Manual. Decentralized Drive Control MOVIFIT FDC-SNI Connection to PROFIBUS/DeviceNet with UFF41B Fieldbus Gateway

Similar documents
Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVIFIT SNI UFF41B/UFR41B Fieldbus Gateway for MOVIGEAR SNI

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVIFIT SNI Fieldbus Gateway UFF41B for MOVIGEAR SNI

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. CCU Universal Module Application Module

Addendum to the Operating Instructions

Addendum to the Operating Instructions

Addendum to the Manual

Drive Technology \ Drive Automation \ System Integration \ Services. MOVITOOLS MotionStudio. Manual. Edition 06/ / EN

* _1118* Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Interface Adapter USM21A

Manual. Fieldbus Gateway UFF41B DeviceNet and PROFIBUS DP. Edition 02/ / EN

Drive Technology \ Drive Automation \ System Integration \ Services. Quick Start Guide. MOVIMOT MM..D With DRS/DRE/DRP AC Motor

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Electronic Motor DRC Functional Safety

* _1216* Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVIPRO with EtherNet/IP or Modbus/TCP Fieldbus Interface

Addendum to the System Manual. MOVIGEAR SNI Expanded Parameter Setting and Diagnostics with MOVITOOLS MotionStudio. Edition 01/ / EN

Revision to Manual

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVITRAC MC07B Functional Safety

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVITRAC B Simple Positioning Application Module

Manual. Fieldbus Interface DFE33B EtherNet/IP and Modbus/TCP. Edition 10/ / EN

Revision. Decentralized Drive and Application Control MOVIPRO ADC with PROFINET interface * _1017*

Manual. Controller DHE/DHF/DHR21B (standard) and DHE/DHF/DHR41B (advanced) * _0816*

Revision. MOVIPRO with EtherNet/IP or Modbus TCP Fieldbus Interface * _1017*

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVITRAC MC07B Functional Safety

* _1017* Drive Technology \ Drive Automation \ System Integration \ Services. Revision. MOVIPRO SDC With PROFINET Interface

* _1216* Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Electronic Motor DRC..

* _0318* Drive Technology \ Drive Automation \ System Integration \ Services. Manual. DFS21B PROFINET IO Fieldbus Interface with PROFIsafe

Installation Instructions

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVITRAC B Simple Positioning Application Module

Manual. MultiMotion / MultiMotion Light Technology Module Kinematics * _0714*

Manual. Decentralized Extra-Low Voltage Servo Drive CMP ELVCD Functional Safety * _0717*

* _0516* Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVI-C CONTROLLER power UHX85A and power eco UHX84A

Manual. MOVI-PLC advanced DHE41B/DHF41B/DHR41B Controller. Edition 04/ / EN

* _0815* Drive Technology \ Drive Automation \ System Integration \ Services. Manual. UHX71B Controller (Performance Class power)

Manual. Fieldbus Interface DFP21B PROFIBUS DP-V1. Edition 07/2006 FA / EN

Manual. Controllers DHE21B / DHF21B / DHR21B (standard) DHE41B / DHF41B / DHR41B (advanced)

Manual. MOVIDRIVE MDX60B / 61B Crane Control Application. Edition 01/ / EN

Manual. DFS21B PROFINET IO Fieldbus Interface with PROFIsafe (Safe Stop) Edition 10/ / EN

Installation Instructions

Revision to the Operating Instructions

Field Integrated Technology MOVIFIT. Innovative Decentralized Drive Systems

Manual. Libraries MPLCTec..._MDX, MPLCTecVirtualEncoder for MOVI-PLC. Edition 07/ / EN

Operating Instructions MOVISAFE UCS.B Safety Modules

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Communication Interface FSE24B EtherCAT For MOVITRAC B

Manual. Fieldbus Interface DFS11B PROFIBUS DP-V1 with PROFIsafe. Edition 09/ / EN

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Communication Interface FSE24B EtherCAT for MOVITRAC B

DeviceNet Expansion Board

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVIPRO -SDC With EtherNet/IP and Modbus/TCP Interface

* _0718* Drive Technology \ Drive Automation \ System Integration \ Services. Revision. UHX71B Controller (Power Performance Class)

Manual. MOVIFIT Function Level "Technology" Edition 08/2006 FC / EN

Manual. DFE32B PROFINET IO Fieldbus Interface. Edition 09/ / EN

Industrial Controls. Motor management and control devices SIMOCODE pro. Introduction 1. Configuring a reversing starter. List of abbreviations

Manual. MOVITRAC LTE-B+/LTP-B Accessories Keypads, Parameter Module, Cable Sets * _0618*

Revision. Drive System for Decentralized Installation Fieldbus Interfaces, Field Distributors * _0717*

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVIPRO SDC with DeviceNet Interface

Profibus DP Expansion Board

Manual. Configuration and Diagnostics Tool MOVIVISION Version Edition 07/2005 FE / EN

Drive Technology \ Drive Automation \ System Integration \ Services. MPLCTec.._MX Libraries. Manual. Edition 04/ / EN

SCHMIDT Sensor interface PROFIBUS Instructions for use

User Manual Revision English

Operating Instructions

Operating Instructions

Manual. MOVIAXIS MX Multi-Axis Servo Inverter Virtual Encoder Technology Function. Edition 05/ / EN

Date Revision Change(s) 29/07/ First version

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

AS-i Safety Relay Output Module with Diagnostic Slave

Original operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016

1 How to Read these Operating Instructions 3. 3 Introduction to MCF 106 A/ B in C Option Adaptor 7

Manual. MOVIMOT MM..D Functional Safety (including field distributor) * _0516*

Operating Instructions

Manual. MOVIFIT Function Level "Classic" Edition 06/2006 FC / EN

Operating instructions

Manual. MOVIFIT Function Level "System" Edition 06/2006 FC / EN

Operating Instructions

Operating instructions RFID evaluation unit DTE / / 2016

FACTORY AUTOMATION. MANUAL Absolute Rotary Encoder with PROFIBUS Interface

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Operating Instructions

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Data Matrix Positioning System PCV80A-F200-R4-V19-SEW

Operating instructions IO-Link master CabinetLine AL19xx

Serial PROFIBUS Interface

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVIDRIVE MDX61B DFS22B Fieldbus Interface PROFINET IO with PROFIsafe

MOVIDRIVE Drive Inverters

User manual BLCDN-8M12LT-8XSG-PD-8XSGPD

FIELDBUS TECHNOLOGY ETHERNET- PROFIBUS- INTERFACE PB-XEPI F1144/ 03 INSTALLATION MANUAL

System Manual DOP11B Operator Terminals

Manual. MOVIAXIS MX Fieldbus Interface XFP11A PROFIBUS DP. Edition 04/2006 FB / EN

User Manual BLCDP-2M12MT-2RFID-S

* _0314* Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Com User Task for MOVISAFE HM31 (version PFF-HM31A)

SMVector Additional I/O Module Installation and Operation Manual

Operating instructions. Switching amplifier DN0210 DN / / 2015

Content. Sontheim Industrie Elektronik GmbH Page 2 of 15 07/2016 Installation instructions Version 1.2

Operating Instructions

Operating Instructions MOVITRAC LTE-B

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

Installation Manual TH LINK PROFINET. Version: EN Copyright 2014 Softing Industrial Automation GmbH

* _0614* Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Data Matrix Positioning System PCV..

Revision. Decentralized Drive Systems MOVIMOT MM..D with AS-Interface * _0817*

UFD11A DeviceNet Fieldbus Interface

AS-i Safety Relay Output Module with Diagnostic Slave

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

MOVIDRIVE MDX61B INTERBUS DFI11B Fieldbus Interface

Transcription:

Drive Technology \ Drive Automation \ System Integration \ Services Manual Decentralized Drive Control MOVIFIT FDC-SNI Connection to PROFIBUS/DeviceNet with UFF4B Fieldbus Gateway Edition 0/0 950 / EN

SEW-EURODRIVE Driving the world

Contents Contents General Information... 4. How to use this documentation... 4. Structure of the safety notes... 4.. Meaning of the signal words... 4.. Structure of the section-related safety notes... 4.. Structure of the embedded safety notes... 4. Right to claim under warranty... 5.4 Exclusion of liability... 5.5 Other applicable documentation... 5 Safety Notes... 6. General information... 6. Target group... 7. Designated use... 8.4 Bus systems... 8 System Description... 9. System structure... 9. Operating principle... 0. Scope of delivery... 0 4 Installation and Startup... 4. Requirements... 4. Voltage supply... 4. Settings of the fieldbus gateway... 4.4 Fieldbus installation... 4.5 Controller settings... 4.6 Installation and startup of slave units... 4 4.7 Starting up the controller and the PLC... 4 5 Diagnostics... 5 5. UFF4B status display... 5 Index... 6 Manual Connecting MOVIFIT FDC-SNI to PROFIBUS/DeviceNet

General Information How to use this documentation Connecting MOVIFIT Æ FDC-SNI to PROFIBUS/DeviceNet General Information. How to use this documentation The documentation is part of the product and contains important information. The documentation is for everyone who works with this product. The documentation must be accessible and legible. Make sure that persons responsible for the system and its operation, as well as persons who work independently with the software and the connected devices from SEW-EURODRIVE, have read through the documentation carefully and understood it. If you are unclear about any of the information in this documentation, or if you require further information, contact SEW- EURODRIVE.. Structure of the safety notes.. Meaning of the signal words The following table shows the grading and meaning of the signal words for safety notes, notes on potential risks of damage to property, and other notes. Signal word Meaning Consequences if disregarded DANGER Imminent danger Severe or fatal injuries WARNING Possible dangerous situation Severe or fatal injuries CAUTION Possible dangerous situation Minor injuries NOTICE Possible damage to property Damage to the drive system or its environment INFORMATION Useful information or tip: Simplifies the handling of the drive system... Structure of the section-related safety notes Section safety notes do not apply to a specific action, but to several actions pertaining to one subject. The used symbols indicate either a general or a specific hazard. This is the formal structure of a section safety note: SIGNAL WORD Type and source of danger. Possible consequence(s) if disregarded. Measure(s) to prevent the danger... Structure of the embedded safety notes Embedded safety notes are directly integrated in the instructions just before the description of the dangerous action. This is the formal structure of an embedded safety note: SIGNAL WORD Nature and source of hazard. Possible consequence(s) if disregarded. Measure(s) to prevent the danger. 4 Manual Connecting MOVIFIT FDC-SNI to PROFIBUS/DeviceNet

General Information Right to claim under warranty. Right to claim under warranty A requirement of fault-free operation and fulfillment of any rights to claim under limited warranty is that you adhere to the information in the documentation at hand. Therefore, read the documentation before you start working with the software and the connected devices from SEW-EURODRIVE. Make sure that the documentation is available to persons responsible for the machinery and its operation as well as to persons who work independently on the devices. Also ensure that the documentation is legible..4 Exclusion of liability You must adhere to this documentation and the documentation of the connected devices from SEW-EURODRIVE to ensure safe operation and to achieve the specified product characteristics and performance features. SEW-EURODRIVE assumes no liability for injury to persons or damage to equipment or property resulting from non-observance of the documentation. In such cases, any liability for defects is excluded..5 Other applicable documentation This document does not replace the detailed operating instructions. MOVIFIT FDC-SNI and slave units as well as UFF4B may only be started up by electrical specialists observing the relevant accident prevention regulations and the following documents: Operating instructions "MOVIFIT FDC-SNI" "Fieldbus Gateway UFF4B, DeviceNet and PROFIBUS DP" manual Manual/online help for the "MOVITOOLS MotionStudio" engineering software Manuals for the configurable controller (CCU): Manual/online help for the configuration software "Application Configurator for CCU" Manuals/online helps for the various application modules (rapid and creep speed positioning, bus positioning, etc.) Manual for the freely programmable controller (MOVI-PLC ): MultiMotion for MOVI-PLC Manual Connecting MOVIFIT FDC-SNI to PROFIBUS/DeviceNet 5

Safety Notes General information Safety Notes. General information The following basic safety notes must be read carefully to prevent injury to persons and damage to property. The operator must ensure that the basic safety notes are read and adhered to. Ensure that persons responsible for the machinery and its operation as well as persons who work independently have read through the documentation carefully and understood it. If you are unclear about any of the information in this documentation or if you require further information, please contact SEW-EURODRIVE. The following safety notes refer to the use of the software. Also adhere to the supplementary safety notes in this document and in the documentation of the connected devices from SEW-EURODRIVE. This document does not replace the detailed documentation of the connected devices. This document assumes that the user has access to and is familiar with the documentation for all connected devices from SEW-EURODRIVE. Never install or start up damaged products. Submit a complaint to the shipping company immediately in the event of damage. During operation, the devices may have live, uninsulated, and sometimes moving or rotating parts as well as hot surfaces depending on their degree of protection. Removing covers without authorization, improper use as well as incorrect installation or operation may result in severe injuries to persons or damage to property. Refer to the documentation for additional information. 6 Manual Connecting MOVIFIT FDC-SNI to PROFIBUS/DeviceNet

Safety Notes Target group. Target group Any work with the software may only be performed by adequately qualified personnel. Qualified personnel in this context are persons who have the following qualifications: Appropriate instruction. Knowledge of this documentation and other applicable documentation. SEW-EURODRIVE recommends additional product training for products that are operated using this software. Any mechanical work on connected devices may only be performed by adequately qualified personnel. Qualified staff in the context of this documentation are persons familiar with the design, mechanical installation, troubleshooting and servicing of the product who possess the following qualifications: Training in mechanical engineering, e.g. as a mechanic or mechatronics technician (final examinations must have been passed). Knowledge of this documentation and other applicable documentation. Any electrical work on connected devices may only be performed by adequately qualified electricians. Qualified electricians in the context of this documentation are persons familiar with electrical installation, startup, troubleshooting and servicing of the product who possess the following qualifications: Training in electrical engineering, e.g. as an electrician or mechatronics technician (final examinations must have been passed). Knowledge of this documentation and other applicable documentation. Knowledge of the relevant safety regulations and laws. Knowledge of the other standards, guidelines, and laws mentioned in this documentation. The above mentioned persons must have the authorization expressly issued by the company to operate, program, configure, label and ground units, systems and circuits in accordance with the standards of safety technology. All work in further areas of transportation, storage, operation and waste disposal must only be carried out by persons who are trained appropriately. Manual Connecting MOVIFIT FDC-SNI to PROFIBUS/DeviceNet 7

Safety Notes Designated use. Designated use The SEW controller "MOVIFIT FDC-SNI" is currently only available with Ethernetbased fieldbus communication via PROFINET, Ethernet/IP or Modbus/TCP. In some cases, the MOVIFIT FDC-SNI unit has to be connected to PROFIBUS or DeviceNet. The document at hand describes how to connect the controller to PROFIBUS or DeviceNet using a fieldbus gateway and a software package..4 Bus systems A bus system makes it is possible to adapt frequency inverters and/or motor starters to the specific conditions of the machinery within wide limits. This results in the risk that a change of parameters that cannot be detected externally can result in unexpected, though not uncontrolled, system behavior. 8 Manual Connecting MOVIFIT FDC-SNI to PROFIBUS/DeviceNet

T L8 L7 S L6 L5 L4 L L L X0P 5 X8 0 ON 4 5 6 T L8 L7 S L6 L5 L4 L L L X0P 5 X8 0 ON 4 5 6 System Description System structure System Description. System structure The following figure shows the MOVIFIT FDC-SNI controller and a lower-level slave unit. The following units are possible as slaves: MOVIGEAR B SNI or MOVIGEAR B DSC (on SBus) MOVIFIT FC slave (on SBus) The fieldbus gateway "UFF4B" is connected with the controller (e.g. S7) and communicates with it (in the example via PROFIBUS). Additionally, the fieldbus gateway is connected with the controller and communicates with it via Modbus/TCP. 4 V Energy Controller Line filter UFF4B UFF4B PROFIBUS PROFIBUS X0D X0D 7 UFF4B/ UOHB 7 UFF4B/ UOHB X5 X5 L L XM S L L4 L5 4 X6 X7 Version X X IP: 9.68.0.y Modbus/TCP L L XM S L L4 L5 4 X6 X7 Version X X IP: 9.68.0.y Modbus/TCP H H X4 MOVIFIT -FDC-SNI H H X4 MOVIFIT -FDC-SNI X6 X6 4567 4567 IP: 9.68.0.4 IP: 9.68.0.4 Energy Energy Energy 4 V 4 V 4 V MOVIGEAR -SNI-B Single Line Installation MOVIGEAR -SNI-B Single Line Installation 9007008456075 Manual Connecting MOVIFIT FDC-SNI to PROFIBUS/DeviceNet 9

System Description Operating principle. Operating principle The "UFF4B" fieldbus gateway is equipped with the "OMG4B" SD card. The "Gateway application MF-FDC" software package is installed on the SD card. The fieldbus gateway enables the exchange of process data between the "MOVIFIT FDC-SNI" controller and the PLC. The gateway application on the SD card is necessary to have the fieldbus gateway convert the PROFIBUS/DeviceNet telegrams into Modbus/TCP telegrams and vice versa.. Scope of delivery The following components are included in the scope of delivery: Component Part number UFF4B 864 OMG4B memory card 89069 incl. "Gateway application MF-FDC" software package (84068) UOHB option 809750 INFORMATION The scope of delivery does not include any cables for fieldbus communication via Modbus/TCP and PROFIBUS/DeviceNet. 0 Manual Connecting MOVIFIT FDC-SNI to PROFIBUS/DeviceNet

Installation and Startup Requirements I 0 4 4 Installation and Startup 4. Requirements Correct project planning and proper installation are required for successful startup. You find detailed project planning information in the applicable documentation of the units used. 4. Voltage supply Connect MOVIFIT FDC-SNI and UFF4B with the DC 4 V voltage supply. 4. Settings of the fieldbus gateway Setting IP address and protocol. Switch on the DC 4 V supply of UFF4B. The "L" LED lights green and the "L4" LED flashes green ( Hz).. Change the IP address for Modbus/TCP communication and engineering. To do so, set DIP switch S to downward position as shown in the following table: DIP switch Up Down IP parameters (default) S IP address allocation The IP parameters defined on the memory card of the UFF4B gateway are used. The IP parameters for engineering interface X7 are entered in the file "...\System\NetConfig.cfg" in section "Ethernet ". You can adjust the file using a text editor (e.g. Notepad). Enter the IP address in the NetConfig.cfg file using a text editor. For details, refer to the manual "Fieldbus Gateway UFF4B DeviceNet and PROFIBUS DP". Note that different IP addresses have to be assigned to MOVIFIT FDC-SNI and UFF4B. For example, assign IP address 9.68.0.5 to the fieldbus gateway.. Switch off the supply voltage before continuing with step 4. 4. Set UFF4B to the required fieldbus protocol. To do so, set DIP switch S according to the following table: DIP switch Up Down S Fieldbus protocol PROFIBUS (X0P active) DeviceNet (X0D active) 5. Next, make the specific settings for the selected fieldbus protocol. Manual Connecting MOVIFIT FDC-SNI to PROFIBUS/DeviceNet

4 Installation and Startup Settings of the fieldbus gateway Setting for PROFIBUS Setting for DeviceNet Set the station address for PROFIBUS communication using DIP switches 0 6 : UFF4B 0 ON 4 5 6 7 78054580 The default setting for the station address is 4: 0 Significance: 0 = 0 Significance: 0 = 0 Significance: 4 = 4 Significance: 8 0 = 0 4 Significance: 6 0 = 0 5 Significance: 0 = 0 6 Significance: 64 0 = 0 Set the MAC-ID (Media Access Control Identifier) for DeviceNet communication using DIP switches 0 5 : UFF4B 0 ON 4 5 6 7 0 5 = MAC ID setting 6 7 = Baud rate setting 780500 Set the baud rate for DeviceNet communication using DIP switches 6 7 : DIP switch Baud rate 6 7 0 0 5 kbaud 0 50 kbaud 0 500 kbaud Invalid Manual Connecting MOVIFIT FDC-SNI to PROFIBUS/DeviceNet

Installation and Startup Fieldbus installation I 0 4 4.4 Fieldbus installation. Connect the controller with the fieldbus gateway (X7) using a Modbus/TCP cable. Observe the installation instructions in the operating instructions for MOVIFIT FDC- SNI and the manual "Fieldbus Gateway UFF4B DeviceNet and PROFIBUS DP".. Connect the fieldbus port of the controller with the matching fieldbus connector on the fieldbus gateway: X0P: PROFIBUS X0D: DeviceNet Observe the installation instructions in the "Fieldbus Gateway UFF4B DeviceNet and PROFIBUS DP" manual as well as the installation instructions of the controller manufacturer. 4.5 Controller settings Setting the IP address When you operate the Modbus/TCP communication and the local engineering interface (Ethernet) in the same local network, you have to set another IP address for engineering than for fieldbus communication. For example, assign IP address 9.68.0.6 to the local engineering interface. Do not change the default IP address 9.68.0.4 for fieldbus communication. If you access both interfaces from different networks, you need not change the IP address of the engineering access.. Swith on the supply voltage of the controller.. If required, change the IP address for engineering. To do so, set DIP switch S/ = "ON" according to the following table: DIP switch S/ IP address allocation OFF IP parameters (default): IP address: 9.68.0.4 Subnet mask: 55.55.55.0 Standard gateway:.0.0.0 ON The IP parameters defined on the memory card of MOVIFIT FDC- SNI are used. Enter the IP address in the NetConfig.cfg file using a text editor (same procedure as for the fieldbus gateway). Note that different IP addresses have to be assigned to MOVIFIT FDC-SNI and UFF4B. Manual Connecting MOVIFIT FDC-SNI to PROFIBUS/DeviceNet

4 I 0 Installation and Startup Installation and startup of slave units Setting the fieldbus protocol. Switch off the supply voltage.. Set the fieldbus protocol "Modbus/TCP" on MOVIFIT FDC-SNI. To do so, set DIP switch S/ on the EBOX to OFF position according to the following table: DIP switch S/ Fieldbus protocol OFF EtherNet/IP or Modbus/TCP ON PROFINET IO 4.6 Installation and startup of slave units Install and start up the slave units as described in the operating instructions of the respective unit. Do not exceed the maximum number of slave units. The following table shows how many units of the same type you can operate on the controller: Slave unit Max. number of slave units of the same type MOVIGEAR B SNI 0 MOVIGEAR B DSC (on SBus) 6 MOVIFIT FC slave (on SBus) 6 If you combine different types of units, then a maximum of 6 units is allowed (e.g. 0 MOVIGEAR B SNI and 4 MOVIGEAR B DSC). 4.7 Starting up the controller and the PLC. Switch on the 4 V supply of MOVIFIT FDC-SNI. The "4 V_C" LED should now light up green.. Follow the startup procedure (described in the operating instructions of MOVIFIT FDC-SNI, chapter 6.4).. Configure the connected axes. You find details on the software tools of the configurable controller (CCU) in the following manuals/online help: Configuration software "Application Configurator for CCU" CCU application modules (rapid and creep speed positioning, bus positioning, etc.) You find details on the software tool for the freely programmable controller (MOVI-PLC ) in the manual/online help: MultiMotion for MOVI-PLC 4. Start up the PLC according to the manufacturer's specifications. The "L5" LED on UFF4B lights up green when Modbus/TCP and PROFIBUS/ DeviceNet communication has been established successfully. For other conditions, refer to the table in the next chapter "Diagnostics". 4 Manual Connecting MOVIFIT FDC-SNI to PROFIBUS/DeviceNet

Diagnostics UFF4B status display 5 5 Diagnostics 5. UFF4B status display To diagnose errors, refer to the following table with states of the "L5" LED on the UFF4B fieldbus gateway: L5 status Diagnostic information Green Modbus/TCP communication established PROFIBUS connection o.k. Red No Modbus/TCP communication established PROFIBUS communication fault Lit red, or flashing red (4 Hz) (reserve status) Lit red, or flashing red ( Hz) (reserve status) Modbus/TCP communication fault Undefined PROFIBUS communication PROFIBUS communication fault Undefined Modbus/TCP communication Flashing green/orange (4 Hz) Modbus/TCP communication fault PROFIBUS communication established Flashing green/orange ( Hz) Modbus/TCP communication established PROFIBUS communication fault Off Gateway application inactive Manual Connecting MOVIFIT FDC-SNI to PROFIBUS/DeviceNet 5

Index Index B Bus system...8 C Components...0 Controller Setting the IP address... Setting the protocol... D DeviceNet, setting MAC ID and baud rate... Diagnostics with LED "L5", UFF4B...5 DIP switches S/ and S/S... S/S... Display LED "L" and "L4"... LED "L5"...4 E Embedded safety notes...4 Engineering access, local network... Exclusion of liability...5 F Fieldbus gateway...0 Setting the IP address... Setting the protocol... G Gateway application, UFF4B...0 I Installation Fieldbus... Voltage supply... Interface, engineering access... L LED display "L" and "L4"... "L5"...4 LED display, status...5 Liability...5 Liability for defects...5 Local network, engineering access... M Max. number, slave units...4 Modbus/TCP... MOVIFIT FC slave...4 MOVIFIT FDC-SNI Setting the IP address... Setting the protocol... MOVIGEAR B DSC...4 MOVIGEAR B SNI...4 N Notes Designation in the documentation...4 O OMG4B, SD card...0 Operating principle...0 P PLC, startup...4 PROFIBUS, setting the station address... S Safety notes...6 Designation in the documentation...4 General information...6 Structure of the embedded safety notes...4 Structure of the section-related safety notes...4 Scope of delivery...0 SD card, OMG4B...0 Section-related safety notes...4 Setting the fieldbus protocol Controller... Fieldbus gateway... Setting the IP address Controller... Fieldbus gateway... Signal words in the safety notes...4 Slave units, max. number...4 6 Manual Connecting MOVIFIT FDC-SNI to PROFIBUS/DeviceNet

Index Startup DeviceNet on fieldbus gateway... Modbus/TCP on the controller... PROFIBUS on fieldbus gateway... Required software tools and documentation...4 Requirements... startup PLC...4 Startup procedure, controller...4 Status, LED display...5 System Description...9 T Target group...7 Topology...9 U UFF4B, diagnostics with LED "L5"...5 Units...0 UOHB...0 Manual Connecting MOVIFIT FDC-SNI to PROFIBUS/DeviceNet 7

SEW-EURODRIVE Driving the world SEW-EURODRIVE Driving the world SEW-EURODRIVE GmbH & Co KG P.O. Box 0 D-7664 Bruchsal/Germany Phone +49 75 75-0 Fax +49 75 75-970 sew@sew-eurodrive.com www.sew-eurodrive.com