RMx621 /FML621. Appendix to the operating manual

Similar documents
RMx621. Appendix to the operating manual

Appendix to the Operating Instructions RMx621 with ModBus Interface V Connection to ModBus-IDA System

BA00216R/09/EN/ MS Word

Operating Instructions RMx621

Additional instructions Memograph M, RSG45 Advanced Data Manager

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO

PROFIBUS DP/CAN Gateway PCA-100. User Manual

Operation Manual Profibus DP -Display HE 5120 P with digital I/O's

SCHMIDT Sensor interface PROFIBUS Instructions for use

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet

Anybus X-gateway. PROFIBUS Master Interface NETWORK GUIDE SCM EN 1.0 ENGLISH

H 250 with PROFIBUS-PA signal converter ESK3-PA

i-7550 PROFIBUS to RS-232/422/485 Converter User's Manual High Quality, Industrial Data Acquisition, and Control Products

UFC 400 Supplementary instructions

FC8x. Profibus Communication

VersaMax IP Input Module

Modbus/ PROFIBUS DP Gateway PM-160

DVPPF02-SL PROFIBUS DP Slave Communication Module

L5353 Profibus-DP Communications Interface

PCM-Decoder HG A

Operation manual. HDOM-Profibus-V0. More options please visit;

Date Revision Change(s) First version

CAN-Bridge. CAN Communications Module for CAN 2.0 A/B, CAN Layer AA01. Manual. Version 1/ from HW 1 & FW 1.00

Expansion Module HZS 541-1S

Device manual Profibus encoder. RM30xx RN30xx /00 06/2013

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Date Revision Change(s) 29/07/ First version

Date Revision Change(s) First version Firmware Update 1.5

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Anybus Communicator STARTUP GUIDE. IIoT. SP en-us ENGLISH

Murdoch University Engineering Thesis. Appendix XII. Profibus PA System Configuration Instructions

Catalog 1 Product Overview General Important User Information About the Gateway Function Features Tec

CAN 300 PRO, Communication Module

Supplementary instructions Sigma X control type with PROFIBUS

ST (6ES7132-6FD00-0BB1)

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance.

PROFI-5053 PROFIBUS Remote I/O Module Quick Start Guide

SMART RELAY SRW 01 V4.0X

LB/FB8X09* / LB/FB8X05*

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

Technical Manual. HA Issue 4. Copyright Parker SSD Drives, Inc 2008

Temposonics. R-Series Profibus. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm

RS485 MODBUS Module 6RO

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

An optional analog input module, Order no connected to a 6-pole system connector adds four more analog sensors to the device.

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

I/O module (Expansion module)

EL731 PROFIBUS INTERFACE

IO1000. Type designation. Product description I/O module INSTALLATION MANUAL. Catalog no. from software version Document no I/O module 1.

The output variables can be force-controlled from a coordinating control system.

CVIC II - CVIL II - CVIR II - MULTICVIL II - Memory Mapping - Manual

While every effort was made to verify the following information, no warranty of accuracy or usability is expressed or implied.

GW-7553-CPM PROFIBUS/CANopen GATEWAY. User's Manual

PA ROUTERS. The following criteria can be applied when choosing the network transition:

Date Revision Change(s) 10/10/ First version

VPGate Manual PROFIBUS to serial

ANTAL ELECTRONIC Field Bus and Communication Technology. Manual PDP2CL2. Version 3.08

IL CAN BK-TC-PAC. Extract from the online catalog. Order No.:

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

Universal Serial/PROFIBUS DP Gateway GT200-DP-RS User Manual V6.1 SST Automation

Motors Automation Energy Transmission & Distribution Coatings. Profibus DP SRW 01. User s Manual

RS485 MODBUS Module 8AO

BB2 Profibus DP option

Siemens Drives & PLCs

Serial PROFIBUS Interface

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

1. CP430, CP470, CP474, CP770 and CP774

IL CAN BK-TC-PAC. Extract from the online catalog. Order No.:

IndraControl S67. Fieldbus coupler PROFINET

Installation and Operating Instructions. webremote

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29

Operator Manual for Profibus

PROFIBUS Slave. X-gateway Interface Addendum. Doc: HMSI , Rev: Connecting Devices TM

Gateway 1400 Reference Manual

User s Manual DX1000/DX1000N/DX2000 PROFIBUS-DP (/CP1) Communication Interface

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

GRASSO SYSTEM CONTROL

AnyBus-PCI Profibus DPV1 Master

FIELDBUS TECHNOLOGY ETHERNET- PROFIBUS- INTERFACE PB-XEPI F1144/ 03 INSTALLATION MANUAL

PCAN-Router FD Universal, programmable Converter for CAN FD and CAN. User Manual. Document version ( )

mipick Pick-by-Light System

General information. Supply voltage

User Manual. Profibus DP Master to Crowcon Vortex 12 Ch. Generic. Formac Electronics Ltd. T:+44 (0) Oxford House F:+44 (0)

Switched Mode Power Supply Operating manual PAP800

PAC BI-DP BIM and 8701-CA-BI Carrier

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

PROFIBUS OPTION CARD FOR VLINX FIELDBUS GATEWAY

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

This manual may not be reproduced in whole or in part by any means, without written permission of Accuenergy.

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

PCAN-MicroMod Digital 1 & 2 Application-specific PCAN-MicroMod Motherboard. User Manual V1.10.0

CP ADVANCED. Function

IQ SENSOR NET MIQ/(A-)MOD

MU110-6U. Analog output module 6 channel. User guide

DN-DP PROFIBUS-DP / DeviceNet-Gateway

RS485 MODBUS Module 8I8O

Additional instructions Videographic recorder LINAX DR3000. PROFINET Device

User Manual AnyBus Communicator for Profibus

Transcription:

Appendix to the operating manual RMx621 /FML621 DP-slave module ( PROFIBUS-coupler ) from V2.01.00 Connecting the RMx621 /FML621 to PROFIBUS DP via the RS485 serial interface using the external module (HMS AnyBus Communicator for PROFIBUS) BA154R/09/en/08.09 51006429

Table of contents Table of contents 1 General........................ 4 1.1 Transport damage.......................... 4 1.2 Delivery................................. 4 1.3 Notes on safety conventions and icons........... 4 1.4 Abbreviations/terminology explanation.......... 4 2 Installation...................... 5 2.1 Function description........................ 5 2.2 Conditions............................... 5 2.3 Connections and operating elements............ 6 2.4 Installation on DIN rail...................... 6 2.5 Connections and terminal layout............... 7 2.6 PROFIBUS-DP terminal layout................. 8 2.7 Bus address set-up.......................... 8 3 Commissioning................... 9 3.1 Set-up for the RMx621 / FML621.............. 9 3.2 Set-up for the PROFIBUS-coupler.............. 9 3.3 Status display............................ 10 4 Data transmission................ 11 4.1 General................................. 11 4.2 Usable data construction.................... 11 4.3 Units for the transmission of process values...... 12 5 Installation in a Simatic S7......... 13 5.1 Network overview......................... 13 5.2 GSD file EH_x153F.gsd..................... 13 5.3 Projecting the RMx621 / FML621 as a slave..... 14 6 Technical data.................. 15 3

General 1 General 1.1 Transport damage Please inform both your supplier and transport company. 1.2 Delivery These operating instructions The DP-slave module HMS AnyBus communicator for PROFIBUS Serial connection cable for the RMx621 / FML621 CD-ROM containing the GSD-file and Bitmaps Should anything be missing please inform your supplier immediately! " Caution! # Warning!! Note! 1.3 Notes on safety conventions and icons The safety instructions in these Operating Instructions are labelled with the following safety icons and symbols: This symbol draws attention to activities or procedures that can lead to defective operation or to destruction of the device if not carried out properly. This symbol draws attention to activities or procedures that can lead to injuries to persons, to a safety risk or to destruction of the device if not carried out properly. This symbol draws attention to activities or procedures that have an indirect effect on operation, or can trigger an unforeseen device reaction if not carried out properly. 1.4 Abbreviations/terminology explanation PROFIBUS-coupler In the following text the external DP-slave module HMS AnyBus communicator for PROFIBUS will be known as the PROFIBUS-coupler. PROFIBUS-master All units such as DCS, PLC, PC-plug in boards, that operate as a PROFIBUS-DP master, will be known as the PROFIBUS-master. 4

Installation 2 Installation 2.1 Function description The Profibus-DP connection is made using an external PROFIBUS-coupler. This module is connected to the RMx621 / FML621using the RS485-serial interface (RxTx1). The PROFIBUS-coupler operates as a master in the direction of the RMx621 / FML621 and reads out and the process values in every second and then places these into its buffer memory. In the direction of the Profibus DP system the PROFIBUS-coupler operates with the function of a DP-slave for cyclic data transfer and on request makes the buffer stored process values available to the Bus. Architecture, see the diagram below. G09-RMC621ZZ-15-10-xx-de-004 2.2 Requirements This option is available in the RMC621, RMM621 and FML621 from Firmware-Version V 1.00.00 and in the RMS621 from Firmware-Version V 2.00.04. 5

Installation 2.3 Connections and operating elements G09-RMx621ZZ-04-10-xx-de-001 2.4 Installation on DIN rail A - Snap ON B - Snap OFF G09-RMx621xx-17-10-06-xx-001 6

Installation 2.5 Connections and terminal layout Connecting the RMx621 / FML621 with the PROFIBUS-coupler G09-RMx621ZZ-04-10-xx-de-004! Note! The color indication is valid for the cable supplied. PROFIBUS DP connections (to the PROFIBUS-coupler) For connection to the PROFIBUS we recommend the use of an EN 50170 compliant 9-pole Sub-D plug with an integrated Bus termination resistance. G09-RMx621ZZ-04-10-xx-xx-003 7

Installation 2.6 PROFIBUS-DP terminal layout Pin No. Signal Description Housing Screen Functional ground 3 B-cable RxTx (+) 5 GND Operational ground 6 VP Supply for the termination resistors 8 A-cable RxTx (-) 2.7 Bus address set-up The two selector switches used for the set up of the Bus address are available after carefully opening the front cover. G09-RMx621xx-19-10-00-xx-000! Note! Using these selector switches Bus addresses within a range of 00 to 99 can freely set up. Only use valid addresses. 8

Commissioning 3 Commissioning 3.1 Set-up for the RMx621 / FML621 In the main menu Communication É RS485(1) of the RMx621/ FML621 the parameters for the RS485 (1) interface should be set up as Unit address to 1 and Baudrate to 38400. G09-RMx621xx-19-10-00-de-001 How many process values are to be transmitted can be set up in the main menu Communication É PROFIBUS É Number, whereby the maximum number is limited to 48. In further steps each offset address can be allocated to the required process value using selection lists. G09-RMx621xx-19-10-00-de-002! Note! For simple and easy further evaluation of the process values the list of offset addresses can be printed out using the ReadWin 2000 operating software.. When specifying the process values displayed with PROFIBUS DP, please note that the same process value can be set to more than one address. If a PROFIBUS coupler labeled "Rev.B" is used, device software version V03.02.03 should be used for RMC621 and device software version V02.02.16 for RMS621. PROFIBUS couplers labeled "Rev.B" have a fixed baudrate of 38,400 baud. Set the baudrate to 57,600 for devices before "Rev.B". 3.2 Set-up for the PROFIBUS-coupler The PROFIBUS-coupler is already set-up by the factory. Apart from the Bus addresses no further setup is required. A match to the Profibus-DP data transmission rate is done automatically. 9

Commissioning 3.3 Status display The 6 LEDs display the actual unit status and data exchange. G09-RMx621xx-19-10-00-xx-003 LED Description Display Status Actions 1 ONLINE Green Off 2 OFFLINE Red Off 3 NOT USED PROFIBUS-coupler ready for operation PROFIBUS-coupler not ready for operation Check connector Check Profibus network 4 FIELDBUS DIAG Red flashing Configuration error Check PLC set-up Off No Bus error detected 5 SUBNET STATUS Green Data exchange running Green flashing Data exchange halted Check connection between Red Data exchange not possible PROFIBUS-coupler and the RMx621 / FML621; Check communication parameter in the RMx621 / FML621 Off Power supply failure Check the power supply 6 DEVICE STATUS Green Initialisation running Green flashing Red/Green flashing PROFIBUS-coupler operating Faulty set-up Unit defective Off Power supply failure Check the power supply 10

Data transmission 4 Data transmission 4.1 General In the RMx621 / FML621 various process values are calculated dependent on the preset applications and are then made available for read out. In addition to the calculated values the input values can also be read out from the RMx621 / FML621. 4.2 Usable data construction Each process value takes up 5 Bytes in the process picture. The first 4 Bytes are compliant to an IEEE-754 (MSB first) 32-Bit floating point number 32-Bit floating point number (IEEE-754) Octet 8 7 6 5 4 3 2 1 1 VZ (E) 2 7 (E) 2 6 (E) 2 1 2 (E) 2 0 (M) 2-1 (M) 2-2 (M) 2-7 3 (M) 2-8 (M) 2-15 4 (M) 2-16 (M) 2-23 VZ = 0: Positive number VZ = 1: Negative number Number = -1 VZ (1 + M) 2 E 127 E = Exponent; M = Mantissa Example: 40 F0 00 00 h = 0100 0000 1111 0000 0000 0000 0000 0000 b Value = -1 0 2 129 127 (1 + 2 1 + 2-2 + 2-3 ) = 1 2 2 (1 + 0.5 + 0.25 + 0.125) = 1 4 1.875 = 7.5 The last Byte transmits the value s status: 80h = Valid value 81h = Valid value with alarm set point violation (linked to relay output) 10h = Faulty value (e.g. Cable open circuit) 00h = No value available (e.g. due to communication error in the sub-net)! Note! For calculated values (e.g. mass flow), the alarm condition of all the inputs deployed and the application are checked. If a "fault" is displayed for one of these variables, the calculated value is given the status "10h", i.e. invalid value. Example: Temp1 cable open circuit; Alarm type: fault => calculated mass flow (10h) Temp1 cable open circuit; Alarm type: notice => calculated mass flow (80h) The number of process values transmitted is laid down in the energy manager set-up, see Section 3.1. The minimum number is 1 process value (5 Byte), the maximum is 48 process values (240 Byte). 11

Data transmission 4.3 Units for the transmission of process values The units for the transmission of process values are specified in the Setup menu of the RMx621 / FML621. Choose Display units in order to use the units configured for display also for the transmission via PROFIBUS DP. Choose Default units to use the following standard units for the transmission: Volume flow l/s Temperature C Pressure Heat quantity Heat flow (power) Mass flow Corrected volume Flow sum Mass sum Corrected flow sum bar kj kw (kj/s) kg/s (N)l/s l kg (N)l Density kg/m 3 Enthalpy kj/kg 12

Installation in a Simatic S7 5 Installation in a Simatic S7 5.1 Network overview G09-RMx621xx-02-xx-xx-de-000 5.2 GSD file EH_x153F.gsd Either install using Extras/install new GSD or copy the GSD- and BMP- files into the required directory of the Software STEP 7. e.g.: c:\...\siemens\step7\s7data\gsd c:\...\ Siemens\Step7\S7data\NSBMP The GSD-file is located on the Readwin 2000 CD-ROM supplied, in the directory \GSD\RMS621 RMC621 RMM621\ Example for Energy Manager G09-RMx621xx-20-10-xx-xx-000 13

Installation in a Simatic S7 5.3 Projecting the RMx621 / FML621 as a slave Hardware configuration (e.g. Energy Manager RMS/RMC621): Pull out the Energymanager RMx621 unit from the hardware catalogue -> PROFIBUS DP -> further field units -> General in the PROFIBUS DP network Set the user addresses G09-RMx621xx-02-xx-xx-de-001 The GSD-File has two modules defined: Input (SPS) RMx621 É PROFIBUS master Config string AI: 5 bytes One numeric value + status 0x40, 0x84 4 AI: 20 bytes Four numeric values with status each 0x40, 0x93! Note! Assign as many modules to the individual slots as is necessary for the number of process values to match the number set in the energy manager. A maximum of 12 modules can be used here. The "4 AI: 20 Byte" module can be used instead of four individual "AI: 5 Byte" modules. The projected unit address must correspond with the actual set up hardware addresses. The address range of the process values must be uninterrupted. 14

Technical data 6 Technical data Dimensions: 120mm x 75mm x 27mm (height, depth, width) Power supply: 24V DC +/-10% Power consumption: PROFIBUS-DP Baud rate: Typ. 120mA, Max. 280mA 9.600, 19.200, 45.450, 93.750, 187.500, 500.000, 1.5M, 3M, 6M, 12M RS485 interface parameters: Baud rate 38400, 8 data bits, 1 stop bit, unit address 01 Ambient temperature: +5... +55 C Storage temperature: -55... +85 C Air humidity: 5.. 95%, no condensation Ingress protection: IP 20 Ground cable connection: Approvals: Grounded internally via the DIN rail UL - E214107 15

BA154R/09/en/08.09 51006429 FM+SGML6.0 ProMoDo www.endress.com/worldwide