Temperature and humidity mapping of cleanrooms. Presented by Bernie Prendergast 11 th August 2015

Similar documents
Avoid experiments in monitoring important parameters. Measuring instruments and solutions for the pharmaceutical, medical and healthcare industries

SOP:11:VL:023:02:NIBT PAGE 1 of 9

1.0 Executive Summary

Reliable Environmental Monitoring Systems by Design

Energy Saving in Cleanrooms

WIRELESS ENVIRONMENTAL MONITORS

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

the closed-loop control system

ISPE Thailand 3 rd Seminar 2018

the closed-loop control system

Technology for Constructing Environmentally Friendly Data Centers and Fujitsu s Approach

The Basics of HVAC Operation and the Role of Automation. Mr. Jay Zaino GxP Automation, LLC

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

The Efficient Enterprise. All content in this presentation is protected 2008 American Power Conversion Corporation

Systems for Pharmaceutical GMP Environments

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Clean Room Certification Reports Interpreting and Acting on the Good, the Bad and the Ugly!

A course entitled. Particle counting to ISO Parts 1& 2

HPE Energy Efficiency Certification Service

DATA CENTER PRECISION COOLING: The Need For A Higher Level Of Service Expertise

Standard Operating Procedure for the Kaye Validator AVS System

CLEANROOM CERTIFICATION AND ACCEPTANCE PROCEDURES

Data Center Energy and Cost Saving Evaluation

Changes to GMP force cleanroom re-classifications

Designing, Building, and Maintaining a Compliant Sterile Compounding Facility Focusing on incorporating USP <800> Requirements

PARTICLE MEASUREMENT IN CLEAN ROOMS.

ISPE THAILAND AND TIPA 2017

S I T E I N F R A S T R U C T U R E C U R R E N T P R O B L E M S A N D P R O P O S E D S O L U T I O N S

HygroClip DIGITAL Humidity and temperature probe

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

Server room guide helps energy managers reduce server consumption

2016 COOLING THE EDGE SURVEY. Conducted by Vertiv Publication Date: August 30, 2016

Service, Maintenance, Support

DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency

Temperature Test Chambers WT3 WTS3

Data Centers. Powerful Solutions That Put You in Control. Energy Management Solutions. Where your energy dollars are used. 1

Data Center Design and. Management. Steve Knipple. August 1, CTO / VP Engineering & Operations

CHANGES TO THE STANDARD FOR ISO ISO Cleanrooms and Associated Controlled Environments

Are all CFD s created equal? Prepared by: Associate Director: Sam Wicks

EDX DC-3 environmental monitoring solution

DATA CENTER AIR HANDLING COOLING SOLUTIONS

TSI AEROTRAK REMOTE WITH PUMP PARTICLE COUNTERS INSTALLATION CONSIDERATIONS

Avoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms

Bulletin 817 Thermistor Protection Relay

CRITICAL INFRASTRUCTURE ASSESSMENTS

Variable Density, Closed-Loop, Water-Cooled Data Center Solution

ISO INTERNATIONAL STANDARD

Application of Green Technology For Data Centre

The basis for precision

Cleanrooms and associated controlled environments. Part 14: Assessment of suitability for use of equipment by airborne particle concentration

Liebert : The Right Cooling For IT Environments

Thermal management. Thermal management

APRIL 2010 VOL. 13 NO. 4. Modular Cleanrooms for Business Startups and New Product Development

Ease of Use. Data at Your Fingertips LMS PHARMA

ISO/IEC This is a preview - click here to buy the full publication INTERNATIONAL STANDARD. First edition

Remote Monitoring. for Building HVAC Systems. A unique combination of human expertise and technology helps ensure optimum operation.

TITAN S8. Transportable Data Acquisition Device. Product Brochure EN

Recapture Capacity for Existing. and Airflow Optimization

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Temperature/Humidity, Vibration Chambers

Data Center Assessment Helps Keep Critical Equipment Operational. A White Paper from the Experts in Business-Critical Continuity TM

Introducing the Heat Wheel to the Data Center

Customer Replacement Procedure

The City of St. Petersburg (City) initiated

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet

Temperature/Humidity Agree vibration chambers

This document is a preview generated by EVS

MSYS 4480 AC Systems Winter 2015

FCU (FREE COOLING UNIT)

Data Center Optimized Controls

10 COMMON TRAPS IN DESIGNING A CLEANROOM

WHAT YOU NEED TO KNOW ABOUT SCR POWER CONTROLLERS FUNCTIONS, FEATURES, AND EFFICIENCIES

SMART VENTILATION MANAGEMENT: CHANGING THE WAY WE THINK ABOUT VENTILATION

Intelligent / Sustainable Buildings utilizing Under-Floor HVAC Systems Advantages over the Life Cycle of a Commercial Building

ZTE ZXCR Series DX In-Row Air Conditioning Product Description

Validation and Uncertainty Characterization for Energy Simulation

Liebert. icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

18 th National Award for Excellence in Energy Management. July 27, 2017

Replacing a 3.5-inch disk drive

New Techniques for Energy-Efficient Data Center Cooling

Cleanrooms and Standards The Road Ahead

Checklist for building an edge data center

Technical Review: European GMP Annex edition

The Four 4R s. of Data Center Airflow Management. About Upsite Technologies

SMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER

APPROVAL SHEET PROCEDURE INFORMATION SECURITY MANAGEMENT SYSTEM CERTIFICATION. PT. TÜV NORD Indonesia PS - TNI 001 Rev.05

LANL High Performance Computing Facilities Operations. Rick Rivera and Farhad Banisadr. Facility Data Center Management

Automatic tools for fault detection and diagnostic of HVAC systems for hotel and office building

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

ISO INTERNATIONAL STANDARD. Cleanrooms and associated controlled environments Part 5: Operations

Jaap Hogeling Chair CEN TC 371 Program Committee on EPBD (Energy Performance Buildings Directive)

Green Data Centers A Guideline

Is Data Center Free Cooling Feasible in the Middle East? By Noriel Ong, ASEAN Eng., PMP, ATD, PQP

Advanced Virtual Building Software in Finland - Tools in a Real Life Building Services Design Process

Reducing Energy Consumption with

Data Center Infrastructure Management (DCIM) By Jesse Zhuo

APC APPLICATION NOTE #114

Transcription:

Temperature and humidity mapping of cleanrooms Presented by Bernie Prendergast 11 th August 2015

Temperature & Humidity mapping of cleanrooms Why are we discussing this? Where is it required? When should you do it? What testing should you do? What do we do with the data? Slide 2 of 31 PharmOut 2015

Temperature & Humidity mapping of cleanrooms So, why should we consider mapping cleanrooms? Slide 3 of 31 PharmOut 2015

Why should we consider mapping cleanrooms? Historically, mapping of cleanrooms has not been performed beyond a single point temperature or humidity verification during qualification because... Slide 4 of 31 PharmOut 2015

Why should we consider mapping cleanrooms? Historically, mapping of cleanrooms has not been performed beyond a single point temperature or humidity verification during qualification because... Room temperature is rarely a CPP Slide 5 of 31 PharmOut 2015

Why should we consider mapping cleanrooms? Historically, mapping of cleanrooms has not been performed beyond a single point temperature or humidity verification during qualification because... Room temperature is rarely a CPP Room humidity is sometimes a CPP Slide 6 of 31 PharmOut 2015

Why should we consider mapping cleanrooms? Historically, mapping of cleanrooms has not been performed beyond a single point temperature or humidity verification during qualification because... Room temperature is rarely a CPP Room humidity is sometimes a CPP Insofar as CPPs go, these room environmental parameters are probably considered less critical. Slide 7 of 31 PharmOut 2015

Why should we consider mapping cleanrooms? However, if these parameters are CPPs CPPs should be fully qualified/validated, and for HVAC parameters this should include mapping If room temperature and/or humidity is critical to control of product quality, mapping is an indispensable part of demonstrating the validity of the controls Slide 8 of 31 PharmOut 2015

Why should we consider mapping cleanrooms? But what about when they aren t CPPs? GMP is a little vague on requirements: So, temperature may not always be a CPP, but in accordance with 3.12, it is always GMP critical and needs to be controlled! Humidity does not need to be considered GMP critical except where necessary (where it is a CPP) and therefore does not always need to be controlled Slide 9 of 31 PharmOut 2015

Why should we consider mapping cleanrooms? The expectations of what controlled means has evolved over time For most facilities, the expectation now is that HVAC temperature and humidity is controlled through a BMS and that the system is monitored (to verify the control) through a validated EMS/FMS The outputs of the EMS are typically Quality reviewed regularly to confirm that the GMP critical data is maintained within limits Slide 10 of 31 PharmOut 2015

Why should we consider mapping cleanrooms? BUT, EMS data is typically generated from a single point sensor. Slide 11 of 31 PharmOut 2015

Why should we consider mapping cleanrooms? BUT, EMS data is typically generated from a single point sensor. Regulatory inspections are increasingly asking for justification for EMS (or manual) sensor locations Slide 12 of 31 PharmOut 2015

Why should we consider mapping cleanrooms? BUT, EMS data is typically generated from a single point sensor. Regulatory inspections are increasingly asking for justification for EMS (or manual) sensor locations EMS installers are rarely experts in appropriate locating of sensors Slide 13 of 31 PharmOut 2015

Why should we consider mapping cleanrooms? Take home message Room mapping is the most effective way to justify sensor locations, when used in conjunction with a risk based assessment. Slide 14 of 31 PharmOut 2015

Temperature & Humidity mapping of cleanrooms So, where should you perform cleanroom mapping? Slide 15 of 31 PharmOut 2015

Where should you perform cleanroom mapping? Wherever temperature sensitive material is stored in cleanrooms (and the cleanroom is the primary environmental control), e.g. Consumable stores Staging rooms Any other classified area where temperature sensitive material is held for an extended duration before, during or after processing. Slide 16 of 31 PharmOut 2015

Where should you perform cleanroom mapping? Other clean areas where temperature / humidity is a CPP; for e.g. Processing of highly temperature sensitive materials, requiring tight control during manufacture Processing of humidity sensitive materials (many OSD products) Drying rooms / cabinets Pre-conditioning rooms (eg EtO sterilization) Slide 17 of 31 PharmOut 2015

Where should you perform cleanroom mapping? Where temperature is not a CPP, consider other production areas where temperature excursion is undesirable or the impact needs to be assessed Base on risk assessment Consider the implications on product of excessive temperature excursion (e.g. 27 C, 15 C) in processing rooms Intra-room temperature variations of up to 5 C are not improbable where heating/cooling sources are present Slide 18 of 31 PharmOut 2015

Temperature & Humidity mapping of cleanrooms So, when should you perform cleanroom mapping? Slide 19 of 31 PharmOut 2015

When should you perform mapping of cleanrooms? Ultimately, and as always, this is risk based. But consider Slide 20 of 31 PharmOut 2015

When should you perform mapping of cleanrooms? Ultimately, and as always, this is risk based. But consider Prior to facility start-up during initial cleanroom qualification Slide 21 of 31 PharmOut 2015

When should you perform mapping of cleanrooms? Ultimately, and as always, this is risk based. But consider Prior to facility start-up during initial cleanroom qualification If parameter is a CPP: 1 to 3 years (consider risk of sensitivity of product(s), how far outside ambient, system capability, etc.) Slide 22 of 31 PharmOut 2015

When should you perform mapping of cleanrooms? Ultimately, and as always, this is risk based. But consider Prior to facility start-up during initial cleanroom qualification If parameter is a CPP: 1 to 3 years (consider risk of sensitivity of product(s), how far outside ambient, system capability, etc.) If parameter is not a CPP: 3 to 5 years Slide 23 of 31 PharmOut 2015

When should you perform mapping of cleanrooms? Ultimately, and as always, this is risk based. But consider Prior to facility start-up during initial cleanroom qualification If parameter is a CPP: 1 to 3 years (consider risk of sensitivity of product(s), how far outside ambient, system capability, etc.) If parameter is not a CPP: 3 to 5 years Whenever significant modifications to the system or the room have been made Slide 24 of 31 PharmOut 2015

When should you perform mapping of cleanrooms? Ultimately, and as always, this is risk based. But consider Prior to facility start-up during initial cleanroom qualification If parameter is a CPP: 1 to 3 years (consider risk of sensitivity of product(s), how far outside ambient, system capability, etc.) If parameter is not a CPP: 3 to 5 years Whenever significant modifications to the system or the room have been made Whenever analysis shows unexplained variability outside normal operating limits Slide 25 of 31 PharmOut 2015

When should you perform mapping of cleanrooms? Ultimately, and as always, this is risk based. But consider Prior to facility start-up during initial cleanroom qualification If parameter is a CPP: 1 to 3 years (consider risk of sensitivity of product(s), how far outside ambient, system capability, etc.) If parameter is not a CPP: 3 to 5 years Whenever significant modifications to the system or the room have been made Whenever analysis shows unexplained variability outside normal operating limits Seasonal variation Slide 26 of 31 PharmOut 2015

Temperature & Humidity mapping of cleanrooms So, what testing is required for effective mapping? Slide 27 of 31 PharmOut 2015

What testing is required for effective mapping? The room should be gridded in 3D. Typical rooms will require between 15-25 sensors. Product critical locations should be assessed Slide 28 of 31 PharmOut 2015

Typical mapping arrangement From WHO Technical Supplement to TRS 961, 2011 Slide 29 of 31 PharmOut 2015

What testing is required for effective mapping? The room should be gridded in 3D. Typical rooms will require between 15-25 sensors. Product critical locations should be assessed Sensor numbers and locations should be carefully selected and justified in protocols (references to follow). Methodology should be documented in procedures Slide 30 of 31 PharmOut 2015

What testing is required for effective mapping? The room should be gridded in 3D. Typical rooms will require between 15-25 sensors. Product critical locations should be assessed Sensor numbers and locations should be carefully selected and justified in protocols (references to follow). Methodology should be documented in procedures Mapping should be typically be hours. Lower times may be justifiable in low risk areas. Number of data points TBD Slide 31 of 31 PharmOut 2015

What testing is required for effective mapping? The room should be gridded in 3D. Typical rooms will require between 15-25 sensors. Product critical locations should be assessed Sensor numbers and locations should be carefully selected and justified in protocols (references to follow). Methodology should be documented in procedures Mapping should be typically be hours. Lower times may be justifiable in low risk areas. Number of data points TBD Humidity requirements should basically follow temperature, although it may be justifiable to use fewer sensors, especially if used in conjunction with temperature mapping. Slide 32 of 31 PharmOut 2015

What testing is required for effective mapping? Probe locations should consider how the map may be affected by items such as: The location of the process / product The location of air supply registers (can be hot or cold spots) Heat sources (eg autoclaves, bag sealers, other large equipment) Cold sources (cooling systems) Areas of high / low airflow Areas of high traffic, etc Slide 33 of 31 PharmOut 2015

What testing is required for effective mapping? Temperature mapping of storage areas WHO Supplement to Technical Report Series 961, Annex 9, 2011 ISPE Concept Paper on Temperature Controlled Storage Chambers, 2012 (currently ISPE are drafting a GPG based on this paper) Qualification of temperature controlled storage areas WHO Supplement to Technical Report Series 961, Annex 9, 2011 PIC/S PE011-1 Guide to Good Distribution Practice (requires mapping requirements to be determined by risk assessment) Slide 34 of 31 PharmOut 2015

Temperature & Humidity mapping of cleanrooms So, what do we do with the data? Slide 35 of 31 PharmOut 2015

What do we do with the data? Analyse the data: Calculate mean / high / low results in each location at each time point Document the internal temperature / RH variations observed within the room Slide 36 of 31 PharmOut 2015

What do we do with the data? Assess the data: Use the data analysis to assess the overall temperature / RH stability of the mapped space in relation to the stated acceptance criteria Assess the overall thermal stability of the space during the study period with specific reference to the high and low temperatures experienced Assess consistent and inconsistent temperature / RH variations, and fluctuations, within the space in terms of their potential impact on processes Slide 37 of 31 PharmOut 2015

What do we do with the data? Make recommendations: Based on the observed temperature / RH fluctuations of mapped locations within the space, make recommendations about suitability of areas for active processing Based on the observed temperature / RH fluctuations of mapped locations within the space, provide recommendations or justification for the on the location of the temperature/rh sensor(s) used for routine temperature monitoring and the control sensors used to activate the heating and cooling systems. Slide 38 of 31 PharmOut 2015

Thank you for your time. Questions? Bernie Prendergast Senior Consultant Bernie.Prendergast@pharmout.net www.pharmout.net Slide 39 of 31 PharmOut 2015