DEVIwet 230V room thermostats for hydronic floor heating Description DEVIwet Dial DEVIwet is a range of room thermostats for hydronic floor heating applications. The thermostats are mains powered and can be used as a stand-alone thermostats or in combination with wiring center 088H0016. DEVIwet can control up to five thermal actuators and comes in three versions: DEVIwet Dial: uses a relay output. The room temperature is set with the dial in a range from 5 to 30 C. The dial can be removed, allowing limitation pins to be used to limit the setpoint range. DEVIwet Display: uses a triac output. The room temperature is set in a range from 5 to 35 C via a touch on glass interface with a shine through display. The display is OFF in normal operation. DEVIwet Display/Programmable DEVIwet Programmable: uses a triac output. The room temperature is set in a range from 5 to 35 C via a touch on glass interface with a shine through display. The display is OFF in normal operation. The user can choose between 7 pre-defined heating schedules. A schedule can be temporarily overrided by using the three mode keys. The thermostat can also operate without scheduling (constant room temperature setpoint). The thermostat uses forecast (adaptive learning). Features Dial Display Programmable eutral design and simple user interface Compatible with 3rd party wall frames Very high UV-resistance Can be used with 230 V C or O actuators Frost protection setting O/OFF control Range limitation via pins Accurate PW-control Shine through display Range limitation via user menu Valve eercise feature Can be optimized for different heatsources Seven pre-defined schedules and forecast Can be used in systems with cooling Can be used with floor sensor (optional) VDBA102 Danfoss FHH 2017.01 1
Ordering Product Size For junction bo Code no. DEVIwet Dial 80 80 mm Euro, Ø68 mm 088U2000 DEVIwet Display 80 80 mm Euro, Ø68 mm 088U2001 DEVIwet Programmable 80 80 mm Euro, Ø68 mm 088U2002 Accessories Product Description Code no. Danfoss FH-WC, 230V Wiring center, 8 channels, up to 16 outputs 088H0016 DEVIwet Floor Sensor 47 kω, 3 m, IP 67 088U2010 Technical specifications Dial Display Programmable User interface Dial Capacitive touch and shine through display User interface features - Display type - Heating icon, arrow up/down, confirm key, back key Heating icon, arrow up/down, confirm key, back key, Home, Away, ight, Settings Hybrid: red single ED s and custom segment Display features - Switches OFF after 10 sec. with no interaction Automatic daylight saving time - - Standard (can be turned off) Heating schedules - - 7 pre-defined Change over, cooling - - Yes, via 230 V terminal Global setback/away - - Yes, via 230 V terminal Temperature setting range 5-30 C 5-35 C Frost protection setting 5 C Ambient temp., storage -20 to 60 C Ambient temp., in application 0 to + 40 C Controller, type On/Off Adjustable Pulse Width odulation a. continuous load (output) a. inrush current (actuator) < 50 ma /10 W (= 5 pcs. Danfoss TWA actuators) 3 A 100 ms Power consumption 0.4 W 0.2 W Power supply (ecl. actuators) Sensor, room 220-240 V, 50/60 Hz 47 kω, TC Sensor, floor (optional) - - TC 47 kω, 3 m, IP 68 Shell material White parts: PC ASA. Grey parts: PC, 10% glass IP class 21 Protection class Class II ErP class Approval Colour Dimensions (1%) (2%) CE, RohS, WEEE White RA9010 / Dark Grey RA7024 80 80 11 mm 2 Danfoss FHH 2017.01 VDBA102
Application eamples, DEVIwet Dial Wiring without wiring center, neutral wire from main installation 6430 ordborg DEVIwet Dial 230V IW a. load: 10W/50mA 0883485 V00 oad oad C O in. 3G1.5 cable to thermostat a. 5 actuators, type C or O, 230V a. 10 W / a. 50 ma continuous load a. 3 A inrush current 100 ms 6430 ordborg DEVIwet Dial 230V IW a. load: 10W/50mA 0883485 V00 oad oad C O in. 4G1.5 cable to thermostat a. 5 actuators, type C or O, 230V a. 10 W / a. 50 ma continuous load a. 3 A inrush current 100 ms Wiring with wiring center 6430 ordborg DEVIwet Dial 230V IW a. load: 10W/50mA 0883485 V00 oad C oad O OAD FH-WC 1) 088H0016 in. 3G1.5 cable to thermostat (not counting Protective Earth) a. 5 actuators, type C, 230V a. 10 W / a. 50 ma continuous load a. 3 A inrush current 100 ms 1) ote! Wiring center FH-WC 088H0016 only supports C actuators. VDBA102 Danfoss FHH 2017.01 3
Application eamples, DEVIwet Display Wiring without wiring center, neutral wire from main installation 6430 ordborg DEVIwet Display 230V IW a. load: 10W/50mA 0883488 V00 oad in. 3G1.5 cable to thermostat a. 5 actuators, type C or O, 230V a. 10 W / a. 50 ma continuous load a. 3 A inrush current 100 ms 6430 ordborg DEVIwet Display 230V IW a. load: 10W/50mA 0883488 V00 oad in. 4G1.5 cable to thermostat a. 5 actuators, type C or O, 230V a. 10 W / a. 50 ma continuous load a. 3 A inrush current 100 ms Wiring with wiring center 6430 ordborg DEVIwet Display 230V IW a. load: 10W/50mA 0883488 V00 oad OAD FH-WC 1) 088H0016 in. 3G1.5 cable to thermostat (not counting Protective Earth) a. 5 actuators, type C, 230V a. 10 W / a. 50 ma continuous load a. 3 A inrush current 100 ms 1) ote! Wiring center FH-WC 088H0016 only supports C actuators. 4 Danfoss FHH 2017.01 VDBA102
Application eamples, DEVIwet Programmable Wiring without wiring center, neutral wire from main installation 6430 ordborg a. load: 10W/50mA 0883491 V00 oad TC in. 3G1.5 cable to thermostat a. 5 actuators, type C or O, 230V a. 10 W / a. 50 ma continuous load a. 3 A inrush current 100 ms 6430 ordborg a. load: 10W/50mA 0883491 V00 oad TC in. 4G1.5 cable to thermostat a. 5 actuators, type C or O, 230V a. 10 W / a. 50 ma continuous load a. 3 A inrush current 100 ms Wiring with wiring center 6430 ordborg a. load: 10W/50mA 0883491 V00 OAD FH-WC 1) 088H0016 oad TC in. 3G1.5 cable to thermostat (not counting Protective Earth) a. 5 actuators, type C, 230V a. 10 W / a. 50 ma continuous load a. 3 A inrush current 100 ms 1) ote! Wiring center FH-WC 088H0016 only supports C actuators, and does not support cooling change-over or global setback. VDBA102 Danfoss FHH 2017.01 5
Application eamples, DEVIwet Programmable How to set thermostats to cooling mode from eternal device 6430 ordborg a. load: 10W/50mA 0883491 V00 oad TC S S: Can be mechanical switch Summer / Winter or relay activated by eternal device. Use the same phase which supplies the thermostat. The thermostat/room remains in cooling mode as long as the phase is live onto the terminal. ote! Switch not in delivery. How to set thermostats to Away (global standby) from eternal device 6430 ordborg a. load: 10W/50mA 0883491 V00 oad TC S: Can be mechanical switch Home / Away or relay activated by eternal device. S Use the same phase which supplies the thermostat. The thermostat/room remains in Away mode as long as the phase is live onto the terminal. ote! Switch not in delivery. How to install a floor sensor 6430 ordborg a. load: 10W/50mA 0883491 V00 oad TC 1. R > 5 cm. 2. Anchor electrical pipe firmly before laying concrete. 3. Concrete. 4. End of pipe must be closed / sealed. 1. 2. 3. 4. ote! Use DEVIwet 47 KΩ TC floor sensor, code no.: 088U2010. Always route eternal sensors in a suitable electrical pipe! 6 Danfoss FHH 2017.01 VDBA102
Dimensions 60 47 71 71 80 51 11 23 DEVIwet Dial 088U2000 80 60 47 71 71 80 51 11 23 DEVIwet Display 088U1010 & Programmable 088U2002 80 VDBA102 Danfoss FHH 2017.01 7
Floor Heating Hydronics Ulvehavevej 61 DK-7100 Vejle Phone: +45 7488 8500 Fa: +45 7488 8501 heating@danfoss.com www.floorheating.danfoss.com Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of. All rights reserved. 8 Danfoss FHH 2017.01 VDBA102