SEL-710 Motor Protection Relay

Similar documents
SEL-700G Generator and Intertie Protection Relays

SEL-2414 Transformer Monitor

SEL-2411 Programmable Automation Controller

Firmware. Conformal Coat. Secondary Input Voltage. Secondary Input Current. Extra Inputs/Outputs X A. Communications Interface D E F

USB Interface. Power Supply. Manual Raise/Lower Operators. Communications Port (Port 1) Communications Port (Port 2)

Serial Communication Card (SELECT EIA-232/485) Part Number Serial Communication 9787LA0_ (1) Note: Slot C option only.

Power Quality and Recording Field Upgrade Available SEL-734, Standard Power Quality, 32 MB Memory SEL-734P, Advanced Power Quality, 128 MB Memory*

SELect I/O Cards Part Numbers for the SEL 710 5

DCS Digital Control Expansion System

Firmware. Control Cable Interface

Maximize process uptime with the SEL-patented motor thermal model.

1280 Enterprise Series Programmable Color Touchscreen Weight Indicator/Controller

Chapter. Protos X. Configuration. In This Chapter...

Chapter. Specifications: In This Chapter...

PLC CommuniCations In This Chapter...

Protect induction and synchronous motors with one relay.

Power Series Transfer Switch

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

Chapter. Getting Started. In this Chapter...

Chapter. In This Chapter...

Power Series Transfer Switch

Power Series Transfer Switch

2 ms arc-flash protection and feeder relay in one platform

900MB Series. Analog Output Module. Four Analog Outputs. DC Current or DC Voltage. Description

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Panel Meter Economical Panel Meter for Process, Temperature and Electrical Measurement

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Protect induction and synchronous motors with one relay

Chapter. System Design and Configuration. In This Chapter:

Chapter. Maintenance and. Troubleshooting. In this Chapter...

Chapter. Accessories. In this Chapter...

RTAC. SEL Real-Time Automation Controller. Integrate station control, a web-based HMI, and logging through one reliable system.

Nexus Next Generation Power Meter for Critical Energy Circuits. Advanced Metering and Communication

Chapter. Getting Started. In This Chapter...

PLC - LonWorks Programmable Fieldbus Controller 16-bit CPU

SECTION5AE/CE SERIES INDUSTRIAL CONTROL TRANSFORMERS

Protection, Automation, and Control System. Combine subcycle line protection with complete substation bay control

PowerFlex 523 AC Drive

A low-cost, economical solution for distribution feeder protection

Advanced distribution feeder solution with integrated protection, monitoring, and control

Nexus Next Generation Power Quality Meter for Critical Energy Circuits. Advanced Metering and Communication

CHAPTER INSTALLATION AND NETWORK LAYOUTS. In This Chapter:

SEL-2440 Discrete Programmable Automation Controller

ControlLogix PLC Revision Release List Rockwell Automation Certificate No.: 968/EZ /16

Advanced Line Differential Protection, Automation, and Control System. Combine subcycle line protection with traveling-wave fault locating

Chapter. System design and. configuration. In This Chapter

Installing the H2 -EBC(100), H2 -EBC -F or H4 -EBC( -F)

PSSU/A Control Unit Installation Instructions

Overview. Features CHAPTER

DC590+ Integrator Series 2. DC Drives 3 HP HP (15A A)

Real-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller

www. ElectricalPartManuals. com Protective Relays HIGHLIGHTS PROTECTIVE FUNCTIONS ixp-420 Transformer Protection Relay

NetBiter I/O Extender User Manual

L Series. UL Recognized CSA Certified VDE Approved. Specifications. L Series. Power Inlet Filters & Power Entry Modules

PSSU/A2 Control Unit Installation Instructions

Chapter. F2-02DA-1, F2-02DA-1L 2-Channel Analog. Current Output. In This Chapter...

Chapter. Specifications. In this Chapter...

SIL-A. Overcurrent and Earth Fault Relay for Primary and Secondary Distribution. Main characteristics

ASTAT XB/XBm Remote Operator

BITRONICS 878 DIOD Product Description BITRONICS 878 DIOD DISTRIBUTED INPUT/OUTPUT DEVICE

NBT Telemetry Products NBT. SM300 Series RTUs. User Reference

PT-7728/7828 Quick Installation Guide

SEL-3421 Motor Relay HMI (With LCD) Quick-Start Guide

The Way to Timely Innovation

Nexus Transient Recorder and Power Meter With Advanced Power Quality and Communication. Communication, I/O and User Interface

Lightweight and flexible recloser control for single-phase applications

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

Converter Box Data Sheet

Series 200. Hardware Platform

1000M Gigabit Ethernet Media Converter with SFP Slot

Npefm!681F! !!!681F!Gjcfspqujd!Usbotdfjwfs! Gjcfspqujd!Ofuxpsl!Tpmvujpo!! Model 570E Features. The Fiberoptic Communications Specialists

MACH100 19" Industrial Workgroup Rack-Mount Switches

Chapter. In This Chapter...

Product Sheet ECO. Types ECG, AMF Technical data. product sheet eco ecg-amf - technical data gb v1.0.docx

HDMI and Ethernet Extender via 2 Multimode Fibers LC Duplex Connector Extends HDMI+ 10/100M Ethernet Link Up To 800 Meters

High-speed transformer differential protection for up to five terminals

One relay for safety and process continuity

Digital multimeters DMG

FAN SPEED CONTROLLERS

EVB Industrial ARCNET AT Adapter Card

SED2 Variable Frequency Drives

Chapter. Operation. In This Chapter

D90 Plus. Sub-cycle distance protection and advanced automation controller. Multilin

CVH Slot Media Converter Chassis Quick Installation Guide

4-Pole Relay. 2 Coil. [V] Hz A1 A2 60 Hz A24 A1 A20 A2

Universal SAS and ACP Cabling Guide

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

2 ms arc-flash protection and feeder relay in one platform

Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers Introduction

KUUMIC OY DATA TRANSFER FALLBACK SWITCH KU113. Technical Reference

Power Xpert Meter 350 (PXM350) three-phased DIN-rail multifunction meter

SEL-2411P Pump Automation Controller Data Sheet

Local LCD HMI - View and force I/O, and make simple configuration changes without a computer!

Power Xpert Multi-Point Meter Quick Start Guide

4 Channel 4-20mA/0-10V Industrial Media Converter

SED2 Variable Frequency Drives

VITUS 32. Large Industrial Solution. Features. Industrial Panel PC in metal cased

Signamax Connectivity Systems Gigabit Ethernet SFP Media Converter

Yokogawa Temperature Controllers. Weschler Premo BarGraph Meter /Controller SPECIFICATIONS SPECIFICATIONS ORDERING INFORMATION

Transcription:

SEL-710 Motor Protection Relay SEL-710 ase Unit Vertical hassis Front Panel Large L isplay 4 Programmable Pushbuttons w/8 LEs 8 Target LEs (6 Programmable) Operator ontrol Interface EI-232 Port Processor and ommunications ard EI-232 Port Multimode ST Fiber-Optic Serial Port IRI- Time ode or PT Power Supply ard with 2 I, 3 O I, I, I, IN urrent s ard SELERTOR QuickSet SEL-5030 Software User onfigurable Labels Instruction Manual (printed manual available) Protocols Modbus RTU SEL SII and ompressed SII SEL Fast Meter, Fast Operate, Fast SER SEL Fast Message Ymodem File Transfer SEL MIRRORE ITS ommunications 3 Expansion Slots for Optional ards Part Number: 0 7 1 0 0 SELET Power Supply with I/O Option Slot Power Supply 110 250 Vdc, 110 240 125 Vdc/Vac igital Vac, 50/60 z (SELET PSIO / 2 I / 3 O) 24 Vdc/Vac igital 48 Vdc/Vac igital 110 Vdc/Vac igital 220 Vdc/Vac igital 250 Vdc/Vac igital Power Supply 24 48 125 Vdc/Vac igital Vdc (SELET PSIO / 2 I / 3 O) 24 Vdc/Vac igital 48 Vdc/Vac igital 110 Vdc/Vac igital 220 Vdc/Vac igital 250 Vdc/Vac igital 1 1 1 1 1 1 2 2 2 2 2 2 1 of 8 WI-5180

SELET Processor oard Option Slot Processor oard (SELET PU / OM) 0 0 0 ll Slot options include EI-232 Front, Fiber-Optic Serial Port Multimode ST, SEL EI-232 Rear, IRI- SII, ompressed SII, Fast Meter, Fast Operate, Fast Message, MIRRORE ITS, and Modbus RTU EI-485 Rear, IRI- 0 1 0 EI-232 Rear, IRI-, 10/100SE-T TP* EI-232 Rear, IRI-, 10/100SE-T TP, IE 61850* EI-485 Rear, IRI-, 10/100SE-T TP* EI-485 Rear, IRI-, 10/100SE-T TP, IE 61850* EI-232 Rear, PT Thermistor EI-485 Rear, PT Thermistor EI-232 Rear, PT Thermistor, 10/100SE-T TP* EI-232 Rear, PT Thermistor, 10/100SE-T TP, IE 61850* EI-485 Rear, PT Thermistor, 10/100SE-T TP* EI-485 Rear, PT Thermistor, 10/100SE-T TP, IE 61850* EI-232 Rear, IRI-, Single 100SE-FX MM L Ethernet, Modbus TP* EI-232 Rear, IRI-, Single 100SE-FX MM L Ethernet, Modbus TP, IE 61850* 0 2 0 0 2 1 0 3 0 0 3 1 1 0 0 1 1 0 1 2 0 1 2 1 1 3 0 1 3 1 0 4 0 0 4 1 2 of 8 WI-5180

EI-232 Rear, IRI-, ual 10/100SE-T TP* EI-232 Rear, IRI-, ual 10/100SE-T TP, IE 61850* EI-232 Rear, IRI-, ual 100SE-FX MM L TP* EI-232 Rear, IRI-, ual 100SE-FX MM L TP, IE 61850* 0 6 0 0 6 3 0 8 0 0 8 3 SELET I/O ard Option Slot No ard Empty 0 X 3 igital / 4 igital Output / 1 4 125 Vdc/Vac I, 20m nalog Output (SELET 3 I / 4 O / 1 O) (1) 24 Vdc/Vac I, 48 Vdc/Vac I, 110 Vdc/Vac I, 220 Vdc/Vac I, 250 Vdc/Vac I, 4 igital / 4 125 Vdc/Vac I, igital Output (SELET 4 I / 4 O) 24 Vdc/Vac I, 48 Vdc/Vac I, 110 Vdc/Vac I, 220 Vdc/Vac I, 250 Vdc/Vac I, 125 Vdc/Vac I, Fast igh urrent Interrupting 24 Vdc/Vac I, Fast igh urrent Interrupting 1 1 1 1 1 1 3 of 8 WI-5180

48 Vdc/Vac I, Fast igh urrent Interrupting 110 Vdc/Vac I, Fast igh urrent Interrupting 220 Vdc/Vac I, Fast igh urrent Interrupting 250 Vdc/Vac I, Fast igh urrent Interrupting 8 nalog ±20 m or ±10 V (SELET 8 I) Jumper Selectable* 5 X 4 nalog / 4 ±20 m or ±10 V 6 X nalog Output (SELET 4 I / 4 O) (2) Jumper Selectable* Serial ommunication ard (SELET EI- 232/485)* 0 8 igital (SELET 125 Vdc/Vac* 8 I) 3 4 igital / 3 125 Vdc/Vac I, igital Output (2 Form, 1 Form ) (SELET 4 I / 3 O) 24 Vdc/Vac I, 48 Vdc/Vac I, 110 Vdc/Vac I, 220 Vdc/Vac I, 250 Vdc/Vac I, SELET I/O ard Option Slot 24 Vdc/Vac* 3 48 Vdc/Vac* 3 110 Vdc/Vac* 3 220 Vdc/Vac* 3 250 Vdc/Vac* 3 No ard Empty 0 X 3 igital / 4 igital Output / 1 4 125 Vdc/Vac I, 20m nalog Output (SELET 3 I / 4 O / 1 O) (1) 24 Vdc/Vac I, 48 Vdc/Vac I, 110 Vdc/Vac I, 220 Vdc/Vac I, 4 of 8 WI-5180

250 Vdc/Vac I, 4 igital / 4 125 Vdc/Vac I, igital Output (SELET 4 I / 4 O) 24 Vdc/Vac I, 48 Vdc/Vac I, 110 Vdc/Vac I, 220 Vdc/Vac I, 250 Vdc/Vac I, 8 nalog ±20 m or ±10 V (SELET 8 I) Jumper Selectable* 4 nalog / 4 ±20 m or ±10 V nalog Output (SELET 4 I / 4 O) (2) Jumper Selectable* 1 1 1 1 1 1 5 X 6 X 10 RT (SELET 10 RT)* 9 X 8 igital (SELET 125 Vdc/Vac* 3 8 I) 4 igital / 3 125 Vdc/Vac I, igital Output (2 Form, 1 Form ) (SELET 4 I / 3 O) 24 Vdc/Vac I, 48 Vdc/Vac I, 110 Vdc/Vac I, 220 Vdc/Vac I, 250 Vdc/Vac I, SELET I/O ard Option Slot E 24 Vdc/Vac* 3 48 Vdc/Vac I* 3 110 Vdc/Vac I* 3 220 Vdc/Vac I* 3 250 Vdc/Vac I* 3 No ard Empty 0 X 3 igital / 4 igital Output / 1 4 125 Vdc/Vac I, 20m nalog Output (SELET 3 I / 4 O / 1 O) (1) 5 of 8 WI-5180

24 Vdc/Vac I, 48 Vdc/Vac I, 110 Vdc/Vac I, 220 Vdc/Vac I, 250 Vdc/Vac I, 4 igital / 4 125 Vdc/Vac I, igital Output (SELET 1 4 I / 4 O) 24 Vdc/Vac I, 1 48 Vdc/Vac I, 1 110 Vdc/Vac I, 1 220 Vdc/Vac I, 1 250 Vdc/Vac I, 1 8 nalog ±20 m or ±10 V (SELET 8 I) Jumper Selectable* 5 X 4 nalog / 4 ±20 m or ±10 V 6 X nalog Output (SELET 4 I / 4 O) (2) Jumper Selectable* 3-Phase Voltage (SELET 3 VI) 300 Vac Maximum* 7 1 3 urrent (Motor Voltage: 300 Vac 7 2 ifferential) / 3-Phase Maximum Voltage urrent: 1 and 5* (SELET 3 I / 3 VI) 8 igital (SELET 125 Vdc/Vac I* 8 I) 3 4 igital / 3 125 Vdc/Vac I, igital Output (2 Form, 1 Form ) (SELET 4 I / 3 O) 24 Vdc/Vac I, 48 Vdc/Vac I, 110 Vdc/Vac I, 24 Vdc/Vac I* 3 48 Vdc/Vac I* 3 110 Vdc/Vac I* 3 220 Vdc/Vac I* 3 250 Vdc/Vac I* 3 6 of 8 WI-5180

220 Vdc/Vac I, 250 Vdc/Vac I, SELET I/O ard Option Slot Z 4 urrent 1 mp Phase, 1 mp (SELET 4 I) Neutral 1 mp Phase, 5 mp Neutral 1 mp Phase, 2.5 m igh Sense Neutral 5 mp Phase, 5 mp Neutral 5 mp Phase, 1 mp Neutral 5 mp Phase, 2.5 m igh Sense Neutral 8 1 8 2 8 3 8 5 8 6 8 7 onformal oat None 0 onformal oated ircuit oards* 1 ccessories Literature Printed Instruction Manual (3) P M 7 1 0-0 1 * dditional ost (1) Only one (1) 3 I /4 O / 1 O card per chassis. (2) Only one (1) 4 I / 4 O card per chassis. (3) One complimentary printed instruction manual is available upon request with each product purchased. NOTES: - ase unit includes slots, (EI-232), Z, MI, and Front EI-232 Port. - Order 3 I / 3 VI card for Motor ifferential Protection and Voltage. - Order 3 VI ard for Voltage only. - ownload SELERTOR QuickSet SEL-5030 software for free at https://www.selinc.com/softwaresolutions/. SELERTOR QuickSet on (503001WX4) is available upon request. - configuration kit is provided for the front panel configurable labels (packaged in the shipping box). For additional kits, order SEL part number 9260027. - Order external powered RT module SEL-2600 or external powered RT module SEL-2600 using WI-5997 to interface remote external resistive temperature devices (RT) or use internal RT inputs option in Slot. - The SEL-710 can be ordered with a manual. - The SEL-710 option cards are orderable separately for field installation. Use WI-5932 and contact your SEL representative to order option cards. - For SEL-710 Mounting ccessories including adaptor plates,dust protectors, etc go to www.selinc.com/mountingccessories/. - Remote I/O with SEL-2505 Remote I/O Module (SEL-2812 compatible ST option only). 7 of 8 WI-5180

2350 NE opkins ourt - Pullman, W 99163 US Phone: +1.509.332.1890 - Fax: +1.509.332.7990 8 of 8 WI-5180