Effect of the Certification on Chillers Energy Efficiency

Similar documents
THE EUROPEAN REFERENCE

Performance Certification : From Energy Efficiency To Indoor Air Quality. By: Eric Foucherot

Chillventa Specialist Forums 2018 Chillventa Fachforen 2018

The European Programme for Energy Efficiency in Data Centres: The Code of Conduct

Energy Engineering: Tools and Trends

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

CHILLERS & HEAT PUMPS DYNACIAT HIGH ENERGY PERFORMANCE WITHIN OPTIMISED FOOTPRINT

PROMOTION OF HIGHER EFFICIENCY ROOM AIR CONDITIONERS IN THAILAND: NATIONAL POLICY ROADMAP. Endorsed by

ACCREDITATION: A BRIEFING FOR GOVERNMENTS AND REGULATORS

Data Center Energy Savings By the numbers

Trailblazer AGZ-E air-cooled scroll chillers

EU Code of Conduct on Data Centre Energy Efficiency. Endorser Guidelines and Registration Form. Version 3.1.0

Energy-efficient heating, ventilation and air-conditioning Technologies for certified buildings

Second Stakeholder Meeting for Nonresidential HVAC Proposals Based on ASHRAE Revisions to Waterside Economizer

A SIMPLE CHILLER MODEL FOR HOURLY TIME STEP APPLICATIONS. Gerhard Zweifel

30XAV & 30XWV. Air and water-sourced, variable-speed screw units. AquaForce with Greenspeed intelligence, Because you should not have to choose.

that may have a direct effect on your bottom line. The question

EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL

2018 Business Cooling Equipment Rebate Application

COMMISSION REGULATION (EU) No /.. of XXX

COMMISSION DELEGATED REGULATION (EU) No /.. of XXX

Pathfinder AWV air-cooled screw chillers

GUIDANCE AND INTERPRETATION DOCUMENTS TO THE REQUIREMENTS FOR THE COMPETENCE OF CONFORMITY ASSESSMENT BODIES

Improving the climate for data centers

Session 6: Data Center Energy Management Strategies

AUTOMATIC COMMERCIAL ICE-MAKERS CERTIFICATION PROGRAM

1- ASECAP participation

Friedrich Smaxwil CEN President. CEN European Committee for Standardization

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

FLORIDA STATE UNIVERSITY MASTER PLAN 10 Utilities

CGWN/CCUN indoor liquid chillers The compact AquaStream² solution

Commercial HVAC Efficiency Regulations and Refrigerants Are Changing: Are You Ready?

Mandate to CEN, CENELEC and ETSI for Standardisation in the field of electric motors

EUROPEAN ACCREDITATION LEGAL FRAMEWORK

Ecolibrium. Cloud control. Keeping data centres cool. OCTOBER 2018 VOLUME 17.9 RRP $14.95 PRINT POST APPROVAL NUMBER PP352532/00001

CHAPTER/REGIONAL TECHNOLOGY AWARD - SHORT FORM

APPLIED SYSTEM AWS FAMILY FOR LARGE APPLICATIONS PRODUCT LEAFLET. Capacity from 600 to 2,010kWr. Engineered for flexibility and performance

Silicon Valley Power Data Center Program Rebate Application

CEN and CENELEC Position Paper on the draft regulation ''Cybersecurity Act''

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.

PEFC N 04 Requirements for certification bodies and accreditation bodies

WATER-COOLED WATER-CHILLING AND HEAT PUMP WATER-HEATING PACKAGES USING THE VAPOR COMPRESSION CYCLE

We design and produce special units for applications in air conditioning, refrigeration and air treatment systems, specifically developed to meet our

Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A. Company Profile

ECP New Program. Hygienic Air Handling Units 29 September Krakow

Trane mytest Water-cooled Chiller Performance Validation What you spec is what you get *

CARBON FOOTPRINT MONITORING THROUGH INNOVATION

Planning a Green Datacenter

REPORT FROM THE COMMISSION TO THE EUROPEAN PARLIAMENT AND THE COUNCIL

ACCREDITATION COMMISSION FOR CONFORMITY ASSESSMENT BODIES

GreenS DEPARTMENT OF ENVIRONMENT MINISTRY OF AGRICULTURE, RURAL DEVELOPMENT & ENVIRONMENT NATALIA GEORGIOU

Application Manual. Shark. Software for the simulation of refrigeration equipment and air conditioners

Energy Saving in Cleanrooms

DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency

HPE Energy Efficiency Certification Service

THE CURRENT STATE OF DATA CENTER ENERGY EFFICIENCY IN EUROPE. White Paper

ITU-T L Energy efficiency metrics of a base station site

EUROPEAN DATA CENTRE STANDARDS

New Design Strategies for Energy Saving. Intelligent free-cooling

5 th Meeting of the European Heritage Legal Forum. Wolfgang Karl Göhner

DATACOM COOLING CERTIFICATION PROGRAM

COMMERCIAL FURNACES CERTIFICATION PROGRAM

ecoenergy Innovation Initiative Research and Development Component Public Report

Present implementation: Condensing units, proces chillers (LT, MT) and professional storage cabinets. Per Henrik Pedersen

THE BASIC REQUIREMENT OF EVAPORATIVE COOLING EQUIPMENT ULTIMATE QUALITY

How the European AuditAC project can benefit the air conditioning sector

Cybersecurity. Quality. security LED-Modul. basis. Comments by the electrical industry on the EU Cybersecurity Act. manufacturer s declaration

Global Optimisation of Chiller Sequencing and Load Balancing Using Shuffled Complex Evolution

Committee on the Internal Market and Consumer Protection

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

INSPIRE status report

Reliable, fast and intuitive daylight simulation for 3D architectural and urban models directly integrated within SketchUp graphic modeler

Temperature Control and Cooling Technology First Choice in Temperature Control

Upstream Rebate Programs UC Davis Meeting

Why would you want to use outdoor air for data center cooling?

INAB Mandatory and Guidance Documents Policy and Index

NIST Designation of CABs: Upcoming Changes for the US and EU Review for Japan

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

INAB Mandatory and Guidance Documents Policy and Index

ACCREDITATION COMMISSION FOR CONFORMITY ASSESSMENT BODIES

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

TTMD is 25 Years Old. Tuba Bingöl Altıok Vice President of TTMD

CEMR position paper. on the recast of the proposal for a directive on waste electrical and electronic equipement (WEEE) COM(2008)810/4

ICS COOL ENERGY THE TEMPERATURE CONTROL SPECIALISTS

LEVELUPS T3. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability and Robust Protection for Industrial Loads

DATA CENTRE CODES AND STANDARDS

ICE STORAGE BINS CERTIFICATION PROGRAM

European Policies for Energy Efficiency in ICT Paolo Bertoldi European Commission DG JRC

1.0 Executive Summary. 2.0 Available Features & Benefits

Beyond BREEAM Excellent DCs. Cobalt Data Centre Campus

USTER TESTER 5-C800. The filament yarn inspection system. Technical Data

Refrigeration Systems. Products, solutions and services from ENGIE Refrigeration

CalCERTS Title 24 & Whole House Rater HERS Certification Training Overview. CalCERTS HERS Rater Certification Courses

BCS Specialist Certificate in Service Desk and Incident Management Syllabus

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

LCP Hybrid Efficient performance with heat pipe technology

Green Data Centers A Guideline

Green Computing: Realities and Myths

Total Building Solution Welcome everyone. Chris Vandebrouck June 2017

Transcription:

Effect of the Certification on Chillers Energy Efficiency Yamina Saheb Eurovent Certification Paper presented at IEECB, April 2006, Frankfurt, Germany 4 Sulejman Becirspahic Eurovent Certification Jérôme Simon Eurovent Certification Abstract: Energy efficiency has become one of the most important issues for HVAC industry. Indeed, the implementation of Kyoto Protocol has now a high priority for the European Union and strong measures should be applied to achieve its targets, like an 8% reduction of equivalent CO 2 emission between 2008 and 2012. For our industry, the best way to meet this important challenge is to be proactive and propose relevant actions in advance instead of waiting for some mandatory measures decided by the European Commission or the National Authorities. Within this framework, two important measures have been decided by Eurovent Chillers Manufacturers. The first action, February 2005, was the implementation on a voluntary basis, of the classification for chillers. The objective of the classification is double: 1. Promote the more efficient chillers 2. Facilitate the elimination, in the near future of the low efficient ones. Based on existing chillers presented to Eurovent certification, the limits between classes have been defined, for gross EER, for each type of chillers. It is now easier for consultants, engineers and technical specialists to select efficient chillers from Eurovent directories, www.eurovent-certification.com. The second issue was the use of the chillers and the real annual energy consumption. As the part load efficiency has a very strong impact on energy consumption, Eurovent has initiated the SAVE study, EECCAC-Energy Efficiency and Certification of Central Air Conditioners. An integrated energy efficiency index called ESEER, European Seasonal Energy Efficiency Ratio, equivalent to IPLV, Integrated Part Load Value, developed in the US and used by ARI, was established for the European conditions. The study was finalised in 2004, the experimental application started in 2005 and the mandatory implementation for Eurovent manufactures is scheduled for June 2006. From the certified part load table, Eurovent will compute ESEER allowing the comparison of chillers performances in the cooling mode. This global single figure shall be published in Eurovent directory together with cooling capacity and power input for standard conditions at full load. This paper presents the evolution of chillers efficiency, analyses Eurovent chillers classification after one year of implementation, describes Eurovent certification for European Seasonal Energy Efficiency Ratio for chillers and gives an overview of next steps for chillers certification. Introduction According to EECCAC-Energy Efficiency and Certification of Central Air Conditioners-project (1), the cooled area in 2010 in Europe will be 2200Mm 2. These expectations are confirmed by the ever growing number of chillers sold in Europe every year, as shown in Figure 1. As a consequence of the increasing of the installed units,

the electrical end-use and the efficiency of central air conditioning systems are becoming an important issue for the European Commission and the National Authorities. At present, the Energy Labelling Directive is restricted to household appliances. Indeed, the label is mandatory only for Room Air Conditioners with capacity equal to or lower than 12 kw. However, Eurovent established classification for full load Energy Efficiency Ratio of each type of chillers. The classification follows the A to G approach used in the European Energy Label for household appliances but the limits between classes have been defined for the existing chillers as listed in Eurovent directory, see Table1 for cooling mode. Table 1: Chillers Energy Classification in Cooling Mode EER Class Air Cooled Water cooled Remote condenser A EER 3.1 EER 5.05 > = 3,55 B 2,9 EER< 3,1 4,65 EER < 5,05 3,40 EER < 3,55 C 2,7 EER< 2,9 4,25 EER < 4,65 3,25 EER < 3,40 D 2,5 EER< 2,7 3,85 EER < 4,25 3,10 EER < 3,25 E 2,3 EER< 2,5 3,45 EER < 3,85 2,95 EER < 3,10 F 2,1 EER< 2,3 3,05 EER < 3,45 2,80 EER < 2,95 G < 2,1 < 3,05 < 2,8 The Energy Performance Building Directive requires calculation of building energy performance and regular inspection of central air conditioners and chillers with more than 12 kw cooling capacity. On the basis of this inspection, which shall include an assessment of the efficiency of the system and the sizing compared to the cooling requirements of the building, the competent authorities will ask the users to improve or replace the installed system by more efficient one. The transposition of this Directive in Member States shall oblige the National Authorities to develop policy measures for energy savings. However, these measures only address the efficiency of the end-use equipment as determined under standard conditions at full load and will not realise many of the potential energy savings which are related to operating conditions at part load. To be really effective, energy efficiency options have to be defined not on the basis of nominal operating conditions but on a variety of part load conditions, which better reflect the central air conditioners operating modes that occur in real use. For this reason, Eurovent developed a European Seasonal Energy Efficiency Ratio, ESEER, index based on ARI approach to determine the Integrated Part Load Value, IPLV. The manufacturers will provide their customers with a map of performance, not only at the four arbitrary percentages and temperatures. The customer can rely on ESEER computed from this map or compute its specific ESEER for its specific demand. As there is no European or ISO standard for part load testing conditions, Eurovent standard, 6-C003-2006 has been amended including testing procedure for part load conditions. The implementation of ESEER certification is scheduled for 2006 and the classification of chillers will be reviewed for translation into part load classes. Number of units 45 000 40 000 35 000 30 000 25 000 20 000 15 000 10 000 Figure 1: Chillers sales evolution in EU 5 000 0 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 Year Water Cooled Air Cooled Air to water 5

EER EER 5,5 5 4,5 4 3,5 3 2,5 2 1,5 1 0,5 0 2003 8 7 6 5 4 3 Energy Efficiency Classification Analysis Starting with 1994, Eurovent is issuing a directory of certified products sold on the European market, giving information on certified performances. At the beginning, the information was limited to cooling capacity and electrical power absorbed; then in 2002, it was extended to Energy Efficiency in cooling and heating mode. The last improvement was in 2005 with the publication of the classification of the chillers according to Table 1. Using data published in the Eurovent directories since 2003 (2), we can see the evolution of EER for air cooled, Figure 2, and water cooled chillers, Figure 3. Based on the standard test conditions, the mean EER for air cooled units is 2.56 while the average EER for water Figure 2: EER Evolution for Air Cooled Chillers 2004 Year 2005 EER Min EER Mean EER Max Figure 3: EER Evolution for Water Cooled Chillers 2006 cooled units is 4.05. This difference is not inherent to chillers, but rather represents the temperature regime found in cooling towers. Nevertheless, water cooled systems are expensive because of the additional cost of using either a cooling tower or of accessing a natural water supply. Therefore, they are used only for large systems. On a voluntary basis, Eurovent implemented a classification according to energy efficiency. The purpose of this measure is double fold: 1. For high efficient chillers, the energy efficiency will be highlighted as the best units for each type being in Class A could be strongly promoted. 2. Minimum energy efficiency could easily be implemented, either on voluntary basis or decided by the European Commission. The proposed classification is not labelling, as no label will be used. Energy efficiency of chillers expressed by classes is indicated as Eurovent Class A or Eurovent Class B in manufacturers catalogues and Eurovent Directory of Certified products. Based on existing chillers list published in Eurovent directory, limits between classes have been decided; see Table 1 for cooling mode, taken into account the following considerations: 1. Classification concerns gross EER at full load operation. When part load characteristics will be implemented, classes will be defined with equivalent ESEER. 2. To avoid confusion and possible use of classification by non-certified manufacturers, the designation Eurovent Class A or Eurovent Class B will be used and legally protected. 3. For low noise chillers, the class will correspond to full load operation with maximum fan speed. The same class will be used for lower fan speeds. The classification has been implemented in February 2005; the distribution of number of units in each class is shown in Table 2. 2 1 0 2003 2004 2005 Year EER Min EER Mean EER Max 2006 It is too early to see the influence of this classification on energy efficiency. However, the distribution shows that 7% of certified chillers are in Eurovent Class A and in total only 5% of the certified chillers are in Eurovent Class G. 6

Table 2: Distribution of units in each class Class/ 0-50- 100-150- 200-500- >1000 Total kw 50 100 150 200 500 1 000 A 85 12 4 7 72 85 115 380 B 114 51 46 21 142 179 112 665 C 203 75 76 40 206 229 137 966 D 244 143 106 80 295 213 80 1 161 E 383 131 121 84 432 246 98 1 495 F 287 62 54 52 125 68 29 677 G 152 14 10 8 41 31 19 275 Total 1 468 488 417 292 1 313 1 051 590 5 619 European Seasonal Energy Efficiency Ratio 1. Definition Until now, the chillers are tested according to EN 14511 at full load conditions only while energy consumption is not covered by full load EER given in such a standard but by the average part load EER, often called Seasonal EER. This is largely used in the US market and called IPLV, Integrated Part Load Value. The percentage of operating hours assigned to each part load condition in IPLV is corresponds to the US climate and buildings but could not be applied to the European ones. Eurovent established ESEER which represents the universe of EU buildings and climates. The European Seasonal Energy Efficiency Ratio, ESEER, is a weighed formula enabling to take into account the variation of EER with the load rate and the variation of air or water inlet condenser temperature. ESEER = A.EER A + B.EER B + C.EER C + D.EER D With the following weighing coefficients: A = 0.03 B = 0.33 C = 0.41 D = 0.23 For the following part-load ratings Air cooled chillers: Load Ratio (%) 100 35 75 30 50 25 25 20 Water cooled chillers Load Ratio (%) 2. ESEER Certification Procedure Air temperature at condenser inlet ( C) Water temperature at condenser inlet ( C) 100 30 75 26 50 22 25 18 ESEER enables to calculate the seasonal efficiency for all the European chillers. The constraint was to minimise the testing time while ensuring maximum precision. Contrary to ARI certification where one full load condition and three part load conditions are tested, in Eurovent certification, the ESEER procedure will be added to the existing one. That means, we will test one standard rating, one application rating selected by Eurovent and in addition one part load condition also selected by 7

Eurovent. The manufacturer has to fill in Table 3 by giving first the number of stages of the chillers. Once notified, the table corresponding to the number of stages is built automatically. Then the manufacturer has to fill in the cooling capacity and absorbed electrical power for each condition and each stage. ESEER procedure will calculate EER for each part load condition, and then compute ESEER value using the red cells shown in the Table 3. It also shows the intermediary points that have been calculated at 25, 50 and 75% load points in order to use the weighed coefficients derived for the ESEER. Table 3: : ESEER Calculation Capacity stage number 4 Temperatures FULL LOAD STAGE 2 STAGE 3 STAGE 4 Cycling coefficient 0,9 35 Cooling Capacity 153,7 116,8 81,5 38,4 Electrical Power 60 43,8 26,9 14,2 Weighting coefficients 30 Cooling Capacity 166,3 126,4 88,1 41,6 25% - 50% - 75% - 100% Electrical Power 53,9 39,4 24,2 12,7 0.23-0.41-0.33-0.03 25 Cooling Capacity 176,3 134,0 93,4 42,9 Electrical Power 48,9 35,8 22,0 11,9 20 Cooling Capacity 185,0 137,0 93,0 50 ESEER 3,87 Electrical Power 43,8 32,8 20,7 10,9 Part load EER 100% 75% 50% 25% 2,56 3,29 4,11 4,45 8 The cycling coefficient is defined as fellow: Cc = 1- Measured sleep power / (Pe (c)) (electric power of the cycling stage for given source temperatures) For 2006 test campaign, a default value of 0,9 will be used for the cycling coefficient for all chiller. The laboratory will measure, when the chiller is OFF, the sleep power and calculate the cycling coefficient for each tested unit. According to these calculations the default value will be revised by category of chiller for the next year test campaign. 3. Part load Testing Procedure: The following rating conditions are used to test chillers at part load conditions: For air cooled chillers: 1. The leaving water temperature is set at 7 C 2. The evaporator water-flow rate is equal to the standard rating waterflow rate 3. The air-flow rate is controlled by the chillers For water cooled chillers: 1. The leaving water temperature is set at 7 C 2. The evaporator water-flow rates are equal to the standard rating water-flow rates 3. The condenser water flow rate is controlled by the chillers. If the chillers don t control it, the condenser water flow rate will be equal to the standard rating water flow rate. For air cooled chillers, the condenser fan(s) should be operated by the control of the chillers. Whenever cycling of the condenser fan(s) occurs, the test should be led as follows: An acquisition time period of 1 hour is required. Tolerance on leaving water temperature can exceed the maximum permissible deviation. If cycles exceed 1 minute, an entire number of periods shall be acquired.

Conclusion: Eurovent has done and is still doing a lot for improving energy efficiency of HVAC products, all on a voluntary basis. This paper has presented the work in the field of chillers, namely certification of EER, classification of chillers and certification at part load conditions. Next steps will be the elimination of Class G chillers (poorly efficient) and reviewing the classification of chillers according to ESEER instead of EER. References: (1): Energy Efficiency and Certification of Central Air Conditioners (EECCAC), Final report, April 2003. Co-ordinator: Jérôme ADNOT, assisted by Paul WAIDE (2): Eurovent Directory 2003, 2004, 2005 and 2006 (3): Performances saisonnières des groupes de production d eau glacée, PhD Thesis, presented at Ecole des Mines de Paris, May 2004 by Philippe RIVIERE 9th REHVA World Congress Clima 2007 Invitation It is our pleasure to welcome you to the Clima 2007, the leading international scientific congress in the HVAC area in year 2007. The 9 th REHVA World Congress will offer scientists, industry, building owners, end users, consultants, engineers, architects and policy-makers a platform for the exchange of scientific knowledge and technical solutions. The special congress theme is wellbeing of people indoors. The congress will cover all aspects of HVAC technology including building automation in all types of buildings. applying the latest research results and technical innovations into practise. Mika Halttunen, President Olli Seppänen, President of the Scientific Committee Themes and Scope The scope of the Congress is HVAC and its applications in creating wellbeing in indoor environments in an environmentally sustainable manner in all types of buildings. The WellBeing Indoors Clima 2007 congress and web service open a global window to the scientific knowledge and innovative applications of building services. The focus is on improving wellbeing in buildings in a sustainable manner by 9