Troubleshooting the Cisco UCS Compute Deployment BRKCOM Cisco and/or its affiliates. All rights reserved.

Similar documents
UCS Networking Deep Dive. Neehal Dass - Customer Support Engineer

UCS Engineering Details for the SAN Administrator

UCS Networking Deep Dive

UCS Networking 201 Deep Dive

UCS Networking Deep Dive

UCS Firmware Management Architecture

Cisco Exam Questions & Answers

"Charting the Course... Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary

UCS Networking Deep Dive

Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects?

UCS Fabric Fundamentals

UCS Fabric Fundamentals

Disjoint Layer2 Uplinks (DLU)

FCoE Configuration Between VIC Adapter on UCS Rack Server and Nexus 5500 Switch

Using Advanced Features on Cisco UCS Dan Hanson, Technical Marketing Manager, Data Center Group

UCS-ABC. Cisco Unified Computing System Accelerated Boot Camp. Length: 5 Days. Format: Lecture/Lab. Course Version: 5.0. Product Version: 2.

UCS Management Deep Dive

Q&As. Troubleshooting Cisco Data Center Infrastructure. Pass Cisco Exam with 100% Guarantee

UCS Management Architecture Deep Dive

UCS Technical Deep Dive: Getting to the Heart of the Matter

UCS Direct Attached Storage and FC Zoning Configuration Example


Cisco Actualtests Questions & Answers

Configuring Cisco UCS Server Pools and Policies

Q&As. Troubleshooting Cisco Data Center Unified Computing. Pass Cisco Exam with 100% Guarantee

Implementing Cisco Data Center Unified Computing (DCUCI)

CISCO EXAM QUESTIONS & ANSWERS

Configuring Cisco UCS Server Pools and Policies

CISCO EXAM QUESTIONS & ANSWERS

Next Generation Computing Architectures for Cloud Scale Applications

LAN Ports and Port Channels

UCS IPv6 Management Configuration Example

Vendor: Cisco. Exam Code: Exam Name: DCID Designing Cisco Data Center Infrastructure. Version: Demo

Design and Implementations of FCoE for the DataCenter. Mike Frase, Cisco Systems

UCS deployment guide for Nimble Storage

Introducing Cisco UCS Central 2.0

Implementing Cisco Data Center Unified Computing (DCUCI)

Overview. About the Cisco UCS S3260 System

Cisco Questions & Answers

Actual4Test. Actual4test - actual test exam dumps-pass for IT exams

Nexus 5000 NPIV FCoE with FCoE NPV Attached UCS Configuration Example

Overview. Cisco UCS Manager User Documentation

Questions & Answers

Overview of Cisco Unified Computing System

UCS Fundamentals Aaron Kerr, Consulting Systems Engineer

UCS Supported Storage Architectures and Best Practices with Storage

UCS SAN Deployment Models and Best Practices

Cisco Nexus B22 Blade Fabric Extender for IBM

UCS Management Deep Dive

Direct Attached Storage

CCIE Data Center Written Exam ( ) version 1.0

Real4Test. Real IT Certification Exam Study materials/braindumps

Course Description. Boot Camp Date and Hours: The class starts on Saturday 2 nd of April, 2016 Saturdays Only 8:00 AM 4:00 PM Central Standard Time

UCS Fundamentals. Conor Murphy Partner Systems Engineer. #clmel BRKCOM-1001

UCS Networking Deep Dive

Cisco CCIE Data Center Written (Beta) Download Full Version :

Configuring FCoE NPV. Information About FCoE NPV. This chapter contains the following sections:

Virtualized Access Layer. Petr Grygárek

Cisco UCS Local Zoning

Introducing Cisco UCS Central 1.4

Cisco. Exam Questions DCUCI Implementing Cisco Data Center Unified Computing (DCUCI)

Fabric Failover Scenarios in the Cisco Unified Computing System

CCIE Data Center Lab Exam Version 1.0

Overview. Overview. Cisco UCS 6324 Fabric Interconnect with Cisco UCS B-Series Servers and C-Series Servers, which is. Overview 1

Introducing Cisco UCS Central 1.3

Configuring VM-FEX. Information About VM-FEX. VM-FEX Overview. VM-FEX Components. This chapter contains the following sections:

Configuring Server Boot

UCS Fundamentals. Conor Murphy Partner Systems Engineer. #clmel BRKCOM-1001

Introduction to Cisco UCS Central

UCS iscsi Boot Configuration Example

Cisco Introducing Cisco Data Center Technologies - DCICT. Download Full Version :

vsphere 6.0 with HP ProLiant Gen9 Servers, OneView, 3PAR, Cisco Nexus 5600 and Brocade 6510 Deployment Guide

Cisco Exam Implementing Cisco Data Center Unified Computing Version: 9.0 [ Total Questions: 173 ]

Cisco UCS Manager Network Management Guide, Release 3.2

Configuring Network-Related Policies

Actual4Test. Actual4test - actual test exam dumps-pass for IT exams

Configuring Server Boot

Cisco Exam Questions & Answers

Nimble Storage SmartStack Getting Started Guide Cisco UCS and VMware ESXi5

Designing and Deploying a Cisco Unified Computing System SAN Using Cisco MDS 9000 Family Switches

Configuring Virtual Port Channels

Fibre Channel Zoning

Cisco UCS Manager Storage Management Guide, Release 3.1

Cisco UCS Network Performance Optimisation and Best Practices for VMware

Troubleshooting Cisco Data Center Unified Fabric

Cisco UCS Accelerated Accreditation Training

CCIE Data Center Storage Networking. Fibre Channel Switching Configuration. Nexus 5500UP FC Initialization Allocate interfaces as type FC

Cisco UCS Director Tech Module Cisco UCS Manager (UCSM)

C-Series Jason Shaw, UCS Technical Marketing Steve McQuerry, CCIE # 6108, UCS Technical Marketing

Number: Passing Score: 800 Time Limit: 120 min File Version: 1.0. Cisco

Equipment Policies. Chassis/FEX Discovery Policy

UCS C-Series Server: Bare metal, Storage Appliance, Host-OS Hardware and Software Interoperability Matrix

Cisco Nexus B22HP. Design and Deployment Guide. September, For further information, questions and comments please contact

UCS Performance Troubleshooting

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024 and 8024F. Dell Networking Solutions Engineering March 2012

Microsoft Network Load Balancing on UCS B Series Servers Deployment Configuration Example

Verified Scalability for Cisco Nexus 5500 Series NX-OS Release 7.0(3)N1(1)

Cisco Cisco Data Center Associate Level Accelerated - v1.0 (DCAA)

Traffic Monitoring. Traffic Monitoring

Cisco.Actualtests v by.Dragan.81q

Transcription:

Troubleshooting the Cisco UCS Compute Deployment 2

Agenda Troubleshooting Cisco UCS Overview Physical Setup Software Setup Configuration Path Tracing Maintenance Key Takeaways Q & A 3

Overview

UCS Building Blocks UCS Manager Embedded manages entire system UCS Fabric Interconnect Nexus Switch UCS Fabric Extender Remote line card UCS Blade Server Chassis Flexible bay configurations UCS Blade Server Industry-standard architecture UCS Virtual Adapters Choice of multiple adapters

UCS Manager 2.0 Release New and Updated Features Hardware UCS 6248/96UP Fabric Interconnect UCS 2208XP IOM UCS 2204XP IOM UCS 1280 VIC UCS 1240 VIC (mlom) Features Unified Ports 80 Gb Host connectivity Fabric port-channelling L2 disjoint upstream in EHM VM-FEX for Red Hat KVM iscsi Boot 6

UCS Manager 2.1 Release New and Updated Features Storage Hardware Operations FCoE iscsi NFS CIFS PCIe Flash C-Series Single Wire Firmware Auto Install Fault Suppression UCS FI UCS FI Storage UCS Central (MoM) Multi-Hop FCoE Zoning Configuration Unified Appliance Ports Improved firmware compatibility Networking VM-FEX for Windows UCS servers VLAN Grouping IGMP Configuration Increased logical ports 7

Physical Setup

UCS Fabric Interconnect 6100, 6200 Hardware Standalone or Clustered Primary / Subordinate Data Management Engine (DME) Virtual IP Management Network IP #A IP #B DB DB FI-A# FI-B# Cluster links 9

IO Module HIF to NIF Pinning (2104XP) HIF NIF Server slots pinned to uplink slot 1 slot 2 slot 3 slot 4 slot 5 slot 6 slot 7 slot 8 F E X 1 link Fabric Interconnect Uplink: slots 1,2,3,4,5,6,7,8 slot 1 slot 2 slot 3 slot 4 slot 5 slot 6 slot 7 slot 8 F E X 2 links NIF Fabric Interconnect Uplink 1: slots 1,3,5,7 Uplink 2: slots 2,4,6,8 slot 1 slot 2 slot 3 slot 4 slot 5 slot 6 slot 7 slot 8 F E X 4 links NIF Fabric Interconnect Uplink 1: slots 1,5 Uplink 2: slots 2,6 Uplink 3: slots 3,7 Uplink 4: slots 4,8

IO Module HIF to NIF Pinning (2208XP) Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 1-4 5-8 9-12 13-16 17-20 21-24 25-28 29-32 FEX Fabric Interconnect

IO Module HIF to NIF Pinning (2208XP) Slot 1 1-4 Slot 2 5-8 Slot 3 9-12 Slot 4 13-16 Slot 5 17-20 Slot 6 21-24 Slot 7 Slot 8 25-28 29-32 FEX Fabric Interconnect

IO Module HIF to NIF Pinning (2208XP) Slot 1 1-4 Slot 2 5-8 Slot 3 9-12 Slot 4 13-16 Slot 5 17-20 Slot 6 21-24 Slot 7 Slot 8 25-28 29-32 FEX Fabric Interconnect

IO Module HIF to NIF Pinning (2208XP) Slot 1 1-4 Slot 2 5-8 Slot 3 9-12 Slot 4 13-16 Slot 5 17-20 Slot 6 21-24 Slot 7 Slot 8 25-28 29-32 FEX Fabric Interconnect

IO Module and Failover Lose IOM link 1 1 2 3 4 FI 4 links active IOM 1 Blade1 Blade2 Blade3 Blade4 Blade5 Blade6 Blade7 Blade8 Lose connectivity on mezzanine port mapped to IOM 1 for blades 1 and 5 Blades Note: Which If you Only re-acknowledge of 2,3,4,6,7,8 1 and the a 25 links will will still is to the use chassis, of continue have required, the we will remaining connectivity fall to not back use a 3 chassis all to out a 32 links the topology, mezzanine discover random blades policy decision. 1,3,5,7 port change connected will use one to uplink, IOM and 2 blades 2,4,6,8 will use a different uplink

Port-Channel Pinning No slot based pinning No invalid link count for NIF ports VIC1280 adaptor with DCE links in Port-Channel IOM Pinned to Po Gen-1 adaptor with single 10G link

Chassis Discovery Policy Discovery policy only defines the minimum number of links necessary before a chassis can be discovered and NOT how many links will be utilised

Software Setup

Upgrades

Upgrade Considerations Pre-Checks and Avoiding Issues Release Notes will cover pre-requisites and concerns in the upgrade process Schedule an outage window FI and IOM will reboot during upgrade Make sure network and storage fabric are redundant Highly recommended to backup UCSM configuration Upgrade process is not quick so be patient Follow the upgrade procedure for each version 20

Upgrade Process Order of Operations Backup UCS Config (Full & All Config) Download firmware Update components (adapters, CIMC, IOMs) Activate components in order of: Adapter cards Set Startup Only CIMC UCSM IOM Set Startup Only Fabric Interconnect BIOS/Storage Controller/etc (through firmware package) 21

Upgrade Process UCS 2.1 New Features UCS 2.1 Firmware Auto Install Reduces complexity Better troubleshooting Better compatibility Infrastructure and Blade/Racks 22

Fabric Interconnect Modes

FI Ethernet Modes: End Host Spanning Tree 6x00 A Fabric A VNIC 0 VLAN 10 L2 Switching LAN veth 3 veth 1 VNIC 0 MAC Learning MAC Learning No Spanning Tree Protocol Maintains MAC table for Servers only Allows Multiple Active Uplinks per VLAN Prevents Loops by preventing Uplink-to-Uplink switching Server 2 Server 1

End Host Mode Unicast Forwarding Uplink Ports 6x00 LAN VLAN 10 Deja-Vu RPF veth 1 veth 3 VNIC 0 VNIC 0 Server 2 Server 1 Server 2 Server to server traffic on the same VLAN is locally switched Each server link is pinned to an uplink port / port-channel Network to server unicast traffic is forwarded to server only if it arrives on pinned uplink port. This is termed as the Reverse Path Forwarding (RPF) check Packet with source MAC belonging to a server received on an uplink port is dropped (Deja-Vu Check) Unknown unicast traffic is dropped

EHM Broadcast/Multicast Forwarding Uplink Ports 6x00 B veth 1 veth 3 B VNIC 0 Server 2 LAN Broadcast Listener All VLANs VNIC 0 B Server 1 Pre 2.0 - Broadcast traffic is pinned on exactly one uplink port (or port-channel) i.e., it is dropped when received on other uplinks All multicast groups are pinned to same uplink port Server to server multicast traffic is locally switched RPF and deja-vu check also applies for multicast traffic

UCS Switch Mode Root LAN FI acts as L2 switch Server vnic traffic follows VLAN forwarding 6x00 A Fabric A veth 3 veth 1 VNIC 0 Server 2 VLAN 10 L2 Switching VNIC 0 Server 1 MAC Learning Rapid PVST+ is used Configuration of STP parameters (bridge priority, Hello Timers etc) or VTP is not supported MAC learning/aging happens on both the server and uplink ports like in a typical Layer 2 switch

UCS Direct Attach Storage UCS 1.4 and 2.0 FCoE Storage FC Storage Upstream MDS/5k for Zoning Default Zoning FC Switching Mode MDS, 5K Security via Zoneset Merge FC zones Security via LUN Masking No Multi-Hop FCoE UCS 6100 UCS 6100 Individual FC and Appliance Ports UCS B-Series 28

UCS Direct Attach Storage 2.1 UCSM Zoning Default Disabled FCoE Storage FC Storage Service Profile Configuration Storage Connection Policies Enable per VSAN Identify group of Service Profiles Identify Targets via WWN Group Profiles to Targets Zones Automatically computed Default Zoning deprecated MDS, 5K UCS 6100 UCS 6100 UCS B-Series 29

UCS Direct Attach Storage 2.1 Multi-Hop FCoE and Unified Uplinks FCoE Uplink Port vfc created and bound to physical Ethernet Logically the same as fc ports Port Channels Supported Unified Uplink Port FcoE and Ethernet Network Port and FCoE Port Unified Storage Port Appliance Port and FCoE DAS 30

Disjoint L2 Mode

End Host Mode Disjoint L2 SW1 SW2 SW3 SW4

Disjoint L2 Pre 2.0 Workarounds Switch Mode End Host Mode Production VLAN 10-20 Backup VLAN 30-40 Production VLAN 10-20 Backup VLAN 30-40 Prune VLANs L2 Switch -A L2 Switch -B Prune VLANs Fabric Interconnect - A Fabric Interconnect - B Fabric Interconnect - A Fabric Interconnect - B Eth 0 Bare Metal OS Eth 1 Eth 0 Eth 1 Bare Metal OS

EHM Disjoint L2 Upstream > 2.0 2.0 Changes Hardware independent: UCS 2.0 and above Selectively Assign VLANs to uplinks vnic pinning decision based on VLAN membership on uplink ports Per VLAN Designated Receiver Production VLAN 10-20 Fabric Interconnect - A Backup VLAN 30-40 Fabric Interconnect - B Eth 0 Bare Metal OS Eth 1 34

vnic-a vnic-b Disjoint L2 Unsupported/Non-Working Do Not 1. Configure different range of VLANs across uplinks of a disjoint network 2. Overlap VLANs across L2 networks 3. Configure vnic with VLANs across multiple L2 networks. vnic does not get pinned if the uplink vlan membership is partial, vnic stays down 10-20 VLAN 10,30 Production VLAN 10-20 Production VLAN 10-20 Fabric Interconnect - A End Host Mode IOM-A 3 1 11,13,15,17 Adapter Backup VLAN 30-40 2 20,30-40 Fabric Interconnect - B End Host Mode IOM-B 35

EHM: Designated Receiver Checking Per VLAN DR 2.0 = Connect nxos : show platform software enm internal info vlandb id <vlanid> show interface trunk UCS(nxos)# show interface trunk Port Vlans Allowed on Trunk ---------------------------------------------------------- Eth1/16 1,5-7,1000,3000 Only Eth1/16 allows VLAN 5 Eth1/17 1,6-7,1000,3000 <snip> 36

Blade Issues

Finite State Machine (FSM) Monitoring Object Tasks FSM runs as a workflow Workflows are predefined. Stages can be skipped if: Not Needed FSM Flags (shallow discovery vs deep discovery) Each stage is an interaction between DME > Application Gateware > End Point 38

FSM Details UCS 1.4 and 2.0 Error Description for that stage Operation (workflow) Stage Description 39

FSM Details UCS 2.1 New Features Improved Task Details Complete rewrite of task descriptions Improved Step Visibility All FSM steps listed including status Displays Scheduled Tasks 40

Common Blade Issues Hardware and Management Problems Blade Discovery failed Typically Hardware UCSM Logs/Faults Adapter Issues Card Requirements KVM Connectivity Duplicate IP IP Requirements Hardware Problems SEL OS Logs 41

Configuration

Configuration Validation and Errors Profile assignment and Policy Problems Blade/Profile Status Provides overview of failure FSM May display more details about problem. Faults Service Profile fault will display configuration problems 43

Configuration Boot Issues

Boot from SAN

UCS SAN Boot Configuration/Installation Defined in Service Profile Boot Policy SAN Boot and Local HDD boot are mutually exclusive Local HDD Boot ROM is disabled in SAN Boot Check OS multipathing requirements Some Operating Systems require additional configuration, or a single path e.g. Windows 2008 single path. RHEL multipath driver 46

UCS SAN Boot Checklists and Verification Zoning and Zoneset Active Target Login (FLOGI) SAN Admin LUN Masking NPV/NPIV configuration FC Uplinks FC VSAN Membership Service Profile Boot Policy UCS Admin SAN+UCS Admin 47

UCS SAN Boot Policy Configuration Example 48

UCS SAN Boot Policy Verification Verify Boot ROM is Active during Blade boot: 49

iscsi Boot

UCS iscsi Boot Support Overview and Requirements iscsi boot from UCSM 2.0 Adapter Support Cisco VIC (no offload) Broadcom 57711 M51KR-B (Full Offload, iscsi HBA) Operating System Support ESXi 4.1U1,U2, 5.0 Windows 2008R2 RHEL 5.6,6.0,6.1 Check Support Matrix 51

UCS iscsi Setup Configuration Flow Create iscsi vnic and Boot Policy Configure Boot Information Target IP, IQN Initiator IP, IQN Modify Adapter Policy for install (Broadcom) Install OS OS Media OS Drivers Modify Adapter Policy for Boot (Broadcom) 52

UCS iscsi Boot Policy iscsi vnic Overlay vnic iscsi Adapter Policy Identify native VLAN MAC Address VIC Do not Set Broadcom Must be set 53

UCS iscsi Boot Policy iscsi Boot Parameters Set iscsi Parameters: 54

UCS iscsi Boot Policy iscsi Boot Parameters Initiator name (eui or iqn) Initiator IP Address Target name Target IP and LUN Authentication Initiator Auth to array Target Auth from array 55

UCS iscsi Boot Verification Cisco VIC M81 and 1280 56

UCS iscsi Boot Verification Broadcom M51KR-B Broadcom ROM 57

Path Trace

Ethernet Troubleshooting and Tracing

UCS Network Troubleshooting Blade communication problems Are vethernet and uplink interface up? Is VLAN tagging correct? Is MAC Address being learnt? L2/VLAN Connectivity? Default Gateway Connectivity? 60

UCS Blade Chassis Blade Server OS CNA FEX FI A FEX FI B UCS Network Troubleshooting Frame Flow Decisions - Northbound LAN Which Port port Channelling the port Algorithm channel? (2-8 choices) Which uplink/border port or port channel? Border Port Pinning (many choices) Local or remote destination? (2 choices) L2 Switching in FIs Which Fabric Port? (4 choices) Fabric Port Pinning CNA Port 1 CNA Port 2 Eth0 MAC A OS NIC Teaming Eth1 MAC B Which CNA Port? (2 choices) UCS Fabric Failover Which OS PCIe Routing Ethernet Table Interface? or (1-58 choices depending on CNA) OS NIC Teaming

UCS Blade Chassis Blade Server OS CNA FEX FI A FEX FI B UCS Network Troubleshooting Frame Flow Decisions - Southbound LAN Which downlink or port channel? (Upstream Switch Decides) Allow the frame inbound? (decision Déjà vu, depends RPF, border on switch port mode vs. end pinning host mode ) Which Fabric Extender Port? Fabric Port Pinning CNA Port 1 CNA Port 2 Eth0 MAC A OS NIC Teaming Eth1 MAC B VNTag + Offset (MAC Learning on FIs) Which Server Bay Port? (8 choices) Which PCIe Device (vnic)? (1-58 choices VNTag depending Identifier on CNA) Pass frame to OS? Dest. MAC and Ethertype binding

UCS Network Troubleshooting Service Profile Interfaces show service-profile circuit server <chassis#>/<slot#> 63

UCS Network Troubleshooting VIF Identities show host-eth-if 64

UCS Network Troubleshooting Port Information. Cisco VIC MCP Level - vnic 65

UCS Network Troubleshooting Port Information Cisco VIC Find vnic s using vnicfind command 66

UCS Network Troubleshooting Port Information Cisco VIC MCP Level Statistics: lifstats <lifid> 67

UCS Network Troubleshooting FEX/IOM Port Information Connect nxos: show fex <chassis#> detail 68

UCS Network Troubleshooting FEX/IOM Port Information show system internal fex info satport ethernet <chassis#>/<adapter#>/<slot#> Record nif (network) and hif (backplane) 69

UCS Network Troubleshooting FEX/IOM Port Information Connect iom <chassis#> Show platform software <redwood woodside> sts 70

UCS Network Troubleshooting FEX/IOM Port Information show platform software <redwood woodside> rate 71

UCS Network Troubleshooting FEX/IOM Port Information show platform software <redwood woodside> rmon 0 <interface> 72

UCS Network Troubleshooting VIF/Vethernet Information NXOS: show interface brief show interface <id> 73

UCS Network Troubleshooting MAC Address Information show mac address-table 74

UCS Network Troubleshooting VIF/Vethernet Pinning show pinning border-interface show pinning server-interfaces 75

UCS Network Troubleshooting Port Channel Information show port-channel summary 76

UCS Network Troubleshooting Port-Channel Information show port-channel load-balance forwarding path interface portchannel <#> Check Upstream for MAC Learning 77

UCS Network Troubleshooting VLAN Designated Receiver show platform software enm internal info vlandb id <vlanid> 78

SAN Troubleshooting and Tracing

UCS SAN Troubleshooting Service Profile Interfaces show service-profile circuit server <chassis#>/<slot#> 80

UCS SAN Troubleshooting VIF/vHBA Identities show host-fc-if 81

UCS SAN Troubleshooting FC Interfaces Cisco VIC Attach to fls for the ability to view SAN Boot Attributes The vnic command shows numbering of fc interfaces 82

UCS SAN Troubleshooting FC Login Attributes Cisco VIC Login Information (Target PWWN and FCID) can be obtain with login <vnicid> command Portname should match Boot Policy Configuration 83

UCS SAN Troubleshooting FC Login Information Cisco VIC The lunmap command will confirm SAN Login 84

UCS SAN Troubleshooting FC Login Information Cisco VIC The lunlist <vnicid> command displays LUN level information learnt from Array. Configured in Policy Learnt from Array 85

UCS SAN Troubleshooting FC Interface Statistics show stats vnic-stats 86

UCS SAN Troubleshooting FC Interface Statistics NXOS: show interface brief NXOS: show interface vfc <id> 87

UCS SAN Troubleshooting VFC Membership, Login and Pinning show vsan membership show npv flogi-table 88

UCS SAN Troubleshooting Northbound FC Switch show flogi database show zoneset active 89

Maintenance

UCS Troubleshooting Maintenance and Faults UCSM contains logs and faults Clearing and Log Gathering performed in UCSM 91

UCS Troubleshooting System Event Logs - Viewing Chassis and Server level Server 92

UCS Troubleshooting System Event Logs - Managing Administrators can define rules (policies) for backup and cleaning of SEL across all servers 93

UCS Troubleshooting Faults and Events Lifecycle Faults Lifecycle Events Lifecycle Raise Fault Clear Condition Clear Fault Create Event Delete Fault Delete Retention Interval or Acknowledged Clear Action Retain Delete Event Log Full 94

UCS Faults Examples 95

UCS Support Support Data Gathering Show Tech Show Tech files for sending to TAC 96

UCS Support Support Data Gathering Core Files Not included in show tech Once TFTP core Exporter is configured and enabled, dumps will be transferred Once transferred, select and move to trash can 97

UCS Support OS Troubleshooting Ping, ARP esxcfg-nics, esxcfg-vmknic, ifconfig, ipconfig ethtool, lsmod, lspci top, esxtop (n option) tcpdump, Wireshark OS Logs Event Viewer, VM-Support, sosreport OS Core Files (PSOD, BSOD) 98

Key Takeaways

UCS Troubleshooting Narrowing Down.. Define the Problem From which point to what point is the problem? (e.g. blade to blade) Do we see the problem in one direction or both? Eliminate Variables Is the problem seen on the same Fabric Interconnect? Is just one blade having trouble, or all? Are all Virtual Machines affected? Just one VLAN? Define the Topology List all ports in the traffic path VIF s, HIF s, NIF s, Server, Uplinks 100

UCS Troubleshooting What Next? Cisco Support Community http://supportforums.cisco.com Cisco Documentation http://www.cisco.com/go/ucs TAC Case http://www.cisco.com/support/ 101

Q & A

Complete Your Online Session Evaluation Give us your feedback and receive a Cisco Live 2013 Polo Shirt! Complete your Overall Event Survey and 5 Session Evaluations. Directly from your mobile device on the Cisco Live Mobile App By visiting the Cisco Live Mobile Site www.ciscoliveaustralia.com/mobile Visit any Cisco Live Internet Station located throughout the venue Polo Shirts can be collected in the World of Solutions on Friday 8 March 12:00pm-2:00pm Don t forget to activate your Cisco Live 365 account for access to all session material, communities, and on-demand and live activities throughout the year. Log into your Cisco Live portal and click the "Enter Cisco Live 365" button. www.ciscoliveaustralia.com/portal/login.ww 1