TS 90 door control Automatic control panel for GfA ELEKTROMATEN drives with DES digital limit switch or NES mechanical limit switch Approvals and certificates TS 90 TS 90 Type test according to: DIN EN DIN EN 9 DIN EN 0--0 DIN EN ISO 9- TÜV NORD CERT GmbH TS 90 Automatic control panel for DES / NES limit switches Technical data For all GfA ELEKTROMATEN drives with DES or NES Supply voltage: N~0V, PE / ~0V, PE / N~00V, PE / ~00V, PE Operating frequency: 0 / 0 Hz Control voltage: V DC Mains supply ratings for external devices: V DC (0.A) / 0V AC (.A) Permissible temperature range: -0...+0 C Housing Dimensions W x H x D [mm]: x x 90 ( ) IP rated when hard wired or IP if CEE plug used Protection against contact provided by covers for live parts Top and botton entry for ELEKTROMATEN connection cables Design Integrated OPEN-STOP-CLOSE control device Safety reversing contactor (with independent shutdown options) Settings via selector switch with digital display Pluggable connection technology Connection cable running to ELEKTROMATEN available in various lengths Independent, programmable relay contact, e.g. usable for red or green traffic-lights or dock-leveller enabling UBS module for the simple connection of control devices, photo cells, etc. (for details on UBS accessories, see.09) Slack-rope and pass-door plug-in connection points Accessories Emergency-stop switch Key switch For description and details on further accessories, see.09 Functions Automatic detection of DES or NES limit switches Change of rotating direction from control panel Adjustment of limit positions (only DES) and all functions from the operator level Selectable operating mode: CLOSE / OPEN in hold-to-run mode CLOSE in hold-to-run mode / OPEN in self-hold mode Hold-to-run operation with active safety edge system CLOSE / OPEN in self-hold mode Automatic safety edge detection and evaluation: Optical safety edge system (e.g. Vitector system) NO-contact principle, K NC-contact principle, K, with testing Automatic closing with adjustable time setting (-0 seconds) (function can also be activated/ deactivated): Once the top limit position or intermediate open position has been reached, the door closes automatically after the set duration Interruption to timer possible via photo cell activation Adjustable intermediate open position with individual programming options Setting of the permissible number of safety-edge actuations for automatic closure (0-0) Adjustable reversing duration for safety-edge actuation Version with mains switch UBS universal command sensor system (see.09) Subject to alterations. (_Li).0
Further functions Automatic ground adjustment (only DES) to compensate for rope stretch or subsequent change in ground height (not for pressure-wave switches) Overrun correction (only DES) to compensate for changes to overrun, e.g. due to influence of temperature Status and information display (including display of most-recent faults); extensive evaluation via optionally-available service kit (adaptor + software, see.09) Cycle counter (non-resettable) Maintenance-cycle counter: Setting range:,000-99,000 cycles Display or switch to hold-to-run operation once the maintenance-cycle limit is reached Detects door / drive blockage (only DES); in this event the control deactivates the drive unit Dynamic run time monitoring (only NES): With every door movement, the time taken to run between the end positions is measured and compared with the most-recently set reference duration If the run duration is increased (pre-settable deviation), the control panel is deactivated Adjustable force monitoring in OPEN direction (only DES): For counterbalanced doors, sudden changes to the counter-balancing are detected Self-learning feature and consequently no activation of force monitoring function due to, e.g., a change in spring tension Automatic detection of ELEKTROMATEN unit with direct inverter (DI) or frequency inverter (FI): Setting of output speed Soft start and soft stop through automatic adjustment of acceleration and braking ramps Possible to modify acceleration and braking ramps Connection options TS 90 V / 0. A External N~0 V, PE ~0 V, PE N~00 V, PE ~00 V, PE N E S D E S With integrated U Universal B Command sensor S System 0 V /. A External.0 Subject to alterations. (_Li)
Complete door control with connection kit connection kit, when hardwired With mains supply terminal and slide gland 09000.0000 CEE N~00V (-pin) of length 0.m 09000.0000 CEE N~0V (-pin) of length 0.m 09000.0000 CEE N~0V asym. (-pin) For SI. WS / SI. WS / ST. WS; with pluggable mains supply cable of length 0. m 09000.000 CEE ~0V (-pin) of length 0.m 09000.000 mains switch / isolator N~00V With mains switch / isolator in large cover 09000.000 mains switch / isolator N~0V With mains switch / isolator in large cover 09000.000 TS 90-XL with mains switch / isolator N~00V Suitable for additional equipment W x H x D [mm]: 00 x 00 x () Protection class: IP - Slide gland for pluggable connection cable running to ELEKTROMATEN drives - -pin mains switch - DIN mounting rail - x M0 cable glands 09000.00 Separate connection kits, when hardwired Mains supply terminal and slide gland 000.0000 CEE N~00V (-pin.) of length 0.m 000.0000 CEE N~00V, IP (-pin) of length 0.m 000.0000 CEE N~0V (-pin) of length 0.m; 000.0000 CEE N~0V asym. (-pin) For SI. WS / SI. WS / ST. WS; with pluggable mains supply cable of length 0. m 000.000 CEE ~0V (-pin) of length 0.m 000.000 with connection kit N~00V Assembly kit for mains switch / isolator (complete) 000.000 with connection kit N~0V Assembly kit for mains switch / isolator (complete) 000.000 Subject to alterations. (_Li).0
Accessories Designation Description DES connection cable NES connection cable Part no. Connection to ELEKTROMATEN drives with digital limit switch, pluggable on both sides; length of cable:,0m,0m,0m 9,0m,0m,0m,0m Further lengths available, upon request Connection to ELEKTROMATEN drives with mechanical limit switch, pluggable on both sides; length of cable:,0m,0m,0m 9,0m,0m,0m,0m Further lengths available, upon request Spiral cable with junction box (IP) Straight cable ends (.0 m/0. m); length of coiled cable: 0.9 m; max. stretched length:.0 m - For OSE (optical safety edge system, e.g. Vitector system) - Can be combined with OSE system or Universal OSE set, for system System = one junction box; transmitter + receiver, pluggable design with receiver (0.m long cable) and transmitter with Universal OSE set, for system 0000.0000 0000.0000 0000.0000 0000.00900 0000.000 0000.000 0000.000 0000.0000 0000.0000 0000.0000 0000.00900 0000.000 0000.000 0000.000 0000.0000.m cable 0.m cable 000.000 000.000 System = junction box + junction end box; transmitter + receiver, pluggable designs with 0.m long cables for each 000.0000 Are also required for system : + Junction end box (IP) for system With plug-in connection points for transmitter / receiver, as well as for pass-door and slack-rope switches Connection cable for system Pluggable on both sides, -wire, cable length: Splash guard 000.m.m.m 0.m 0000.000 0000.000 0000.000 0000.000 Mechanical protection against water; For spiral cable with junction box and junction end box 00.0000 Further accessories are described in Section 9, e.g. radio from page 9.0 Example with system Example with system /.0 Subject to alterations. (_Li) /
Accessories with connection kit See Separate connection kits on page.0 Key switch Assembly kit for installation in small cover 000 Emergency-stop switch Assembly kit for installation in small cover 000 Toggle switch for intermediate open position Assembly kit for installation in small cover 00009 Keypad cover For preventing unintentional pressing of keypad buttons (e.g. for use in underground car parks), increased protection against direct contact with water 00.0000 Loop detector, two-channel Snap-in system (with UBS module) 00 Service program with adaptor For installation on desktop PC or laptop; for reading out and displaying of important data from the door control (e.g. programming, stored error logs, etc.) 0000 GfA-Stick For use with smartphone or tablet PC together with the GfA+ App; for reading out and displaying of important data from the door control (e.g. programming, stored error logs, etc.) 0009 Arrangement Subject to alterations. (_Li).09
Spare parts TS 90 board Within cover incl. keyboard 000.0000 Bottom section of housing TS-B For installation of the TS-board 00 Cover kit TS-B + Consists of: small cover, large cover 0009.0000 Cover kit TS-B for mains switch Spacer foot TS-B + Consists of: small cover, large cover, prepared for mains switch pcs. 0009.0000 000 Membran push button for TS 90-XL With viewing window 0000.00 Subject to alterations. (_Li)