I. The digital image MEDICAL IMAGING METHODS. Optical illusions - intensity (color density) Optical illusions space. Optical illusions size, direction

Similar documents
Physical bases of X-ray diagnostics

BME I5000: Biomedical Imaging

Radiology. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

Image Acquisition Systems

Diagnostic imaging techniques. Krasznai Zoltán. University of Debrecen Medical and Health Science Centre Department of Biophysics and Cell Biology

Introduction to Biomedical Imaging

Tomographic Reconstruction

Some reference material

MEDICAL IMAGING 2nd Part Computed Tomography

Corso di laurea in Fisica A.A Fisica Medica 4 TC

Ch. 4 Physical Principles of CT

Cardiac Dual Energy CT: Technique

Physics 210 Medical Physics Midterm Exam Fall 2012 October 12, 2012

MEDICAL IMAGING 2nd Part Computed Tomography

Digital Image Processing

CT Basics Principles of Spiral CT Dose. Always Thinking Ahead.

Computer-Tomography I: Principles, History, Technology

RADIOLOGY AND DIAGNOSTIC IMAGING

Computer-Tomography II: Image reconstruction and applications

Computed tomography - outline

Computational Medical Imaging Analysis

MEDICAL IMAGE ANALYSIS

8/7/2017. Disclosures. MECT Systems Overview and Quantitative Opportunities. Overview. Computed Tomography (CT) CT Numbers. Polyenergetic Acquisition

First CT Scanner. How it Works. Contemporary CT. Before and After CT. Computer Tomography: How It Works. Medical Imaging and Pattern Recognition

Moscow-Bavarian Joint Advanced Student School 2006 / Medical Imaging Principles of Computerized Tomographic Imaging and Cone-Beam Reconstruction

Midterm Review. Yao Wang Polytechnic University, Brooklyn, NY 11201

Computed Tomography January 2002 KTH A.K.

Spiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA

Enhanced material contrast by dual-energy microct imaging

Effect of Scattering on the Image. Reducing Compton Scatter with a Grid

Joint CI-JAI advanced accelerator lecture series Imaging and detectors for medical physics Lecture 1: Medical imaging

Shadow casting. What is the problem? Cone Beam Computed Tomography THE OBJECTIVES OF DIAGNOSTIC IMAGING IDEAL DIAGNOSTIC IMAGING STUDY LIMITATIONS

CT vs. VolumeScope: image quality and dose comparison

Computed Tomography. Principles, Design, Artifacts, and Recent Advances. Jiang Hsieh THIRD EDITION. SPIE PRESS Bellingham, Washington USA

A closer look at CT scanning

Lecture 4 Image Enhancement in Spatial Domain

Medical Images Analysis and Processing

Digital Image Acquisition

DUAL energy X-ray radiography [1] can be used to separate

Cherenkov Radiation. Doctoral Thesis. Rok Dolenec. Supervisor: Prof. Dr. Samo Korpar

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

Computed Tomography. Principles of Medical Imaging. Contents. Prof. Dr. Philippe Cattin. MIAC, University of Basel. Sep 26th/Oct 3rd, 2016

Biomedical Imaging. Computed Tomography. Patrícia Figueiredo IST

CoE4TN4 Image Processing. Chapter 5 Image Restoration and Reconstruction

Computational Medical Imaging Analysis

Introduction to Digital Image Processing

Phase-Contrast Imaging and Tomography at 60 kev using a Conventional X-ray Tube

DUE to beam polychromacity in CT and the energy dependence

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

UNIVERSITY OF SOUTHAMPTON

EEM 463 Introduction to Image Processing. Week 3: Intensity Transformations

Babu Madhav Institute of Information Technology Years Integrated M.Sc.(IT)(Semester - 7)

Chapter 3: Intensity Transformations and Spatial Filtering

COMPARATIVE STUDIES OF DIFFERENT SYSTEM MODELS FOR ITERATIVE CT IMAGE RECONSTRUCTION

Medical Image Processing: Image Reconstruction and 3D Renderings

CLASS HOURS: 4 CREDIT HOURS: 4 LABORATORY HOURS: 0

Metal Artifact Reduction CT Techniques. Tobias Dietrich University Hospital Balgrist University of Zurich Switzerland

Medical Imaging BMEN Spring 2016

Basics of treatment planning II

The OpenGATE Collaboration

Contrast Enhancement with Dual Energy CT for the Assessment of Atherosclerosis

Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.

X-ray tomography. X-ray tomography. Applications in Science. X-Rays. Notes. Notes. Notes. Notes

FINDING THE TRUE EDGE IN CTA

An Introduction to Images

IMAGING. Images are stored by capturing the binary data using some electronic devices (SENSORS)

MEDICAL EQUIPMENT: COMPUTED TOMOGRAPHY. Prof. Yasser Mostafa Kadah

Digital Scatter Removal in Mammography to enable Patient Dose Reduction

Philips SPECT/CT Systems

Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography

Principles of Computerized Tomographic Imaging

TEP Hounsfield units. Related topics Attenuation coefficient, Hounsfield units

EE795: Computer Vision and Intelligent Systems

Joint ICTP-TWAS Workshop on Portable X-ray Analytical Instruments for Cultural Heritage. 29 April - 3 May, 2013

Reconstruction in CT and relation to other imaging modalities

Electron Dose Kernels (EDK) for Secondary Particle Transport in Deterministic Simulations

ELEG404/604: Digital Imaging & Photography

Low-Dose Dual-Energy CT for PET Attenuation Correction with Statistical Sinogram Restoration

Monte Carlo simulations. Lesson FYSKJM4710 Eirik Malinen

Monte Carlo simulations

Proton dose calculation algorithms and configuration data

DUAL energy CT (DECT) is a modality where one and. Empirical Dual Energy Calibration (EDEC) for Cone-Beam Computed Tomography

Fundamentals of CT imaging

CT: Physics Principles & Equipment Design

CT Systems and their standards

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D.

The MAGIC-5 CAD for nodule detection in low dose and thin slice lung CT. Piergiorgio Cerello - INFN

Medical Imaging Projects

ML reconstruction for CT

Morphological Image Processing

Introduction to Emission Tomography

Index. aliasing artifacts and noise in CT images, 200 measurement of projection data, nondiffracting

PROVIDE A UNIFORM DOSE IN THE SMALL ANIMAL.

Vivekananda. Collegee of Engineering & Technology. Question and Answers on 10CS762 /10IS762 UNIT- 5 : IMAGE ENHANCEMENT.

Lecture 6: Medical imaging and image-guided interventions

Construction of Voxel-type Phantom Based on Computed Tomographic Data of RANDO Phantom for the Monte Carlo Simulations

DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE

Evaluation of Spectrum Mismatching using Spectrum Binning Approach for Statistical Polychromatic Reconstruction in CT

Combining Analytical and Monte Carlo Modelling for Industrial Radiology

Méthodes d imagerie pour les écoulements et le CND

Transcription:

I. The digital image Seeing is believing!? Vision is not only the detection of image information, but complex processing occurs as well MEDICAL IMAGING METHODS Optical illusions size, direction Miklós Kellermayer Optical illusions - intensity (color density) Optical illusions space

Optical illusions motion Optikai csalódások mozgás Image: information that is visible or not?

Light microscopic image Hepatic lobule Scanning electron microscopic images Atomic force microscopic images CT MRI Red blood cell bacteriorhodopsin DNA

Digital Image Analysis 1. The digital image a. Generation b. Characteristics 2. Image enhancement techniques a. Contrast manipulation b. Convolution c. Rank operations 3. Geometric transformations 4. Fourier transformation 5. Thresholding and segmentation The digital image Digital image: information displayed at different discrete spatial points in the form of color. 2 or 3 dimensional array or matrix of picture elements. Characteristics of the digital image: 1. Picture element: pixel (pix=picture; element) 2. Information associated with the pixel: a. XY location: coordinates related to spatial resolution b. Color depth: intensities related to color (or grayscale)resolution 3. Spatial resolution: Number of resolved pixels in the X and Y directions. 4. Grayscale/color depth: Number of resolved colors/grayscale intensities (bit) (BUT: color is not necessarily real; e.g. AFM, CT, MRI) y j x i P i,j 6. 3D image analysis THE COLOR HISTOGRAM (intensity histogram, grayscale histogram) Resolved intensities may be displayed as a function Image enhancement techniques I. Contrast manipulation A. Contrast transfer function: assigns color to pixel densities (expressed in numerical values) Histogram: relative frequency of colors or grayscale intensities in the image n 0 255

Contrast manipulation B. Histogram equalization Goal: best use of the available color/grayscale range Image enhancement techniques II. Convolution Special transformation between two functions (the image and the kernel) Kernel operations The cumulative histogram of the image is used as its contrast transfer function smoothing kernel 1 1 1 1 1 1 1 1 1 * P x,y = + m W i,j P x +i,y+ j i, j = m +m W i, j i, j = m smoothing convolution P=original pixel intensity x,y=coordinates of the pixel on which operation is being executed P*=modified pixel intensity ±m=size of kernel (distance from x,y coordinate) W=weight of kernel at a given i,j coordinate i,j=coordinates within kernel (integers between -m and +m) Various kernels Gauss Image enhancement techniques II. Convolution Original image Image enhancement techniques III. Rank operations Principle: the pixel is exchanged for another from its ranked neighborhood (e.g., min, max, median) Noise removal using median filtering: Sharpening Gauss (smoothing) Edge detection 3x3 median filter

Geometric transformations Basic problem: 2D image from 3D object IV. Fourier transformation Fourier principle: any function may be generated as the sum of a sine function and its harmonics. Fourier transform -> spectral density: displays the contribution of a given frequency. Original image FFT Inverse FFT Masked FFT Thresholding, segmentation Principle: The image is partitioned according to certain parameters. Binary operations I. Boolean operations Execution: 1. Select a certain grayscale range of the image 2. The selected pixels form the "foreground 3. The rest of the pixels form the "background" A image B image A OR B A union B Binary image A AND B A intersection B A NOR B ( A union B ) - ( A intersection B ) NOT A Complement of A

Binary operations II. Erosion, dilatation, Opening, Closing Moving pixels from the foreground to the background and vice versa Binary operations III. Skeletonization, Outlining Erosion and dilatation with certain rules Erosion -> Original image Binary image Skeletonized image Outlined image Dilatation -> Boolean operation -> Result: separation of touching objects 3D image processing voxel: volume element pixel: picture element Image Spatial projection ( volume rendering ) II. X-ray imaging Image format of medical diagnostics: DICOM (Digital Imaging and Communications in Medicine)

X-rays are electromagnetic waves Generation of X-ray I anode anode (anticathode) X- rays U anode cathode ray cathode Wavelength 10-0.01 nm. Frequency 30x10 15-30x10 18 Hz. Energy 120 ev - 120 kev. I heating U heating Rotating anode X-ray tube Duane-Hunt formula: λ min = hc e 1 U anode h=planck s constant c=speed of light e=elementary charge Mechanisms of X-ray generation Spectral features of X-ray Bremsstrahlung Characteristic radiation Bremsstrahlung Breaking radiation Deceleration radiation Characteristic radiation X-ray fluorescence Continuous spectrum Linear spectrum

X-ray absorption X-ray photoeffect Incident intensity J 0 x absorbent Outgoing intensity J Exponential attenuation principle J J 0 J = J 0 e μx x incoming X-ray photon (hf) Binding energy (A) 100 kev photon 66 kev photoelectron may participate in X-ray generation Main effect in diagostic X-ray! Photoeffect attenuation coefficient: τ = τ m ρ μ = μ m ρ μ=attenuation coefficient μ m=mass attenuation coefficient (cm 2 /g) ρ=density (g/cm 3 ) Photoeffect attenuation depends strongly on atomic number Compton scatter wavelength (pm) τ m = const Z 3 ε 3 = C λ3 Z 3 valence electrons Compton electron For multi-component system: effective atomic number (Z eff) Z eff = 3 3 w i Z i n i=1 ε=photon energy Z=atomic number w=mole fraction n=number of components Arthur Holly Compton (1892-1962) Material Zeff Air 7.3 hf = A + hf scatt + E kin incoming photon photon energy (kev) Water 7.7 Soft tissue 7.4 Bone 13.8 scattered photon

Pair production attenuation mechanisms incoming photon pair production Dependence on photon energy and material Energy balance: Lead Water β - (electron) hf = 2m e c 2 + 2E kin β + (positron) m e=mass of electron c=speed of light E photon (MeV) E photon (MeV) radiation Pair production relevant in highenergy X-ray photons, γ- radiation. μ = τ + σ +κ μ m=mass attenuation coefficient τ m=photoeffect mass attenuation coefficient σ m=compton effect mass attenuation coefficient κ m=pair production mass attenuation coefficient Summary of attenuation mechanisms Imaging with X-ray Mechanism Variation of μ m with E Variation of μ m with Z Energy range in tissue Rayleigh ~ 1 / E ~Z2 1-30 kev photoelectric ~1 / E 3 ~Z 3 10-100 kev Compton falls gradually with E independent ~Z 0.5-5 MeV pair production rises slowly with E ~ Z 2 > 5 MeV Main contrast mechanism in diagnostic X-ray: photoelectric effect (~Z 3 ) Wilhelm Konrad Röntgen (1845-1923) Hand mit Ringen (Hand with Ring): print of Wilhelm Röntgen's first "medical" X-ray, of his wife's hand, taken on 22 December 1895 and presented to Professor Ludwig Zehnder of the Physik Institut, University of Freiburg, on 1 January 1896. The dark oval on the third finger is a shadow produced by her ring.

Principle of X-ray imaging The x-ray image X-ray source X-rays J = J 0 e (μ 1x 1 +μ 2 x 2 +μ 3 x 3 +...) lg J 0 J = ( μ x + μ x + μ x +...) lge 1 1 2 2 3 3 Attenuation (Human body) μ and x are attenuation coefficient and thickness of elementary volume unit lying in the direction of X-ray beam. Detector (film, screen, sensor) X-ray image is summation image. X-ray image, radiographic image, roentgenogram. Contrast arises due to relative attenuation. Radiographic contrast Improving the X-ray image The image intensifier Bowels (positive contrast) Air (negative contrast) C-arm Large intestine (double contrast) Small intestine (double contrast) Possibility of image digitization.

Digital Subtraction Angiography (DSA) Improving X-ray imaging II. Spatial resolution Bi-directional X-ray imaging Image 1 Image 2 DSA image native contrast contrast-native Bi-directional cranial X-ray of an individual who tried to commit suicide with a crossbow. Improving X-ray imaging: the CAT scanner History Prototype CT scanner Röntgen, Hounsfield and Cormack 1967: first CAT scan 1972: prototype 1974: first clinical CAT image (head) 1976: whole body CAT scan 1979: Nobe-prize 1990: spiral CAT scanner 1992: multislice CAT scanner 2006: 64 slice (and more ) multiple and hybrid modes: SPECT-CT, PET-CT, Dual-source CT Godfrey Hounsfield Siretom head scanner (1974) Allan Cormack 128x128 pixel image (1975) The very first ct scanner prototype. Invented by Houndsfield at EMI.

CT Foundations I CT Foundations II source detector μ x : linear attenuation coefficient Scanning I Scanning II III-IV. generation: single moving source, wide fan-beam, multiple detectors or detector ring I. generation Single moving source Single moving detector II. generation Single moving source Narrow fan-beam Multiple moving detectors closed gantry open gantry

Spiral (helical) CAT scaning Source-detector pair rotates constantly CT scanning (CAT) Conventional CT slice Multi-detector CT (MDCT) Spiral CT slice Multi-slice CT (MSCT) Tomographic digital imaging method that uses X- rays Principle: displaying differences in X-ray absorbance by the different points of the tomographic slice Conventional (outdated) technique: one slice 2-4 sec, entire examination: 5-15 perc Spiral CT technique: one slice 1-1.5 sec, entire examination: 30-60 sec (+ preparation) Multidetector spiral CT (4-64 detector array): one slice 0.4-1 sec, entire examination: 5-15 sec CT scanner operation CT Image Reconstruction Detectors Rotation 1. Algebraic reconstruction techniques 2. Direct Fourier reconstruction 3. Filtered Back Projection Tube X-ray beams CT image: 4000 detectors 1000 projections 512x512 matrix 16 bit color depth

CT Image: Density matrix Contrast manipulation of CT Image Windowing N CT =1000 μ μ w μ w μ: attenuation coefficient of voxel μ w : attenuation coefficient of water Density ( CT number ): Hounsfield units Brain window Manipulation of CT contrast Windowing Soft tissue window Lung window Bone window Limitations of CAT scanning Ionizing radiation Irradiation dose up to 50-100 times that of conventional X-ray imaging! direct exposure to radiation + scattered radiation (its intensity is 1-2 orders of magnitude smaller)

Very thin (1-2 mm) slices, very high contrast resolution. Important in case of large contast differences (e.g., bone - lung). Image processing: by using dedicated algorithms HRCT (High Resolution CT) Dual Source CT Simultaneous use of two different X-ray sources and detectors. The two tubes are positioned perpendicular to each other, the detectors work in synchrony. If the sources are operated at identical accelerating voltage, 90 rotation is sufficient to generate a tomographic slice. The sources may also be operated at different accelerating voltages ( dual-energy mode, 80 and 140 kv). 180 rotation is required to generate an image slice. In dual-energy mode two image slices with different information content are generated, due to the different tissue absorbance of the X-ray photons with different energies CT contrast agents Water soluble, iodine-containing macromolecule causing enhanced absorbance (hence color density) at the sites of accumulation Ionic contrast agent outdated (abandoned since the 1990s) Non-ionic (monomeric or dimeric, low osmolality) Filtration through the kidney (nephrotropic). Its filtration begins immediately. Applications: every X-ray based imaging method Imaging blood vessels - CT angiography Native CT: limited applications. Only in case of severely calcified vessel walls With intravenous contrast agents: conventional technique - vessels with d > 1 cm (aorta) Spiral CT-angiography: Single-detector array spiral CT - aorta branches (d > 2-3 mm) Multidetector array spiral CT - peripheral vessels (d > 1 mm)

Renal artery aneurysm CTA 8 detector-array spiral CT Coronary CT-angiography (CTCA) 64-slice MDCT Hybrid technologies: NanoSPECT/CT NanoSPECT/CT Tl-201 Dual-channel SPECT CT: 36 μm voxel size Real-time CT reconstruction (GPU) 99m Tc-DTPA: diethylenetriaminepentaacetic (BBB) - blue/red) 99m Tc-HMPAO: hexamethylpropyleneamine oxime (perfusion) - blue/red) 201 Tl-DDC: diethylthiocarbamate (perfusion) - green Boa constrictor Osteomyelitis, 99m Tc-MDP (methylenediphosphonate)