SSW7. User Manual. Adapter for MPI-Bus. Version:2 / HW: 1 / FW: 3.0 and higher. Order number of manual: VK21/en VK21

Similar documents
SSW7-RK512/RS422. Adapter for MPI Bus with RK512 Protocol, RS VK21. User Manual. Version: 1 / HW: 1 / FW: 2.

SSW5/USB. S5-PLC to USB converter cable US US13. User Manual. Edition 2 / / HW1 and higher

SSW7-USB. User Manual VK21. Edition 3 / HW 6a and FW 3.29 and higher. Order number of manual: VK21/en

CAN-Bridge. CAN Communications Module for CAN 2.0 A/B, CAN Layer AA01. Manual. Version 1/ from HW 1 & FW 1.00

Quick Start Guide PN/CAN Gateway Layer 2. Version. 2 en. ab FW

MPI-BUS. Programming Adapter PPI-Cable Accessory RK512- and HMI-Adapter

Quick Start Guide PN/CAN-Gateway. Version. 1 en. from FW

Brief instruction. Version. 3en.

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Manual. CAN 300 PRO CANopen Slave. CAN Communication Modules for S7-300 as CANopen Slave. Edition 3 /

NETL ink gateways. Ethernet gateways WLAN gateways High-speed USB gateways

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

Manual Industry Interfaces

Quick Start Guide NETL ink Ethernet Gateways

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

Manual Fiber Optic Interfaces

MGate 4101-MB-PBS Series

Features and Benefits. Certifications

Manual. VIPA Accessories USB-MPI adapter 950-0KB31. Order No.: VIPA HB158E_PC-AG Reference: RE_950-0KB31 Rev. 08/25

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

PAS 300, PROFIBUS Slave Interface Module

Product Manual. Single Port RS-232 USB Serial Adapter Optical- ISO Surge Protection. Coolgear, Inc. Version 1.1 March 2018 Model Number: USB-COM-Si-M

USB-COM Plus ISO (USB-COMi SI-M)

Media Converters. Media Converters. Product Selection Guides

3.1 I-7560 Pin Assignment and Specifications: Introduction

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

Quick Start Guide WALL IE. Version. 7 en. as of FW

I-7560U/7561U/7563U. User Manual WARRANTY WARNING COPYRIGHT TRADEMARKS CONTACT US

ELAN DIGITAL SYSTEMS LTD. CF232 COMPACT FLASH CF+ CARD USER S GUIDE

IDS-141A/181A. Industrial 4-port/8-port slim type serial to Ethernet device server. Features. Introduction. DS-Tool

Quick Start Guide PROFINET Switch 4/8-port. Version. 1en.

General information. Display. Supply voltage. Input current

Application. Characteristics RTU540. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Product Manual. USB BAY-4 Port Serial DB- 9 RS-232 Adapter with FTDI Chipset. Coolgear, Inc. Version 1.1 September 2017 Model Number: USBG-BAY4

General information. Display. Supply voltage. Input current

Arm-based palm-sized industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits. Certifications

General information. Display. Supply voltage

MEC-COM-M134. User s Manual

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

General Operating, Maintenance and Installation Manual

ELAN DIGITAL SYSTEMS LTD.

FL SWITCH SFN 5TX. Extract from the online catalog. Order No.:

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

General information. Display. Supply voltage

DI572 Digital Input Module

Whitepaper. IPSec Client/Router. Version /1/2016

Feature and Benefits. Certifications

Brief Instruction. 4.2 ISDN devices. 4.2 GSM devices MDH 502 MDH 536 MDH 506 MDH 512 MDH 542 MDH 522

1 to 16-port RS-232, RS-422/485, and RS-232/422/485 USB-to-serial converters. Features and Benefits. Certifications

Channel Switch CS. General Operating, Maintenance and Installation Manual

General information. Display. Supply voltage. Input current. Encoder supply. Output current

DI561 Digital Input Module

Appendix. Specifications

NetCom Plus 113 (NetCom 113, NetCom 113 PRO)

USB-4COM RJ45. Contact Online. More Pictures. Click on the thumbnails for the large picture. Overview

NetCom Plus 111 (NetCom 111)

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Features and Benefits. SNMP MIB-II for network management. Certifications

General information. Display. Supply voltage. Input current. Encoder supply. Output current

PCAN-MicroMod Analog 1 Application-specific PCAN-MicroMod Motherboard. User Manual. Document version ( )

ME-9000i isolated Serial Interface Board, RS232, RS422, RS485

AI561 Analog Input Module

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

PCAN-MicroMod Digital 1 & 2 Application-specific PCAN-MicroMod Motherboard. User Manual V1.10.0

General information. Display. Supply voltage. Input current

TRP-C08M. USB To 4 RS232/422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.0

PCAN-MicroMod Analog 2 Application-specific PCAN-MicroMod Motherboard. User Manual. Document version ( )

General information. Display. Supply voltage. Input current. Encoder supply. Output current

TRP-C08S. USB To 1* RS232 and 1*RS422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.2

General information. Display. Supply voltage. Input current. Encoder supply. Output current

PCIe-400 USER S MANUAL

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

Operating Instructions SECUTEST SI /12.10

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

AO561 Analog Output Module

TRP-C08S. USB to 1 RS232 and 1 RS422/485 Isolated Converter. User s Manual

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

User s Manual Printed Sep Rev 1.2

MINI MCR-SL-UI-2I(-SP)(-NC)

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

PCI Express 16-Port Serial I/O Cards

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

General information Engineering with Programming package. Display with display

CPCI-ASIO4 CAN - RS-232, RS-422, RS-485

HEC. General Operating, Maintenance and Installation Manual

Product Manual. USB 2.0 to Serial High- Speed RS-232 Industrial Adapter. Coolgear, Inc. Version 1.1 September 2017 Model Number: USB-COM-M

DX561 Digital Input/Output Module

General information. Display. Supply voltage. Input current

IC232 PC- CARD USER S GUIDE

General information. Display. Supply voltage. Input current

M-Bus-Logger Data Logger

USB Connectivity. USB Connectivity

Transcription:

SSW7 Adapter for MPI-Bus 700-751-1VK21 User Manual Version:2 / 2009-03-20 HW: 1 / FW: 3.0 and higher Order number of manual: 700-751-1VK21/en Systeme Helmholz GmbH Hannberger Weg 2 D-91091 Großenseebach Phone: +49 9135 7380-0 Fax: +49 9135 7380-110 E-Mail: info@helmholz.de Internet: www.helmholz.de

All rights are reserved, including those of translation, reprinting, and reproduction of this manual, or parts thereof. No part of this manual may be reproduced, processed, copied, or transmitted in any way whatsoever (photocopy, microfilm, or other method) without the express written permission of Systeme Helmholz GmbH, not even for use as training material, or using electronic systems. All rights reserved in the case of a patent grant or registration of a utility model or design. Copyright 2009 by Systeme Helmholz GmbH Hannberger Weg 2, 91091 Grossenseebach, Germany Note: We have checked the content of this manual for conformity with the hardware and software described. Nevertheless, because deviations cannot be ruled out, we cannot accept any liability for complete conformity. The information in this manual is regularly updated. When using purchased products, please heed the latest version of the manual, which can be viewed in the Internet at www.helmholz.de, from where it can also be downloaded. Our customers are important to us. We are always glad to receive suggestions for improvement and ideas. Step and SIMATIC are registered trademarks of SIEMENS

Design The SSW7 allows you to implement a serial PC interface (RS232 level, 9.6Kbaud... 115 Kbaud) on the MPI bus (RS485 level, 19.2 or 187.5Kbaud) for programming software, operator terminals, or visualization. The SSW7 has a 1.2m long connecting cable, which can be directly plugged into the CPU socket of the programmable controller or at any other point in the MPI network. A nine-way D-sub connector with a pin assignment suitable for a standard PC null modem cable is contained in the housing of the SSW7 (cable is part of the scope of supply of the SSW7). The SSW7 receives its power supply from the CPU via the MPI cable. If 24V are not available at the point of connection or if several SSW7s are connected to a CPU at the same time, the 24V power supply can be fed from an external source. The connection to the MPI bus can be extended with an additional cable. For that purpose, Systeme Helmholz GmbH offers the following products: MPI bus extension cable, 5m MPI bus extension cable, 10m MPI bus extension cable, special length 700-751-6VK11 700-751-6VK21 700-751-6SO11 When extending the MPI bus, please follow the relevant configuring guidelines as defined in the documentation of your PLC. The SSW7 and the extension cable do not contain any terminating resistors. i For the SSW7, a wall bracket, a DIN rail bracket (700-751- 1HSH01), and an S7-300 sectional rail bracket (700-751-PSH00) are available. FM35x modules cannot currently be parameterized with the SSW7. SSW7 Page: 4

Parameterization The SSW7 settings are defined in the software used for communication with the programmable controller. This might be programming software, or the parameterization software of an operator panel, or the parameterization of a display. There is no special parameterization tool for the SSW7 because the parameterization of the adapter is automatically transmitted to the adapter every time the software is used. Parameterization is therefore not stored in the adapter. If you use programming software, use the driver "PC adapter (MPI)": Of course, only 19.2Kbaud and 38.4Kbaud are available as PC baud rates. The SSW7 is automatically set to the baud rate used. If the "PC adapter" driver is not shown in the menu above, you can have it installed subsequently with the function "Interfaces: Add/Remove". SSW7 Page: 5

Speed up driver for Win 2000 and XP For using the SSW7 with 115Kbaud you have to install the Speed-up driver V3.0. The actual version is available at www.helmholz.de. Is there an older high speed driver running you MUST close AND uninstall this before continuing! The Speed-up tool creates a new serial COM port. The driver brings the data transfer from the virtual to the physical COM port and vice versa. After the installation start the driver via the symbol in the start menu. There is only an additional symbol in the systray. Right click to symbol opens the context menu for the properties. 1.) Activate the new virtual COM port in the dialog box. 2.) Set the COM port where the SSW7 is plugged in. 3.) Set the baud rate you want to use. Select the OK button to activate the driver. This new COM port has to be used from your applications now. For more details please see the documentation for SSW7 driver software. Right click to symbol opens the menu - select end for deactivating the Speed-up tool. SSW7 Page: 6

SSW7 parameterization software With the "SSW7 Tool V3", it is possible to preparameterize or update an SSW7 with any computer, even if there is no Step 7 software installed on that computer. The "SSW7 Tool V3" can be obtained from our download area on our Internet site www.helmholz.de. LED displays The three LEDs on the top of the device provide you with information about the operating status of the SSW7. You can use them to locate sources of error quickly. The LEDs have three different states: Off, on, blinking. If the LED is off, none of the labeled states applies. Upper LED off: Upper LED on: running The adapter has no power or is faulty The adapter is being powered with 24V and the processor is Upper LED blinking: Has no meaning on the SSW7 Center LED on: The SSW7 is registered in the MPI network Center LED blinking: The SSW7 is being parameterized Lower LED on: The SSW7 has established a connection Lower LED blinking: The SSW7 is transmitting data SSW7 Page: 7

Technical data Order number SSW7 700-751-1VK21 Dimensions Weight connector) MPI interface Type: Transmission rate: Cable: Connection: Communication interface Type: Transmission rate: Connection: 105 x 53 x 29 mm (LxWxH) approx. 180g (incl. MPI cable & RS485, isolated 19.2 kbps to 187.5 kbps 1.2m, no terminating resistors Connector, SUB D 9-way RS232, serial asynchronous 19.2 kbps to 115 kbps Automatic detection! Connector, SUB D 9-way Power supply Voltage: +24V DC ±25%, from the programmable control or external power supply (polarized) Power supply: 30mA (typ.) / 45mA (max.) Degree of protection IP 30 Electromagnetic compatibility (EMC) Interference emission Class B to EN55022 Interference immunity on signal lines ±2kV acc. to EN61000-4-4 Noise immunity ESD ±6kV contact discharge EN61000-4-2 ±8kV air discharge EN61000-4-2 RF radiation fields 10V/m acc. to EN61000-4-3 Conducted RF interference 10V acc. to EN61000-4-6 Climatic conditions Temperature during operation Temp. storage/transport Relative humidity operation Relative humidity storage -20 C to +60 C -20 C to +60 C 5% to 85% at 30 C (no condensation) 5% to 93% at 40 C (no condensation) Special features Quality assurance According to ISO 9001:2000 Maintenance Maintenance-free (no battery) SSW7 Page: 8

Pin assignment Pin SUBD connector PC SUBD connector MPI 1 DCD n.c. 2 Rx M24V 3 Tx DATA.B 4 DTR RTS AS 5 GND 0V (M5V) 6 DSR n.c. 7 RTS +24V 8 CTS DATA.A 9 RI RTS PG Connecting cable MPI extension cable (700-751-6VKx1): PC to SSW7 (included): signal direction SSW7 Page: 9