Technical Description

Similar documents
Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2

WiBox 2100 Quick Start Guide

Industrial Serial Device Server

Technical Description. Special Software FG (for System 4465) version

WiSpan Quick Start Guide

ACE PLUS CORP. APCON100 series Operation Manual RS-232 to Ethernet Converter

LM300 Bluetooth Ethernet Access Point/Server 3 Simultaneous Bluetooth SPP Connections

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

e-net TCP/IP Converters

User s Manual. INAT echolink Serial / Industrial Ethernet- Converter. Manual-Version e

User Manual A08. User Manual

The possibility of combining interface modules allows various bus and network systems to be integrated into the B&R SYSTEM 2005.

2004 Copyright BlackBox is a trademark of BlackBox. All rights reserved Rev. A 01/04. LES2700A-10 Quick Start Guide

TCP/IP Converter. EX-9132 Operation Manual for 8051 Series

SERIAL TO ETHERNET CONVERTER E-P User Manual

LM300 Bluetooth Ethernet Access Point/ Server 3 simultaneous Bluetooth SPP connections

Site Ethernet Interface Installation Manual

PortStore. Ethernet - RS232 Buffer 512 or 2048 kb. RS-232 Serial line buffer controlled over Ethernet interface.

Conettix ITS-D6682-INTL

Ethernet Serial Server

SSE232-LE Serial Server- User s Manual

Canlan INSTALLATION MANUAL

Fics-RT1. User s Manual

USR-TCP Hard version: V2.0 File version: V

Chapter 5: Communications 5 1 SR55 Communications Overview 5 2

ECOV-110 User s Manual

Operation Manual of EX-9132C-2. Serial to TCP/IP Converter

Operation Manual of EX9132CST-Series

Installation and User Guide

RN-WIFLY-EVAL-UM. WiFly Evaluation Kit Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM-1.0 Version /8/2011 USER MANUAL

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

UDS1100 User Guide Part Number Revision D August 2008

DGH A3000 Configuration Guide For use with DGH Modules

Serial to Ethernet Converter

NordField Electronics

MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual

INDEX. Document Name : User Manual for SC10EJ Serial to Ethernet Converter

Appendix A Cable Pinouts

GE s Automation & Controls

Conettix ITS-D6682-UL

Volume 1 Hardware Manual

Installing the Cisco Unified Videoconferencing 3545 MCU

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed September Rev 1.6

11 Serial Communications

- Data exchange using configuration-based and logic-based Ethernet Global Data

EZL-400S User s Manual

Cable Pinouts. SRP I/O Module

FERGUSON BEAUREGARD. RTU-5000 Configurator User Manual

Quick Start Guide. 2-Port 10/100 Device Server RS-232/422/485 DB9 M. Access two serial RS-232 or RS-422/485 devices over a 10- or 100-Mbps network.

Total Control System Application Guide

CF2SCSI Disk Bridge User Guide

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed Apr.2014 Rev 1.3

Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index

LevelOne. User Manual. WAP Mbps PoE Wireless AP V3.0.0

NE-4100 Series Serial Command Mode User s Guide

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

LM300 Manager User Manual. Document Version: 1.1 LM300 Firmware Version: Bluetooth Firmware Version:

EMERALD-MM-8P. 8-Channel Software Programmable Protocol. Serial Port PC/104 TM Module. User Manual V1.20

CONFIGURATION GUIDE A-B REMOTE I/O LINK ADAPTOR FOR DL-KFR PC CARDS

xpico 110 Wired Device Server Module User Guide

Upgrading the Software

Soekris Engineering. net4801 series boards and systems. User s Manual

WM-120. Serial to Ethernet Module. Serial to Ethernet Module. User Manual. Version 1.0. Infosystem Technology Corporation, Ltd.

Multiplexer FMUX/SAT. 4 x E1 ports V.35/RS-530/RS-449 link interface in codirectional mode. Installation and Operations Manual

GPORT104 User s Manual

USR-TCP Hard version: V1.1 File version: V

PCard2SCSI Flash-Tape User Guide

ZIC2410 User Guide Device-Programmer Software Manual

IntelliServer RAS 2000 TM PowerRack Windows NT Supplement

WIFLY SERIAL ADAPTER RN-370 & RN-374

1. Introduction. Be sure to read the release notes in section 10 before operating the Unit.

Time synchronization for APR64 / APR64M

SERVICE INSTRUCTION. Updating the firmware and software on the RCS-2

EXPRESS. Users Guide. Version 3.5

ecov-110 User s Manual (V0.9f_Eng)

RADview. Element Management System Optimux-4E1, Optimux-4T1 Optimux-4E1L, Optimux-4T1L RAD Data Communications Publication 07/05

ETH to 232 (A) User Manual

ASL Holdings Ltd. User Guide for the: - DELTA PLUS LAN modem. Provisional Ver1.8

ETHM-2. Ethernet Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

UDS2100 Device Server User Guide

UniMod Ethernet. LAN-Modem. Bär Industrie-Elektronik GmbH Siemensstr. 3 D Fürth Germany

GPS IRIG-B/NTP Time Server GPS-2-E-NTP

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.

General Specifications

ProjectorNetTM Adapter Quick Start Guide

ProSoft Technology, Inc. RTU-5/03 Processor for Allen-Bradley SLC Modular Racks Inside this Manual

GW1000 User s Guide. Revision 1.04 Mar 30, 2008

LevelOne FBR User s Manual. 1W, 4L 10/100 Mbps ADSL Router. Ver

Initial Configuration for the Switch

XPort Direct+ Integration Guide/Data Sheet

GPS NTP Time Server for Intranet Networks DIN RAIL Version

Operation Manual EX-9133C-2-MTCP

HandsOn Technology -- HT-MC-02 MODEL: HT-MC-02

The following are basic setup instructions for the LAN-520 AESP. Some settings may not apply to every application.

XPress DR Industrial Device Server User Guide

RS-232/422/485 Over IP Adapter

Table of Contents. NBC User's Manual

Transcription:

Technical Description Network Interface Card for NTP- and udp/time protocol version 01.00 22.02.99

Company Info hopf_elektronik Nottebohmstr. 41 Post box 1847 58511 Lüdenscheid 58468 Lüdenscheid tel.: ++49 (0)2351 / 938686 fax: ++49 (0)2351 / 459590 internet: http://www.hopf-time.com e-mail: info@hopf-time.com version 01.00 page 2

Table of Contents CONTENTS Page 1 Network Interface Card 4 2 Hardware Installation Requirements 4 2.1 Controller 4 2.2 Controller Setup 4 2.2.1 Steps to configure the controller 4 2.2.2 The following shows a typical setup session 5 2.3 Network Parameters 6 2.4 Network Clock Parameters 6 3 Time distribution formats 7 3.1 NTP 7 3.2 udp/time 7 3.3 Proprietary protocol 7 3.4 Network connectors 8 4 Serial interface 9 4.1 LED status and error codes 9 5 Maintenance and testing 10 5.1 Monitor commands 10 5.2 Firmware download serial 10 5.3 Firmware download from host 11 6 Technical data 12 6.1 CPU, Memory, Controllers: 12 6.2 Serial interface 12 6.3 Network Interface: 12 6.4 Power Supply: 12 6.5 Status Indication 12 6.6 Token Ring Version 12 version 01.00 page 3

1 Network Interface Card The hopf_network Radio Clock is a board which receives standard world time information from the hopf_gps or DCF77 system 7000/1 bus, and makes this information available to computers, controllers and other equipment needing correct time information. The time information is distributed over the network interface and the Network Radio Clock supports the most popular time distribution protocols, NTP, time/udp plus an easy-to-integrate proprietary protocol, which supports broadcasting. 2 Hardware Installation Requirements 2.1 Controller The controller can be installed anywhere in the network and has to be connected through the appropriate interface and cables. 2.2 Controller Setup Before connecting the controller the first time to the LAN, it has to be configured, preferably through its serial port and a terminal or terminal emulation software on a PC. Connecting the controller to the network with wrong settings might produce network faults, especially if a wrong Token Ring ring rate or duplicate IP address is set. 2.2.1 Steps to configure the controller 1. An ASCII terminal or PC with a terminal emulation is connected to the first serial port (CN1) of the Controller. The terminal must be configured to 9600 Baud, no parity, 8 bit, 1 or 2 stop bits. 2. To enter configuration mode, the controller must be reset (by pushing the reset switch, if installed, or by cycling the power). Immediately after power-up, the controller performs a self test and lights all three status LED s. 3. Within about one second, the red LED starts blinking and an asterisk (*) is sent out over the serial line. Three small x characters (HEX value 120h) must be sent at that time. The controller responds with Identification data (serial number, software version etc.) and asks for a <CR> (HEX 0Dh) to enter setup mode. version 01.00 page 4

2.2.2 The following shows a typical setup session *xxx *** FunkUhr atomic reference clock *** Serial Number 102-040 Software Version 02.97 (980609) Press Enter to go into Setup Mode After <CR> is entered, the actual settings are displayed and parameters can be changed. *** basic parameters Hardware: Ethernet TPI IP addr 150.100.100.021, no gateway set *** Funkuhr parameters Antenna type: Hopf 6021 UDP datagram disabled Change Setup (0 Basics, 1 FunkUhr, 8 exit, 9 save and exit)? 0 0 <- start basic setup Ethernet Interface AUI (N) N IP Address : (150).(100).(100).(021) Set Gateway IP Adress (N) N Netmask: Number of Bits for Host Part (0=default) (00) Change telnet config password (N) N *** basic parameters Hardware: Ethernet TPI IP addr 150.100.100.021, no gateway set *** Funkuhr parameters Antenna type: Hopf 6021 UDP datagram disabled Change Setup (0 Basics, 1 FunkUhr, 8 exit, 9 save and exit)? 1 Change Setup (0 Basics, 1 FunkUhr, 8 exit, 9 save and exit)? 1 1 <- start funkuhr setup Antenna Type (0=DCF77,1=Trimble,2=TRAK,3=Hopf 6021) Enter UDP Port (hex 0000), 0 to disable Send Block every n minutes (001) Send UDP broadcast (N) N Enter up to eight target addresses for UDP block, 0.0.0.0 to end #1 : (000).(000).(000).(000) *** basic parameters Hardware: Ethernet TPI IP addr 150.100.100.021, no gateway set version 01.00 page 5

*** Funkuhr parameters Antenna type: Hopf 6021 UDP datagram disabled Change Setup (0 Basics, 1 FunkUhr, 8 exit, 9 save and exit)? 0 save and exit The controller can be configured over a Telnet connection to port 9999 (assuming the network parameters are set correctly and it is connected to the network). 2.3 Network Parameters Within the basic parameters, the controllers IP address and network interface selection are most important. Make sure that a valid IP address for the network is entered and the right network interface is selected (model dependent) before connecting to the network. The default gateway IP address has to be set to the default router or gateway if targets outside of the logical network have to be adjusted or the controller must be reached by computers from outside the logical network. The netmask setting is important if the standard IP addressing scheme (Class A/B/C) is not used (active sub-netting). The netmask is entered for historical purposes as the # of host bits. Zero means standard Class A/B/C. Some examples: Netmask # host bits 255.255.255.192 6 255.255.255.128 7 255.255.255.000 8 255.255.254.000 9 The Telnet password prevents unauthorized access to the setup menu over the network (through the serial interface, the password is not required). It s maximum length is 4 characters. Token Ring Version: The Ring Speed has to be set by Jumper (installed: 16Mbit, open: 4Mbit) to avoid a configuration error by accident. An administered address can be entered in the dialog. 2.4 Network Clock Parameters The network parameters control the operation of the Server. The UDP port selects the port number for the proprietary protocol. To be compatible with PC software and KABA Benzing Terminals, it should be set to 77FF (hexadecimal). The remaining parameters cover how often the data block should be sent (starting at every full hour), if it should be sent as broadcast, and, additionally, up to eight target addresses can be defined to which the data block should be sent. NTP and udp/time port numbers are fixed to the values defined in RFC-37 and RFC-123 respectively. If the authentication option is enabled, up to seven md5 or DES keys can be entered (key numbers 1..7). All key input must be done in hexadecimal, and md5 key length is limited to eight char acters. When leaving the setup mode (by selecting function 9), the parameters are stored in nonvolatile memory and the controller goes through a reset. version 01.00 page 6

3 Time distribution formats After the Network Radio Clock receives valid time information, it distributes the standard time via different services to the systems connected to the LAN. 3.1 NTP The controller operates in server mode. Symmetric operation modes are not supported. It understands NTP Version 1, 2, and Version 3 frames, and optionally supports authentication via DES and MD5 cryptographic checksums. If authentication is not used, the controller can typically be used for hundreds of clients without overloading it. Authentication requires typically 40 ms for checking and generating the cryptograms, which is covered and averaged out by the protocol. The Network Radio Clock supports full SNTP and all NTP functions required for reliable server operation. Functions not required for server operation are not implemented. 3.2 udp/time This rather old protocol has a resolution of one second, and is used by older UNIX systems and a variety of PC and technical equipment solutions. 3.3 Proprietary protocol This has been developed to ease the setting of KABA Benzing Terminals and controllers which are connected to the networks with BETA and BETOR network adapters. Also suitable for Windows 3.1, 3.11 PC s and other systems which do not support NTP. A simple C program sample source works on UNIX and VMS systems and can easily be ported to others. In central Europe, it can be used to facilitate automatic daylight savings switching, as the Network Radio Clock knows the CET rule (and DCF77 provides an indicator). This Protocol simply sends out a UDP block in a programmable interval as broadcast or direct to targets. The port number can be set, but it is necessary to set it to 77FF(hex) for operation with KABA Benzing equipment and the provided software. UDP Block contents: UDP Data offset Contents 00..14 ASCII string, containing CET/CST 00..01 Year (00..99) 02..03 Month (01..12) 04..05 Day (01..31) 06..07 Hour (00..23) 08..09 Min. (00..59) 10..11 Sec. always 00 12 Day of week (1-Mo, 2-Tue..) 13 DST active (0-no,1-yes) 14 String termination, \0 16..19 CET/CST time in UNIX format 32bit value, network byte order seconds since 1/1/1970 20..23 GMT time in UNIX format 32bit value, network byte order seconds since 1/1/1970 version 01.00 page 7

This data can be used to synchronize to about one second accuracy, as the block is sent out at the beginning of the first second of every minute. This interval can be changed. The controller can be configured with various methods, remote or locally. To configure locally, access to the first (or only) serial port and an ASCII terminal is necessary. To configure over the network, a Telnet connection to port 9999 must be established. The controller configuration is stored in nonvolatile memory. The configuration can be changed at any time. 3.4 Network connectors Depending on the model, the Network Radio Clock features 10-Base 2, 10-Base T and/or AUI connectors. Selection of the active connection is done by software. The transceiver interface can supply 12 V, up to 300 ma. If more power is needed (i.e. for a fiberoptic transceiver), an external transceiver power supply must be used. version 01.00 page 8

4 Serial interface The setup menu is available at the (first or only) serial port at the controller. Pin-out of the RJ-45 connector for the 19 rack version: Pin RS 232 RS485 1 Shield Shield 2 CTS (input) TXD 3 TXD (output) RXD + 4 DTR (output) RXD 5 Signal GND TXD + 6 RXD (input) Signal GND 7 CD (input) 8 RTS (output) Signal GND 4.1 LED status and error codes After the initial self test phase, where all status LEDs should be lit, the LEDs indicate the status of the Network Radio Clock. Green LED on: synchronized to the time signal, correct reception of time data. Green LED flashing 50% duty cycle: Some information received, but not yet synchronized reliable. Red LED stable on or flashing 50%, green LED flashing: 1x: EPROM-checksum error 2x: RAM-error 3x Network controller error 4x: E²PROM checksum error or bad 5x: I P address already used on network version 01.00 page 9

5 Maintenance and testing To enter monitor mode, the same principle as setting the parameters is used (see Controller Setup). Instead of entering three x, x x 1 is keyed in. The controller will respond with a special prompt. Network functions are needed for some diagnostics commands and it may take up to 20 seconds until the network part of the controller is initialized and the prompt is displayed. This is especially true if a token ring is empty or a ring simulator is used. For a simple ring simulator, see the appendix. To start the monitor mode without network functions, enter xx2 (new function from Version 2.05 up). Please note : A Token Ring controller needs a working network connection to enter monitor mode 5.1 Monitor commands The following commands are available in the monitor mode. Many commands have an IP address as an optional parameter (x.x.x.x). If it is given, the command is applied to a remote controller with that IP address. If no IP address is given, the command is executed locally. All commands must be given in capital letters, only blanks are accepted as white space between parameters. DL SF x.x.x.x VS (x.x.x.x) GC (x.x.x.x) SC (x.x.x.x) PI x.x.x.x QU Firmware download to the Controller Send Firmware to Controller with IP x.x.x.x Query software header record (16 Byte). Get configuration as HEX records (120 Bytes) Set configuration from HEX records (120 Bytes) Check with ICMP packages (PING) if IP x.x.x.x is alive reachable. Quit - exit diagnostics mode command result codes: 0 OK, no error 1 no answer from remote device 2 cannot reach remote device or does not answer 8 wrong parameter(s) 9 invalid Command 5.2 Firmware download serial Downloading is done in Monitor mode. Once in Monitor mode, the DL command is given. The node now waits for the firmware image in "HEX" format, which must be sent complete through the serial interface. When the end record is received, the controller checks the integrity of the firmware image and then starts programming the new firmware in the Flash prom. After complete reprogramming, the controller resets. WARNING! A loss of power while reprogramming will result in a corrupt program image and a nonfunctional controller. version 01.00 page 10

5.3 Firmware download from host To download a new firmware from a computer to a CoBox, a working TFTP implementation is needed. For Win95 systems, a download program is available from hopf_on request. The parameters to send the firmware are: Target filename: 3Q Transfer mode: binary The file to be downloaded must be the "ROM" image, not the "HEX" version. File size should be 32768 or 65536 bytes. WARNING! A loss of power while reprogramming will result in a cor -rupt program image and a nonfunctional controller. version 01.00 page 11

6 Technical data 6.1 CPU, Memory, Controllers: V.40 CPU, 10 MHz clock Z85C30 SCC Serial Controller National Semiconductor DP839xx Ethernet Controller or IBM Tokenring OEM module (starting 1997: TMS340 chipset) 128kByte RAM, 128k-512kByte Flash PROM 256 Byte E²PROM for parameter storage 6.2 Serial interface External 19 Rack OEM module Connector SubD25 RJ-45 pin strap Speed..38400..38400..19200 RS-232/485 sw software jumper TTL level only 6.3 Network Interface: 10-Base T interface 6.4 Power Supply: 5 V, 600 ma max, +12 V, -12 V 6.5 Status Indication Three colored LED s. 6.6 Token Ring Version Network Interface The Token Ring controller has a standard D-Shell 9 pin female connector to be connected to standard token ring drop cables. The ring interface speed is configured by a jumper to prevent accidental misconfiguration. After opening the case, a jumper must be removed for 4 Mbit operation (delivery standard is jumper installed, 16 Mbit). version 01.00 page 12