CA Workload Automation ESP Edition CA RS 1309 Service List

Similar documents
CA Workload Automation ESP Edition CA RS 1312 Service List

CA Workload Automation ESP Edition CA RS 1504 Service List

CA Workload Automation ESP Edition CA RS 1501 Service List

CA Workload Automation ESP Edition CA RS 1604 Service List

CA Workload Automation ESP Edition CA RS 1406 Service List

CA Workload Automation ESP Edition CA RS 1609 Service List

CA Workload Automation ESP Edition CA RS 1507 Service List

CA Workload Automation ESP Edition CA RS 1412 Service List

CA Workload Automation ESP Edition CA RS 1410 Service List

CA JCLCheck Workload Automation CA RS 1404 Service List

CA JCLCheck Workload Automation CA RS 1403 Service List

CA JCLCheck Workload Automation CA RS 1407 Service List

CA JCLCheck Workload Automation CA RS 1411 Service List

CA Top Secret Security for z/os CA RS 1310 Service List

CA PDSMAN PDS Library Management CA RS 1404 Service List

CA Top Secret Security for z/os CA RS 1404 Service List

CA JCLCheck Workload Automation CA RS 1605 Service List

CA NetMaster CA RS 1609 Service List

CA View CA RS 1312 Service List

CA Top Secret Security for z/os CA RS 1803 Service List

CA Vtape Virtual Tape System CA RS 1309 Service List

CA Top Secret Security for z/os CA RS 1710 Service List

CA File Master Plus for IMS CA RS 1306 Service List

CA InterTest Batch CA RS 1404 Service List

CA InterTest Batch CA RS 1510 Service List

CA MIM Resource Sharing CA RS 1511 Service List

CA File Master Plus for IMS CA RS 1403 Service List

CA IDMS CA RS 1403 Service List

CA Allocate DASD Space and Placement CA RS 1610 Service List

CA Datacom/DB CA RS 1507 Service List

CA Datacom/DB CA RS 1602 Service List

CA JCLCheck Workload Automation CA RS 1412 Service List

CA NetMaster CA RS 1509 Service List

CA Endevor Software Change Manager CA RS 1606 Service List

CA XCOM Data Transport for z/os CA RS 1411 Service List

CA Mainframe Application Tuner CA RS 1403 Service List

CA XCOM Data Transport for z/os CA RS 1312 Service List

CA Workload Automation CA 7 Edtion CA RS 1509 Service List

CA PDSMAN PDS Library Management CA RS 1309 Service List

CA JCLCheck Workload Automation CA RS 1408 Service List

CA OPS/MVS for JES CA RS 1511 Service List

CA Top Secret Security for z/os CA RS 1509 Service List

CA Datacom/DB CA RS 1305 Service List

CA Mainframe Application Tuner CA RS 1404 Service List

CA IMS Tools CA RS 1409 Service List

CA IDMS CA RS 1705 Service List

CA JCLCheck Workload Automation CA RS 1705 Service List

CA Disk Backup and Restore CA RS 1509 Service List

CA Vantage Storage Resource Manager CA RS 1509 Service List

CA TLMS Tape Management CA RS 1404 Service List

CA NetMaster CA RS 1711 Service List

CA Datacom/DB CA RS 1412 Service List

CA MIM Resource Sharing CA RS 1512 Service List

CA IDMS CA RS 1612 Service List

CA Datacom/AD CA RS 1405 Service List

CA NetMaster CA RS 1505 Service List

CA JCLCheck Workload Automation CA RS 1507 Service List

CA XCOM Data Transport for z/os CA RS 1509 Service List

CA IDMS CA RS 1612 Service List

CA SYSVIEW Performance Management CA RS 1608 Service List

CA Workload Automation CA 7 Edtion CA RS 1709 Service List

CA Mainframe Application Tuner CA RS 1410 Service List

CA InterTest Batch CA RS 1408 Service List

CA Datacom/AD CA RS 1704 Service List

CA TPX Session Management CA RS 1403 Service List

CA Common Services CA RS 1702 Service List

CA Mainframe Application Tuner CA RS 1505 Service List

CA IDMS CA RS 1611 Service List

CA IDMS CA RS 1611 Service List

CA Disk Backup and Restore CA RS 1712 Service List

CA SYSVIEW Performance Management CA RS 1510 Service List

CA Common Services CA RS 1612 Service List

CA Workload Automation CA 7 Edtion CA RS 1606 Service List

CA Datacom/AD CA RS 1408 Service List

CA Datacom/AD CA RS 1305 Service List

CA 1 Tape Management CA RS 1404 Service List

CA SYSVIEW Performance Management CA RS 1605 Service List

CA Gen Encyclopedia Server / Implementation ToolSet CA RS 1408 Service List

CA LDAP CA RS 1312 Service List

CA ACF CA RS 1711 Service List

CA Datacom/DB CA RS 1410 Service List

CA ACF CA RS 1605 Service List

CA TLMS Tape Management CA RS 1709 Service List

CA Workload Automation CA 7 Edtion CA RS 1510 Service List

CA Datacom/DB CA RS 1704 Service List

CA InterTest Batch CA RS 1309 Service List

CA DB2 Tools 20.0 **INCREMENTAL** 1 CA RS 1706 Service List

CA XCOM Data Transport for z/os CA RS 1408 Service List

CA PDSMAN PDS Library Management CA RS 1411 Service List

CA Endevor Software Change Manager CA RS 1403 Service List

CA ACF CA RS 1501 Service List

CA Mainframe Application Tuner CA RS 1505 Service List

CA 1 Tape Management CA RS 1403 Service List

CA JCLCheck Workload Automation CA RS 1610 Service List

CA IDMS CA RS 1607 Service List

CA File Master Plus CA RS 1603 Service List

CA JCLCheck Workload Automation CA RS 1406 Service List

CA Top Secret Security for z/os CA RS 1412 Service List

CA Datacom/AD CA RS 1701 Service List

CA ACF CA RS 1512 Service List

Transcription:

CA Workload Automation ESP Edition 11.4 1 CA RS 1309 Service List Description Hiper 11.4 RO56050 IRRNNNI MESSAGES CAUSING INCORRECT JCLERROR STATUS RO56572 ESP MASTER CHECKPOINT MAY FILL UP DURING STARTUP RO56585 CONSOLE TRACKING DADSM OBTAIN RO56797 ABEND S0C4 IN CYBRM013 RO56897 NOTIFY INDICATES ENDED INSTEAD OF FAILED RO56916 EXTERNAL OF SELFCOMPL TASK IS POSTED WHEN FORCED COMPLETE RO56977 INADVERTENT ESP JOB RESTARTS RO57146 ABEND U2999 IN MAPGEN JOB RO57215 INCORRECT BATCH SIMULATE NORUN RC 0 RO57226 LOW BATCH RC AFTER AN ERROR IN SADGEN RO57234 BYPASSED EXTMON OBJECT NOT RELEASING SUCCESSORS RO57345 ERROR MESSAGES BROWSING JCL FROM WORKSTATION RO57413 WORKSTATION SERVER U1013 RO57479 ABEND SD23 ON SEND COMMAND RO57516 ENABLE FILTERING BY TAG AND SUBAPPL IN LSAR RO57523 CSF SHOWS A WRONG RETURN CODE FOR ABENDED JOB RO57528 EXTERNAL DETAILS INFORMATION RO57530 APPLS IN REXXON EXEC STATUS RO57584 INSERTING JOB AFTER APPLEND CAUSES LOOP RO57604 TEST SYSTEM PROXY TASK ABEND RO57641 ABEND S0C4 IN TRACEPRT COMMAND RO57689 UNPOPULATED MNSYS VARIABLE RO57700 CA LICENSING SMF PRODUCT INFORMATION RO57764 LONG COND STATEMENTS TRUNCATED RO58092 SUPPORT ESP IN MULTI-TASKING TSO ENVIRONMENT RO58148 MONITORING FOR MANUAL JOBS WITH JCL ERRORS RO58196 VSAM RECORD LENGTH DISCREPANCY WITH INTERNAL RECORD LENGTH RO58198 JOB INDEX FILE SYNCHRONIZATION RO58290 HEALTHCK COMMAND COMPATIBILITY RO58385 INTERNAL OPER COMMAND HANG WAITING FOR DSPMODE TASKS COMMAND RO58422 ESP MASTER ABENDS WITH U1013, S0C4, S0C6 RO58436 APPLICATION CAN STAY IN APPLWAIT AFTER ESP4174W RO58511 ABEND S0C4 IN WKSTART AND WORKDAY COMMANDS RO58621 APPLICATION SCOREBOARD PURGE PROBLEM RO58765 JOB WITH INVERSE RESOURCE REQUEST MAY STAY IN RESWAIT RO58796 CHECKING FOR SPURIOUS ENDDOS RO59082 S0C4 ABEND IN FAILOVER MANAGER RO59147 SELECTION OF HIGH COMPLETION CODE DISREGARDS CCCHK RO59158 LOCAL JOB JCL ERROR NOT DETECTED RO59247 MESSAGE 1062I DESCRIPTION ADDED RO59300 S122 IF SUBSYSTEM STARTED DURING LMP INITIALIZATION RO59301 ABEND S0C4 DUE TO SYMBOLIC VARIABLE SUBSTRING RO59306 WRONG COND STATEMENT USED WHEN RESET THROUGH MGRMSG RO59341 APPLICATION SLOT OVERLAYS NOT DETECTED BY CYBESUT1 RO59353 ESP609E PARAMETER NOT VALID RO59627 LEAK OF SEND COMMAND RESPONSE ELEMENTS RO59689 PLATFORM-SPECIFIC PASSWORDS FOR PROXY_JOB RO59759 EAV COMPATIBILITY WITH ESP RO59791 MANUAL TRIGJOB NOT POSTED WHEN JCL ERROR The CA RS 1309 service count for this release is 49

CA Workload Automation ESP Edition 11.3 2 CA RS 1309 Service List Description Hiper 11.3 RO57013 Bypassed EXTMON WOB not releasing successors RO57014 EXTERNAL DETAILS INFORMATION RO57015 The Application Monitor displays invalid value in the RO57139 ESPWSS906E INVLD KWRD ERROR MSG ON ATTEMPT TO BROWSE JCL RO57258 Workstation started task abended on a U1013 RO57379 INSERTING JOB AFTER APPLEND CAUSES LOOP RO57381 SD23 ABEND ON SEND COMMAND RO57392 TRACEPRT COMMAND CAN CAUSE S0C4 RO57503 LONG COND STATEMENTS TRUNCATED RO57505 MULTIPLE AJ INSERTS RESULT IN 0C4 ABEND RO57506 ESP MASTER ABENDS WITH U1013, S0C4, S0C6. RO57914 APPLICATION CAN STAY IN APPLWAIT AFTER ESP4174W RO58052 VSAM RECORD LENGTH DISCREPANCY WITH INTERNAL RECORD LENGTH RO58054 SUPPORT ESP IN MULTI-TASKING TSO ENVIRONMENT RO58461 CA Licensing Product SMF Information RO58571 Application scoreboard purge bug RO58647 Checking for spurious ENDDOs RO58807 S0C4 abend in Failover Manager RO58939 Application slot overlays not detected by CYBESUT1 RO58940 Incorrect dynamic allocation failure message RO58997 Manual TRIGJOB not posted when JCL error RO58998 TDRs for STEPEND monitor events may fill up ESP checkpoint RO59132 JOB WITH INVERSE RESOURCE REQUEST MAY STAY IN RESWAIT RO59249 LLMP command response License field misalignment RO59486 "Unable to find password" message issued incorrectly RO59487 Platform-specific passwords for PROXY_JOB RO59614 ESP609E PARAMETER NOT VALID RO59820 WRONG COND STATEMENT USED WHEN RESET THROUGH MGRMSG RO60322 NEW MSG FOR LOADAGDF WITH TEST The CA RS 1309 service count for this release is 29

CA Workload Automation ESP Edition 3 CA RS 1309 Service List for CD7YB30 FMID Service Description Hiper CD7YB30 RO57013 Bypassed EXTMON WOB not releasing successors RO57014 EXTERNAL DETAILS INFORMATION RO57015 The Application Monitor displays invalid value in the RO57139 ESPWSS906E INVLD KWRD ERROR MSG ON ATTEMPT TO BROWSE JCL RO57379 INSERTING JOB AFTER APPLEND CAUSES LOOP RO57381 SD23 ABEND ON SEND COMMAND RO57503 LONG COND STATEMENTS TRUNCATED RO57505 MULTIPLE AJ INSERTS RESULT IN 0C4 ABEND RO57506 ESP MASTER ABENDS WITH U1013, S0C4, S0C6. RO57914 APPLICATION CAN STAY IN APPLWAIT AFTER ESP4174W RO58571 Application scoreboard purge bug RO58807 S0C4 abend in Failover Manager RO58939 Application slot overlays not detected by CYBESUT1 RO58997 Manual TRIGJOB not posted when JCL error RO58998 TDRs for STEPEND monitor events may fill up ESP checkpoint RO59132 JOB WITH INVERSE RESOURCE REQUEST MAY STAY IN RESWAIT RO59486 "Unable to find password" message issued incorrectly RO59487 Platform-specific passwords for PROXY_JOB RO59820 WRONG COND STATEMENT USED WHEN RESET THROUGH MGRMSG RO60322 NEW MSG FOR LOADAGDF WITH TEST The CA RS 1309 service count for this FMID is 20

CA Workload Automation ESP Edition 4 CA RS 1309 Service List for CD7YB40 FMID Service Description Hiper CD7YB40 RO56050 IRRNNNI MESSAGES CAUSING INCORRECT JCLERROR STATUS RO56572 ESP MASTER CHECKPOINT MAY FILL UP DURING STARTUP RO56585 CONSOLE TRACKING DADSM OBTAIN RO56797 ABEND S0C4 IN CYBRM013 RO56897 NOTIFY INDICATES ENDED INSTEAD OF FAILED RO56916 EXTERNAL OF SELFCOMPL TASK IS POSTED WHEN FORCED COMPLETE RO56977 INADVERTENT ESP JOB RESTARTS RO57146 ABEND U2999 IN MAPGEN JOB RO57215 INCORRECT BATCH SIMULATE NORUN RC 0 RO57226 LOW BATCH RC AFTER AN ERROR IN SADGEN RO57234 BYPASSED EXTMON OBJECT NOT RELEASING SUCCESSORS RO57345 ERROR MESSAGES BROWSING JCL FROM WORKSTATION RO57413 WORKSTATION SERVER U1013 RO57479 ABEND SD23 ON SEND COMMAND RO57516 ENABLE FILTERING BY TAG AND SUBAPPL IN LSAR RO57523 CSF SHOWS A WRONG RETURN CODE FOR ABENDED JOB RO57528 EXTERNAL DETAILS INFORMATION RO57530 APPLS IN REXXON EXEC STATUS RO57584 INSERTING JOB AFTER APPLEND CAUSES LOOP RO57604 TEST SYSTEM PROXY TASK ABEND RO57641 ABEND S0C4 IN TRACEPRT COMMAND RO57689 UNPOPULATED MNSYS VARIABLE RO57700 CA LICENSING SMF PRODUCT INFORMATION RO57764 LONG COND STATEMENTS TRUNCATED RO58092 SUPPORT ESP IN MULTI-TASKING TSO ENVIRONMENT RO58148 MONITORING FOR MANUAL JOBS WITH JCL ERRORS RO58196 VSAM RECORD LENGTH DISCREPANCY WITH INTERNAL RECORD LENGTH RO58198 JOB INDEX FILE SYNCHRONIZATION RO58290 HEALTHCK COMMAND COMPATIBILITY RO58385 INTERNAL OPER COMMAND HANG WAITING FOR DSPMODE TASKS COMMAND RO58422 ESP MASTER ABENDS WITH U1013, S0C4, S0C6 RO58436 APPLICATION CAN STAY IN APPLWAIT AFTER ESP4174W RO58511 ABEND S0C4 IN WKSTART AND WORKDAY COMMANDS RO58621 APPLICATION SCOREBOARD PURGE PROBLEM RO58765 JOB WITH INVERSE RESOURCE REQUEST MAY STAY IN RESWAIT RO58796 CHECKING FOR SPURIOUS ENDDOS RO59082 S0C4 ABEND IN FAILOVER MANAGER RO59147 SELECTION OF HIGH COMPLETION CODE DISREGARDS CCCHK RO59158 LOCAL JOB JCL ERROR NOT DETECTED RO59247 MESSAGE 1062I DESCRIPTION ADDED RO59300 S122 IF SUBSYSTEM STARTED DURING LMP INITIALIZATION RO59301 ABEND S0C4 DUE TO SYMBOLIC VARIABLE SUBSTRING RO59306 WRONG COND STATEMENT USED WHEN RESET THROUGH MGRMSG RO59341 APPLICATION SLOT OVERLAYS NOT DETECTED BY CYBESUT1 RO59353 ESP609E PARAMETER NOT VALID RO59627 LEAK OF SEND COMMAND RESPONSE ELEMENTS RO59689 PLATFORM-SPECIFIC PASSWORDS FOR PROXY_JOB RO59759 EAV COMPATIBILITY WITH ESP RO59791 MANUAL TRIGJOB NOT POSTED WHEN JCL ERROR The CA RS 1309 service count for this FMID is 49

CA Workload Automation ESP Edition 5 CA RS 1309 Service List for CD9EB30 FMID Service Description Hiper CD9EB30 RO57258 Workstation started task abended on a U1013 RO57392 TRACEPRT COMMAND CAN CAUSE S0C4 RO58052 VSAM RECORD LENGTH DISCREPANCY WITH INTERNAL RECORD LENGTH RO58054 SUPPORT ESP IN MULTI-TASKING TSO ENVIRONMENT RO58461 CA Licensing Product SMF Information RO58647 Checking for spurious ENDDOs RO58940 Incorrect dynamic allocation failure message RO59249 LLMP command response License field misalignment RO59614 ESP609E PARAMETER NOT VALID The CA RS 1309 service count for this FMID is 9

CA Workload Automation ESP Edition 11.4 6 CA RS 1309 - PTF RO56050 11.4 RO56050 RO56050 M.C.S. ENTRIES = ++PTF (RO56050) IRRNNNI MESSAGES CAUSING INCORRECT JCLERROR STATUS Security message IRRnnnI that contains keywords VERIFICATION FAILED can mark a job completed with JCLERROR status, even if the job has already started and is running. This fix makes ESP ignore IRRnnn messages for such jobs. After receiving IRRnnnI message, ESP marks a job as complete with the JCLERROR status. At the same time, the real job is up and running. The job is incorrectly completed by ESP and the JCLERROR status is set to it. None. PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1364 Copyright (C) 2013 CA. All rights reserved. R00317-D7Y114-SP1 DESC(IRRNNNI MESSAGES CAUSING INCORRECT JCLERROR STATUS). PRE ( RO50241 RO55377 RO55795 ) SUP ( RO54904 TR54904 TR55951 TR56050 )

CA Workload Automation ESP Edition 11.4 7 CA RS 1309 - PTF RO56572 11.4 RO56572 RO56572 M.C.S. ENTRIES = ++PTF (RO56572) ESP MASTER CHECKPOINT MAY FILL UP DURING STARTUP There could be a situation when the master checkpoint data set is filled up by tracking records from the proxies if the proxies are started before the master. It may cause a deadlock between the application and tracking managers when the application manager needs to wait for checkpoint space while the tracking manager waits for the application manager to complete its initialization. Messages indicating that the checkpoint file is full. No events, jobs, applications are processed by ESP. ESP outage. ESP cold start. PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1343 Copyright (C) 2013 CA. All rights reserved. R00327-D7Y114-SP1 DESC(ESP MASTER CHECKPOINT MAY FILL UP DURING STARTUP). SUP ( TR56572 )

CA Workload Automation ESP Edition 11.4 8 CA RS 1309 - PTF RO56585 11.4 RO56585 RO56585 M.C.S. ENTRIES = ++PTF (RO56585) CONSOLE TRACKING DADSM OBTAIN The IBM Console Tracking Facility reports a potential DADSM OBTAIN error by Encore program CYBRM000. The error will occur if the Encore EXH data set is EAS-eligible and the z/os release is V1.R12 or later. This fix implements proper EAV (Extended Address Volume) support for the Encore EXH data set. The following error message is issued by the Console Tracking Facility: ---TRACKING INFORMATION---- -VALUE-- JOBNAME PROGNAME+OFF-- ASID NUM SMS-E:1 DADSM OBTAIN C10001 DXYWMAWA CYBRM000 20802 91 1 The Encore EXH data set will be unusable if it resides on an EAV (Extended Address Volume) and the z/os release is V1.R12 or later. None. PRODUCT(S) AFFECTED: CA Workload Automation Restart Option ESP Edition Release 11.4 ESPWA 1378 Copyright (C) 2013 CA. All rights reserved. R00328-D7Y114-SP1 DESC(CONSOLE TRACKING DADSM OBTAIN). PRE ( RO49741 ) SUP ( TR56585 )

CA Workload Automation ESP Edition 11.4 9 CA RS 1309 - PTF RO56797 11.4 RO56797 RO56797 M.C.S. ENTRIES = ++PTF (RO56797) ABEND S0C4 IN CYBRM013 Sometimes Encore allocates a bigger buffer for processing a job execution history request. Occasionally, not all pointers are updated with the new buffer address and this can lead to a S0C4 abend. This fix ensures that all pointers are correctly updated after the new buffer is allocated. ESP abends with S0C4 abend in the load module CYBRM011. The title of the SVC dump reports "subtask ABEND0C4 in CYBRM013". S0C4 abend. None. PRODUCT(S) AFFECTED: CA Workload Automation Restart Option ESP Edition Release 11.4 ESPWA 1380 Copyright (C) 2013 CA. All rights reserved. R00330-D7Y114-SP1 DESC(ABEND S0C4 IN CYBRM013). PRE ( RO49741 RO55479 ) SUP ( TR56797 )

CA Workload Automation ESP Edition 11.4 10 CA RS 1309 - PTF RO56897 11.4 RO56897 RO56897 M.C.S. ENTRIES = ++PTF (RO56897) NOTIFY INDICATES ENDED INSTEAD OF FAILED Notifications sent due to NOTIFY FAILURE contain the word ENDED rather than FAILED. For the jobs that abended, failed with CCCHK or JCL error, the notification would indicate that the job ENDED. None. None. PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1369 Copyright (C) 2013 CA. All rights reserved. R00333-D7Y114-SP1 DESC(NOTIFY INDICATES ENDED INSTEAD OF FAILED). PRE ( RO50241 RO55377 RO56050 ) SUP ( RO54904 TR54904 TR55951 TR56897 )

CA Workload Automation ESP Edition 11.4 11 CA RS 1309 - PTF RO56916 11.4 RO56916 RO56916 M.C.S. ENTRIES = ++PTF (RO56916) EXTERNAL OF SELFCOMPL TASK IS POSTED WHEN FORCED COMPLETE When USERMOD 30 is on, the external of SELFCOMPLETING TASK will be posted if the TASK is forced complete. New USERMOD 91 has been introduced to disable posting externals of the SELFCOMPLETING TASK. External of the SELFCOMPLETING TASK is posted complete when the home job is forced complete. The user cannot force complete the application without posting externals. None. PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1375 Copyright (C) 2013 CA. All rights reserved. R00335-D7Y114-SP1 DESC(EXTERNAL OF SELFCOMPL TASK IS POSTED WHEN FORCED COMPLETE). SUP ( RO48789 RO51846 RO52128 RO52192 RO56370 TR48789 TR51846 TR51949 TR52128 TR52192 TR53881 TR54135 TR56370 TR56417 TR56916 )

CA Workload Automation ESP Edition 11.4 12 CA RS 1309 - PTF RO56977 11.4 RO56977 RO56977 M.C.S. ENTRIES = ++PTF (RO56977) INADVERTENT ESP JOB RESTARTS When a job with JOBID=0 is selected in CSF for resubmission, Encore restart panel CYBESS10 incorrectly offers to restart the job (by filling the field 'Restart ===> Y' in the CYBESS10 panel). After applying the fix the Encore restart panel will correctly offer to resubmit the job (by filling the field 'Restart ===> N' in the CYBESS10 panel). The Encore restart panel CYBESS10 incorrectly offers to restart the job instead of to resubmit it, if JOBID=0. The Encore restart panel offers the user to restart a job instead of to resubmit it. Change the 'Restart ===> Y' option field in the Encore restart panel CYBESS10 to 'Restart ===> N'. PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1381 Copyright (C) 2013 CA. All rights reserved. R00338-D7Y114-SP1 DESC(INADVERTENT ESP JOB RESTARTS). PRE ( RO50380 RO55270 ) SUP ( RO54132 RO54217 TR52533 TR54110 TR54132 TR54217 TR56814 TR56977 )

CA Workload Automation ESP Edition 11.4 13 CA RS 1309 - PTF RO57146 11.4 RO57146 RO57146 M.C.S. ENTRIES = ++PTF (RO57146) ABEND U2999 IN MAPGEN JOB This abend occurs in the MAPGEN job if the length of the parameter list on the RUN/NORUN statement exceeds 4080 characters. MAPGEN job ends with ABEND U2999. Inability to use JOBMAP and JOBTREE commands. Code multiple RUN/NORUN statements instead of one. PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1367 Copyright (C) 2013 CA. All rights reserved. R00343-D7Y114-SP1 DESC(ABEND U2999 IN MAPGEN JOB). PRE ( RO56359 ) SUP ( RO51917 TR51917 TR56317 TR56481 TR57041 TR57050 TR57052 TR57053 TR57146 )

CA Workload Automation ESP Edition 11.4 14 CA RS 1309 - PTF RO57215 11.4 RO57215 RO57215 M.C.S. ENTRIES = ++PTF (RO57215) INCORRECT BATCH SIMULATE NORUN RC 0 When the SIMULATE command is used in a batch job and the simulated workload object contains a NORUN statement with invalid schedule criteria, the batch job wrongly completes with return code zero. The batch job completes with return code zero even when the workload object simulation includes an error in a NORUN statement. A user is not notified when the SIMULATE command contains errors. Each batch job output needs to be checked to verify whether the simulation completed successfully. PRODUCTS AFFECTED: CA Workload Automation ESP Edition 11.4 ESPWA 1376 Copyright (C) 2013 CA. All rights reserved. R00344-D7Y114-SP1 DESC(INCORRECT BATCH SIMULATE NORUN RC 0). PRE ( RO56359 RO57146 ) SUP ( RO51917 TR51917 TR56481 TR57052 TR57215 )

CA Workload Automation ESP Edition 11.4 15 CA RS 1309 - PTF RO57226 11.4 RO57226 RO57226 M.C.S. ENTRIES = ++PTF (RO57226) LOW BATCH RC AFTER AN ERROR IN SADGEN Errors encountered during simulation of events in SADGEN processing are not reflected in the condition code of the SADGEN batch job. This fix uses a recently introduced operator command, BATCHRC MAXSEV LEGACY. SADGEN batch jobs will now return a non-zero condition code in cases where there were WARNING/ERROR/SEVERE messages during processing. To exploit this feature, the BATCHRC MAXSEV initialization paramenter has to be coded in the initialization parameter library used for the SADGEN batch job run. SADGEN ends with RC=0 even when there are errors in the execution. The SADGEN processing might be wrongly considered as successful. Check the SYSPRINT output of SADGEN job for any errors. PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1385 Copyright (C) 2013 CA. All rights reserved. R00346-D7Y114-SP1 DESC(LOW BATCH RC AFTER AN ERROR IN SADGEN). PRE ( RO54033 RO57146 ) SUP ( TR57053 TR57226 )

CA Workload Automation ESP Edition 11.4 16 CA RS 1309 - PTF RO57234 11.4 RO57234 RO57234 M.C.S. ENTRIES = ++PTF (RO57234) BYPASSED EXTMON OBJECT NOT RELEASING SUCCESSORS When a job monitored by the EXTMON workload object in an ESP application is bypassed by a remote user, the status of the EXTMON workload object is correctly changed to BYPASSED, but successors are not released. This fix ensures that all successor workload objects are properly released after the EXTMON workload object is bypassed. CSF shows status BYPASSED for a bypassed EXTMON workload object, but successors still have non-zero hold counts and will not run. Workload is not processed as expected N/A PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1388 Copyright (C) 2013 CA. All rights reserved. R00347-D7Y114-SP1 DESC(BYPASSED EXTMON OBJECT NOT RELEASING SUCCESSORS). SUP ( RO48789 RO51846 RO52128 RO52192 RO56370 RO56916 TR48789 TR51846 TR51949 TR52128 TR52192 TR53881 TR54135 TR56370 TR56417 TR56916 TR57234 )

CA Workload Automation ESP Edition 11.4 17 CA RS 1309 - PTF RO57345 11.4 RO57345 RO57345 M.C.S. ENTRIES = ++PTF (RO57345) ERROR MESSAGES BROWSING JCL FROM WORKSTATION When attempting to browse, from Workstation, the JCL of a job with the same name as a DSTRIG object with a qualifier, in the same application, multiple "906E INVALID KEYWORD" error messages are displayed. Multiple "906E INVALID KEYWORD" error messages are displayed when trying to browse a job's JCL from Workstation. User cannot browse the JCL of a job from Workstation. None. PRODUCTS AFFECTED: CA ESP Workload Automation ESP Edition r11.4 ESPWA 1392 Copyright (C) 2013 CA. All rights reserved. R00349-D7Y114-SP1 DESC(ERROR MESSAGES BROWSING JCL FROM WORKSTATION). SUP ( RO55156 TR45665 TR54997 TR55156 TR57345 )

CA Workload Automation ESP Edition 11.4 18 CA RS 1309 - PTF RO57413 11.4 RO57413 RO57413 M.C.S. ENTRIES = ++PTF (RO57413) WORKSTATION SERVER U1013 Workstation Server abended U1013 during logoff processing of a Workstation user. Workstation Server abend U1013 Restart required. None. PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1395 Copyright (C) 2013 CA. All rights reserved. R00350-D7Y114-SP1 DESC(WORKSTATION SERVER U1013). SUP ( TR57413 )

CA Workload Automation ESP Edition 11.4 19 CA RS 1309 - PTF RO57479 11.4 RO57479 RO57479 M.C.S. ENTRIES = ++PTF (RO57479) ABEND SD23 ON SEND COMMAND An abend SD23 can occur when a SEND command is issued with text length equal to 124 characters. ESP master abend SD23. ESP master outage. None. PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1396 Copyright (C) 2013 CA. All rights reserved. R00351-D7Y114-SP1 DESC(ABEND SD23 ON SEND COMMAND). PRE ( RO50049 RO56359 ) SUP ( TR57479 )

CA Workload Automation ESP Edition 11.4 20 CA RS 1309 - PTF RO57516 11.4 RO57516 RO57516 M.C.S. ENTRIES = ++PTF (RO57516) ENABLE FILTERING BY TAG AND SUBAPPL IN LSAR The LSAR command will accept two new optional parameters, TAG and SUBAPPL: TAG{(tag1 {tag2}...)} SUBAPPL{(subappl1 {subappl2}...)} The values of tag1, tag2,... and subappl1, subappl2,... are used to restrict the LSAR report to records with matching tags and/or subappl fields. Wildcard characters, hyphen and asterisk, are accepted.an empty value or a value containing a delimiter must be enclosed in quotes: SUBAPPL('') TAG('MONTHLY JOBS') Filtering by TAG/SUBAPPL is available in all types of LSAR reports. When TAG and/or SUBAPPL is coded in an LSAR command for a regular or a PROJECTED report, the corresponding column is added to the report output. Specifying TAG/SUBAPPL without values adds the attribute to the ouput without additional filtering. The FORECASTING ACTIVITY dialog (option S from the main entry panel) will also accept the new parameters. N/A. None. PRODUCTS AFFECTED: CA Workload Automation ESP Edition 11.4 ESPWA 1384 Copyright (C) 2013 CA. All rights reserved. R00352-D7Y114-SP1 DESC(ENABLE FILTERING BY TAG AND SUBAPPL IN LSAR). SUP ( RO48787 TR48787 TR57217 TR57516 )

CA Workload Automation ESP Edition 11.4 21 CA RS 1309 - PTF RO57523 11.4 RO57523 RO57523 M.C.S. ENTRIES = ++PTF (RO57523) CSF SHOWS A WRONG RETURN CODE FOR ABENDED JOB During initialization of a job, the JES initiator could not obtain a region required to run the step and a system 822 abend is received. However, CSF will show the highest return code from the previous steps or RC=0 for a single step job. A job abended with S822 but ESP reports the highest return code from the previous steps or RC=0 for a single step job. Wrong RC is used. MN variables don't show the correct values. None. PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1371 Copyright (C) 2013 CA. All rights reserved. R00353-D7Y114-SP1 DESC(CSF SHOWS A WRONG RETURN CODE FOR ABENDED JOB). PRE ( RO50241 RO55377 RO56050 ) SUP ( RO54904 RO56897 TR54904 TR55951 TR56897 TR56900 TR56918 TR57523 )

CA Workload Automation ESP Edition 11.4 22 CA RS 1309 - PTF RO57528 11.4 RO57528 RO57528 M.C.S. ENTRIES = ++PTF (RO57528) EXTERNAL DETAILS INFORMATION ESP does not properly propagate the start and end times of the home job to the externals with SCHEDULED or SCOPE set. This causes CA Workload Automation Workstation to display the current time instead. After applying the fix, CA Workload Automation Workstation displays the correct times for the externals with SCHEDULED or SCOPE set. CA Workload Automation Workstation shows wrong start and end times for the externals with SCHEDULED or SCOPE parameter set. Confusion when the external has been completed. NONE PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1389 Copyright (C) 2013 CA. All rights reserved. R00354-D7Y114-SP1 DESC(EXTERNAL DETAILS INFORMATION). SUP ( RO48789 RO51846 RO52128 RO52192 RO56370 RO56916 RO57234 TR48789 TR51846 TR51949 TR52128 TR52192 TR53881 TR54135 TR56370 TR56417 TR56916 TR57234 TR57240 TR57528 )

CA Workload Automation ESP Edition 11.4 23 CA RS 1309 - PTF RO57530 11.4 RO57530 RO57530 M.C.S. ENTRIES = ++PTF (RO57530) APPLS IN REXXON EXEC STATUS The Application Monitor displays an invalid value in the Status_ field of a complete application, when the last job in the application is a LINK PROCESS and ESP REXX is executed for that last LINK job. The Application Monitor Status_ field of a complete application shows on the master: 'Ended at ', where blanks are displayad instead of the completion time. shows on the proxy: 'Ended at 16:29 NOV15', when the proxy is missing the notification about the last link REXX execution, or 'REXXON EXEC=20m10s', when the proxy was notified about the last link REXX start, but not notified about its end. The number of REXXON calls, displayed by the LAE commands, is different on the master and proxies. Incorrect message displayed in the ApplMon Status_ field. None. PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1387 Copyright (C) 2013 CA. All rights reserved. R00355-D7Y114-SP1 DESC(APPLS IN REXXON EXEC STATUS). PRE ( RO55270 RO56359 RO57146 ) SUP ( RO48789 RO51846 RO51917 RO52128 RO52192 RO53420 RO56370 RO56916 RO57215 RO57234 RO57528 TR48789 TR51846 TR51917 TR51949 TR52128 TR52192 TR53420 TR53881 TR54135 TR56370 TR56417 TR56481 TR56916 TR57052 TR57215 TR57234 TR57240 TR57528 TR57530 )

CA Workload Automation ESP Edition 11.4 24 CA RS 1309 - PTF RO57584 11.4 RO57584 RO57584 M.C.S. ENTRIES = ++PTF (RO57584) INSERTING JOB AFTER APPLEND CAUSES LOOP When inserting a job into an application after another job that is a successor of APPLEND, the inserted job becomes a predecessor of APPLEND and a loop occurs. The jobs stay in PREDWAIT state indefinitely. Messages 6221W and 6222I are displayed. The workload couldn't be resumed. None. PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1398 Copyright (C) 2013 CA. All rights reserved. R00357-D7Y114-SP1 DESC(INSERTING JOB AFTER APPLEND CAUSES LOOP). SUP ( TR57584 )

CA Workload Automation ESP Edition 11.4 25 CA RS 1309 - PTF RO57604 11.4 RO57604 RO57604 M.C.S. ENTRIES = ++PTF (RO57604) TEST SYSTEM PROXY TASK ABEND When Encore processes the job end request for a job with a large number of dynamic allocations, exceeding the number of slots available in the EXH file, it issues the appropriate message (ID 7187), but it mistakenly escapes the job end signal process. This results in the memory cleaning mechanism being broken. The EXH record for this kind of job remains in memory after the job finishes executing, it can cause 0C4 abend. The EXH record should stay in memory for the job live time only. OC4 abend, or memory dump containing the orphan EXH record. OC4 abend, or unpredictable. None. PRODUCT(S) AFFECTED: CA Workload Automation Restart Option ESP Edition Release 11.4 ESPWA 1399 Copyright (C) 2013 CA. All rights reserved. R00358-D7Y114-SP1 DESC(TEST SYSTEM PROXY TASK ABEND). PRE ( RO49741 ) SUP ( TR57604 )

CA Workload Automation ESP Edition 11.4 26 CA RS 1309 - PTF RO57641 11.4 RO57641 RO57641 M.C.S. ENTRIES = ++PTF (RO57641) ABEND S0C4 IN TRACEPRT COMMAND The TRACEPRT command may cause a S0C4 abend in Workstation Server or the TSO client if an invalid trace data set is specified. This fix checks the validity of the trace data set before accessing it. Abend S0C4 in Workstation Server or TSO client. Workstation Server outage or TSO client crash. Ensure the TRACEPRT command specifies a valid trace data set. PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1397 Copyright (C) 2013 CA. All rights reserved. R00359-D7Y114-SP1 DESC(ABEND S0C4 IN TRACEPRT COMMAND). SUP ( RO50831 RO51375 TR50826 TR50831 TR51348 TR51375 TR57539 TR57641 )

CA Workload Automation ESP Edition 11.4 27 CA RS 1309 - PTF RO57689 11.4 RO57689 RO57689 M.C.S. ENTRIES = ++PTF (RO57689) UNPOPULATED MNSYS VARIABLE The value of the variable MNSYS is not populated correctly. This can leed to errors in the monitor routines. Incorrect or empty variable MNSYS() is passed to the monitor routine. Error message ESP528E is issued. The monitor routine cannot process wrongly formatted variables. The error message ESP528E is issued. None. PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1373 Copyright (C) 2013 CA. All rights reserved. R00360-D7Y114-SP1 DESC(UNPOPULATED MNSYS VARIABLE). PRE ( RO50241 RO55377 RO56050 ) SUP ( RO54904 RO56897 RO57523 TR54904 TR55951 TR56897 TR56900 TR56918 TR57523 TR57689 )

CA Workload Automation ESP Edition 11.4 28 CA RS 1309 - PTF RO57700 11.4 RO57700 RO57700 M.C.S. ENTRIES = ++PTF (RO57700) CA LICENSING SMF PRODUCT INFORMATION When a CA licensing check occurs for the ESP base product and its components, product and version information will be provided to CA Common Services to be included in the SMF type 89 record written when ESP is launched. The additional information will help to more easily identify ESP product components in an IBM IFAURP utility report for all CA products. In an IBM IFAURP utility report, ESP version information is missing and ESP product information is cryptic. There may be some difficulty to accurately determine from an IBM IFAURP utility report which ESP components have been launched. None. PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1346 Copyright (C) 2013 CA. All rights reserved. R00361-D7Y114-SP1 DESC(CA LICENSING SMF PRODUCT INFORMATION). PRE ( RO54908 RO55270 ) SUP ( TR55430 TR55614 TR57700 )

CA Workload Automation ESP Edition 11.4 29 CA RS 1309 - PTF RO57764 11.4 RO57764 RO57764 M.C.S. ENTRIES = ++PTF (RO57764) LONG COND STATEMENTS TRUNCATED COND statements are allowed to be longer than 256 characters. ESP was truncating the statements after 256 characters. Jobs left in PREDWAIT state. Unexplained syntax errors. CSF display may look like: ApplName Gen# Job Name Job Qual CCode Jobno P Node Job Status ICTX87PA 10 ICTOK ~0000002 - TASK PREDWAIT WAITING, HC=1 ICTX87PA 10 MORWI08T ~0000001 0 22941 COMPLETE COMPLETED AT 10.05 22 ESP Job log may have entries such as: ESP027E (STEPRC('G.LX0432',4) OR STEPRC('G.LX0432',0:1)) AND STEPRC('H.LX0432 ESP004E INVALID STATEMENT SYNTAX COND statement failure. None. PRODUCT(S) AFFECTED: CA Workload Automation ESP Edition Release 11.4 ESPWA 1279 Copyright (C) 2013 CA. All rights reserved. R00362-D7Y114-SP1 DESC(LONG COND STATEMENTS TRUNCATED). PRE ( RO56359 RO57146 RO57530 ) SUP ( RO48789 RO51846 RO51917 RO52128 RO52192 RO56370 RO56916 RO57215 RO57234 RO57528 TR48789 TR51846 TR51917 TR51949 TR52128 TR52192 TR52483 TR53881 TR54135 TR56370 TR56417 TR56481 TR56916 TR57052 TR57215 TR57234 TR57240 TR57528 TR57764 )

CA Workload Automation ESP Edition 11.4 30 CA RS 1309 - PTF RO58092 11.4 RO58092 RO58092 M.C.S. ENTRIES = ++PTF (RO58092) SUPPORT ESP IN MULTI-TASKING TSO ENVIRONMENT This fix introduces an internal change to support module ESP when it is invoked by third party products that use a multi-tasking TSO environment. Customer reported that BMC's Mainview AutoOperator got into a loop while running a REXX that invokes ESP. Outage. None. PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1405 Copyright (C) 2013 CA. All rights reserved. R00365-D7Y114-SP1 DESC(SUPPORT ESP IN MULTI-TASKING TSO ENVIRONMENT). SUP ( TR58092 )

CA Workload Automation ESP Edition 11.4 31 CA RS 1309 - PTF RO58148 11.4 RO58148 RO58148 M.C.S. ENTRIES = ++PTF (RO58148) MONITORING FOR MANUAL JOBS WITH JCL ERRORS When a manual job is tracked by a TRACKDEF definition that specifies a model where a MONITOR group or generic monitor events are defined, that manual job must trigger those monitor events. However, when there was a JCL error for a manual job, it does not trigger monitor events. This fix implements processing of monitor events for manual jobs with JCL errors. No expected monitor events are triggered. Monitoring not working as designed for manual jobs with JCL errors. N/A PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1406 Copyright (C) 2013 CA. All rights reserved. R00366-D7Y114-SP1 DESC(MONITORING FOR MANUAL JOBS WITH JCL ERRORS). PRE ( RO50241 RO55377 RO56050 ) SUP ( RO54904 RO56897 RO57523 RO57689 TR54904 TR55951 TR56897 TR56900 TR56918 TR57523 TR57689 TR58148 )

CA Workload Automation ESP Edition 11.4 32 CA RS 1309 - PTF RO58196 11.4 RO58196 RO58196 M.C.S. ENTRIES = ++PTF (RO58196) VSAM RECORD LENGTH DISCREPANCY WITH INTERNAL RECORD LENGTH ESP can internally use a larger record length than the actual record length of a VSAM file in some circumstances. This discrepancy can occur when a VSAM file is REPROed into a new VSAM file with a smaller LRECL. This situation can lead to VSAM errors and possible loss of currently used data: ESP276E VSAM xxxx ERROR CODE nn ON DATA SET yyyy DABRC=08 DABERRCD=6C This fix ensures that the internally used record length is not larger than the VSAM LRECL for each VSAM read. 'ESP276E VSAM xxxx ERROR CODE nn ON DATA SET yyyy' message is issued with DABRC=08 and DABERRCD=6C. Other diagnostic messages may follow. A dump will be captured automatically. Possible loss of currently processed data. Recreation of the affected VSAM file or copying an old VSAM file into a new one with a larger LRECL. PRODUCT(S) AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1408 Copyright (C) 2013 CA. All rights reserved. R00368-D7Y114-SP1 DESC(VSAM RECORD LENGTH DISCREPANCY WITH INTERNAL RECORD LENGTH). PRE ( RO51836 ) SUP ( RO48783 RO51485 RO55793 TR48783 TR51472 TR51485 TR55793 TR58196 )

CA Workload Automation ESP Edition 11.4 33 CA RS 1309 - PTF RO58198 11.4 RO58198 RO58198 M.C.S. ENTRIES = ++PTF (RO58198) JOB INDEX FILE SYNCHRONIZATION There is a rare possibility that the job index file is not properly reserved when records are read for update. This can lead to potential synchronization problems. In particular, error message 903E can issued by ESP as a result of internal checks. This PTF fixes this problem. Early warning is message 903E (ESP stays up). Update of some records in job index file may be not synchronized, which can lead to processing errors. N/A PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1409 Copyright (C) 2013 CA. All rights reserved. R00369-D7Y114-SP1 DESC(JOB INDEX FILE SYNCHRONIZATION). PRE ( RO50241 RO55377 RO56050 ) SUP ( RO54904 RO56897 RO57523 RO57689 RO58148 TR54904 TR55951 TR56897 TR56900 TR56918 TR57523 TR57689 TR58148 TR58198 )

CA Workload Automation ESP Edition 11.4 34 CA RS 1309 - PTF RO58290 11.4 RO58290 RO58290 M.C.S. ENTRIES = ++PTF (RO58290) HEALTHCK COMMAND COMPATIBILITY The 11.3 version of the HEALTHCK command has operand NAME referencing the IBM Health Checker STC name. In 11.4 this name is supplied automatically, so the old operand NAME has been removed from the HEALTHCK command structure. That causes an initialization time error when the old version of the initialization parameter has been used. For example, HEALTHCK NAME(HCHECK). The old operand NAME is now allowed in the 11.4 HEALTHCK command for compatibility with 11.3. ESP906E INVALID KEYWORD, NAME(HCHECK) ESP804W PARAMETER ERROR ON FOLLOWING STATEMENT FROM ESPPARM FILE ESP803W HEALTHCK NAME(HCHECK) *050 LZ113802A REENTER ENTIRE STATEMENT, 'CANCEL' OR 'END' Initialization interruption. Reply without NAME operand: R 50,HEALTHCK PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1412 Copyright (C) 2013 CA. All rights reserved. R00370-D7Y114-SP1 DESC(HEALTHCK COMMAND COMPATIBILITY). PRE ( RO50049 ) SUP ( TR58290 )

CA Workload Automation ESP Edition 11.4 35 CA RS 1309 - PTF RO58385 11.4 RO58385 RO58385 M.C.S. ENTRIES = ++PTF (RO58385) INTERNAL OPER COMMAND HANG WAITING FOR DSPMODE TASKS COMMAND If an OPER command is issued in the subsystem address space at the same time an OPER DSPMODE TASKS command is being processed, then a subsystem hang may occur. Subsystem hang. Subsystem must be cancelled and restarted. Avoid issuing OPER DSPMODE TASKS command. PRODUCT(S) AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1379 Copyright (C) 2013 CA. All rights reserved. R00372-D7Y114-SP1 DESC(INTERNAL OPER COMMAND HANG WAITING FOR DSPMODE TASKS COMMAND). PRE ( RO51349 RO54908 RO55270 ) SUP ( RO57700 TR55430 TR55614 TR56800 TR56974 TR57700 TR58385 )

CA Workload Automation ESP Edition 11.4 36 CA RS 1309 - PTF RO58422 11.4 RO58422 RO58422 M.C.S. ENTRIES = ++PTF (RO58422) ESP MASTER ABENDS WITH U1013, S0C4, S0C6 The ESP master may abend if the APPLBUF value in the ESP initialization parameters is below 3,133,432, and the ATR size grows over the APPLBUF figure. ESP master abends. ESP outage. Increase APPLBUF. PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1404 Copyright (C) 2013 CA. All rights reserved. R00373-D7Y114-SP1 DESC(ESP MASTER ABENDS WITH U1013, S0C4, S0C6). PRE ( RO57530 RO57764 ) SUP ( RO48789 RO51846 RO52128 RO52192 RO56370 RO56916 RO57234 RO57528 TR48789 TR51846 TR51949 TR52128 TR52192 TR53881 TR54135 TR56370 TR56417 TR56916 TR57234 TR57240 TR57528 TR58081 TR58422 )

CA Workload Automation ESP Edition 11.4 37 CA RS 1309 - PTF RO58436 11.4 RO58436 RO58436 M.C.S. ENTRIES = ++PTF (RO58436) APPLICATION CAN STAY IN APPLWAIT AFTER ESP4174W ESP completes the oldest active application generation unconditionally when there are too many active generations and a new application generation is requested, but do not remove the WAIT status. This can lead to a situation when the whole generation stream stays in APPLWAIT if the application is defined with WAIT parameter. With this fix, ESP will remove the WAIT when completes the oldest active generation. Applications stay in APPLWAIT even when there is no active application. Application is not processing. The oldest generation is lost every time when a new generation is created. Applications reaching maximum concurrent active generations can be defined with a variable application name, for example APPL MYAPPL%ESPSMN. PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1416 Copyright (C) 2013 CA. All rights reserved. R00374-D7Y114-SP1 DESC(APPLICATION CAN STAY IN APPLWAIT AFTER ESP4174W). PRE ( RO57530 RO57764 ) SUP ( RO48789 RO51846 RO52128 RO52192 RO56370 RO56916 RO57234 RO57528 RO58422 TR48789 TR51846 TR51949 TR52128 TR52192 TR53881 TR54135 TR56370 TR56417 TR56916 TR57234 TR57240 TR57528 TR58081 TR58422 TR58436 )

CA Workload Automation ESP Edition 11.4 38 CA RS 1309 - PTF RO58511 11.4 RO58511 RO58511 M.C.S. ENTRIES = ++PTF (RO58511) ABEND S0C4 IN WKSTART AND WORKDAY COMMANDS When an invalid operand more than two characters is specified in the WKSTART or WORKDAYS command, an abend S0C4 usually occurs. In addition, when an invalid operand is specified in the WKSTART or WORKDAYS command and an abend does not occur, the error message is not routed to the command issuer. Abend S0C4. Subsystem outage. Do not issue the WKSTART or WORKDAYS command with an invalid operand. PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1419 Copyright (C) 2013 CA. All rights reserved. R00375-D7Y114-SP1 DESC(ABEND S0C4 IN WKSTART AND WORKDAY COMMANDS). PRE ( RO54033 RO57226 ) SUP ( TR58511 )

CA Workload Automation ESP Edition 11.4 39 CA RS 1309 - PTF RO58621 11.4 RO58621 RO58621 M.C.S. ENTRIES = ++PTF (RO58621) APPLICATION SCOREBOARD PURGE PROBLEM Purging application scoreboard elements may result in incorrect scheduling of purge requests for proxies, resulting later in abend S0C3. This problem is highly conditional and depends on the exact timing of other events, making it a relatively rare problem. However, it is more likely during a proxy startup, when the entire scoreboard is transferred from the master to the proxy. This fix corrects this problem. ESP is down due to abend S0C3. Disruption of ESP processing N/A PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1421 Copyright (C) 2013 CA. All rights reserved. R00377-D7Y114-SP1 DESC(APPLICATION SCOREBOARD PURGE PROBLEM). SUP ( TR58621 )

CA Workload Automation ESP Edition 11.4 40 CA RS 1309 - PTF RO58765 11.4 RO58765 RO58765 M.C.S. ENTRIES = ++PTF (RO58765) JOB WITH INVERSE RESOURCE REQUEST MAY STAY IN RESWAIT Intermittently, a job with inverse resource request remains in RESWAIT status when the available count is equal to zero. It happens when this job enters RESFILE prior to the other jobs that use up the resource. The following example illustrates this problem: 1. Resource R1 is defined as AVAIL(1) DEPLETABLE 2. The first application has a job with RESOURCE ADD(^R1) The job goes into RESWAIT as expected. 3. The second application has the same job with RESOURCE ADD(1,R1) This job runs as expected and depletes the resource, but the job from #2 remains in RESWAIT even though the available count of R1 is zero. A job with inverse resource request remains in RESWAIT even though the resource's avalable count is zero. Inability to use inverse resource requests Issue OPER RESREFR command to take the job out of RESWAIT. PRODUCTS AFFECTED: CA Workload Automation EE r11.3. CA Workload Automation ESP Edition r11.4. ESPWA 1420 Copyright (C) 2013 CA. All rights reserved. R00381-D7Y114-SP1 DESC(JOB WITH INVERSE RESOURCE REQUEST MAY STAY IN RESWAIT). PRE ( RO48860 ) SUP ( TR48242 TR48841 TR48854 TR58765 )

CA Workload Automation ESP Edition 11.4 41 CA RS 1309 - PTF RO58796 11.4 RO58796 RO58796 M.C.S. ENTRIES = ++PTF (RO58796) CHECKING FOR SPURIOUS ENDDOS This PTF ensures the integrity of DO/ENDDO statements in ESP procedures. The feature has an effect only when usermod 190 is on. For each ENDDO coded out of sequence (without a preceding DO statement), error message 322E will be issued and the application will not be generated. However, when usermod 190 is off the behavior is not changed (out of sequence ENDDOs are ignored). Note that usermod 190 also ensures integrity of JOB/ENDJOB statements. ESP ignores spurious ENDDO statements, rather than reporting a bug (out of sequence ENDDO). If there is a spurious ENDDO in an application, which is followed by a DO statement without closing ENDDO, ESP fails to report missing ENDDO too. Applications may not execute as intended Review applications and change it to make DO/ENDDO always consistent. PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1424 Copyright (C) 2013 CA. All rights reserved. R00382-D7Y114-SP1 DESC(CHECKING FOR SPURIOUS ENDDOS). SUP ( TR58796 )

CA Workload Automation ESP Edition 11.4 42 CA RS 1309 - PTF RO59082 11.4 RO59082 RO59082 M.C.S. ENTRIES = ++PTF (RO59082) S0C4 ABEND IN FAILOVER MANAGER Failover Manager uses an incorrect address of a workload object message with an invalid format while writing it to a log. It results in S0C4 abend. ESP abends with S0C4. Workload processing disruptions N/A PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1426 Copyright (C) 2013 CA. All rights reserved. R00383-D7Y114-SP1 DESC(S0C4 ABEND IN FAILOVER MANAGER). SUP ( TR59082 )

CA Workload Automation ESP Edition 11.4 43 CA RS 1309 - PTF RO59147 11.4 RO59147 RO59147 M.C.S. ENTRIES = ++PTF (RO59147) SELECTION OF HIGH COMPLETION CODE DISREGARDS CCCHK A job failed by CCCHK due to a particular return code may not show that code if a non-failing but higher completion code was produced by another step. CSF status for a failed job may display a non-failing completion code. A job with CCCHK RC(4) FAIL may have the status FAILED, CC 12, CCFAIL although code 12 is not causing the failure. The status is shown incorrectly. PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1429 Copyright (C) 2013 CA. All rights reserved. R00385-D7Y114-SP1 DESC(SELECTION OF HIGH COMPLETION CODE DISREGARDS CCCHK). PRE ( RO50241 RO55377 RO56050 ) SUP ( RO54904 RO56897 RO57523 RO57689 RO58148 RO58198 TR54904 TR55951 TR56897 TR56900 TR56918 TR57523 TR57689 TR58148 TR58198 TR59147 )

CA Workload Automation ESP Edition 11.4 44 CA RS 1309 - PTF RO59158 11.4 RO59158 RO59158 M.C.S. ENTRIES = ++PTF (RO59158) LOCAL JOB JCL ERROR NOT DETECTED Occasionally it can happen that a JCL error is not detected for a locally submitted job. This fix corrects the processing of tracking data that comes out of order. The status of a locally submitted job is sometimes not updated even if the job failed with a JCL error in JES. The status of a job is not updated in CSF. None. PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1430 Copyright (C) 2013 CA. All rights reserved. R00386-D7Y114-SP1 DESC(LOCAL JOB JCL ERROR NOT DETECTED). PRE ( RO50241 RO55377 RO56050 ) SUP ( RO54904 RO56897 RO57523 RO57689 RO58148 RO58198 RO59147 TR54904 TR55951 TR56897 TR56900 TR56918 TR57523 TR57689 TR58148 TR58198 TR59147 TR59158 )

CA Workload Automation ESP Edition 11.4 45 CA RS 1309 - PTF RO59247 11.4 RO59247 RO59247 M.C.S. ENTRIES = ++PTF (RO59247) MESSAGE 1062I DESCRIPTION ADDED The message description added. ---------------- Message: 1062I P-NODE NOT DEFINED Explanation: The DUEOUT command requires specifying a positional parameter P-NODE. This informational message will be issued in event simulation if the P-NODE specified in the DUEOUT command is not defined in the jobindex via the DEFPN command. System Action: Simulation terminates with this informational message, if the P-NODE in the DUEOUT statement has not been defined. User Response: Ensure that the P-NODE name specified in the positional parameter of the DUEOUT command is intended. ---------------- PRODUCT(S) AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1433 Copyright (C) 2013 CA. All rights reserved. R00389-D7Y114-SP1 DESC(MESSAGE 1062I DESCRIPTION ADDED). SUP ( TR59247 )

CA Workload Automation ESP Edition 11.4 46 CA RS 1309 - PTF RO59300 11.4 RO59300 RO59300 M.C.S. ENTRIES = ++PTF (RO59300) S122 IF SUBSYSTEM STARTED DURING LMP INITIALIZATION If a CA Workload Automation ESP Edition subsystem is started while the CA Resource Initialization Module CARIMC is initializing the CA License Management Prorgam, an abend S122 may occur, even though the subsystem has not been cancelled. Subsystem abend S122. Possible confusion. Start subsystems only after CAIRIMC initialization has completed. PRODUCTS AFFECTED: CA Workload Automation ESP Edition r11.4 S122 WHEN SUBSYSTEM STARTED DURING LMP INITIALIZATION ESPWA 1400 Copyright (C) 2013 CA. All rights reserved. R00392-D7Y114-SP1 DESC(S122 IF SUBSYSTEM STARTED DURING LMP INITIALIZATION). PRE ( RO54908 RO55270 RO58385 ) SUP ( RO57700 TR55430 TR55614 TR57700 TR59300 )

CA Workload Automation ESP Edition 11.4 47 CA RS 1309 - PTF RO59301 11.4 RO59301 RO59301 M.C.S. ENTRIES = ++PTF (RO59301) ABEND S0C4 DUE TO SYMBOLIC VARIABLE SUBSTRING Substring notation for a character symbolic variable does not work properly when the length of the variable is more than 256. If the higher substring index is also more than 256 then the substring is truncated. If the lower index is more than 256 it results in a S0C4 abend. This fix removes the 256-length limitation and ensures correct substring operation without abend. ESP is down due to abend S0C4. ESP TSO session is down if simulating. Disruption of ESP processing. Application cannot be processed. N/A PRODUCT(S) AFFECTED: CA Workload Automation ESP Edition r11.4 ESPWA 1428 Copyright (C) 2013 CA. All rights reserved. R00393-D7Y114-SP1 DESC(ABEND S0C4 DUE TO SYMBOLIC VARIABLE SUBSTRING). SUP ( TR59301 )

CA Workload Automation ESP Edition 11.4 48 CA RS 1309 - PTF RO59306 11.4 RO59306 RO59306 M.C.S. ENTRIES = ++PTF (RO59306) WRONG COND STATEMENT USED WHEN RESET THROUGH MGRMSG ESP uses the incorrect COND statement string when it is RESET by the MGRMSG command. This will cause a job with the reset COND statement to stay in predecessor wait status, but only for COND strings longer than 255 characters. This fix ensures that the correct COND string is used. Jobs left in PREDWAIT state. Unexplained syntax errors. COND statement failure. None. PRODUCT(S) AFFECTED: CA Workload Automation EE r11.3 CA Workload Automation ESP Edition r11.4 ESPWA 1425 Copyright (C) 2013 CA. All rights reserved. R00394-D7Y114-SP1 DESC(WRONG COND STATEMENT USED WHEN RESET THROUGH MGRMSG). PRE ( RO57530 RO57764 ) SUP ( RO48789 RO51846 RO52128 RO52192 RO56370 RO56916 RO57234 RO57528 RO58422 RO58436 TR48789 TR51846 TR51949 TR52128 TR52192 TR53881 TR54135 TR56370 TR56417 TR56916 TR57234 TR57240 TR57528 TR58081 TR58422 TR58436 TR59306 )

CA Workload Automation ESP Edition 11.4 49 CA RS 1309 - PTF RO59341 11.4 RO59341 RO59341 M.C.S. ENTRIES = ++PTF (RO59341) APPLICATION SLOT OVERLAYS NOT DETECTED BY CYBESUT1 Note: This fix addresses 4 problems. Problem 1 --------- Prior to this fix the file utility batch program CYBESUT1 did not have the ability to detect application slot overlays. CYBESUT1 can now detect and correct application slot overlays, including those that can potentially cause the subsystem to abend, by marking the affected applications invalid. To report application slot overlays that can potentially crash the subsystem, run batch utility CYBESUT1 with JCL such as the following - //REPORT JOB... //CYBESUT1 EXEC PGM=CYBESUT1, // PARM=('JOBINDEX(CA.ESP.JOBINDEX)', // 'APPLFILE(CA.ESP.APPLFILE)') //STEPLIB DD DISP=SHR,DSN=CA.ESP.CD7YLOAD //SYSPRINT DD SYSOUT=* This job may be submitted while ESP subsystems using the same JOBINDEX and APPLFILE data sets are running. If there are any application slot overlays that may crash the subsystem, a data line such as the following will be present in the SYSPRINT file one - *** Warning *** APPL001.2 (slot 3791) slot 4236 overlaid by APPL006.4, may cause subsystem failure The application that caused the slot overlay will only be displayed if this can be determined. If ANALYZE is specified in the CYBESUT1 PARM above (not necessary), a number of application slot overlays will almost certainly be detected and printed in the SYSPRINT file. They will look something like this - APPL010.1 (slot 246) not in APPLFILE, overlaid by APPL012.2 The application that caused the slot overlay will only be displayed if this can be determined. This kind of overlay is benign as the subsystem is able to detect it. If at least one warning message of a slot overlay that can potentially crash the subsystem appears in the SYSPRINT file, the JCL for a CYBESUT1 batch utility run to repair this condition should look something like the following - //REPAIR JOB... //CYBESUT1 EXEC PGM=CYBESUT1,PARM=('REPAIR', // 'SUBSYSTEM(ESPM)', // 'JOBINDEX(CA.ESP.JOBINDEX)', // 'APPLFILE(CA.ESP.APPLFILE)') //STEPLIB DD DISP=SHR,DSN=CA.ESP.CD7YLOAD //SYSPRINT DD SYSOUT=* *** NOTE *** ------------ The SUBSYSTEM parameter specifies an ESP subsystem running on the same system as utility CYBESUT1. When specified with the REPAIR (or UPDATE) operand, the JOBINDEX and APPLFILE data sets can safely be updated while ESP subsystems using these data sets are active, as CYBESUT1 will serialize with an ENQ on the ESP subsystem RSVLOGIC resource. This will prevent concurrent updates of the JOBINDEX and/or APPLFILE data sets by CYBESUT1 and an ESP subsystem. The above job will mark any application invalid if it has at least one slot overlay that can potentially crash the subsystem. Then any attempt to access that application will result in a "not found" condition. For each application marked invalid, a message such as the following will appear in the SYSPRINT file - APPL001.2 (slot 3791) slot overlay, marked invalid Note that UPDATE can be specified instead of REPAIR in the above CYBESUT1 run, but it is not necessary. If UPDATE is specified, then all applications with slot overlays, including those that are benign, will be marked invalid.