DesignCon 2005 Track 5: Chip and Board Interconnect Design (5-TA2)

Similar documents
Probing Solutions for Logic Analyzers

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

for Summit Analyzers Installation and Usage Manual

TETRIS 1000 / High Impedance Active Probe Order-No: Features:

Advances in Measurement Based Transient Simulation

Agilent Oscilloscope Probes and Accessories

1.4 mm Pitch High Frequency Differential, Coaxial PCB Probe (40 GHz)

2688 WESTHILLS COURT, SIMI VALLEY, CA

Achieving GHz Speed in Socketed BGA Devices

RiseUp RU8-DP-DV Series 19mm Stack Height Final Inch Designs in PCI Express Applications. Revision Date: March 18, 2005

Over 5,000 products High Performance Adapters and Sockets Many Custom Designs Engineering Electrical and Mechanical ISO9001:2008 Registration

White Paper. Lightweight Connectors for Demanding Applications. June by Brad Taras Product Manager Cinch Connectivity Solutions

Agilent Technologies Connector-based Probes. User s Guide

Logic Analyzer Connectorless Probing Reduces Loading and Footprint Impact on DDR Memory Validation Brock J. LaMeres Agilent Technologies

Product Specification. Mezza-pede SMT Connector Low Profile 1.0mm Pitch

Q Pairs QTE/QSE-DP Final Inch Designs In PCI Express Applications 16 mm Stack Height

Tektronix Logic Analyzer Probes P5900 Series Datasheet

DDR Detective Probing

TETRIS 2500 High Impedance Active Probe. Instruction Manual

N2870A Series Passive Probes and Accessories

intan intan RHD2000 Dual Headstage Adapter RHD2000 Dual Headstage Adapter Features Applications Description TECHNOLOGIES, LLC

GT Micro D High Speed Characterization Report For Differential Data Applications. Micro-D High Speed Characterization Report

ST SPC58 B Line Emulation Adapter System

Adapter Technologies

MIPI D-PHY REFERENCE TERMINATION BOARD (RTB) OVERVIEW AND DATASHEET

07. har-link Interface Connectors

QPairs QTE/QSE-DP Multi-connector Stack Designs In PCI Express Applications 16 mm Connector Stack Height REVISION DATE: OCTOBER 13, 2004

Bolero3M Nexus Emulation Adapter 256BGA 176TQ

SECTION 1 IMP / UMP R107

Revolutionary High Performance Interconnect Which Maximizes Signal Density

N2870A Series Passive Probes and Accessories

Keysight N2870A Series Passive Probes and Accessories. Data Sheet

Board Design Guidelines for PCI Express Architecture

Physics 120/220 Lab Equipment, Hints & Tips

Agilent Technologies N5393A PCI Express Electrical Performance Validation and Compliance Software for Infiniium 54855A or Series Oscilloscopes

Uzebox Kit Assembly Guide

User s Guide. Agilent Technologies Logic Analyzer Probes. (E5378A, E5379A, E5380A, and E5386A) Publication number September, 2002

Using solderless breadboards

Q2 QMS/QFS 16mm Stack Height Final Inch Designs In PCI Express Applications Generation Gbps. Revision Date: February 13, 2009

OSFP Connector Cage & Cable System

DPhy Decoder MIPI 1.5Gb/s Protocol Decoder Hardware DataSheet & User Manual. March Rev 1.0

Addendum for 125B Bushealth Measurements

SPICE Model Validation Report

Agilent Softtouch 2.0 Midbus Probe

JU1 JU6, JU15 JU20. Maxim Integrated Products 1

Package level Interconnect Options

ULTRA2 SCSI WHITE PAPER

Bolero Nexus Emulation Adapter 208BGA 100TQ

Products, Services & Capabilities

DUBOX SHUNTS BOARD/WIRE-TO-BOARD CONNECTORS FEATURES & BENEFITS. Dual-beam contacts for added reliability

High Speed Characterization Report. DVI-29-x-x-x-xx Mated With DVI Cable

Full-chip PRM -RS Customer Board User Guide

MIPI C-PHY REFERENCE TERMINATION BOARD (RTB) OVERVIEW AND DATASHEET

DPhy Preprocessor MIPI 1.5Gb/s Protocol Analyzer Hardware DataSheet & User Manual. February Rev 1.2

Bergstak 0.80mm Pitch Product Presentation

Agenda TDR Measurements Using Real World Products

Next Generation High Density SMT Solderless Edge Card Connector System

Digital Discovery Reference Manual

EVAL-INAMP-62RZ/82RZ/82RMZ

EDA365. DesignCon Impact of Backplane Connector Pin Field on Trace Impedance and Vertical Field Crosstalk

Uzebox Kit Assembly Guide

Implementing Bus LVDS Interface in Cyclone III, Stratix III, and Stratix IV Devices

Scope adapters and probes. Surface mount QFP Logic Analyzer adapters

High-Speed Layout Guidelines for Reducing EMI for LVDS SerDes Designs. I.K. Anyiam

National Semiconductor Application Note 1115 John Goldie July FIGURE 2. Device Configurations

PC/104, PC/104 Plus Specification

AN-1055 APPLICATION NOTE

Open NAND Flash Interface Specification: NAND Connector

Integrating ADS into a High Speed Package Design Process

AXOMACH E-16. High data rate links for faster data transmission. Microwave coaxial cables. Panel mount connector QUASI-FLEX. Cable mount connector 2

Differential Probes TDP1500 TDP3500 Data Sheet

Addressable Bus Buffer Provides Capacitance Buffering, Live Insertion and Nested Addressing in 2-WireBus Systems

DM9051NP Layout Guide

Application Suggestions for X2Y Technology

HD Series. Signal Connector DIN Applicable Markets: Mil-Aero Space Marine

A Modular Platform for Accurate Multi- Gigabit Serial Channel Validation

Symbol Parameter Min Typ Max VDD_CORE Core power 0.9V 1.0V 1. 1V. VDD33 JTAG/FLASH power 2.97V 3.3V 3.63V

PC Board Sockets. Specifications SOCKETS. Surface Mount, Single Piece construction. Throughboard, Two Piece construction. Materials.

BOARD-TO-BOARD HEADERS & RECEPTACLES

Make sure that the MUTE button on your phone is depressed during the voice explanations.

SFC ChipClamp ΤΜ Flip Chip TVS Diode with T-Filter PRELIMINARY Features

1000 Base-T, ±15kV ESD Protection LAN Switch

U4421A MIPI D-PHY Protocol Analyzer and Exerciser. Hardware and Probing Guide

VMEbus systems System description Technical characteristics System description

I N T E R C O N N E C T A P P L I C A T I O N N O T E. Z-PACK TinMan Connector Routing. Report # 27GC001-1 May 9 th, 2007 v1.0

Advance Concept Release for. Initial Pre-Production Sampling Only. Device Bay Connector System

DCN23 Digital Crossover with 2 inputs and 3 outputs

Features. Applications

Magnetic probe holders are fully adjustable for more DUT heights and probe styles

CARDINAL COMPONENTS, INC.

PCI Express Gen 4 & Gen 5 Card Edge Connectors

Agilent InfiniiMax III probing system

CIRCUIT DESIGN. is published monthly by: UP Media Group Inc Powers Ferry Road, Ste. 600 Atlanta, GA Tel (678) Fax (678)

High-Performance Differential Probes P7350 P7330 P6330 Datasheet

Getting Started. 1.3 X-MWsystem Vocabulary. X-MWprobe X-MWanchor X-MWjumper. X-MWblock RF. X-MWblock Bias and Control. X-MWprotoplate X-MWwall X-MWlid

PDS: Rev :A STATUS:Released Printed: Jan 04, 2012

National Semiconductor EVK User Manual

MP3 audio amplifier. Build Instructions. Issue 2.0

1999 High Performance Systems Design Conference

2:1 MULTIPLEXER CHIP FOR PCI-EXPRESS ICS Description. Features. Block Diagram DATASHEET

Transcription:

DesignCon 2005 Track 5: Chip and Board Interconnect Design (5-TA2) Connector-Less Probing: Electrical and Mechanical Advantages Authors/Presenters: Brock LaMeres, Agilent Technologies Brent Holcombe, Agilent Technologies George Marshall, Precision Interconnect

Objective 1) Describe Differences between Connector-less and Connector-Based Probing 2) Aid in Selection of Logic Analyzer Probe Connector-less Probing: Electrical and Mechanical Advantages Page 2

The Logic Analyzer A logic analyzer is a piece of general purpose, test equipment It provides debug/validation for digital systems It is connected to the target system using a probe Connector-less Probing: Electrical and Mechanical Advantages Page 3

The Probe Provides the electrical connection from the target to the analyzer Provides the mechanical connection from the target to the analyzer Both are important factors in selecting a probe Connector-less Probing: Electrical and Mechanical Advantages Page 4

Probe Theory The Probe Passively Observes the Target Signal A Small Amount of the Target Signal Enters the Probe The Logic Analyzer Amplifies this Signal to see the Original Waveform Connector-less Probing: Electrical and Mechanical Advantages Page 5

Probe Theory The Probe Can Be Thought of as a Resistive Divider Network Divider Ratio Connector-less Probing: Electrical and Mechanical Advantages Page 6

Probe Theory The Goals of the Probe are to: 1) Do Not Disturb the Target Signal 2) Accurately Represent the Original Signal Within the Analyzer Connector-less Probing: Electrical and Mechanical Advantages Page 7

Probe Implementation The physical implementation dictates probe performance Tip Resistor - Discrete SMT - Discrete Coaxial Cable -Coax -Twisted Pair Termination/Amp -Custom Circuitry Interconnect -Wires - Connectors -Springs Connector-less Probing: Electrical and Mechanical Advantages Page 8

Probe Loading What does the user need to be concerned about? 1) DC Loading The Probe Tip 2) AC Loading 3) Meeting Analyzer Specs at Probe Tip Connector-less Probing: Electrical and Mechanical Advantages Page 9

Probe Loading What does the User Need to be concerned about? 1) DC Loading - dictated by Tip Resistor value DC 500Mb/s = 100MΩ s (less DC Loading) > 500Mb/s = 20kΩ s (more DC Loading) Connector-less Probing: Electrical and Mechanical Advantages Page 10

Probe Loading What does the User Need to be concerned about? 2) AC Loading- dictated by Interconnect & Location on Bus Further from Target = More Capacitive Loading (stubs) Poor Bus Location = Distorted Waveform (analyzer failures) Connector-less Probing: Electrical and Mechanical Advantages Page 11

Probe Loading What does the User Need to be concerned about? 3) Meeting Analyzer Specs at the Probe Tip Defined WITH PROBE CONNECTED!!! Depends on Loading and Location on Bus Connector-less Probing: Electrical and Mechanical Advantages Page 12

Traditional Probing Probing Methodologies 1) Designed-In - User Plans Ahead - Places Footprint on Target - Routes Signal of Interest to Footprint ex) High-Density Connectors Pin-Header Strips Connector-less Probing: Electrical and Mechanical Advantages Page 13

Traditional Probing Probing Methodologies 2) After-Thought - Signal NOT routed to test pad ex) Solder Down Accessories, Grabbers, Browsers Connector-less Probing: Electrical and Mechanical Advantages Page 14

Traditional Probing Limitations 1) Physical Interconnect Loading - Electrical and Mechanical Connection are the Same which increases size - Increased Size means more loading (L and C) Connector-less Probing: Electrical and Mechanical Advantages Page 15

Traditional Probing Limitations 2) Designed In Connectors Block Routing - Connector Holes are Often Obtrusive to Flow-Through Routing - Connectors are placed off to the side and stubs are used to connect Connector-less Probing: Electrical and Mechanical Advantages Page 16

Traditional Probing Limitations 3) Tip Resistor is Far from Target - Increased Capacitive Loading (Stub) Connector-less Probing: Electrical and Mechanical Advantages Page 17

Connector-Less Probing Probing Methodology 1) Small Test Pads are Placed on the Target - Signals of interest are routed to the pads Connector-less Probing: Electrical and Mechanical Advantages Page 18

Connector-Less Probing Probing Methodology 2) A Retention Module is Hand Soldered to the PCB - The RM pins are the Mechanical Connection ONLY Topside Or Bottomside Solder Connector-less Probing: Electrical and Mechanical Advantages Page 19

Connector-Less Probing Probing Methodology 3) Attach Compression Probe to RM - The compression interconnect contacts the pads - The RM aligns and retains the interconnect - The compression interconnect is the Electrical Connection ONLY Connector-less Probing: Electrical and Mechanical Advantages Page 20

Connector-Less Probing: Electrical Advantages 1) Reduced Loading - The physical size is smaller than a connector - The Mechanical and Electrical Connections are Separate Loading: 3pF <0.7pF Datarate: 600Mb/s >2.5Gb/s Connector-less Probing: Electrical and Mechanical Advantages Page 21

Connector-Less Probing: Electrical Advantages 2) Flow-Through Routing - The Small Test Pads Allow Signals to route through the footprint - No Stubs Needed - Differential Spacing Preserved Connector-less Probing: Electrical and Mechanical Advantages Page 22

Connector-Less Probing: Electrical Advantages 3) Tip Resistor is Closer to the Target Signal - Reduced loading due to parasitic stub Loading: 3pF <0.7pF Datarate: 600Mb/s >2.5Gb/s Connector-less Probing: Electrical and Mechanical Advantages Page 23

Connector-Less Probing: Electrical Advantages Connector-Based vs. Connector-Less (Mictor vs. SoftTouch) - SPICE Simulation of Reflections from Probe -50Ω System - Double Terminated - Probing in Middle of Bus TDR SPICE Simulation Rise time = 175ps = 2GHz Rise time = 117ps = 3GHz Rise time = 88ps = 4GHz Rise time = 70ps = 5GHz Rise time = 58ps = 6GHz Connector-less Probing: Electrical and Mechanical Advantages Page 24

Connector-Less Probing: Electrical Advantages Connector-Based vs. Connector-Less (Mictor vs. SoftTouch) - SPICE Simulation of Transmission Degradation from Probe -50Ω System - Double Terminated - Probing in Middle of Bus TDT SPICE Simulation Rise time = 175ps = 2GHz Rise time = 117ps = 3GHz Rise time = 88ps = 4GHz Rise time = 70ps = 5GHz Rise time = 58ps = 6GHz Connector-less Probing: Electrical and Mechanical Advantages Page 25

Connector-Less Probing: Electrical Advantages Connector-Based vs. Connector-Less (Mictor vs. SoftTouch) - SPICE Simulation of Differential Separation Caused from connector-based probe -100Ω System - Double Terminated - Probe in Middle of Bus -PC5 ustrip Decoupled for 1 TDT SPICE Simulation Impedance Mismatch due to Uncoupling of Diff Pair Connector-less Probing: Electrical and Mechanical Advantages Page 26

Connector-Less Probing: Electrical Advantages Connector-Based vs. Connector-Less - Historical View First Logic Analyzer 3M 40-pin 3pF loading 500Mb/s Mictor 3pf loading 600Mb/s Samtec 1.5pf loading 1500Mb/s Soft Touch <0.7pf loading >2500Mb/s Flying Leads 0.9pf loading 1500Mb/s ½ Size Soft Touch <0.7pf loading >2500Mb/s Soft Touch Pro <0.7pf loading >2500Mb/s 1973 1985 1996 2000 2003 2004 Industry Standard Footprint Industry Standard Footprint Connector-less Probing: Electrical and Mechanical Advantages Page 27

Connector-Less Probing: Mechanical Advantages 1) Ease of Assembly 2) Mechanical Reliability 3) Post-Production Probing Connector-less Probing: Electrical and Mechanical Advantages Page 28

Connector-Less Probing: Mechanical Advantages 1) Ease of Assembly RM is hand-soldered No Machine Loading Needed Connector-less Probing: Electrical and Mechanical Advantages Page 29

Connector-Less Probing: Mechanical Advantages 2) Mechanical Reliability Spring-Pin Interconnect outperforms Standard Connectors Planarity Contamination Connector-less Probing: Electrical and Mechanical Advantages Page 30

Connector-Less Probing: Mechanical Advantages 3) Post Production Probing RM can be hand-loaded on production units Connector-less Probing: Electrical and Mechanical Advantages Page 31

So, what do these advantages mean to you??? Connector-Less Probes save you: Debug capability in high volume production PCB s is FREE! No rework cost for damaged debug connectors Longer life out of Connector-Less probe adapters Debug PCB s in the field for much lower cost Connector-less Probing: Electrical and Mechanical Advantages Page 32

Summary 1) Connector-Less is the latest Technology in Logic Analyzer Probing 2) Connector-Less Probing has Improved Electrical Characteristics - Lower Loading, Faster Analyzer Datarates, Cleaner Routing of Signals 3) Connector-Less Probing has Improved Mechanical Characteristics - No Connector on Target PCB, Easy Attachment, Reliability, Cost Savings Connector-less Probing: Electrical and Mechanical Advantages Page 33

Questions? Connector-less Probing: Electrical and Mechanical Advantages Page 34