Huawei Smart Cooling Solution

Similar documents
Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

HUAWEI TECHNOLOGIES CO., LTD. Huawei IDS2000-S Small Modular Data Center Solution

ZTE ZXCR Series DX In-Row Air Conditioning Product Description

IT Air Conditioning Units

Liebert DM. High Performance, Sensible Cooling for Small Computer Rooms and Network Closets

UPS5000-E (25-75 kva) Series

Rack cooling solutions for high density racks management, from 10 to 75 kw

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

PEX+ High Efficiency, Low Operating Cost Precision Solution for Data Centers

IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw

PEX (R410A) High Efficiency, Green Solution Precision Cooling for Data Centers

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

Precision Cooling Mission Critical Air Handling Units

Ecoflair Air Economizers

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Huawei FusionHome Smart Energy Solution

HUAWEI Smart Outdoor Site Solution

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

Smarter Energy for a Better Life. Huawei FusionHome Smart Energy Solution. For Homeowners

Ecotel Free Cool 5-15kW

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

SmoothAir Modular Precision Cooling

PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 05 Jl. Malibu Raya, Cengkareng Jakarta Barat Indonesia. Phone

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Liebert. AFC from 500 to 1700 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

Smarter Energy for a Better Life. Huawei FusionHome Smart Energy Solution. For End Users

About Huawei. A Global Leader of ICT Solutions

Total Modular Data Centre Solutions

FREECOOLING, EVAPORATIVE AND ADIABATIC COOLING TECHNOLOGIES IN DATA CENTER. Applications in Diverse Climates within Europe, Middle East and Africa

Huawei Energy Powering the Future. Huawei UPS Solutions. Huawei Energy Powering the Future HUAWEI TECHNOLOGIES CO., LTD.

Efficiency of Data Center cooling

Rack & Enclosure Systems

Trademark Notice. General Disclaimer.

HUAWEI Tecal X8000 High-Density Rack Server

Close-coupled cooling

HUAWEI TECHNOLOGIES CO., LTD. HUAWEI FusionServer X6000 High-Density Server

i-accurate_gb_ High precision air-conditioners for data centres cooling, with new inverter technology and R-410A refrigerant, from 6 to 150 kw

CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW. The indirect evaporative free-cooling Air Handling Unit

STULZ Micro DC. with Chip-to-Atmosphere TM Liquid to Chip Cooling

Air Handling Units. With Intelligence

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.

Liquid Cooling Package LCP Cooling Systems

Liebert DM. High Performance, Sensible Cooling for Small Computer Rooms and Network Closets

Huawei KunLun Mission Critical Server. KunLun 9008/9016/9032 Technical Specifications

Liebert. icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

Huawei KunLun Mission Critical Server. KunLun 9008/9016/9032 Technical Specifications

Rectifier Module R4815N1. Introduction. Feature Features High efficiency: >94% Output feature. Efficiency curve

INNOVATE DESIGN APPLY.

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Liebert. AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability CERTIFIED HVAC-HYGIENE.

INNOVATE DESIGN APPLY.

DATA CENTER PRECISION COOLING: The Need For A Higher Level Of Service Expertise

Data Center Optimized Controls

CHAPTER 3 WATERCOOLED & CONDENSERLESS LIQUID CHILLERS AND HEAT PUMPS FOR COMMERCIAL & INDUSTRIAL APPLICATION. REMOTE CONDENSERS

Is Data Center Free Cooling Feasible in the Middle East? By Noriel Ong, ASEAN Eng., PMP, ATD, PQP

Airedale International Air Conditioning Limited. Leeds Road, Rawdon Leeds, LS19 6JY, England

Reliability and extended operation

Welcome Association of Energy Engineers to the Microsoft Technology Center

Liquid Cooling Package LCP Cooling Systems

InRow Chilled Water. Up to 70kW. Close-coupled, chilled water cooling for medium to large data centers. Row-Based Cooling.

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

Liebert PDX. The Cooling Solution for Small and Medium Data Centers. Digital Scroll. Part Load. Competent Partner Efficiency

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Smart Energy Center. Simple & Easy. Higher Revenue. Battery Ready. Safe & Reliable

Liebert PDX from 15 to 120 kw

COOLING SOLUTIONS. SmartRack Close-Coupled Cooling for IT Environments

HIGH EFFICIENCY Central Chiller

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

Blue e+ chillers with the principle

User's manual. GREE AHU kit. Type: U-Match Version: 1.02

Liebert PDX from 15 to 120 kw

Liebert HPC. Freecooling Scroll Chillers for the Efficient Cooling of Data Centers

Retro-Commissioning Report

Liebert. CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers

SmartCabinet Intelligent, Integrated Containment for IT Infrastructure

AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS

Rittal Cooling Solutions A. Tropp

MSYS 4480 AC Systems Winter 2015

Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

Modular Uninterruptible Power System

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw

Thermal management. Thermal management

2018 Product overview

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

IDCE-840CT Battery Discharger & Capacity Tester

24/48V Battery Bank Ah High Cycling Long Life

Liebert. PDX from 15 to 165 kw. Direct Expansion Solution for Small and Medium Data Centers

Lightning Fast Rock Solid

HIGH DENSITY RACK COOLING CHOICES

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

Precision Cooling for Business-Critical Continuity. Liebert CRV. Efficient Cooling For IT Equipment NEW. Extended Range Available From 10 To 50 kw

LCP Hybrid Efficient performance with heat pipe technology

FACT SHEET: IBM NEW ZEALAND DATA CENTRE

ENCLOSURE HEAT DISSIPATION

Transcription:

Huawei Energy Powering the Future Huawei Smart Cooling Solution HUAWEI TECHNOLOGIES CO., LTD.

To meet increasing demands of data centers such as IT business integration, virtualization and cloud computing, Huawei introduces NetCol8000, inroom cooling product and NetCol5000, in-row cooling product to provide cooling solutions for various types of data centers, which ensures data centers work stably in constant temperature and humidity environment.

Huawei NetCol smart cooling product is safe & reliable, and has features such as high efficiency, high reliability, simple O & M, which makes it your best choice for cooling solution.

Contents NetCol5000-A Air Cooled In-row Smart Cooling Product...01 NetCol5000-C Chilled Water In-row Smart Cooling Product...03 A Air Cooled In-room Smart Cooling Product...05 C Chilled Water In-room Smart Cooling Product...07 Global Applications...09 In-row Smart Cooling Product NetCol5000-C (30kW) NetCol5000-A (21-42kW)

In-room Smart Cooling Product C (62-253kW) A (50-100kW) A: Air cooled C: Chilled water

Air Cooled In-row Cooling Product NetCol5000-A Introduction NetCol5000-A is the air cooled in-row smart cooling product developed by Huawei. It is configured with DC inverter compressor, EC fans, PTC electric heater and electrode humidifier. Cooling capacity is 21kW, 25kW,42kW. It is usually installed between the IT racks, closely coupled with heat source so as to provide in-row cooling solution for medium-high density data centers. NetCol5000-A supports piping and cabling from both top and bottom side of the unit, and can be accessed from both front and back side. It is an efficient, reliable and simple solution, helps to build next generation green data center. Application Scenarios Modularized data center and container data center Equipment room with partial overheat, high thermal density room and room with high energy saving requirement Medium and small computer rooms and data center (IDC) Container data center NetCol5000-A Value & Features Efficient DC inverter: inverter compressor and EC fan, 10%~100%* stepless capacity regulation, high efficiency at partial load Group control: maximum 32 units can be group controlled, precision management for capacity and power consumption Without heating water, save 95%+ energy compared with traditional humidifier Reliable Stable operation: works stably at extremely high/low ambient temperature (-40~+55ºC), with less cooling capacity derating than others Dehumidification at low load: reliable dehumidification at minimum 10% load, eliminate condensation risk Expansion valve shut automatically: Expansion valve will shut automatically after unexpected power cut, eliminate liquid return which may hit compressor Simple Intelligent display: 7 true color screen, clear and friendly operation interface, easy O&M No welding maintain: compressor uses Rotalock connection, no welding on maintenance Malfunction self-diagnosis*: remove irrelevant reason intelligently, guiding O&M engineer maintain quickly Typical applications DC inverter scroll compressor EC fan Notice: the feature with * is just for 042H. 1

Technical Specification NetCol5000-A Technical Specification Unit model Unit NetCol5000-A021H (300) NetCol5000-A025H (300) NetCol5000-A042H (600) System type Air cooled Air discharge direction Horizontal Total cooling capacity 1 kw 21.0 25.0 42.0 Btu/h 71,652 85,300 143,304 Sensible cooling capacity kw 21.0 25.0 42.0 Btu/h 71,652 85,300 143,304 Air flow m 3 /h 4,300 5,000 8,600 Power supply V/Ph/Hz 208/3/60 380-415/3/50(60) 380-415/3/50, 380-415/3/60 Refrigerant R410A Heating capacity kw 4 4 6 Humidifier capacity kg/h 1.5 1.5 3 Full load current 2 A 28.0 (48.0) 20.0 (30.0) 40.0 (46.0) Dimensions: W*D*H mm 300*1100*2000 300*1100*2000 600*1100*2000 Net weight kg 260 230 305 Notes: 1. Nominal cooling condition: Return air dry bulb temperature 37.8ºC/RH20%, outdoor temperature 35ºC 2. The data in brackets are applicable to the indoor unit with electric heater & humidifier 3. Data are subject to change without prior notice Out Door Condenser Technical Specification Unit model Unit NetCol500-A026 NetCol500-A032 NetCol500-A036 NetCol500-A072 Power supply V/Ph/Hz 380-415/3/50, 380-415/3/60, 440-480/3/60 Fan quantity 1 1 1 2 Liquid pipe diameter in 5/8 in 5/8 in Gas pipe diameter in 3/4 in 7/8 in Full load current A 2.5 2.5 2.5 4.5 Dimensions: H*W*D mm 920*1120*1094 1160*1370*1094 1160*1370*1094 1160*1370*1094 Net weight kg 132 110 130 185 Notes: Data are subject to change without prior notice; the pipe diameter only for reference and it may be changed for the actual configuration 2

Chilled Water In-row Cooling Product NetCol5000-C Introduction NetCol5000-C is a chilled water smart cooling product developed by Huawei. Basically, it is just a fan coil unit installed inside the data center, moreover, combined together with chiller, chilled water pump and piping etc.; it forms a complete cooling system. It is coupled with EC fan, and has the functions of cooling & dehumidification. Normally, it is installed between the IT racks, closely coupled with heat source so as to provide in-row cooling solution for medium to high density data centers. NetCol5000-C is an an efficient, reliable and simple solution, helps to build next generation green data center. Application Scenarios Medium-large exchange room and data room Computer room and data center (IDC) High-tech environment and lab Industry control room and precision processing equipment room Standard test room and calibration center Container data center NetCol5000-C Value & Features Efficient High efficiency DC power module: Fans are powered by high efficiency selfdeveloped DC power module, efficiency is up to 94%, unit s total rated power input is only 1.0kW High efficiency heat exchanger: CFD simulation and field synergy helps achieve optimum heat exchange, improves heat transfer efficiency by 10% Reliable Dual condensation pumps: Dual floats & dual condensation pumps, condensation drainage is not affected when one pump fails Dual power sources: automatically switches to the other power source in case of power failure Multi. EC fans: Mutual backup, ensures smooth air flow, performance is not affected when single fan is faulty Simple On-line fan maintenance: No need to switch off power for fan replacement Water piping: high quality imported rubber hose; threaded connection makes installation easier and free of brazing work It supports piping and cabling from both top and bottom of the unit, and can be accessed from both front and rare Leading-edge 7-inch colored touch screen features innovative one-touch interface switch and provides temperature & humidity curves display of the last 30 days, bringing an excellent usage experience IT Equipment 1 2 Precision AC Typical applications 7 inch LCD true color touch screen EC fan 3

Technical Specification NetCol5000-C Technical Specification Unit model Unit NetCol5000-C030H System type Chilled water Air discharge direction Horizontal Total cooling capacity 1 kw 30.0 Btu/h 102,360 Sensible cooling capacity kw 30.0 Btu/h 102,360 Air flow m 3 /h 5,100 Power supply V/Ph/Hz 220-240/1/50, 220-240/1/60 Refrigerant Water flow l/s 1.4 Water pressure drop kpa 55 Electric heating capacity kw 3 Humidifier capacity kg/h 3 Full load current 2 A 5.5 (23) Dimensions: W*D*H mm 300*1000/1200*2000 Net weight2 kg 185 Notes: 1. Nominal cooling condition: The current data in brackets are applicable to the unit with electric heater & humidifier 2. Return air dry bulb temperature 37.8ºC/RH20%, Inlet/Outlet water temperature 10ºC/15ºC 3. The unit with electric heater & humidifier does not support up piping for without water pump 4. Data are subject to change without prior notice NetCol520 liquid distribute unit Without NetCol520 (Liquid distribute unit) With NetCol520 (liquid distribute unit) NetCol5000-C Air cooled chiller NetCol5000-C Air cooled chiller Liquid distribute unit Valve Filter Valve Filter Items Parameter description Unit model NetCol520-12T (Upper water pipe) / NetCol520-12B (bottom water pipe) Dimensions 1800*1200*600mm (H*W*D) Unit weight 300kg Water flow 43.2 m 3 /h 4

Air Cooled In-room Cooling Product A Introduction A is the air cooled in-room smart cooling product developed by Huawei. It is composed of indoor and outdoor unit. Indoor unit is configured with scroll compressor, large surface evaporator, EC fan, electric humidifier and electric heater. Cooling capacity is 50kW (down flow) and 100kW (down flow). The down flow unit is usually deployed around the white space of the data center, can be installed against the wall providing 100% front access maintenance, and the fan can be sunk under the floor to further improve air supply efficiency. A is an efficient, reliable and simple solution, helps to build next generation green data center. Application Scenarios Medium-large exchange room and data room Computer room and data center (IDC) High-tech environment and lab Industry control room and precision processing equipment room Standard test room and calibration center UPS and battery room Biochemical culturing room Hospital and test room A Value & Features Efficient Energy saving logic: For single unit, unique energy-saving mode, partial load EER increased by 26%; For multi units, avoids competitive operation, collaborated efficiency optimization algorithm; energy saving by 30%+ Group control: realizes an optimized alternative operation to avoid conflict within a multi-unit system, dynamically distributes cooling capacity and provides major control system backup Typical applications Reliable Redundant design, mutual backup module, If one circuit is faulty, the operation of the other circuit is not affected Multiple system protections, including: compressor failure, insufficient airflow, high and low pressure protection of compressor, temperature/ humidity out of limit alarm, etc. Refrigerant leakage and anti-freeze protection: When refrigerant is leaked, unit automatically switched off, avoids freezing on evaporator Simple Module design, eliminates brazing work for on-site unit disassembly, reduces the requirement on dimensions of elevator and doors 100% front access, supports side by side installation, smallest maintenance space in the industry The control system, featuring self-diagnosis and precaution functions, can provide pre-maintenance tips. Discerptible modular design 5

Technical Specification A Technical Specification Unit model Unit A 050D A 100D System type Air cooled Air discharge direction Down flow Total cooling capacity 1 kw 50.0 100.0 Btu/h 170,600 341,200 Sensible cooling capacity kw 46.8 93.5 Btu/h 159,681.6 319,022 Air flow m 3 /h 14,000 28,000 Power supply V/Ph/Hz 380-415/3/50 380-415/3/50 Refrigerant R410A Electric heating capacity kw 6 12 Humidifier capacity kg/h 7 10 Full load current A 38.0 76.0 Dimensions: W*D*H mm 1140*890*1980 2280*890*1980 Net weight kg 415 830 Notes: 1. Nominal cooling condition: Return air dry bulb temperature 24ºC/RH50%,condensing temperature 45ºC 2. Data are subject to change without prior notice Out Door Condenser Technical Specification Unit model Unit NetCol500-A072 NetCol500-A088 Power supply V/Ph/Hz 380-415/3/50 Fan quantity - 2 Liquid pipe diameter in 5/8 in Gas pipe diameter in 7/8 in Full load current A 3.15 6.25 Dimensions: W*D*H mm 2180*1094*1100 2410*1270*1265 Net weight kg 185 200 Notes: Data are subject to change without prior notice; the pipe diameter only for reference and it may be changed for the actual configuration 6

Chilled Water In-room Cooling Product C 2.0 Introduction C is the chilled water in-room smart cooling product developed by Huawei. Normally combined together with chiller, chilled water pump and piping etc., it forms a complete cooling system. Cooling capacity range is from 62kW to 253kW. C is an efficient, reliable and simple solution, helps to build next generation green data center. Application Scenarios Carrier base, province/city level data center ISP, EDC, IDC Finance headquarter, disaster recovery data center Smart city, safe city E-government C Value & Features Efficient Pressure difference control: save 10%+ energy compared with ordinary EC fan with supply and return air control Fresh air free cooling: adjust fresh air ratio intelligently, save 30%+ energy comparison with traditional chilled water system Wet-film humidifier: save over 95%+ energy in comparison with electrode humidifier Reliable Modular design: no effect on the operation of the other modules even if there is one faulty module Dual power sources: dual auto-switch power supply with independent dual 6kV surge protection and power detection On-line maintenance: hot swappable for control module and auxiliary power module Simple Digital management: 7 color touch screen, cooling capacity, air flow and power consumption could be displayed Malfunction self-diagnosis: eliminate irrelevant failure reason intelligently and save pending and maintenance time 7h+ De-engineering: prefabricate components including air damper, dynamic balance valve, save installation man-hour max. 10h/unit 1. Air conditioner 2. IT equipment Typical applications Hot swapped module = + Discerptible modular design 7

Technical Specification NetCol8000 Unit model Unit C Technical C070D Specification -C100D C110D C130D C150D C160D Air direction _ Down flow Down flow Down flow Down flow Down flow Down flow Total cooling kw 63.2 100.2 113.0 126.4 150.3 169.5 capacity 1 Btu/h 215,638.4 341,882.4 385,556.0 431,276.8 512,823.6 578,334.0 Sensible cooling capacity kw 51.4 83.0 94.2 102.8 124.5 141.3 Btu/h 175,376.8 283,196.0 321,410.4 350,753.6 424,794.0 482,115.6 Air flow m 3 /h 13,500 23,000 28,000 27,000 34,500 42,000 Power supply V/Ph/Hz 380-415/3/50, 380-415/3/60, 440-480/3/60 Water flow l/s 3.02 4.78 5.39 6.03 7.17 8.09 Water pressure drop kpa 62.4 70.7 85.8 85.4 77.4 94.3 Heating capacity kw 6 12 12 12 12 12 Humidifier capacity kg/h 5 8 8 8 12 12 Full load current 2 A 4.7 (15.2) 9.4 (30.4) 8.9 (29.9) 8.9 (29.9) 13.8 (34.8) 13.1 (34.1) Dimensions:W*D*H mm 900*1000*2000 1800*1000*2000 1800*1000*2000 1800*1000*2000 2700*1000*2000 2700*1000*2000 Net weight kg 340 600 615 635 880 900 Unit model Unit C190D C220D C260D C070U Notes: 1. Cooling capacity condition:return air dry bulb temperature 24ºC/RH50%, Inlet/Outlet water temperature 7ºC/12ºC 2. The current data in brackets are applicable to the unit with electric heater & humidifier 3. Data are subject to change without prior notice C130U C190U Air direction _ Down flow Down flow Down flow Up flow Up flow Up flow Total cooling kw 189.6 226.0 252.8 61.9 123.8 185.7 capacity 1 Btu/h 646,915.2 771,112.0 862,553.6 211,202.8 422,405.6 633,608.4 Sensible cooling capacity kw 154.2 188.4 205.6 50.3 100.6 150.9 Btu/h 526,130.4 642,820.8 701,507.2 171,623.6 343,247.2 514,870.8 Air flow m 3 /h 40,500 56,000 54,000 13,200 26,400 39,600 Power supply V/Ph/Hz 380-415/3/50, 380-415/3/60, 440-480/3/60 Water flow l/s 9.05 10.79 12.07 2.95 5.91 8.86 Water pressure drop kpa 96.0 108.8 114.0 60.5 82.6 92.7 Heating capacity kw 12 12 12 6 12 12 Humidifier capacity kg/h 12 12 12 5 8 12 Full load current 2 A 13.1 (34.1) 17.3 (38.3) 17.3 (38.3) 4.7 (15.2) 8.9 (29.9) 13.1 (34.1) Dimensions:W*D*H mm 2700*1000*2000 3600*1000*2000 3600*1000*2000 900*1000*2000 1800*1000*2000 2700*1000*2000 Net weight kg 930 1195 1225 330 615 900 8

Global Applications Germany GELSEN-NET England FlexiScale France IPSIP Portugal Benfica Mexico PEMEX KSA MOI Forensic Dubai International Airport Venezuela Can TV Abu Dhabi ADNOC Ghana MTN Brazil Vert African Union Conference Center Chile Telefónica Mozambique Government 9

Romania 2K Telecom 21Vianet Star Base Russian Kazan Federal University Tencent Tianjin MDC Ulanqab Cloud First Affiliated Hospital of Zhengzhou University Ningxia Telecom Yangzhou Mobile Shanghai Zhoupu Sichuan Mobile Gui'an Base Zhejiang Telecom Bank of Oman, Middle East Hunan Broadcasting System Hunan e-government Cloud Myanmar Telenor Hong Kong Sun Network Singapore Singtel Zhuhai Branch, China Construction Bank The Prime Minister Office Jinan University Indonesia Lintasarta Guangzhou Metro Vipshop Australia Empired Ltd 10

Copyright Huawei Technologies Co., Ltd. 2017. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd. Trademark Notice, HUAWEI, and are trademarks or registered trademarks of Huawei Technologies Co., Ltd. Other trademarks, product, service and company names mentioned are the property of their respective owners. General Disclaimer The information in this document may contain predictive statements including, without limitation, statements regarding the future financial and operating results, future product portfolio, new technology, etc. There are a number of factors that could cause actual results and developments to differ materially from those expressed or implied in the predictive statements. Therefore, such information is provided for reference purpose only and constitutes neither an offer nor an acceptance. Huawei may change the information at any time without notice. HUAWEI TECHNOLOGIES CO., LTD. Huawei Industrial Base Bantian Longgang Shenzhen 518129, P.R. China Tel: +86-755-28780808 www.huawei.com