Analytical Instruments Two-Wire ph, ORP, plon Transmitters

Similar documents
Analyze IT Analytical Instruments Two-Wire ph, ORP, plon Transmitters

ABB MEASUREMENT & ANALYTICS DATA SHEET. TB84PH ph /ORP / pion transmitter

ABB Automation. Advantage Series ph/orp/pion Analyzer. Type TB84pH. Specification. Simple menu programming (patent pending).

TB84TE Conductivity transmitter 2-Electrode. Superior accuracy in low conductivity and pure water. applications

FICHA TÉCNICA DE PRODUTO

Inform IT Single Pen Circular Chart Recorder

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

/8 DIN Universal Process Indicator

CURRENT TO PROFIBUS PA CONVERTER

Wall-/Pipe Mounted Universal Process Indicator

100mm Process Indicator Recorder

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Electro-Magnetic Flowmeters Converters

SIY. Features. PC-Programmable Signal Isolator/Converter

General Specifications

General Specifications

User Guide OI/TB84PH EN Rev. C. Type TB84pH Advantage Series TM ph/orp/pion transmitter

SFY Functional Safety Frequency-to-DC Transmitter with Display

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

Dräger Polytron 8200 Stationary gas detector (CatEx)

/8 DIN Motorized Valve Controller

C160 Wall-/Pipe Mounted Universal Process Indicator

Temperature process values at a glance

3420 Fieldbus Interface Module (FIM) Contents

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

Model T28 Transmitter

PD301 - PD306 Head Mount SMART TEMPERATURE TRANSMITTERS

BLISS ANAND. BA-Series Magnetostrictive Level Transmitter

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010

FICHA TÉCNICA DE PRODUTO

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Advantage Series ph/orp/pion Transmitter

Level-Lance Model 5400A

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR3/4 MLG Transmitter with Analog Output.

FLEX Ex Spring Clamp Terminal Base

HIT/HIX HART Isolator

+GF+ SIGNET ph/orp Transmitter Instructions

BA414DF Fieldbus indicator Single variable

M-series Intrinsically Safe I/O

SIY. New. Features! Features. PC-Programmable Signal Isolator/Converter

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas

HART UNIVERSAL TEMPERATURE TRANSMITTER

Universal Process Controller

Intrinsically Safe Barriers

SDY. PC-Programmable Signal Isolator/Converter with Display

HART UNIVERSAL TEMPERATURE TRANSMITTER

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Thermal Mass Flowmeter Sensyflow FMT200-D

Continuous level measurement Radar transmitters

4110 HART Level Encoder

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

TRANSMISSOR DE PRESSÃO PIEZO RESISTIVO INTELIGENTE MICRO PROGRAMÁVEL SÉRIE PAS

Device Type Manager DTM for TF12, TF212

Reed sensor For bypass level indicators Model BLR

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

INSTRUCTION MANUAL MODEL RTI-EC RESISTANCE TEMPERATURE INDICATOR TABLE OF CONTENTS 1. GENERAL DESCRIPTION PAGE 1

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

UNIVERSAL TEMPERATURE TRANSMITTER

OPERATION MANUAL MODEL TT-LP

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

Description, continued

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

JT400 Multivariable Transmitter

Control IT Booster Pump Controller

Technical Information RIA15

MODCELL 2050R Single Loop Controllers

Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller

Explosion-Proof Gauge Pressure Transmitter

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

5 Fieldbus Technology

Indicators. Hazardous-Area Indicators. 830 X R Loop-Powered 16 Process Indicator. 830 X S1 Loop-Powered 16 Process Indicator

SEM310 SEM310X HART UNIVERSAL TEMPERATURE TRANSMITTER

DREXELBROOK. Datasheet Universal IV In-Line Water Cut Meter. with Spool Piece Mounting USE THE BEST APPLICATIONS. Eliminate Routine Maintenance

-Camille Bauer Div. of Absolute Process Instruments, Inc. Phone: Fax: J-1

Universal IV Water Cut Meter

Technical Information RIA16

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

AS-interface Network Card

µflo 6200 Series Overview 6200 Series Products µflo 6200 Series

BXD17 Series. Features. Analytical instrumentation for your measurement applications.

SCADAPack Modbus multivariable transmitter

Stratos Pro A4 PH. Connection

Dräger Polytron IR. Dräger Polytron IR: Configurable gas detector for reliable detection of combustible gases and vapours.

S-series Foundation Fieldbus I/O

HIGH-VOLTAGE DC METER

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

+GF+ SIGNET Conductivity/Resistivity Transmitter Instructions

TEPI11 P/I signal converter

Discrete I/O connected direct onto. Input and Output Function Blocks. Two built-in Solid State Relay Outputs. Discrete Function Blocks in the field

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

LineGuard Specification Sheet Issued 8/24/10 VA Revision 0. Valve Automation

Transcription:

Data Sheet Analytical Instruments Two-Wire ph, ORP, plon Transmitters Model TB82PH Series Designed With the Real World in Mind Easy to use menus guide the operator through set-up, calibration and maintenance Simple Menu Guided Configuration Allows users to easily setup and customize transmitter to suit their specific needs Advanced Digital Communications Available with PROFIBUS PA, FOUNDATION Fieldbus or HART communications Industrially Hardened Design Transmitters that withstands the harshest environments Large, Easy-to-Read Display Shows primary measurement along with user-selectable secondary display (temperature, output current or sensor input) Industrial IT Level 1 Conformance Seamlessly integrates onto existing ABB control systems. Also certified for use on Delta V control platform and may be used on nearly every available control platform. Programmable Security Codes Prevents unauthorized modifications to transmitter configuration and calibration TB82PH - a leap forward in 2-wire ph/orp/plon transmitter technology Intrinsically Safe, Non-incendive Design Permits use in hazardous areas

General Description The rugged ABB Type TB82 Series of two-wire ph, ORP (REDOX), pion transmitter is designed for a broad range of industries from chemical, power, and pulp & paper to water & wastewater treatment. The TB82 Series is available with traditional programmable outputs or with advanced digital communications utilizing Foundation Fieldbus (FF), PROFIBUS PA (PA) or HART. Setup, maintenance and operation in the field is simple. Easy to follow instructions appear above each Smart Key. The user-friendly interface provides for straightforward transmitter configuration and calibration. A unique secondary display clearly defines each menu option when programming the transmitters. During normal operation, the secondary display may be configured to show process temperature, current output, mv or software revision depending upon configuration. The Type TB82 series transmitters meet current CE, NEMA 4X, IP65, CSA, FM, ATEX and FISCO requirements. Sensor Compatibility The TB82PH transmitter accepts ABB ph, oxidation/ reduction potential (ORP) and ion-selective (pion) sensors in addition to most competitors. Calibration In addition to the traditional two-point calibration, the TB82 features a simple one-point process calibration to adjust for offsets that may occur when the sensor is in process. When initiating a two-point calibration, the user has the option to hold the analog output at a defined level. If necessary, the TB82 may be easily reset back to a factory calibration. Programmable Security Code The transmitter has a three-digit security code to prevent unauthorized modifications that may be applied to any combination of the following menus: Calibration, Output/ Hold, Security, and Configure. Basic or Advanced Programming Modes (FOUNDATION Fieldbus, PROFIBUS PA and HART models available in Advanced mode only) Available with either Basic or Advanced programming modes at time of purchase, the Advanced mode offers an expanded feature set for more complex operations, such as: Automatic Nernstian With Solution Coefficient Temperature compensates the sensor output to standard temperature value of 25º C using the Nernst equation and a solution coefficient Ion Concentration Converts a pion sensor output to concentration units such as parts per million or parts per billion Analog pulse diagnostic output: Impresses 0.16 to 16 ma pulse on the 4 to 20 ma output to alert operator of a fault condition (Not available on transmitters with digital communication) Diagnostics The transmitter constantly monitors both itself and the sensor to ensure reliability and accuracy. Upon detection of a diagnostic condition, the transmitter provides diagnostic notification by flashing FAULT on the display and supplying a pulse on the analog output (if activated on non-hart devices). Transmitters equipped with Foundation Fieldbus or PROFIBUS PA send a complete diagnostic description over the network to the controller. This allows for easy, immediate troubleshooting. Pressing FAULT info on the transmitter provides a short description and fault codes on the secondary display. The FAULT icon remains active until problem has been resolved. Sensor faults that active the diagnostic notification are: Broken glass electrode 1 High reference impedance 1 Shorted or damaged cable Open cable Sensor is not in contact with solution 1 Shorted or open temperature compensator Ground loop 1 Note 1 : requires the use of ph sensors with solution ground rods such as the ABB TBX5 series sensors. 2

Adjustable Damping Damping is helpful in process environments where noise is present. It is a capacitive type lag where reaction to any signal change is slowed according to the entered time constant. For example, the response to a step input change reaches approximately 63 percent of its final value in five seconds for five seconds of damping. Communications FOUNDATION Fieldbus (FF) addresses modern instrument users needs for flexibility and cost savings, while providing a whole host of additional features. Measurement variable quality and diagnostic conditions transmitted during each scheduled data transfer Easily configured remotely or locally Transmission of multiple process variables utilizes two Analog Input Blocks (AI) Transmitter characteristics such as device name, manufacturer and serial number via a Standard Resource Block Configuration and calibration capability via custom Enhanced Transducer Block Provides calibration Methods on supported host tools and systems PROFIBUS PA (PA) is a standardized, open, digital communications system for process automation. Configuration, calibration and trending available via a Device Type Manager (DTM) when used on compatible host tools and systems Measurement variable quality and diagnostic conditions transmitted during each scheduled data transfer Remote and local configuration capability Choice of Standard Analyzer Profile or Manufacturer Specific Profile conforms to PROFIBUS PA Profile requirements v. 3.0 GSD files available on all product variations Utilizes one Physical, one Transducer, and two Analog Input Blocks HART communications protocol provide remote programming via any HART compatible primary or secondary communications device. Digital communications through a low-level modulation superimposed on the standard 4-to-20 ma current loop Accommodates Universal, Common Practice and Device Specific Command Sets for functionality within HART networks and for use with HART handheld terminals Driver files for various host systems and tools available. Visit www.abb.com/instrumentation. Specifications Type 2-wire ph, ORP, plon transmitter Input Sensor Types Glass, antimony (Sb), custom iso-potential and asymmetric potential ORP: Platinum (Pt), gold (Au) pion: Sodium (Na), chloride, sulfide, etc. Input Range ORP/pIon: 0 to 14 ph (with 2 to +16 ph over range) +/- 1999 mv Input Temperature Compensation Types Pt 100, 3 kω Balco RTD Temperature Display Range -20 to 300 C (-4 to 572 F) Temperature Compensation Modes ph/orp/plon: Manual Nernstian, standard automatic Nernstian, automatic Nernstian with solution coefficient Accuracy, Repeatability, Non-linearity ph display: +/- 0.01 ph ORP display: +/- 1 mv pion display: +/- 1 mv Temperature Display:1 C or 1 F Output: +/- 0.02 ma (non-ff devices) 3

Lightning Suppressor Installed integral to the transmitter to suppress lightning induced transients. Tested to suppress 10 successive 8 by 20-µsec pulses with a peak value of 20 ka (reference IEEE C62.41) Stability ORP/pIon: Output: Temperature: +/- 0.01 ph +/- 1 mv +/- 0.01 ma 1 C or 1 F Power Requirements Standard: 14.0 to 53 VDC (14.0-42 VDC for certified applications) HART: 14 to 53 VDC (14-42 VDC for certified applications). For HART communication, a 250 Ω resistor is required; 19 VDC minimum voltage required. 14 VDC required for liftoff Foundation Fieldbus & PROFIBUS PA bus powered: 9-32 VDC (non-i.s. model) 9-24 VDC (I.S. model) 15 ma quiescent current consumption Agency Certifications ATEX 100A ATEX Category II 1G; EEX ia, Zone 1; Group IIC, T4 when used with appropriate barriers Canadian Standards Association (CSA) Intrinsic safety: Class I, II, III; Division 1; applicable Groups A, B, C, D, E, F and G; when used with appropriate barriers. T3C Non-incendive: Class I, Division 2, Groups A, B, C, and D. Class II, Division 2, Groups E, F and G. Class III, Division 2 Factory Mutual (FM) Intrinsic Safety: Class I, II, III; Division 1; applicable Groups A, B, C, D, E, F and G; when used with appropriate barriers. T3C (Max ambient Temperature: 60 C Non-incendive: Class I, Division 2, Groups A, B, C, and D. Class II, Division 2, Groups F and G. Class III, Division 2. T5 Fieldbus Intrinsically Safe Concept (FISCO) Fieldbus products (FF and PA) meets the requirements for the FISCO model EMC Requirements CE Certified complies with all applicable European Community product requirements, specifically those required to display the CE markings on the product nameplate. Dynamic Response 3 secs for 90% step change at 0.00 sec damping Output ORP/pIon: Output Minimum Span 1.00 ph ORP/pIon: 100 mv Isolated 4 to 20 ma, linear and nonlinear, configurable across full ph range Isolated 4 to 20 ma, linear and nonlinear, configurable across full range Output Maximum Span (Full scale settings) 14 ph units ORP/pIon: -1999 to 1999 mv Damping Adjustable: 0.0 to 99.9 seconds Environmental (Temperature) Operating: -20 to 60 C (-4 to 140 F) LCD: -20 to 60 C (-4 to 140 F) Storage: -40 to 70 C (-40 to 158 F) Humidity: up to 95% RH Enclosure NEMA 4X and IP65, anodized aluminum alloy with polyester powder coating Size (1/2 DIN) H x W x D: 144.0 x 144.0 x 171.0 mm 5.67 x 5.67 x 6.73 in. Min. panel depths: 144.8 mm (5.70 in.) Max. Panel thickness: 9.5 mm (0.38 in.) Panel cutout: 135.4 (+1.3, -0.8) by 135.4 (+1.3, -0.8) mm 5.33 (+0.05, -0.03) by 5.33 (+0.05, -0.03) in. Weight: 1.9 kg (4.2 lb) 3.4 kg (7.5 lb) with pipe mounting hardware Conduit Connections Two (2) each: 22.2 mm (0.875 in.) holes in enclosure that accepts ½ inch hubs. 4

Overall Dimensions FRONT SIDE BOTTOM 26.7 1.05 10.2 0.40 143.8 5.66 143.5 5.65 114.0 4.49 143.8 5.66 50.8 2.00 41.9 1.65 DIMENSIONS MILLIMETERS INCHES 14.0 0.55 (4 TYP) 32.8 1.29 (4 TYP) 22.2 DIA 0.88 (2 TYP) T01688C Pipe Mounting Option DIMENSIONS MILLIMETERS INCHES 12 0.47 PIPE MOUNT BRACKET FLATWASHER (4) 203 8.00 Pipe 12 0.47 5/16" NUT (4) 5/16" U-BOLT (2) 5/16" X 5/8" BOLT (4) 5/16" FLATWASHER (4) Panel Mounting Option PANEL CUTOUT 135.4 +1.3 0.8 5.33 +0.05 0.03 9.5 MAXIMUM PANEL 0.38 THICKNESS PANEL MOUNTING BRACKET (4) PANEL MOUNTING SCREWS (4) 11.9 0.47 135.4 +1.3 0.8 5.33 +0.05 0.03 REAR COVER REMOVED 11.9 0.47 MINIMUM PA NEL DEPTH = 144.8 MM (5.70 IN.) PANEL GASKET PANEL EXTERNAL GROUND SCREW REAR VIEW 3/8-IN. 3/8-16 x 1/2-IN. HEX SCREW (4) T01088E 5

Wall (Side) Mounting Option PIPE MOUNT BRACKET FLATWASHER (4) DIMENSIONS MILLIMETERS INCHES FASTENERS FOR WALL (SUPPLIED BY OTHERS) 227 8.94 WALL WALL X 5/8" BOLT (4) Wall/Hinge (Rear) Mounting Option TOP VIEW FRONT VIEW FASTENERS FOR WALL (SUPPLIED BY OTHERS) X 3/4" BOLT (8) S.S. HINGE FLATWASHER (4) WALL PIPE MOUNT BRACKET "L" BRACKET NUT (8) FLATWASHER (8) LOCKWASHER (8) X 5/8" BOLT Typical Wiring Diagram POWER SUPPLY VOLTAGE AT POWER TERMINALS TB1-1 AND TB1-2 MUST BE BETWEEN 14.0 AND 53VDC THE MINIMUM POWER SUPPLY VOLTAGE IS 14.0VDC + (0.02 AMPS X TOTAL LOOP RESISTANCE IN OHMS). THE MAXIMUM POWER SUPPLY VOLTAGE IS 53VDC 6

Base Model TB82 Model TB82 PH X X 1 0 X X X Input Type ph, ORP, plon PH Programming Option 1 Basic 1 Advanced 2 Digital Communications Option None (Analog Only) 0 HART 1 FOUNDATION Fieldbus 2 PROFIBUS PA 3 Lightning Suppressor Included 1 Housing Type Powder Coated Aluminum 0 Mounting Options None 0 Pipe 1 Wall/Hinge (Rear Mount) 2 Panel 3 Wall (Side Mount) 4 Agency Approvals None 0 FM (Factory Mutual) 1 CSA (Canadian Standards Association) 2 ATEX 100A 3 Tag None 0 Stainless 1 Mylar 2 Accessories: Part Number 4TB9515-0123 4TB9515-0124 4TB9515-0125 4TB9515-0156 4TB9515-0164 4TB9515-0166 Description Panel Mounting Kit Pipe Mounting Kit Hinge Mounting Kit Wall Mounting Kit BNC Adapter BNC Adapter with Liquid Tight Cable Fittings Product Instruction Manuals: (One copy supplied with instrument at no charge) Notes: 1. Advanced Programming Option must be selected for HART, FOUNDATION Fieldbus and PROFIBUS PA Digital Communication Option 7

Notes ABB has Sales & Customer Support expertise in over 100 countries worldwide www.abb.com The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in USA (2.7.06) ABB 2006 ABB Inc. 125 East County Line Road Warminster, PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 ABB Inc. 9716 S. Virginia St., Ste E Reno, NV 89521 USA Tel: +1 775 850 4800 Fax: +1 775 850 4808 ABB Limited Oldends Lane, Stonehouse Glouchestershire, GL 10 3TA UK Tel: +44 (0)1453 826661 Fax: +44 (0)1453 829671 8