might require product entitlement when accessed through the Hewlett Packard Enterprise Support Center. You must have an HP Passport set up with relevant entitlements. Websites Website Networking websites Hewlett Packard Enterprise Networking Information Library Hewlett Packard Enterprise Networking website Hewlett Packard Enterprise Networking My Support Link www.hpe.com/networking/reso urcefinder www.hpe.com/info/networking www.hpe.com/networking/sup port 20

Website General websites Hewlett Packard Enterprise Information Library Hewlett Packard Enterprise Support Center Contact Hewlett Packard Enterprise Worldwide Subscription Service/Support Alerts Software Depot Customer Self Repair (not applicable to all devices) Insight Remote Support (not applicable to all devices) Link www.hpe.com/info/enterprise/ docs www.hpe.com/support/hpesc www.hpe.com/assistance www.hpe.com/support/e-updat es www.hpe.com/support/softwar edepot www.hpe.com/support/selfrep air www.hpe.com/info/insightremo tesupport/docs Customer self repair Hewlett Packard Enterprise customer self repair (CSR) programs allow you to repair your product. If a CSR part needs to be replaced, it will be shipped directly to you so that you can install it at your convenience. Some parts do not qualify for CSR. Your Hewlett Packard Enterprise authorized service provider will determine whether a repair can be accomplished by CSR. For more information about CSR, contact your local service provider or go to the CSR website: www.hpe.com/support/selfrepair 21

Remote support Remote support is available with supported devices as part of your warranty, Care Pack Service, or contractual support agreement. It provides intelligent event diagnosis, and automatic, secure submission of hardware event notifications to Hewlett Packard Enterprise, which will initiate a fast and accurate resolution based on your product s service level. Hewlett Packard Enterprise strongly recommends that you register your device for remote support. For more information and device support details, go to the following website: www.hpe.com/info/insightremotesupport/docs Documentation feedback Hewlett Packard Enterprise is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (docsfeedback@hpe.com). When submitting your feedback, include the document title, part number, edition, and publication date located on the front cover of the document. For online help content, include the product name, product version, help edition, and publication date located on the legal notices page. 22