SECTION ELECTRICAL CONTROL DEVICES

Similar documents
SECTION ( ) LIGHTING CONTROL PANELBOARD

1510 MOTOR CONTROLLERS

SmartWire-DT In panel and on machine wiring solutions. Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

SECTION 16496E ATS MOLDED CASE WITH ATC 900 CONTROLLER

January 2001 Vol. 2, Ref. No. [0880] 10250T/E34 Series, Assembled Devices Momentary Pushbutton Units

CS7 Industrial Control Relays

Control Transformers Control transformers

SECTION SWITCHBOARDS

TECHNICAL SPECIFICATION FOR MEDIUM VOLTAGE METAL-CLAD SWITCHGEAR (15 KV)

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

WMS SUPPLEMENTARY PROTECTORS

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs

epro Canvas epro Canvas TM (Catalog No. CANVAS)

Crane Control Contactors and Relays

Operator Interface Business

SmartWire-DT In-panel and on-machine wiring solutions. Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators

SECTION MOTOR CONTROL CENTERS

E1 Plus Electronic Overload Relay

*REQUIRED* 169 Main Street 700 Plaza Middlesex Middletown, CT T: F:

Controls Enclosed Non-Combination Starters - PESW Series

CS7 Industrial Control Relays

PanelMate Power Series 1700 Frequently Asked Questions

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

LOW VOLTAGE BYPASS/ISOLATION BREAKER BASED AUTOMATIC TRANSFER SWITCHES SECTION 16496D

3.3. Control Relays and Timers

CS8 Industrial Control Relays

22mm Non Illuminated Metal Operators

Mini Contactors & Overloads

EXPRESS SETUP. PanelMate 1700 Series PanelMate Power Pro. Cutler-Hammer

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

78 Series Electromechanical Relay Selection Guide

920 Remote Control (RC) Switches

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

Industrial Monitors and Touch Monitors

Jockey Pump Controllers

UL 489 DIN rail branch circuit breakers

Contacts Contact Arrangement. 8-Pole Relay. 12-Pole Relay

Exercise 1-4. Contactors and Control Relays EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

Jockey Pump Controllers

SECTION PROGRAMMABLE LOGIC CONTROLLER (PLC)

PowerFlex 400 AC Drive Guide Specification

SECTION LOW-VOLTAGE VARIABLE FREQUENCY DRIVES

Allen-Bradley Drives

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

Free Standing Emergency Department DGL Project No SECTION OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY PART 1 - GENERAL

E-Series General Specifications

EXPRESS SETUP. PanelMate 1700 Series PanelMate Power Pro. Cutler-Hammer

Level-Lance Model 5400A

FTA750 LIMITED SERVICE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

LAUREL ELECTRONICS, INC.

9926 Series Branch Rated Circuit Breakers AC Version

SECTION MEDIUM VOLTAGE MOTOR CONTROLLERS LIMITAMP WITH POWER MANAGEMENT. A. Medium Voltage Motor Controllers with Power Management

Photoelectric Sensors 20 Series

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐. Non-Metallic Type 1/12K/IP66 Enclosure (KS7-C0C4R)

SECTION 16482A MOTOR CONTROL CENTERS LOW VOLTAGE (FREEDOM)

D64RP18 INSTRUCTION MANUAL N.O. N.C V AC/DC TEST/ RESET

SECTION PANELBOARDS

Vibration Switches viib

Revolutionizing control wiring

Bulletin 700-P, 700DC-P Industrial Relays

CITY OF BOISE SPECIFICATIONS FOR LIGHT EMITTING DIODE (LED) STREET LIGHTING Effective 1 Feb, 2018

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

SECTION DISCONNECT SWITCHES

Allen-Bradley Bulletin 100 Contactors

PS-4100 POWER SUPPLY MANUAL

(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum)

Certification according to CE. C-more Touchpanels:

V REG.-Nr. 3919, Z E214024

Atlas Industrial Flat Panel PC Monitors

PERFORMANCE SPECIFICATION

ASCO 920 Remote Control (RC) Switches

easyrelay Control Relays MFD-Titan Multi-Function Display

N2S and N2SC Series Control Stations

Time Delay Values (E-Series)

Safety Monitoring Relays

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

OpenHMI IWS Operator Interface Products

EXPRESS SETUP. PanelMate 3000 Series PanelMate Power Pro. Cutler-Hammer

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

Stellar Instruments. SC1 Controller & Display System. General User s Manual. Copyright 2013 Stellar Instruments 1

reliable company...caterpillar

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

Electric actuator for quarter-turn valves. For output torques to 17,700 lb. in.

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Miniature Circuit Breakers and Supplementary Protectors. Contents

Eaton s Innovative Technology Surge Suppression Guideform Specification Low Exposure DIVISION 16 SECTION 16289

Introduction Circuit Protection

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

Eaton s Innovative Technology Surge Suppression Guideform Specification High Exposure DIVISION 16 SECTION 16289

Certification according to CE. C-more Touchpanels:

SECTION DISTRIBUTION SWITCHBOARDS

GE Multilin 350 Feeder Protection Relay Specifications

TECHNICAL BROCHURE BCPNEMAST R0. NEMA Rated Three-Phase Starters BY EATON

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

Transcription:

ELECTRICAL CONTROL DEVICES PART 1 GENERAL 01 02 03 04 05 SCOPE The Contractor shall furnish and install, where indicated on the drawings, equipment with electrical control devices installed as specified herein and shown on the contract drawings. REFERENCES CSA UL SUBMITTALS FOR REVIEW/APPROVAL The following information shall be submitted to the Engineer: Product data sheets SUBMITTALS FOR CONSTRUCTION The following information shall be submitted for record purposes: Final as-built drawings and information for items listed in Paragraph 04, and shall incorporate all changes made during the manufacturing process QUALIFICATIONS For the equipment specified herein, the manufacturer shall be ISO 9001 or 9002 certifie The manufacturer of this equipment shall have produced similar electrical equipment for a minimum period of five (5) years. When requested by the Engineer, an acceptable list of installations with similar equipment shall be provided demonstrating compliance with this requirement. PART 2 PRODUCTS 2.01 MANUFACTURERS Eaton / Cutler-Hammer products * * The listing of specific manufacturers above does not imply acceptance of their products that do not meet the specified ratings, features and functions. Manufacturers listed above are not relieved from meeting these specifications in their entirety. Products in compliance with the * Note to Spe Writer Insert data in blanks 26 29 05-1 6/06

2.02 specification and manufactured by others not named will be considered only if pre-approved by the Engineer ten (10) days prior to bid date. CONTROL RELAYS D. Control Relays Electro-mechanical 600 V Industrial Control Relays shall be Eaton / Cutler-Hammer type D15, D26, AR or approved equal 2. Contacts shall be rated NEMA A600 with a continuous thermal rating of 10 amperes ac and NEMA P300/P600 with a continuous thermal rating of 5 amperes dc 3. Relays shall be available with interchangeable ac or dc magnetic coils 4. The Control Relays shall be 4-pole as standard and available in any fixed configuration of NO or NC contacts or have convertible contacts. Expansion of the number of available contacts shall be possible through the addition of top mount front deck adders. These adders shall be available in 2-pole or 4-pole units 5. The control relay shall also be capable of conversion to a solid-state or pneumatic timer by addition of a field installable timer attachment Control Relays Solid-State Addressable Relay (ARII). Where shown on the drawings, provide Addressable Relay(s) (ARII), Eaton / Cutler-Hammer type ARII or approved equal capable of being controlled from remote computer over the communications network. The ARII shall have two (2) status indicating circuits, which can be used to transmit the status of external device contacts to a personal computer or programmable logic controller over a twisted pair network up to 7,500 feet. The ARII shall be provided with the following features: One (1) Form C addressable contact shall be rated 115 to 120 Vac, 43.2-ampere make and 7.2-ampere break Three (3) hexadecimal selector switch dials to provide unique addresses for computer identification A light emitting diode (LED) to indicate when the relay is energized An LED shall be provided to indicate active communication status to the communications network e. Communications rate shall be selectable for 9600 baud or 1200 baud over twisted pair of #18 wires f. Relay operation powered from 120 Vac or 48- to 125 Vdc g. Operation suitable over a temperature range of 0 degrees C through 70 degrees. 2. Addressable relay shall have field-settable latch to allow the relay to turn OFF after 10 seconds if communications ON signal not received or to stay ON Breaker Control Relay Where shown on the drawings or herein specified, provide a Breaker Control Relay (BC) for use with electrically operated breakers and having communications capability for remote open or close of the breakers from a personal computer or programmable logic controller over a twisted pair network up to 7,500 feet. The BC shall be equal to Eaton / Cutler-Hammer type ADR Breaker Control Relay, having the following specified features and functions: 26 29 05-2 6/06

The BC shall be wired to the breaker close and trip coil circuits and serve as supervisory control relays. The BC shall be capable of being activated only from a remote computer by coded signal that selects the proper relay by its address and then commands the relay contacts to close or open. The BC shall have suitable hexadecimal wheels to field program its particular address. The BC shall include the ability to provide remote status indication over the same twisted pair of wires providing OPEN/CLOSE status by monitoring auxiliary contacts located on the breaker. For drawout breakers with Truck Operated Cell (TOC) switches, the BC shall also monitor the position of the TOC switch contacts The BC shall be capable of being powered by either 120 Vac or 48 to 125 Vdc The BC shall have a selectable baud rate of 1200 or 9600 The BC shall be capable of transmitting the following data for real-time display of breaker status: STATUS REASON BREAKER CELL POSITION OPEN NORMAL Connected CLOSED NORMAL Connected TRIP PROTECTIVE RELAY Connected OPEN TEST Test Position CLOSED TEST Test Position TRIP TEST Test Position 2.03 2.04 PUSHBUTTONS Pushbuttons and Pilot Devices shall be Eaton / Cutler-Hammer 30.5 mm, heavy-duty, oiltight type 10250T, E34, or approved equal. -- *OR-- Pushbuttons and Pilot Devices shall be Eaton / Cutler-Hammer 22.5 mm industrial heavyduty type EM22 or approval equal. Device bodies shall be zinc die cast with chrome plating or cathodic epoxy coating. Devices shall utilize a single panel gasket and provide integral grounding by means of either a built-in grounding terminal or a pointed grounding surface integral to the device. D. Devices shall be UL or CSA listed or CE marked for types 1, 2, 3, 3R, 4, 4X, 12 and 13 when mounted in a suitable enclosure with the same ratings. E. Devices shall have an operating temperature range of -17 degrees C to 60 degrees F. Pushbuttons and contact blocks shall have a published mechanical life of not fewer than 5,000,000 operations. SELECTOR SWITCHES Selector Switches shall be Eaton / Cutler-Hammer 30.5 mm, heavy-duty, oil-tight type 10250T, E34 or approved equal. -- *OR -- * Note to Spe Writer Select one 26 29 05-3 6/06

D. E. Selector Switches shall be Eaton/Cutler-Hammer 22.5 mm, industrial heavy-duty type EM22 or approved equal. Device bodies shall be zinc die cast with chrome plating or cathodic epoxy coating. Devices shall utilize a single panel gasket and provide integral grounding by means of either a built-in grounding terminal or a pointed grounding surface integral to the device. Devices shall be UL or CSA listed or CE marked for types 1, 2, 3, 3R, 4, 4X, 12 and 13 when mounted in a suitable enclosure with the same ratings. Devices shall have an operating temperature range of -17 degrees C to +60 degrees 2.05 2.06 INDICATING LIGHTS D. E. F. Indicating lights shall be Eaton / Cutler-Hammer 30.5 mm, heavy-duty, oil-tight type 10250T, E34 or approved equal. -- *OR -- Indicating lights shall be Eaton / Cutler-Hammer 22.5 mm industrial heavy-duty type EM22 or approved equal. Device bodies shall be zinc die cast with chrome plating or cathodic epoxy coating. Devices shall utilize a single panel gasket and provide integral grounding by means of either a built-in grounding terminal or a pointed grounding surface integral to the device. Devices shall be UL or CSA listed or CE marked for types, 1, 2, 3, 3R, 4, 4X, 12 and 13 when mounted in a suitable enclosure with the same ratings. Devices shall have an operating temperature range of -17 degrees C to 60 degrees Indicating lights shall be *[full voltage LED type] or [push-to-test transformer type]. Lens color shall be as indicated on the contract drawings. TIMERS Pneumatic Timers equal Pneumatic timers shall be Eaton / Cutler-Hammer type C320TP or approved 2. Pneumatic timers shall be available with DPST timed contacts. Output contacts shall be rated 6 A maximum make and 0.6 A maximum break at 600 Vac and 30 A maximum make and 3 A maximum break at 120 Vac 3. Pneumatic timers shall be available with adjustable timing ranges of 0.1 to 30 or 10 to 180 seconds 4. Pneumatic timers shall be convertible from OFF to ON Delay or vice-versa 5. Pneumatic timers must be capable of top mounting to NEMA Size 00 through 2 or IEC Size A through K Freedom starters or contactors and D15 control relays 2.07 CONTROL STATIONS Control Stations shall be Eaton / Cutler-Hammer type 10250 standard duty, heavy-duty, 10250T or approved equals. * Note to Spe Writer Select one 26 29 05-4 6/06

For applications exceeding NEMA Type 1, devices shall be suitable for NEMA Types 4X and 13. Shall be UL listed as complete assembly. 2.08 OPERATOR INTERFACE PANEL (O/I) Eaton/Cutler-Hammer Operator Interface Panel (O/I) Hardware O/Is shall be of modular design for easy installation and shall have the following features: Enclosure rated NEMA 4/NEMA 12 2. -- *OR -- Rated NEMA 4X Rated UL/cUL Class I Div 2 Groups A,B,C,D and CE Mark Impact-resistant protective window over display Field-replaceable flat panel backlight. O/Is shall have the following integrated touchscreen display characteristics: *[8.4-inch color TFT flat panel-vga] [12.1-inch color TFT flat panel-svga] [15.0-inch color TFT flat panel-xga]. Non-integrated (blind node) units shall support the following screen resolutions: VGA (640 x 480), SVGA (800 x 600), XGA (1024 x 768), SXGA (1280 x 1024) and UXGA (1600 x 1200) at full 32-bit color (16-bit on UXGA) 3. O/Is shall use touch screen as the operator's input device. O/Is must also support Microsoft compatible USB keyboard for alphanumeric entry functions. Operator control actions through the touchscreen must support the following features: Positive, two-step control or critical control operations and immediate one-touch control for non-critical operations such as page change or mode change. Field-replaceable touch screen Analog resistive 4-wire resolution. Eaton / Cutler-Hammer Operator Interface (O/I) Communications e. f. g. O/Is shall offer the following communications choices: Built-in PLC drivers for both serial and Ethernet communications protocols Simultaneous communication to multiple PLCs and PLC brands Optional High-speed interfaces through either PCMCIA or PCI bus. Network down/uploading of configurations, drivers and runtime firmware Dual serial ports. 10/100Base-T Ethernet communications Built-in OPC Server connectivity Eaton / Cutler-Hammer Operator Interface (O/I) Software and Configuration O/Is shall offer the following tools for creating and changing screen content: Advanced Windows-based configuration software Common look and feel across product line * Note to Spe Writer Select one 26 29 05-5 6/06

e. f. g. h. i. j. k. l. m. n. 2. e. ELECTRICAL CONTROL DEVICES Single configuration software for all products Fill-in-the-blank configuration Automatic conversion of existing configurations Context-sensitive help screens Pre-configured templates Indicator 2. Button 3. Readout 4. Bar 5. Display 6. Clock 7. Multiline Text 8. LED Indicator 9. Slales 10. Touch Areas 1 Images support for BMP, JPEG, WMF and EMF formats 12. Images support for Ethernet based Cognex and DVT vision system images. Document Viewer Window for display of PDF, JPEG, TXT, and HTML file types Windows Media Player support for MPG and MPEG file types Alarm and Event window Full library of Boolean logic and math operators Direct addressing of PLC data and OPC tags Ethernet transfers All documentation in HTML Help format O/Is shall provide the following graphical capabilities: Bitmap graphics (.bmp, jpg,.wmf and.emf formats) Object-based pixel graphics Dynamic object-based graphics Blinking colors for up to 16 different blink states and up to 3 different blink rates. Nondestructive updates 3. Operator Interface shall be Eaton / Cutler-Hammer type PanelMate epro PS or preapproved equal. 26 29 05-6 6/06