IP8 rating tested at 1.05kg/sq cm (15lb/sq in) 10m depth for weeks and.8kg/sq cm (10lb/sq in) 100m depth for hours IPK, Tested in accordance with DIN 0050/Part IPkk Water and dustproof to IP8 when mated,,,,,, and 5 pole A, V ac/dc pole screw terminal, pole screw terminal and crimp contacts 10A, V ac/dc pole screw terminal 5A, V ac/dc and pole screw terminal 5A, 150V ac/dc pole crimp contacts 5A, 50V ac/dc pole crimp and solder contacts 1A, 50V ac/dc 5 pole crimp and solder contacts Plug or socket connection in each body style Compact design Diameter over coupling ring 8mm Sealing caps available to maintain IP8 rating of unmated connectors body styles - flex cable, in-line flex cable, panel mount (front), panel mount (rear), mount, bulkhead and flange mount Leading earth contact for pole socket version Positive locating keyways - cannot be mis-connected Easy assembly - no special tools required on screw terminal versions Cable range from.5mm - mm Colour coded identification variants Pre-wired, overmoulded cable assemblies CCC, UL, CSA and VDE approvals EN008--5 Test Kb Salt Mist (Cyclic) Marine Severity Level 1 Circular Power Connectors 1
Flex Cable Connector PX01 Mates with In-Line Flex or Panel Mounting Versions Locking Ring Leading Earth on pole connectors Poles,,,,,,, 5 Standard Cable Acceptance ( to pole) -8mm,.5-mm with alternative glands 5 /Solder /Solder PX0/P PX01/P PX0/P PX08/P PX0/P PX05/P PX08/P PX0/P PX080/P PX0/S PX01/S PX0/S PX08/S PX0/S PX05/S PX08/S PX0/S PX080/S Inline Flex Cable Connector PX0 Mates with Flex or Panel Mounting Versions Locking Ring Leading Earth on pole connectors Poles,,,,,,, 5 Standard Cable Acceptance ( to pole) -8mm,.5-mm with alternative glands 5 /Solder /Solder PX0/P PX0/P PX08/P PX0/P PX00/P PX0/P PX0/P PX05/P PX081/P PX0/S PX0/S PX08/S PX0/S PX00/S PX0/S PX0/S PX05/S PX081/S Pre Wired Flex Cable Connector PX000 Overmoulded cable assemblies Up to 1mm dia cable with PVC or PU jackets PX000 flex cable connector Mates with in-line flex connector and all panel connectors Circular Power Connectors
Front Panel Mounting Connector Mates with Flex Cable Connector Front panel mounting Single Hole Fixing Poles,,,,,,, 5 PX00/P Poles Termin ation Pin Contacts Socket Contact Contacts 5 /Solder /Solder PX05/P PX00/P PX0/P PX0/P PX08/P PX0/P PX0/P PX0/P PX08/P PX05/S PX00/S PX0/S PX0/S PX08/S PX0/S PX0/S PX0/S PX08/S Rear Panel Mounting Connector Mates with Flex Cable Connector Rear panel mounting Single Hole Fixing Poles,,,,,, or 5 PX00/x/xx 5 /Solder /Solder PX00/P/0 PX00/P/0 PX008/P/0 PX00/P/0 PX00/P/0 PX00/P/0 PX008/P/0 PX008/P/ PX008/P/5 PX00/S/0 PX00/S/0 PX008/S/0 PX00/S/0 PX00/S/0 PX00/S/0 PX008/S/0 PX008/S/ PX008/S/5 Spring Loaded Sealing Cap IP5 rated Spring loaded Clip shut to seal For use with front of panel mounting connector types PX01 Circular Power Connectors
Mounting Connector Mates with Flex Cable connector Rear panel mounting No. poles:,,,, or 5 Pin or socket versions Pre-loaded Gold Plated contacts PX00/P/ 5 PX00/P/0 PX00/P/0 PX00/P/0 PX00/P/0 PX00/P/ PX00/P/5 PX00/S/0 PX00/S/0 PX00/S/0 PX00/S/0 PX00/S/ PX00/S/5 Bulkhead Flange Mounting Connector PX05/S 5 Mates with Flex Cable Connector Fixing Flange Poles,,,,,,, 5 Supplied with sealing gasket and screw sealing grommets /Solder /Solder PX05/P PX05/P PX08/P PX01/P PX058/P PX00/P PX0/P PX08/P PX08/P PX05/S PX05/S PX08/S PX01/S PX058/S PX00/S PX0/S PX08/S PX08/S Low Profile Flange Mounting Connector PX05/S 5 Flange Fixing Poles,,,,,,, 5 Mates with Flex Cable Connector Supplied with sealing gasket and screw sealing grommets /Solder /Solder PX0/P PX05/P PX081/P PX0/P PX0/P PX08/P PX0/P PX0/P PX08/P PX0/S PX05/S PX081/S PX0/S PX0/S PX08/S PX0/S PX0/S PX08/S Circular Power Connectors
Accessories Coloured Contact Inserts Coloured Inserts With or without matching gland nut Positive visual identification Available in; Black, Blue, Green, Grey, Light Grey, Red, White and Yellow Contact Inserts Colour Options Part No Blank BL GN GY LG RD WH YL Suffix Colour Black Blue Green Grey Light Grey Red White Yellow Insert/Gland Nut Combinations 1 Insert and Gland Nut Coloured Insert Only Coloured E.g. PX01/P/YL1 = Yellow insert and gland nut Contacts for and 5 Pole Inserts or Solder Pins and Sockets Gold Plated Current ratings: way: 5A, 50V 5 way: 1A, 50V Contacts - Solder & for and 5 pole Contacts (for 5 pole) (Supplied in packs of 10) Pins Sockets Contacts (for pole) (Supplied in packs of 10) Solder SA180/1 SA 1/1 Solder SA180 SA1 and 5 way contacts Pins Sockets SA8/1 SA/1 SA8 SA Assembly Tools PNo 105 and 10 Tools for,, and 5 pole crimp contacts Insertion/Extraction Tool for 5 pole contacts Tools Tool (5 pole) Tool ( pole) Positioner ( pole) Tool ( pole) Tool ( pole) pole positioner Insertion/Extraction Tool (5 pole) Insertion/Extraction Tool ( pole) Insertion/Extraction Tool ( pole) PNo. 105/1AMP PNo. 105 PNo. 105/5AMP PNo. 18 PNo. 1 PNo. 1/1 PNo. 10 PNo. 10/1 PNo. 10/ Cable Glands Pack of alternative cable glands to suit cables from.5 to mm dia. Cable Acceptance - Alternatives Gland Diameter -8mm.5-5mm 5-mm -mm Gland Pack Gland Part No. 0 SA 0/1 0/ SA5 Gland Colour Black Grey White Yellow Additional Suffix Standard for - pole Suffix /0 Suffix /05 Suffix /0* Pack of glands to suit cables.5-5mm, 5-mm & -mm dia SA5 *Note: -mm gland standard for 5 way, no suffix required. Includes additional black gland cage for.5-5mm dia. cable range. To order connector with alternative cable gland add suffix to part no. e.g. PX01/P/0 = PX01 pin connector with cable gland to suit -mm dia. cable. Cable Acceptance - Standard as supplied No. Contacts - Pole 5 Pole Cable Diameter or Type -8mm -mm Circular Power Connectors 5
Accessories Sealing Cap and Assembling Tool PX0 PX0 Maintains IP8 Rating of Unmated Connectors Can be used to remove Inserts PX0 for Flex Cable Connector PX0 for In-line Flex, Front Panel, Bulkhead and Flange mount connectors PX011 for and Rear Panel Mount connectors Rear of Panel Back Shell PX0 Provides environmental seal to rear of panel Standard cable acceptance -8mm,.5 to mm with alternative glands For use on front panel mounting connectors Replaces mounting nut in panel connector PVC Insulation Boot Shock protection for rear of connector Flammability Rating ULV-0 Fits Front Panel Mount Versions only PNo. 855 Cable Support Accessory Gives Extra Support to the Cable Suitable for 5-mm and -mm Cable Diameters PNo. Circular Power Connectors
Part No System PX0xxx X XX XX X Body Styles Contacts Type P = Pin S = Socket Cable Acceptance or /Rear Panel Mounting Flex Cable and In-line Flex Connectors cable acceptance use: Blank = -8mm (Black) standard for - pole 0 =.5-5mm (Grey) 05 = 5-mm (White) 0 = -mm (Yellow) (standard for 5 way, no suffix required) (PX00) and Rear Panel Mount connectors (PX008 and PX00) use: Insert/Gland Nut Colour Blank = Black BL = Blue GN = Green GY = Grey LG = Light Grey RD = Red WH = White YL = Yellow Insert/Gland Nut Colour Combination 1 = Insert and Gland Nut Coloured = Insert only Coloured 0 = pole 0 = pole 0 = pole = pole 0 = pole 0 = pole 0 = pole 5 = 5 pole Front Panel, Bulkhead and Flange Mount - not required: Examples: PX00/P/0= Panel connector, pin contacts, pole PX01/S = Flex Cable connector, socket contacts, pole PX0/P/0/BL = In-Line Flex Cable connector, pin contacts, pole, -mm cable acceptance, blue insert Layouts Sockets Contact Nos viewed from rear of panel Pins Contact Nos viewed from rear panel rear of panel PX00/S/0 PX00/S/0 PX00/P/0 PX00/P/0 PX00/S/0 PX00/S/0 PX00/P/0 PX00/P/0 PX00/S/ PX00/S/5 PX00/P/ PX00/P/5 Circular Power Connectors
Specifications Electrical: Mechanical: No. Poles: Current Rating: VDE UL, CSA Voltage Rating (ac/dc): Contact Resistance: Insulation Resistance: AC Breakdown voltage: Operating Temp. Range: Approvals: UL CSA VDE CCC Material: Body Mouldings: Inserts (-5 pole): PX00 PX008 PX00,, 5 A 10A 5A 5A 5A 1A 10A A A 5A 5A 1A V V V 150V 50V 50V <10mΩ (- Pole) <5mΩ ( Pole) <5mΩ (5 Pole) >10⁴MΩ @ 500V d.c. (- Pole) kv Pole - Pole (- Pole) kv Poles - Panel (Low Profile Flange and Panel Types - Pole).5kV Poles - Panel (Other Types - Pole) 0 C to +0 C E88 and E50 LR808-0 0018 01101005001 1 Amp Rated 0110100500 5 Amp Rated 0110100500 10 Amp Rated 01101005005 Amp Rated Overmoulded cable assemblies approvals to customer requirements. Glass Filled Polyamide ULHB Polyamide ULV-0 Polyamide ULV-0 Polyamide ULV-0 Polyamide ULV-0 Sealing: Salt Mist: Cable Acceptance: - Pole - standard gland: - Pole - alternative glands: 5 Pole - standard gland: 5 Pole - alternative glands: Contact Accommodation: and pole screw terminals: pole crimp:, and pole: pole: pole: 5 pole: Terminations: - Pole: Pole: Pole: Pole: 5 Pole: Tightening Torques: Flex Mounting/In-Line: Panel Mounting: IPK, Tested in accordance with DIN 0050/Part IPkk IP8, EN 05:1+A:01 Tested @ 1.05kg/sq.cm. (15lb/sq.in.) 10m depth for weeks. EN 05:1 +A:01 Tested @.8kg/sq.cm. (10lb/sq.in.) 100m depth for hours. EN008--5 Test Kb Salt Mist (Cyclic) Marine Severity Level 1-8mm dia.5-mm dia -mm dim.5-mm dim mm (AWG) max 1.0-1.5mm (1-18AWG) max 1.5mm (1AWG) max 0.-0.1mm (-AWG) 0.mm (-AWG) max 0.-0.1mm (-AWG) Terminals Terminals & Contacts & Solder Contacts & Solder Contacts Gland Nut: 1.1Nm (10lbf.in.) Rear Fixing Nut: 1.Nm (15lbf.in.) Front Fixing Nut: 1.Nm (.lbf.in.) Overmoulded types: Body Mouldings: Flammability Rating: Contacts: Terminal: ( pole): /Solder (+5 Pole): BNC inserts: BNC contacts: Polyurethane ULV-HB Brass, Nickel Plated Copper Alloy, Tin Plated Copper Alloy, Gold Plated (0.1μm on Nickel) Brass, Nickel Plated Brass, Silver Plated Surface/Bulkhead and Low Profile Flange Mounting: Sealings Caps/Locking Ring: Rear thread, Front Panel Connector: Thread, Front Panel Connector: Fixing s (using washers supplied) 0.Nm (lbf.in.) 1.1Nm (10lbf.in.) M x 1.0-H M5 x 1.0-H RoHS Compliant 8 Circular Power Connectors
Sealed Inline Cable Joiner Cable Joiner IP8 & IPk Rating For Sealed In-Line Connections Standard Cable Acceptance -8mm Cable Range.5-mm (using alternative glands) Supplied with, or 8 way Terminal Block Available Moulded in Black or Orange PX0 Specifications PX0 PX0/POLE, POLE, 8POLE POLE Configurations Rating: 1A, 50V a.c. 10A, 50V a.c. Wire Termination: way Terminal Block,, 8 way Terminal Block Conductor Accommodation:.5mm² max (1AWG) 1.5mm² max (1AWG) Cable Acceptance: -8mm dia alternative glands available on request -8mm dia alternative glands available on request Material: Glass Filled Polyamide UL-HB Glass Filled Polyamide UL-V0 Sealing: IP8 to BSEN 05 : 1 1.05kg/sq.cm. (15lbs/sq.in.) 10m depth for weeks IP8 to BSEN 05 : 1 1.05kg/sq.cm. (15lbs/sq.in.) 10m depth for weeks IPk to DIN 0050- IPk to DIN 0050- Salt Mist EN008--5 Test Kb Salt Mist (Cyclic) Marine Severity Level 1 EN008--5 Test Kb Salt Mist (Cyclic) Marine Severity Level 1 Operating Temp. Range: 0 C to +0 C 0 C to +0 C Colour: Black Orange (Add /OR to PNo.) Black Orange (Add /OR to PNo.) RoHS Compliant Compliant Examples PX0 Pole -8mm Black. PX0/0 Pole.5-5.0mm Black. PX0/0/OR Pole.5-5.0mm Orange. PX0/POLE Pole -8mm Black. PX0/POLE/0 Pole.5-5.0mm Black. PX0/8POLE/0/OR 8 Pole.5-5.0mm Orange. PX0 XPOLE XX XX Part No Blank = Pole POLE = Pole POLE = Pole 8POLE = 8 Pole Blank = -8mm 0 =.5-5mm 05 = 5-mm 0 = -mm Blank = Black OR = Orange Circular Power Connectors
PX0 WIRING AND ASSEMBLY INSTRUCTIONS 1.. Strip wires to dimensions shown. Assemble components parts onto cable as shown, then connect wires to terminal block. ENSURING WIRES CONNECTED INTO ONE SIDE OF TERMINAL BLOCK MATCH WIRES CONNECTED INTO THE OTHER SIDE. Wire stripping details i.e. Brown to Brown (Live) Blue to Blue (Neutral) Green/Yellow to Green/Yellow (Earth). Bring the two body mouldings together ensuring the O ring is correctly located in groove then lock together with locking ring, ensure ring is fully tightened. Put gland cage over gland and push fully home into its appropriate body then fully tighten gland nuts.. To ensure a good seal, all surfaces must be completely free of dust, grease or any other contamination. THIS CABLE CONNECTOR IS SUITABLE FOR USE WITH LOADS NOTEXCEEDING 1 AMPS USING 1.5mm CABLE ALWAYS USE WITH SUPPLY PROTECTED BY AN RCD, IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN. DANGER DISCONNECT MAINS SUPPLY BEFORE DISMANTLING CONNECTOR 0 Circular Power Connectors