ADNI, ADNI_QH, SURVEY. Geometry. connection

Similar documents
Philips MRI Protocol Dump Created on Comment Software Stream

ADNI GO - ADNI 2 Human7 (9) 38:30.1

SIEMENS MAGNETOM Avanto syngo MR B15

Orthopedic MRI Protocols. Philips Panorama HFO

SOP: Brain MRI Inital version Gorm Greisen. CONTENT 1.0 Timing of Brain MRI Informed consent...1

SIEMENS MAGNETOM Avanto syngo MR B15

COBRE Scan Information

SIEMENS MAGNETOM Verio syngo MR B15V

SIEMENS MAGNETOM Skyra syngo MR D13

Lab Location: MRI, B2, Cardinal Carter Wing, St. Michael s Hospital, 30 Bond Street

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

SIEMENS MAGNETOM Verio syngo MR B17

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

Page 1 of 9. Protocol: adult_other_adni3basichumanprotocol25x_ _ _1. 3 Plane Localizer. 3 Plane Localizer PATIENT POSITION

SIEMENS MAGNETOM Symphony syngo MR A30

MRI. When to use What sequences. Outline 2012/09/19. Sequence: Definition. Basic Principles: Step 2. Basic Principles: Step 1. Govind Chavhan, MD

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2006

SIEMENS MAGNETOM TrioTim syngo MR B17

A Virtual MR Scanner for Education

MRI image formation 8/3/2016. Disclosure. Outlines. Chen Lin, PhD DABR 3. Indiana University School of Medicine and Indiana University Health

Siemens AG, Healthcare Sector. syngo MR D13 0. Supplement - Parameters and image text 0.

Tina Pavlin 12 March 2013

Diffusion MRI Acquisition. Karla Miller FMRIB Centre, University of Oxford

White Pixel Artifact. Caused by a noise spike during acquisition Spike in K-space <--> sinusoid in image space

MRI Physics II: Gradients, Imaging

Functional MRI. Jerry Allison, Ph. D. Medical College of Georgia

Role of Parallel Imaging in High Field Functional MRI

(a Scrhon5 R2iwd b. P)jc%z 5. ivcr3. 1. I. ZOms Xn,s. 1E IDrAS boms. EE225E/BIOE265 Spring 2013 Principles of MRI. Assignment 8 Solutions

Head motion in diffusion MRI

TOPICS 2/5/2006 8:17 PM. 2D Acquisition 3D Acquisition

MR Advance Techniques. Vascular Imaging. Class III

Slide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.

3-D Gradient Shimming

CHAPTER 9: Magnetic Susceptibility Effects in High Field MRI

8/11/2009. Common Areas of Motion Problem. Motion Compensation Techniques and Applications. Type of Motion. What s your problem

Scan Acceleration with Rapid Gradient-Echo

Fast Imaging Trajectories: Non-Cartesian Sampling (1)

Fast Imaging UCLA. Class Business. Class Business. Daniel B. Ennis, Ph.D. Magnetic Resonance Research Labs. Tuesday (3/7) from 6-9pm HW #1 HW #2

GE Healthcare CLINICAL GALLERY. Discovery * MR750w 3.0T. This brochure is intended for European healthcare professionals.

MRI Imaging Options. Frank R. Korosec, Ph.D. Departments of Radiology and Medical Physics University of Wisconsin Madison

Imaging Notes, Part IV

Breast MRI Accreditation Program Clinical Image Quality Guide

Corso di laurea in Fisica A.A Fisica Medica 4 TC

Applications Guide for Interleaved

New Technology Allows Multiple Image Contrasts in a Single Scan

CATNAP User Manual v1.0

Gradient-Echo. Spin-Echo. Echo planar. Assessment of Regional Function Assessment of Global. Parallel Imaging. Function. Steady State Imaging

Field Maps. 1 Field Map Acquisition. John Pauly. October 5, 2005

Patient Specific. Protocol Identification Number (PID) Must be on each individual. MRI Image

QIBA PET Amyloid BC March 11, Agenda

Error! Bookmark not defined. Error! Bookmark not defined.

Short Tutorial for ODIN, the Object-oriented Development Interface for NMR

surface Image reconstruction: 2D Fourier Transform

Dynamic Contrast enhanced MRA

Basic principles of MR image analysis. Basic principles of MR image analysis. Basic principles of MR image analysis

Following on from the two previous chapters, which considered the model of the

ACQUIRING AND PROCESSING SUSCEPTIBILITY WEIGHTED IMAGING (SWI) DATA ON GE 3.0T

Module 4. K-Space Symmetry. Review. K-Space Review. K-Space Symmetry. Partial or Fractional Echo. Half or Partial Fourier HASTE

Fmri Spatial Processing

Lucy Phantom MR Grid Evaluation

Enhanced DICOM MR for spectroscopy, structural and functional imaging

Motion Artifacts and Suppression in MRI At a Glance

UNIVERSITY OF SOUTHAMPTON

TOF-MRA Using Multi-Oblique-Stack Acquisition (MOSA)

I.e. Sex differences in child appetitive traits and Eating in the Absence of Hunger:

Module 5: Dynamic Imaging and Phase Sharing. (true-fisp, TRICKS, CAPR, DISTAL, DISCO, HYPR) Review. Improving Temporal Resolution.

Accelerated MRI Techniques: Basics of Parallel Imaging and Compressed Sensing

Clinical Importance. Aortic Stenosis. Aortic Regurgitation. Ultrasound vs. MRI. Carotid Artery Stenosis

MRI Hot Topics Motion Correction for MR Imaging. medical

Outline: Contrast-enhanced MRA

Exam 8N080 - Introduction MRI

Midterm Review

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

Respiratory Motion Compensation for Simultaneous PET/MR Based on Strongly Undersampled Radial MR Data

Table of Contents MRI Neuro protocols

45 µm polystyrene bead embedded in scattering tissue phantom. (a,b) raw images under oblique

A Novel Iterative Thresholding Algorithm for Compressed Sensing Reconstruction of Quantitative MRI Parameters from Insufficient Data

Fundamentals of CT imaging

syngo MR E11 Operator Manual Ortho Answers for life.

Diffusion model fitting and tractography: A primer

Super-resolution Reconstruction of Fetal Brain MRI

Digital Imaging and Communications in Medicine (DICOM) Supplement 167: X-Ray 3D Angiographic IOD Informative Annex

Digital Imaging and Communications in Medicine (DICOM)

The SIMRI project A versatile and interactive MRI simulator *

VXRE Reconstruction Software Manual

7D Cardiac Flow MRI: Techniques & Automation of Reconstruction

Tutorial BOLD Module

M R I Physics Course

FINDING THE TRUE EDGE IN CTA

Sampling, Ordering, Interleaving

Ch. 4 Physical Principles of CT

Sampling, Ordering, Interleaving

T 1 MAPPING FOR DCE-MRI

A Tutorial Guide to Tribology Plug-in

Development and anatomical details of Japanese adult male/female voxel models

A Transmission Line Matrix Model for Shielding Effects in Stents

CTA HEAD Perfusion AqONE without and with IV Contrast

Group analysis of fmri data. Why group analysis? What is a population? Reminder: Analysis of data from 1 person. Robert: Roel Willems,

Advancements in molecular medicine

Transcription:

ADNI, ADNI_QH, SURVEY Geometry Coil selection = Head connection = d Multi coil Homogeneity correction ne FOV (mm) = 250.00 RFOV (%) = 100.00 Foldover suppression Matrix scan = 256 reconstruction = 256 Scan percentage (%) = 50.00 SENSE Stacks = 3 current = A type = parallel slices = 3 slice thickness (mm) = 10.00 slice gap gap (mm) = 10.00 slice orientation = sagittal foldover direction = AP fat shift direction = F use geometry ne Slice scan order Stack scan order = ascend Move table per stack Stack alignment Stack display order PlanAlign REST slabs = 0 Catheter tracking Interactive positioning Allow table movement Patient position = head first orientation = supine Contrast Scan mode = M2D technique = FFE Contrast enhancement = T1 Acquisition mode = cartesian Fast Imaging mode = TFE shot mode = multi-shot TFE factor = 42 startup echoes shot interval = shortest profile order = linear Echoes = 1 partial echo shifted echo TE = shortest Flip angle (deg) = 20.00 TR (ms) = 15.00 Half Scan

Water fat shift Shim SPIR SPAIR TFE prepulse slice selection shared delay ProSet MTC T2prep Research prepulse diffusion mode SAR mode B1 mode gradient mode SofTone mode = maximum = invert = shortest = high = regular Motion Cardiac synchronisation Respiratory compensation Navigator respiratory comp Flow compensation fmri echo stabilisation NSA = 1 Dyn/ang Angio Quantitative flow Manual start Dynamic study Flow labelling ne Postproc Preparation phases B0 field map MIP/MPR Images = 0: M no no no Autoview image = M Reference tissue = White matter Preset window contrast = soft Reconstruction mode = immediate Save raw data Push to workstation Hardcopy protocol Ringing filtering Offc/ang Stacks = 3 current = A Stack Offc. AP (P=+mm) = -20.00 RL (L=+mm) = 0.00 FH (H=+mm) = 0.00 Ang. AP (deg) = 0.00 RL (deg) = 0.00 FH (deg) = 0.00

Info SAR (W/kg) / SAR level = 0.3 / 0 Total scan duration = 00:17.4 Measured voxel size M / P / S (mm) = 0.98 / 1.98 / 10.0 Reconstructed voxel size M / P / S (mm) = 0.98 / 0.98 / 10.0 Actual scan percentage (%) = 49.2 TFE shots = 3 TFE shot duration (ms) / TFE acq duration (ms) = 697.1 / 630.0 TFE shot interval (ms) = 697.1 Minimum prepulse TI delay = 372.8 Act. Water fat shift (pixels) / Act. BW per pixel (Hz) = 1.161 / 187.1 Min. Water fat shift (pixels) / Max. BW per pixel (Hz) = 0.522 / 415.8 Act. TR / TE (ms) = 15 / 5.2 Min. TR / TE (ms) = 10 / 5.2 Relative signal level RSL (%) = 100.0

ADNI, ADNI_QH, MPRAGE_ASO (and MPRAGE_ASO_repeat) Geometry Coil selection = Head connection = d Homogeneity correction ne FOV (mm) = 240.00 RFOV (%) = 100.00 Foldover suppression Matrix scan = 192 reconstruction = 256 Scan percentage (%) = 100.00 SENSE Overcontiguous slices Stacks = 1 slices = 184 slice thickness (mm) = 1.20 slice orientation = sagittal foldover direction = AP fat shift direction = F use geometry ne Chunks = 1 PlanAlign REST slabs = 0 Catheter tracking Interactive positioning Allow table movement Patient position = head first orientation = supine Contrast Scan mode = 3D technique = FFE Contrast enhancement = T1 Acquisition mode = cartesian Fast Imaging mode = TFE shot mode = multi-shot TFE factor = 192 startup echoes shot interval (ms) = 2300.00 profile order = linear turbo direction = Y Echoes = 1 partial echo shifted echo TE (ms) = 4.00 Flip angle (deg) = 8.00 TR = shortest Half Scan Water fat shift = maximum Shim SPIR SPAIR TFE prepulse = invert slice selection

delay (ms) = 1000.00 ProSet MTC T2prep Research prepulse diffusion mode SAR mode = high B1 mode gradient mode SofTone mode Motion Cardiac synchronisation Respiratory compensation Navigator respiratory comp Flow compensation fmri echo stabilisation NSA = 1 Dyn/ang Angio Quantitative flow Manual start Dynamic study Flow labelling ne Postproc Preparation phases B0 field map MIP/MPR Images = 0: M no no no Autoview image = M Reference tissue = White matter Preset window contrast = soft Reconstruction mode = immediate Save raw data Push to workstation Hardcopy protocol Ringing filtering = yes Offc/ang Stacks = 1 Stack Offc. AP (P=+mm) = 0.00 RL (L=+mm) = 0.00 FH (H=+mm) = 0.00 Ang. AP (deg) = 0.00 RL (deg) = 0.00 FH (deg) = 0.00 Info SAR (W/kg) / SAR level = 0.1 / 0 Total scan duration = 09:04.6 Measured voxel size M / P / S (mm) = 1.25 / 1.25 / 1.20 Reconstructed voxel size M / P / S (mm) = 0.94 / 0.94 / 1.20 Actual scan percentage (%) = 100.0

TFE shots = 236 TFE shot duration (ms) / TFE acq duration (ms) = 1833.9 / 1654.7 Minimum prepulse TI delay = 864.3 Act. Water fat shift (pixels) / Act. BW per pixel (Hz) = 1.323 / 164.2 Min. Water fat shift (pixels) / Max. BW per pixel (Hz) = 0.208 / 1041.7 Act. TR / TE (ms) = 8.6 / 4.0 Min. TR / TE (ms) = 8.6 / 3.0 Relative signal level RSL (%) = 100.0

ADNI, ADNI_QH, Double_TSE Geometry Coil selection = Head connection = d Homogeneity correction ne FOV (mm) = 240.00 RFOV (%) = 88.00 Foldover suppression Matrix scan = 256 reconstruction = 256 Scan percentage (%) = 100.00 SENSE Stacks = 1 type = parallel slices = 48 slice thickness (mm) = 3.00 slice gap gap (mm) = 0.00 slice orientation = transverse foldover direction = RL fat shift direction = P use geometry ne Minimum number of packages = 1 Slice scan order PlanAlign REST slabs = 0 Catheter tracking Interactive positioning Allow table movement Patient position = head first orientation = supine Contrast Scan mode = MS technique = SE Modified SE Acquisition mode = cartesian Fast Imaging mode = TSE TSE factor = 10 startup echoes = 0 profile orders DRIVE ultrashort Echoes = 2 partial echo TE first (ms) = 12.00 second (ms) = 96.00 Flip angle (deg) = 90.00 Refocusing control TR (ms) = 3000.00 Half Scan Water fat shift = maximum Shim SPIR

SPAIR BB pulse ProSet MTC Research prepulse Zoom imaging diffusion mode SAR mode B1 mode gradient mode SofTone mode = low = regular Motion Cardiac synchronisation Respiratory compensation Navigator respiratory comp Flow compensation Temporal slice spacing NSA = 1 Dyn/ang Manual start Dynamic study Flow labelling ne Postproc Preparation phases B0 field map MIP/MPR Images = 0: M no no no Autoview image = M Calculated images = 0: no no no no Reference tissue = White matter Preset window contrast = soft Reconstruction mode = immediate Save raw data Push to workstation Hardcopy protocol Offc/ang Stacks = 1 Stack Offc. AP (P=+mm) = 0.00 RL (L=+mm) = 0.00 FH (H=+mm) = 0.00 Ang. AP (deg) = 0.00 RL (deg) = 0.00 FH (deg) = 0.00 Info SAR (W/kg) / SAR level = 1.1 / 0 Total scan duration = 06:45.0 Measured voxel size M / P / S (mm) = 0.94 / 0.95 / 3.00 Reconstructed voxel size M / P / S (mm) = 0.94 / 0.94 / 3.00 Actual scan percentage (%) = 98.2 Number of packages = 3

Minimum slice gap = 3.00 Optimal number of slices = 42 Maximum number of slices = 63 Water fat shift (pixels) / BW per pixel (Hz) = 1.323 / 164.1 TSE echo spacing / shot duration (ms) = 12.0 / 120 Min. TR (ms) = 2201 Relative signal level RSL (%) = 100.0