K33-BLG/ELG Sensor module for environment logging Data Sheet and Manual

Similar documents
Datasheet: K-33 BLG Sensor

Product Specification. CO 2 Engine ICB. Sensor module for bio applications

Product Specification. CO 2 Engine K33-LP T. Sensor Module and OEM Platform. Document PSP0120. Rev 4. Page 1 (13)

Gas and Air Sensors. Product Specification. CO 2 Engine K30. Sensor Module and OEM Platform. Document PSP 110. Rev 4. Page 1 (11)

Product Specification. Sensor Module and OEM Platform

an ISO9001/14001 company

Product Specification. CO 2 Engine K30 STA. Sensor Module and OEM Platform

The CO 2 Engine Infrared Gas Sensing For OEM Applications

Product Specification. tsense VAV. CO 2 -, Temperature- and RH- sensor in a housing with colour touch display

Product Specification. Senseair LP8. Miniature CO 2 sensor module for battery-powered applications

The unit is designed for connecting to Direct Digital Control (DDC). The linear output functions are pre-programmed as CO 2

2F. No.25, Industry E. 9 th Rd., Science-Based Industrial Park, Hsinchu, Taiwan

PCD DIGITAL Differential pressure probe

C7110C1001A / C7110D1009A WALL MODULES

General. Copyright 2013 EXSEN Company. All Rights Reserved. Rev /5/2013 Page 1 of 6

tsense (Disp) T RH RL

AQS51/61-KAM COMBINED CO 2 -/TEMPERATURE DUCT SENSOR/CONTROLLER

Manual iaq-core Indoor Air Quality sensor module

Schneider Electric s SCD series of duct mount sensors measure the levels of CO 2. , RH (if equipped) and temperature of air inside a duct.

Modbus on CO 2 Engine and esense

Modbus on K45 asense. Table of contents:

MH-Z16 Intelligent Infrared Gas Module

2001VT Temp & CO 2. - air quality sensor/controller NOTE!!! Manual for Installation. General. SenseAir AB

Manual iaq-engine Indoor Air Quality sensor

Trueyes Inc. Carbon Dioxide (CO2) Module

Rev Carbon Dioxide (CO2) Gas Sensor. TG100 User Manual

TOXALERT MODEL AIR 2000

HygroClip DIGITAL Humidity and temperature probe

Piccolo2-OEM Fiber-optic Version (Item nr. PICO2-OEM)

ZG07 CO2 Module. ZG07 series CO2 Module. User Manual

Modbus on SenseAir S8

USB-1208LS Specifications

RN-174. WiSnap M2 Super Module. Features. Description. Applications. ~ page 1 ~ rn-174-ds v1.1 6/1/2011

T67xx C0 2 Sensor Module Application Note

RN-174. WiFly GSX Super Module. Features. Description. Applications. rn-174-ds v1.1 4/20/2011

Real Time Clock with Temperature Sensor and RS485/Modbus Comunications

tsense User Manual CO 2 -, temperature- and relative humidity transmitter Gas and Air Sensors

Model 305e OEM CO 2 concentration sensor

RN-174 WiFly Super Module

Rev Carbon Dioxide (CO2) Gas Sensor. TG100 User Manual

Humidity Temperature Transmitter User Guide

ZG01 CO2 Module. ZG01 CO2 Module. User Manual

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

Digital Humidity & Temperature Sensor. With Two-Wire Interface

NPA 201. Amphenol Advanced Sensors. Digital Output Absolute Pressure Sensor. 11:15 17 Jan,15. Applications. Features

Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT

WBI Series Mass flow sensors for gases

Carbon Dioxide Monitor/Controller With The USB Data Logger

RN-174. WiFly GSX Super Module. Features. Description. Applications. rn-174-ds v1.1 3/3/2011

HTD series digital differential pressure sensors

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information. Display. Supply voltage. Input current

Specification Sheet For electronically commutated motors

VINCULUM-BASED TEMPERATURE / HUMIDITY / VOLTAGE DATA LOGGER FEATURES:

Specifications minilab 1008

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

General information. Display. Supply voltage. Input current. Encoder supply. Output current

User Manual for TeraRanger Evo with: USB and I2C/UART backboard

Specifications

CDD4 Duct Carbon Dioxide Transmitter

8 CHANNEL ANALOG DATA LOGGER

HygroFlex HF3 Transmitters. User Guide

CDD Carbon Dioxide Transmitter

1. Features and Benefits

User Manual for. TeraRanger Evo with: USB and I2C/UART backboard

HOBO External Temp/RH Data Logger (UX ) Manual

Before powering on your driver, read this manual thoroughly. If you have any doubt or suggestion, please do not hesitate to contact us!

Chapter 1 Introducing the OM-USB Functional block diagram... 5

BMKC Controller for Parabolic Trough application without encoder, 8 In 8 Out 4 AI

Specifications USB-1408FS

Environdata FA ma Converter Guide

LGR-5325 Specifications

HOBO Temp/RH 3.5% Data Logger (UX ) Manual

Specification of JBT Mesh Bluetooth Module

BMKC Controller for Parabolic Trough, 8 DI 12 DO 4 AI

General information. Display. Supply voltage

User Manual for TeraRanger Evo single point distance sensors and backboards

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current

Output signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V

last update December 1, 2010 reference smtirin06n page 1/21 SMARTEC INFRARED INTERFACE BOARD SMTIRIN06

EE80 Series. HVAC Room Transmitter and Switches for CO 2, Relative Humidity and Temperature EE80. Applications. Typical

Modbus on S8. Modbus is a simple, open protocol for both PLC and sensors. Details on Modbus can be found on

General information. Display. Supply voltage. Input current. Encoder supply. Output current

User Manual for TeraRanger Evo single point distance sensors and backboards

TouchCore351-ML16IP. Capacitive Touch Sensor Controller

Modbus on S8. Modbus is a simple, open protocol for both PLC and sensors. Details on Modbus can be found on

General information. Display. Supply voltage. Input current. Encoder supply. Output current

User Guide. Indoor Air Quality Meter/Datalogger. Model EA80

Temperature and humidity module DHT11 Product Manual

DGS-NO August 2017

HygroFlex HF3 Transmitters and Thermohygrostats: User Guide

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

manufactured by SF8150-ZIF14

SX100A. Features. Typical Applications. Description

Atmos Engineering, Inc. External Specification PN PC104 Air Data Atmodule PN Revision 6.0

Intelligent Infrared CO 2 Gas Sensor. (Model: MH-711A) Manual. Version: 3.3. Valid from: May 1st, 2014

Transcription:

K33-BLG/ELG Sensor module for environment logging Data Sheet and Manual General CO 2Engine -ELG (left) and CO 2Engine -BLG (right) SE-0020 K-33 ELG Sensor CM-0026 K-33 ELG Devkit SE-0027 K-33 BLG Sensor CM-0025 K-33 BLK DevKit This document describes a family of sensor modules CO 2Engine - BLG/ELG designed to measure and store records of environmental parameters such as - Temperature - Relative Humidity - CO2 concentration ELG up to 5,000ppm range, BLG up to 30% The sensor module is designed for long-life with low average power consumption without compromising measurement precision and resolution. Virtual Real Time Clock allows data and events logging with time stamps. Events include sensor power on, logging start/stop, ABC self calibration, user initiated zero and background calibrations. I 2 C or UART communication can be used to read logged data for built in modules. Rev. 9 August 2017

Use scenario CO 2Engine - BLG/ELG CO 2 Engine - BLG/ELG is a sensor module for CO2 concentration, temperature and relative humidity. Sensirion s SHT11 Temperature / RH sensor is installed on the board to measure temperature and relative humidity. There are three ways to activate measurement/logging - Jumper (set AnIn1 high) After power-on, sensor checks jumper presence, if jumper is not present (low level on input, AnIn1), sensor goes into sleep mode. If jumper is set (high level at input), sensor sleeps a predefined time (configured in EEPROM) and then start the measurement sequence. After measurement has been started the sensor wakes up periodically, makes measurements, stores result in on board nonvolatile memory (if logger is activated) and goes into sleep mode until next measurement. - Command Force start measurement Another way to start/stop measurements is with the commands Force Start Measurements and Force Stop Measurements, the sensor will act in the same way as if the jumper was set/reset. - Command Single measurement If only one measurement is desired the command Single measurement can be sent to the sensor. Then the sensor will measure once, store result in on board non-volatile memory (if logger is activated) and go back to sleep mode. For correct timestamps sensors RTC has to be set after the sensor in powered. User can read logged data via serial port (UART with standard SenseAir cable) alternatively I2C-to-USB bridge. For correct timing it is important that RTC is set after battery is inserted. Figure 2 CO 2Engine -BLG powered via Vbat+ Page 2 of 11

Drawings below show battery connection (with polarity) to the sensor (Vbat+), pin assignment of UART and I 2 C communication connectors. Zero calibration Start logging jumper (AnIn1) Background calibration Figure 3 CO 2Engine -BLG/ELG powered via Vbat+ and data read via UART terminal. Analogue GND I2C_SDA I2C_SCL G+ G0 DVCC = 3.3V Digital GND Figure 4 CO 2Engine -BLG with I 2 C terminal. Page 3 of 11

Terminal descriptions Table below specifies what terminals and I/O options are available in the general K33 platform (see also the layout picture Fig 3). Functional group Power supply G0 G+ Referred to G0: Vbat+ Referred to G0: Communication UART (UART_TxD, UART_RxD) Descriptions and ratings Power supply minus terminal Sensor s reference (ground) terminal Power supply via protection circuit. Protected by series 3.3R resistor and zener diode Absolute maximum ratings 5.5 to 12V, stabilized to within 10% Power supply directly to the system without protection circuit. Absolute maximum ratings 4.75 to 12V, stabilized to within 10% Unprotected against reverse connection! CMOS physical layer, ModBus communication protocol. (refer Modbus on CO2 Engine and esense rev2_00.pdf or later version for details) UART_RxD line is configured as digital input. Input high level is 2.1V min Input low level is 0.8V max UART_TxD line is configured as digital output. Output high level is 2.3V (assuming 3.3V DVCC) min. Output low level is 0.75V max UART_RxD input is pulled up to DVCC = 3.3V by 56 kohm UART_TxD output is pulled up to DVCC = 3.3V by 56 kohm ABSOLUTE MAX RATING G0-0.5V.. DVCC + 0.5V I2C extension. (I2C_SCL, I2C_SDA) Pull-up to DVCC = 3.3V. (refer I2C comm guide 2_10.pdf or later version for details) ABSOLUTE MAX RATING G0-0.5V.. DVCC + 0.5V Continuation on the next page Page 4 of 11

Functional group Descriptions and ratings Digital I/Os, used as Inputs in standard configuration. May be implemented as jumper field Din0 Digital switch inputs in standard configuration, Din1 Pull-up 56k to DVCC 3.3V. Driving it low or connecting to G0 Din2 activates input. Din3 Pull-up resistance is decreased to 4..10k during read of input or jumper. Advantages are lower consumption most of the time the input/jumper is kept low and larger current for jumpers read in order to provide cleaning of the contact. AnIn1 Din1 used for background calibration. Din2 used for zero calibration. Input set to DVCC activates measurement/logging cycle, input released (or held low) set sensor into sleep, in sleep mode sensor check AnIn1 and support communication. Table I. I/O notations used in this document for the K33 platform with some descriptions and ratings. Please, beware of the red colored texts that pinpoint important features for the system integration! Page 5 of 11

General PCB overview Figure 5 CO 2Engine -BLG/ELG I/O notations and terminals Figure 6 CO 2Engine -BLG/ELG edge connecto,( seen from component side) Page 6 of 11

CO 2 Engine BLG/ELG Default appearance technical specification General Performance: Storage Temperature Range... -40 to +70 C, Storage Environment... Non condensing, non corrosive environment 2 Operating Temperature Range... 0 to 50 C Operating Humidity Range... 0 to 95% RH (non-condensing) 1 Operating Environment... Non corrosive environment 2. Residential, commercial, industrial spaces used in... HVAC (Heating Ventilation and Air-Conditioning) systems. 4 Sensor Life Expectancy... > 10 years Maintenance Interval... Maintenance-free. See discussion of ABC algorithm on page 10. Self-Diagnostics... complete function check of the sensor module Conformance with the standards... RoHS directive 2002/95/EG Electrical / Mechanical: Power Input... 6-12 VDC 3 max rating, stabilized to within 10% powering sensor via Vbat+ 6-14 VDC 3 max rating, stabilized to within 10% powering sensor via G+ (on board protection circuits) Current Consumption... ~250μA (1 measurement/hour)... ~50μA in sleep ~60 ma average during active measurement sequence (~12s) < 150 ma peak current (averaged during IR lamp ON, 100 msec) < 250 ma peak power (during IR lamp start-up, the first 50 msec) for maximum operating time (if powered by batteries), choose batteries that can deliver 250mA pulses without large voltage drops (for example batteries recommended for cameras) Electrical Connections... Vbat+, G+ and G0 Dimensions... 51 x 57 x 14 mm (Length x Width x Height) for BLG (0..30% measurement range)... 51 x 57 x 12 mm (Length x Width x Height) for ELG (0..5000ppm measurement range) CO 2 Measurement: Sensing Method... non-dispersive infrared (NDIR) waveguide technology with ABC, automatic background calibration algorithm (application specific) Sampling Method... diffusion Response Time (T 1/e )... <25 sec gas diffusion time Measurement period... 5 min to 0.5 year interval, a measurement period less than 5 min can be used, but then specified accuracy on RH and temperature measurements are not guaranteed ELG, CO2 module 0..5000ppm: Repeatability... ± 20 ppm ± 1 % of measured value Accuracy 5... ± 30 ppm ± 3 % of measured value BLG, CO2 module 0..30% vol : Repeatability... ± 0,1 %vol. CO2 ± 2 % of measured value Accuracy 5... ± 0,2 %vol. CO2 ± 3 % of measured value Pressure Dependence... + 1.6 % reading per kpa deviation from normal pressure, 100 kpa On-board calibration support... Din1 switch input to trigger Background Calibration @ 400 ppm (0.04%vol) CO2 Din2 switch input to trigger Zero Calibration @ 0 ppm CO2 Note 1: Sensors are 100% tested in production at 45C / 85%RH / 1000ppm CO2 for one hour. For applications operating continuously in high humidity, contact SenseAir for further information. Note 2: SO2 enriched environments are excluded. Note 3: Notice that absolute maximum rating is 12V, so sensor can not be used with 12V+-10% supply. Note 4: Different options exist and can be customized depending on the application. Please, contact SenseAir for further information! Note 5: Accuracy is specified over operating temperature range at normal pressure 1013 mbar. Specification is referenced to certified calibration mixtures. Uncertainty of calibration gas mixtures (+-2% currently) is to be added to the specified accuracy for absolute measurements. Page 7 of 11

CO 2 Engine BLG/ELG - Default appearance technical specifications (continued) Temperature Measurement: Sensor SHT11 from Sensirion (www.sensirion.com) Measurement Range...-40 to 60C Accuracy 6,7... ± 0.4C at 25C Relative Humidity Measurement: Sensor SHT11 from Sensirion (www.sensirion.com) Measurement Range... 0 to 100% RH non condensing Accuracy 6,7... ± 3% RH Logger properties: Logger Capacity... 5400 logging points if CO2 concentration, temperature and relative humidity are logged (with timestamp). Logging Data... Selectable, one data record can contain up to 14 bytes (max 4 variables) Logging Period... (1 255) * Measurement Period. Delay since setting jumper... 0 to 255 seconds (5s in default configuration) Note 6: Specification is provided by Sensirion. Note 7: Minimum 5 minutes measurement period. Page 8 of 11

Maintenance The models based on CO 2Engine K33 platform are basically maintenance free in normal environments thanks to the built-in self-correcting ABC algorithm. ABC algorithm The default sensor OEM unit is maintenance free in normal environments thanks to the built-in self-correcting ABC algorithm (Automatic Baseline Correction). This algorithm constantly keeps track of the sensor s lowest reading over a predefined period and slowly corrects for any long-term drift detected as compared to the expected fresh air value of 400 ppm CO 2. Since timing (time between measurements) can be configured in BLG/ELG it is important to make sure that the sensor has possibility to measure fresh air during the predefined period. It is recommended that ABC configuration is optimized for its tasks during a dialog between SenseAir and the OEM customer. In default configuration for BLG/ELG sensors ABC is switched off. Calibration Rough handling and transportation might, result in a reduction of sensor reading accuracy. For post calibration convenience, in the event that one cannot wait for the ABC algorithm to cure any calibration offset, two switch inputs Din1 and Din2 are defined for the operator to select one out of two prepared calibration codes. If Din1 is shorted to ground during a measurement cycle (flashing lamp), the internal calibration code bcal (background calibration) is executed, in which case it is assumed that the sensor is operating in a fresh air environment (400 ppm CO 2). If Din2 is shorted instead during a measurement cycle (flashing lamp), the alternative operation code zcal (zero calibration) is executed in which case the sensor must be purged by some gas mixture free from CO 2 (i.e. Nitrogen or Soda Lime CO 2 scrubbed air). Make sure that the sensor environment is steady and calm during calibration! Input Switch Terminal (normally open) Din1 Default function (when closed for minimum 8 seconds) bcal (background calibration) assuming 400 ppm CO2 sensor exposure Din2 zcal (zero calibration) assuming 0 ppm CO2 sensor exposure Table II. Switch input default configurations for CO 2Engine K33 Page 9 of 11

Self-diagnostics The system contains complete self-diagnostic procedures. A full system test is executed automatically every time the power is turned on. In addition, constantly during operation, the sensor probes are checked against failure by checking the valid dynamic measurement ranges. All EEPROM updates, initiated by the sensor itself, as well as by external connections, are checked by subsequent memory read back and data comparisons. These different system checks return error bytes to the system RAM. If this byte is not zero, the logic output terminal Status will be put into Low level state. The full error codes are available from the UART port or via I 2 C communication. Offset regulation error and Out of Range are the only bits that are reset automatically after return to normal state. All other error bits have to be reset after return to normal by UART/I2C overwrite, or by power off/on. Error code and action plan (error code can be read via one of communication channels) Bit # Error Error description Suggested action code 0 1 Fatal Error Try to restart sensor by power OFF/ON. Contact local distributor. 1 2 Offset regulation error Try to restart sensor by power OFF/ON. Contact local distributor. 2 4 Sensirion com error Try to restart sensor by power OFF/ON. Unable to communicate with Sensirion Check detailed settings and configuration (Temp/RH) sensor. with software tools. Contact local distributor. 3 4 16 DetTemp out of range. Indicate high (out of range) detector temperature. 5 32 CO2 out of range Indication of high (out of range) CO2 level. 6 64 Memory error Error during memory operations. 7 128 Sensirion space temp out of range Table III. Switch input default configurations for CO 2Engine K33 Remark: If several errors are detected at the same time the different error code numbers will be added together into one single error code! Page 10 of 11

Frequently asked Questions - Programming 1- If I send the stop command, Is it only the CO2 measurement process that is stopped, or is the sensor not going to respond to any other request except a start measurement request? When receiving a stop command sensor finishes its present task and goes into sleep mode (to minimize current consumption), in sleep mode sensor wakes up periodically (1s) and for example check the jumper, activity on the communication lines will also wake up the sensor (see I2C communication guide for details). 2- If I stop the measurement, are all the other functions still active, can I still read/write from the sensor? Can I still read the last CO2 value and temperature while the sensor is stopped? Yes, communication is possible after stop measurement. 3- When a start measurement CMD is sent, what is the delay to the effective start of the measurement process (how much time after is the sensor normally starting to hold the bus CLK)? Standard time to measurement is 1 minute (same for start measurement command and jumper set), measurement sequence takes ~20s 4- How quickly (immediately?) after the end of the bus hold can I send a stop command? (or is it better to leave the sensor running for a minimum delay?) It is recommended to wait until after measurement sequence has finished and you have read new data before sending stop command (~80s) 5- Should the light stop flashing when the stop measurement command is sent? Not immediately, sensor will finish ongoing measurement sequence before going to sleep stop measuring. Page 11 of 11