/TLC. Additional Manual for TEX-LCD series and TEX-LIGHT series. Manufactured by

Similar documents
TCPIPINT-SCMN USER MANUAL. Manufactured by R.V.R ELETTRONICA S.p.A. Italy

A TECHNICAL INFO A. External GSM AT420 DATE :

PJ500C-LCD, PJ700C-LCD & PJ1000-LIGHT

CFO100 Series. User Manual CRT141 & CRR141. CFO141 User Manual, , rev001

The SOUND4 IMPACT. Dual Power supply 2 Processing path: FM & HD

SS-10 3G USER MANUAL FIXED CELLULAR TERMINAL. DOC. NO: SS-10 3G-14 (Rev. 01) Page 1 of 20

SET-UP INSTRUCTIONS. How can the DB9000-TX be used as an Icecast Source Client, sending audio to DB9000-RX decoder used as an Icecast Source Server

AV-4000 GSM AV-4000 DVR

AUTOLOG GSM-PLC STEP BY STEP

KAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS MODEM TELEM-GSM/GPRS 3G. User manual

PJ2500LCD USER MANUAL VOLUME1. Manufactured by R.V.R ELETTRONICA S.p.A. Italy

Appendix) Specifications of Monitor & Control Rev. 4.0 July 13, 2016

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL

PWRMETER-D2. User Manual Volume 1. Manufactured by

HT-1A Dual Band CW QRP Transceiver. User Manual

Products no longer available

ATS Automatic transfer switches Advanced version

ELAD DUO-ART 60 HF/50MHz 60W amplifier USER MANUAL

Audio Interface Quick start guide

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

Aristel Networks Pty Ltd. All Round Cabling Solutions NEOS3003-3G01. Operating Manual * NEOS G01

T L Audio INDIGO SERIES. User Manual PA-2001 VALVE PRE-AMPLIFIER. Tony Larking Professional Sales Limited, Letchworth, England.

T L Audio INDIGO SERIES. User Manual C-2021 VALVE COMPRESSOR. Tony Larking Professional Sales Limited, Letchworth, England.

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015)

User Manual for VE GSM Modem

Prisma II Platform. Optoelectronics

Instruction Manual Model Block Translator

The UFC-6000 can measure the frequency of a signal from 1 to 6000 MHz. Mini-Circuits

R-1000 TELEMETRY RECEIVER OPERATING MANUAL. Look inside to learn about NEW FEATURES

Stereo encoder Pro 2. Features

ANT CNTR DC ALRM LNB RX DC ALRM +18V OFF

RTS ISDN 2002 System. Operator Manual Software Description

Audio Deck Manual. Euphonix Inc. 220 Portage Avenue Palo Alto, CA Tel: (650) Fax: (650) Web Page:

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO

TZW803+ 8x1 VGA/XGA & AUDIO SWITCHER. ELPRO Video Labs s.r.l. St.da della Pronda, 45/B Torino ITALY Tel Fax

RTU560 Connections and Settings DIN Rail RTU 560CIG10

Operation Manual GSM modem irz TG42-232

GosHawk II COMMUNICATIONS

Ku-Band Solid-State Power Amplifier

MODEL 801R REMOTE CONTROL MICROPHONE PREAMPLIFIER

Strain Gauge Converter

AMS x1 Video + Audio Passive Switcher. User Manual. I.R.T. Communications Pty Ltd Page 1 of 10 Revision 03

MAXPRO Next generation 20W FM exciter board

HydroLynx Systems, Inc. Model 50386D Decoder Instruction Manual

Conversion of Contact ID event codes sent by alarm control panel via GSM and PSTN channel to SMS messages

TELTONIKA ModemCOM (TMC-10x) User Manual V

L4561N Stereo Control. Installation manual.

Starlink 9003T1 T1/E1 Digital Transmission

LBI-38599F Maintenance Manual

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

CU 6005 DCS 6000 Medium Power Central Control Unit

1073N. Channel Amplifier. User Manual Issue 1.3

AMU1-CHD+MK2 AUDIO MONITORING UNIT

DATA LOGGER (Version V1.3)

The Packs Infotel. GSM Converter V2. Installation Manual V7

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

OnCell G3100 Series Quick Installation Guide

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

Bi-directional Power Sensor 2 Series

Model R5005. Instruction Manual. True RMS Industrial Multimeter. reedinstruments. www. com

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL

RF0250 RF1100 RF1200 RF1300 RF1600

Sensaphone SCADA 3000 APPLICATION SUPPORT BULLETIN Single-Frequency Radio

CAS SEC (Serial) Protocol for Mitsubishi UPS. Gateway

NEOS3000A GSM Least Cost Wireless Router

Modular Block Converter Systems

NETAFIM WILL NOT ACCEPT RESPONSIBILITY FOR DAMAGE RESULTING FROM THE USE OF NETAFIM'S PRODUCTS OR THE USE OF THIS MANUAL.

Multi-IQ. Firmware: RS232-Data Manager for UPS 4 x RS232 / 1 x LAN-Contacts flash upgradeable. User manual. (Serial Number / Seriennummer)

UC-2000 Installation Manual Unicorn Computers Technology Limited

USER MANUAL. SATEL i-link. I/O-converter. Version 1.4

ZLAN5443A. User Manual

The 2U package makes the unit suitable for using in workstations, storage systems, racks for industrial and many other applications.

AMPLIFIER PARALLEL INTERFACE SPECIFICATION

Bluetooth/RS-232 Enhanced Data Communication

NUG 2014 Mike Woods Head of Development

CONTENTS 1. SAFETY INFORMATION SPECIFICATION PARTS & CONTROLS General Specification Electrical Specification...

Cisco Prisma II Platform

SENECA s.r.l. Commercial

LineMaster 200. Continuous-line recorder. Parameter setting instructions 42/43-28 EN Rev. 03

NTI. KEEMUX Series. KEEMUX-P2 (2-Port PS/2 KVM Switch) INSTALLATION / USER GUIDE R NETWORK TECHNOLOGIES INCORPORATED

S-Band Redundant LNA Systems

GSM HOME SECURITY SYSTEM

SC32A Optically Isolated RS232 Interface

STD Simple Telemetry Application. Owner s Manual

INT-HD52 Quick Install Guide

DTP-30C/PCI, DTP-30C/PCI+ DTP-60C/PCI, DTP-60C/PCI+ DTP-120C/PCI, DTP-120C/PCI+

WI-I/O 9 Multi I/O Units

F5-45x3/85x3 10/100Mbps Ethernet to 4E1/8E1 Converter User Manual

SMARTLINE WIRELESS INTERFACE SYSTEM INSTALLATION MANUAL

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

i-7550 PROFIBUS to RS-232/422/485 Converter User's Manual High Quality, Industrial Data Acquisition, and Control Products

RT4F-48V/50A-WAC RECTIFIER

TS-ADA-029. Wireless Tone Generator. User's Manual / Installation Guide. Version 1.03

464kB SOLID STATE SWITCH SYSTEMS. 464kB SALIENT FEATURES SYSTEM OPERATION. 464kB DESCRIPTION

Amb-OS Media, LLC AMR-100I

FSK TX CELLULAR PLUS. Installation and Programming Guide. Tel:

ETHM-2. Ethernet Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

IMPORTANT SAFETY INSTRUCTIONS

AUD-220 Installation Guide

Transcription:

Additional Manual for TEX-LCD series and TEX-LIGHT series Manufactured by Italy

File Name: 03_TLC_ING_1.0.indd Version: 1.0 Date: 01/02/2008 Revision History Date Version Reason Editor 01/02/2008 1.0 Prima Edizione J. H. Berti /TLC - Additional Manual Version 1.0 Copyright 2008 R.V.R. Elettronica SpA Via del Fonditore 2/2c - 40138 - Bologna (Italia) Phone: +39 051 6010506 Fax: +39 051 6011104 Email: info@rvr.it Web: www.rvr.it All rights reserved Printed and bound in Italy. No part of this manual may be reproduced, memorized or transmitted in any form or by any means, electronic or mechanic, including photocopying, recording or by any information storage and retrieval system, without written permission of the copyright owner.

Table of Content 1. General Description 1 1.1 Remote alarm monitoring 1 1.2 Telemetry 3 1.3 Remote control 3 2. Remote Alarm Reporting Configuration 5 3. TEX-LCD/TLC External Description 9 3.1 Rear Panel TEX-LCD (2 HE) 9 3.2 Rear Panel TEX-LCD (3 HE) 11 /TLC User Manual Rev. 1.0-01/02/08 i

ii Rev. 1.0-01/02/08 This page was intentionally left blank User Manual

1. General Description /TLC The telemetry option, whether internal or external, supports connectivity to the whole range of units of RVR s TEX-LCD and TEX-LIGHT family of products. This section describes the features introduced with /TLC version (option with external telemetry without modem) and the necessary steps for their proper configuration. The telemetry option supports: Remote alarm reporting by sending SMS messages through a GSM modem or through a PSTN modem (dial-up) by sending an alarm message string to a connected PC. Telemetry, with all equipment parameters sent to the TELECON software through an RS232 connection. Remote controlling through an RS232 connection to the TELECON software or through certain predetermined SMS messages if an external GSM modem is connected. Telemetry on internet across 10Base-T LAN/Ethernet network through TCP-IP -INT/TEX external interface connection. 1.1 Remote alarm monitoring Alarm generation parameters are listed below: Exciter output power (forward power good PgD ); Reflected power at the exciter (reflected power good PgR ); Temperature state (OVER TEMPERATURE); Audio Signal Level; Mains voltage state (present or missing). Factory default settings are as follows: ALARM TIME THRESHOLD Forward Power (Fwd Pwr) 25 Sec. Power Good (PgD) Reflected Power (Rfl Pwr) 25 Sec. Power Good (PgR) Audio 325 Sec. 20 khz Over Temperature 25 Sec. 72 C Mains Power (Mains) 25 Sec. Table 1.1 An inhibit time (start time) after power-on is provided to ensure false alarm prevention. When this inhibit time times out, the thresholds of alarm generation parameters are checked and remote alarms are sent if needed. Alarm generation technique is outlined in the figure below; remote alarm delay, i.e. the amount of time the system waits before issuing a remote alarm after an alarm condition occurs is indicated in table 1.1. When appropriate, a new line is added to the alarm log stored in /TLC, up to six lines maximum. User Manual Rev. 1.0-01/02/08 1 / 12

Figure 1.1 The alarm log may be reviewed using the TELECON software or through SMS (see relevant section). WARNING: The mains alarm is triggered from the battery charger board; as a result, this board is required even when no batteries are installed. In the configuration without batteries, no alarm is generated; instead, an SMS message indicating a normal condition is sent upon next start-up. When any one of the parameters listed above changes state, a text message with the following information is sent via modem (if fitted): Station Name. Station ID. State of measurements. EX1. TLC ID:01-Station Name- Fwd Power OK- RFL Power OK- Over Temp OK- Audio OK- Mains OK- EX2. TLC ID:01-Station Name- Alarm Fwd Power- RFL Power OK- Over Temp OK- Alarm Audio - Alarm Mains - 2 / 12 Rev. 1.0-01/02/08 User Manual

1.2 Telemetry Equipment telemetry consists in the remote monitoring of all operating parameters and can only be achieved through serial cable or modem connection to the TELECON software. 1.3 Remote control When the exciter is connected to the internal telemetry unit, it can be controlled from a PC. Fig.1.2: Example of Modem-to-PC connection The TELECON software establishes connection with the station and enables the following remote operations: alarm reset, transmitter power on/power off, power supply reduction, dummy load testing, etc., data evaluation to locate possible faults, identification of parts required for repair. An alternative remote controlling option uses SMS messaging through a common GSM phone (if connected with an external GSM modem), in which case the equipment will respond as indicated in table 1.2. Before querying the system using SMS messages, establish a connection using the TELECON software and set the provider service centre number and the telephone numbers authorised to send these commands to the devices. User Manual Rev. 1.0-01/02/08 3 / 12

The internal and external telemetry options support the following commands: Command Response Description Station: station name - ID: station identifier - INFO FWD: absolute value - Transmitter status RFL: absolute value - Temp: absolute value - information TX On (or TX Off)- Alarm Present / Alarm Absent INFO1 TXON TXOFF ALARM RESET RESMOD -- none -- Alarm SMS message Station: station name - ID: station identifier - TX is On - Station: station name - ID: station identifier - TX is Off - Station: station name - ID: station identifier - Alarm: Alarm log Station: station name - ID: station identifier - ALARM RESET OK- Table 1.2 Forces the transmission of an alarm SMS msg Transmitter power-on Transmitter power-off Alarm log Clear Alarm Log Resets and re-initialises modem Note: Response time to SMS commands may vary with different GSM network providers; as a general rule, response time should not exceed 7-10 minutes maximum. 4 / 12 Rev. 1.0-01/02/08 User Manual

2. Remote Alarm Reporting Configuration Firstly, you will have to set certain parameters in the (internal or external) telemetry option using the TELECON software. Connect the PC serial port COM to the RS232 connector on the rear panel of the /TLC option using a standard Male DB9 - Female DB9 serial cable. Fig.2.3: Example of connection between TEX-LCD unit with /TLC option and PC When using the TELECON software for the first time, select the station and then enter: COM port used, Baud rate (set to 9600), type of connection (set to direct, via cable). When you have entered the correct data, click the Start button to confirm and the TELECON main screen appears, as shown in the figure: User Manual Rev. 1.0-01/02/08 5 / 12

Use this screen to change Start time. To edit this parameter, click the TStart box with the left mouse button (default setting is 300sec., the equivalent of 5 min.); this opens a window where you can change the setting. Press Enter to confirm. Double click the green label in the top left corner of the TELECON screen and select Eeprom (as shown in the figure below). In the open menu, press this key to view station parameters. Select the General data category and set the 5 parameters: STATION ID: Station identifier; STATION NAME: (max 18 characters); 6 / 12 Rev. 1.0-01/02/08 User Manual

DIAL STRING: required setting for a GSM modem is ATDT; NUMBER OF RETRY: number of alarm transmission repetitions; SERVICE CENTER NUMBER: number of GSM provider service centre for SMS transmission and reception; place country code before number. Example with Italian service providers: TIM: +393359609600 VODAFONE: +393492000200 WIND: +393205858500 Now select the Telephone data category and set the following: User Manual Rev. 1.0-01/02/08 7 / 12

PHONE NUMBER: GSM phone numbers recognised by the station to which you want the alarms sent; SMS: select YES to enable transmission of SMS commands to system; ACS: select YES to enable SMS reception. Note: For correct transmission, place country code (+XX) before set numbers (Use +39 for Italy). When all parameters are set, press this key and the internal or external Telemetry option will store the information. When finished, click Exit to exit the remote station programming window. Back into TELECON standard interface, click the General measurement selection button to set thresholds and operation times for the various alarms according to the principles outlined in Section Alarm Management. Note: When setting alarm thresholds, allow a margin of some percent points with respect to normal operation parameters. 8 / 12 Rev. 1.0-01/02/08 User Manual

3. TEX-LCD/TLC External Description /TLC This section describes the components found on the rear panel of the internal telemetry option \TLC. 3.1 Rear Panel TEX-LCD (2 HE) figure 3.1 [1] PLUG VDE plug for mains voltage. [2] VENTOLA Fan for the forced ventilation of the exciter. [3] R.F. OUTPUT RF output connector, N-type, 50 Ω [4] 24 VDC IN- External 24Vdc supply input. Negative (black). [5] 24 VDC IN- External 24Vdc supply input. Positive (red). [6] INTERLOCK OUT Interlock output BNC connector: when the transmitter goes into stand-by mode, the (normally floating) central conductor is switched to ground. [7] FWD EXT. AGC Trimmer to set output power limitation according to FWD fold input. [8] RFL EXT. AGC Trimmer to set output power limitation according to RFL fold input. [9] REMOTE DB15 telemetry connector. [10] GSM ANT TEX-LCD: Not present. TEX-LCD/TLM: SMA connector for GSM. TEX-LCD/TLC: Not present. [11] PHASE ADJ Pilot tone phase trimmer. [12] MODE/MPX IMP Dip-switch used to select transmission mode (STEREO or MONO) and MPX input impedance (50 Ω or 10 kω). [13] SCA/RDS BNC connector for unbalanced SCA1/RDS input. [14] MPX Unbalanced MPX input BNC connector. [15] MPX ADJ Trimmer for MPX input level adjustment. [16] SCA/RDS ADJ Trimmer for SCA1/RDS input level adjustment. [17] RIGHT ADJ Trimmer di regolazione dei livelli dell ingresso destro [18] RIGHT Right audio channel input XLR connector. [19] FUSE BLOCK Fuse carrier.use a screwdriver to access the fuse. Contains the general protection fuse. [20] R.F. TEST Output with level 13 dbm lower than output power level, suitable for modulation monitoring. Not suitable for spectrum analysis. [21] MODEM TEX-LCD: Not present TEX-LCD/TLM: DB9 Connettor for GSM modem connection. TEX-LCD/TLC: Power supply output for external modem or TCP/IP-INT-TEX interface. User Manual Rev. 1.0-01/02/08 9 / 12

[22] I 2 C BUS TEX-LCD: Non present TEX-LCD/TLM o /TLC: DB9 connector for I 2 C bus network. Usually not used, or used for special operations depends on customer requirements. [23] RS232 TEX-LCD: Not present. TEX-LCD/TLM o /TLC: DB9 connector for serial, direct or modem communications. [24] SERVICE DB9 connector for factory setting. [25] EXT REF 10MHz BNC connector for synchronism signal for external devices. [26] PREEMPHASIS Preemphasis dip-switch, provides two settings: 50 or 75 μs. Preemphasis affects the right and left inputs in stereo mode and the mono input. MPX inputs are not affected by preemphasis setting. [27] 19 khz PILOT OUT Tone output BNC connector, may be used to synchronise external devices such as RDS coders. [28] SCA2 BNC connector for unbalanced SCA2 input. [29] SCA2 ADJ Trimmer for SCA2 input level adjustment. [30] LEFT-MONO ADJ Trimmer di regolazione dei livelli dell ingresso sinistro-mono [31] LEFT-MONO Left-mono audio channel input XLR connector. [32] IMPEDANCE Dip-switch used to select balanced audio input impedance (600 Ω or 10 kω). 10 / 12 Rev. 1.0-01/02/08 User Manual

3.2 Rear Panel TEX-LCD (3 HE) Figura 6.2 [1] R.F. TEST Output with level -60 db lower than output power level, suitable for modulation monitoring. Not suitable for spectrum analysis. [2] GSM SLOT-IN Reserved for future implementations. [3] GSM ANT TEX-LCD: Not present TEX-LCD/TLM: SMA connector for GSM TEX-LCD/TLC: Not present [4] AIR FLOW Air grille. [5] 10MHz Reserved for future implementations. [6] PHASE ADJ Pilot tone phase trimmer. [7] 19 khz PILOT OUT Tone output BNC connector, may be used to synchronise external devices such as RDS coders. [8] PREEMPHASIS Preemphasis dip-switch, provides two settings: 50 or 75 μs. Preemphasis affects the right and left inputs in stereo mode and the mono input. MPX inputs are not affected by preemphasis setting. [9] MODE/MPX IMP Dip-switch used to select transmission mode (STEREO or MONO) and MPX input impedance (50 Ω or 10 kω). [10] SCA2 BNC connector for SCA2 input. [11] SCA1 BNC connector for SCA1 input. [12] MPX Unbalanced MPX input BNC connector. [13] SCA2 ADJ Trimmer for SCA2 input level adjustment. [14] MPX ADJ Trimmer for MPX input level adjustment. [15] SCA1 ADJ Trimmer for SCA1 input level adjustment. [16] RIGHT ADJ Trimmer for right input level adjustment. [17] RIGHT Right audio channel input XLR connector. [18] IMPEDANCE Dip-switch used to select balanced audio input impedance (600 Ω or 10 kω). [19] MAINS Connectors for 115-230 V 50-60 Hz mains power supply. [20] FUSE 1 Mains power supply fuse [21] R.F. OUTPUT RF output connector, N-type for TEX500-LCD and 7/16 for TEX1000LIGHT, TEX1000-LCD and TEX1300-LCD. [22] INTERLOCK OUT Interlock output BNC connector: when the transmitter goes into stand-by mode, the (normally floating) central conductor is switched to ground. [23] SERVICE DB9 connector for factory setting. [24] INTERLOCK IN Interlock input BNC connector: the exciter is forced in standby mode when the inner conductor is grounded. [25] MODEM TEX-LCD: Not present TEX-LCD/TLM: DB9 Connettor for GSM modem connection. TEX-LCD/TLC: Power supply output for external modem or TCP/IP-INT-TEX interface. User Manual Rev. 1.0-01/02/08 11 / 12

[26] FWD EXT. AGC Trimmer to set output power limitation according to FWD fold input. [27] RFL EXT. AGC Trimmer to set output power limitation according to RFL fold input. [28] REMOTE DB15 telemetry connector. [29] RS232 TEX-LCD: Not present TEX-LCD/TLM o /TLC: DB9 connector for serial, direct or modem communications. [30] SERVICE VOLTAGE SEL. 115-230V mains voltage selector. [31] I 2 C BUS TEX-LCD: Non present TEX-LCD/TLM o /TLC: DB9 connector for I 2 C bus network. Usually not used, or used for special operations depends on customer requirements. [32] SERVICE FUSE Service fuse. [33] LEFT ADJ Trimmer for left input level adjustment. [34] LEFT Left audio channel input XLR connector. [35] FUSE 2 Mains power supply fuse. 12 / 12 Rev. 1.0-01/02/08 User Manual