DOOR FRAME DOOR LEAF. Potential-free contact for external: Intercom Switch. - Home automation system. = 110V AC, 60Hz

Similar documents
Installing Keypad and Backplate

IMPORTANT AS YOU REMOVE THE CONNECTORS LABEL THE CONNECTOR WITH THE NAME OF PLUG WITH THE SHARPIE

Roto E-Tec. Electronic drive and control systems for windows and doors. Installation instructions for detachable miniature cable junctions

Digital Keypad Introduction

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution

MLC 420. MAGNETIC Press Brake ENCODERS OPERATION MANUAL

GV-EL124S Electric Strike

PowerFlex DC Drive Frame B Pulse Transformer Circuit Board

Skullcandy Air Raid USB Board Replacement

PowerFlex DC Drive - Frame A Switching Power Supply Circuit Board

CM-110SK Standalone Keypad Installation Instructions

ilock control unit Wiring Manual website: phone: +(48)

(Catalog Numbers 1394-FK10TS and -FK22TS)

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual

Ultra short throw lens installation

Megatouch FORCE Monitor Chassis Board Replacement

Connecting a Cisco Reader Module

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

Removal and Installation8

74 PS range Push-buttons, selectors and indicators Ø 22mm

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

R SERIES INSTALLATION GUIDE

PowerBook G4 Aluminum 15" GHz Modem Replacement

Front-door station series for surface-mounting Profi-Economic PES Profi-Design PDS

Absolute encoders - bus interfaces Solid shaft with clamping or synchro flange Optical multiturn encoders 13 bit ST / 12 bit MT, RS485

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

Product and functional description

The following forms are included. Computer files are contained in the directory v:\aqg_ops\improve\field_information\mailaudt. 1point.

ilock control unit Wiring Manual website: phone: +(48)

lumentouch SPECIFICATION SHEET Client: Project name: Order #: Type: Qty: FEATURES AND BENEFITS PACKAGE CONTENT HOW TO ORDER LTO

Overview of types. Technical data

MobileView Junction Box

PowerFlex DC Drive - Frame A SCR Modules for Drives with a Power Traces Circuit Board

WINSTA. Full Line Catalog 2008/2009

Incremental encoders Solid shaft with EURO flange B pulses per revolution

E1135C PDU and Pod Upgrade Procedure

Single-Core PVC 6491X

Upgrading LVDS Cables Instruction Sheet

HC900 Remote Termination Panel (RTP) For Relay Outputs

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

Absolute encoders - SSI

Welch Allyn Connex Vital Signs Monitor 6000 Power Supply Replacement

Olympus TG-820 ihs Lens Replacement

RSL PSM-2 Power Supply Module Project: Modifying a FlatCap2

Inductive displacement measurement system model series IE25P with programmable analogue interface

Sales: Technical: Fax:

optical sensors through-beam, retro-reflective, dif. reflection sensors 3000 transmitter with test input robust metal housing

Lenovo IdeaTab A1000L Audio Jack

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

Oracle <Insert Picture Here>

PowerBook G4 Aluminum 15" GHz PC Card Cage Replacement

Mac mini Late 2014 Power Supply Replacement

Control Box Setup - PRSalpha

SERIE 59. Rear clamp. Frontal clamp HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS

APES-14 HD-6500 & HD-7000 Version Operator s Training Manual

Fuser. Figure Remove the fuser assembly (1 of 2) 184 Chapter 5 Removal and replacement ENWW

Reference Guide METTLER TOLEDO WMH Weighing Platforms

Sony NEX-7 Screen Replacement

Home Automation, Inc. Model 53A00-1. OmniTouch 5.7 Touchscreen with Video

Electronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Installing 6 Indexer: PRS Standard Tools

Solid State Remote Power Controller E

POSIROT. PRAS2EX Magnetic Angle Sensor. Magnetic Angle Sensors (Dust-Ex-proof) Datasheet

Incremental Encoder with Hollow Shaft

Topic: TB No.: Date: Aug/2017. Model UC4, UC10 & UC45 twin pump variants Regulated 24V Pump Power supply upgrade OVERVIEW

PHOENIX CONTACT - 01/2008

Installation Guide AWRON Display F26DGA

Contents. BMS icom Manual

Connector System for Fluorescent Lighting Fixtures. Connectors for In-Line Mounting of Fluorescent Lighting Fixtures. Fully Polarized Connectors

Xbox One Heat Sink Replacement

INSTALLATION INSTRUCTIONS

GSV-1A4 M12/2 M12/2. Highlights

Product and functional description

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

ibook G3 14" Top Shield Replacement

Material: Weight: Shaft Loads: Cable: Connector:

OPERATING INSTRUCTION

Thermoelectric Cooler Controller TED1000

Useful Notes: Guide to Railway Telephones

Adapter Kit - Remote QSI Electronics Installation Instructions

L Series Humidity/-temperature sensors for use in heating, ventilation and air conditioning Technical data Humidity

Technical data. Your advantages

NOVOTURN Multiturn-Sensor non-contacting. Series RSM2800 digital SSI, SPI

Supplementary instructions. Plug connector Harting HAN 7D. For point level sensors. Document ID: 34456

Installation Guide for Mazak Mazatrol M - Plus, M-2, M32, T-Plus, T2

Model No. ET-JPF200BE

Xbox 360 Motherboard Replacement

Hinged safety switches, Palladio line

The sensor fulfills the specifications of the EMC requirements, if the instructions in the manual are followed.

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

IT 1910i. Industrial 2D-code hand-held scanner TECHNICAL DESCRIPTION. make technical changes EN /06. We reserve the right to

ADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you

Power distribution systems - accessories

AC LEISURE PRO SHORE COMMANDER

PowerFlex 700L Liquid-to-Liquid Heat Exchanger Control Board Replacement

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

RCM-810. Technical specifications. Electro-Voice RCM-810. Enable powerful control and supervision capabilities

Connecting a Cisco Output Module

Transcription:

SECURY Solid Automatic, brass handle, & 45mm Cable plate Duct, series DOOR FRAME DOOR LEAF Potential-free contact for external: - Intercom - Switch - Home automation system 03 5 Junction box SECURY Automatic Black = switch Grey = -0V Brown = +24V Cable duct Potential-free contact Intercom Switch Power supply = (not supplied) to, Cable duct = 6-29854-00-0-0 SECURY Automatic = 6-28485-XX-0-8 = K-18153-01-0-1

GU-SECURY Solid brass Automatic handle with & 45mm plate Technical series Data Sheet Release: (potential-free contact) e.g. intercom or access control system +/~ /~ + Distribution box Cable duct 123 Black = control circuit Grey (blue) = minus Brown = plus 3 2 3 1 2 1 Optional: use of cable disconnection plugs (included in delivery)

SECURY Solid Automatic, brass handle, & 45mm SECUREconnect plate series 200, Fingerprint Scanner or Code Keypad, DOOR FRAME DOOR LEAF Potential-free contact for external: - Intercom - Switch Optional or 03 5 Fingerprint scanner Code keypad Term.: V4 / 93 (short term open) SECURY Automatic Term.: V42(+) / G42(-) Black = 90 Grey = GS Brown = VS 94 = Brown 95 = Green 96 = White GS = Yellow Potential-free contact Intercom Switch Power supply = (not supplied) to, SECUREconnect 200 = B-55600-20-4-6 Faceplate for = 9-45903-01-0-8 SECUREconnect (2 required) Fingerprint scanner = B-55600-23-4-8 or Code keypad = B-55600-20-4-8 SECURY Automatic = 6-28485-XX-0-8 = K-18153-01-0-1

, Solid brass SECUREconnect handle & 200, 45mm Fingerprint plate series Scanner or Code Keypad Connection Diagram Cable routing of module (leaf-side) Please use the enclosed system cable to connect the module. The SECUREconnect and the access control module communicate via an encoded bus. SECUREconnect 200F Connecting cable Grey (blue) Brown Black Signal GND (minus) 24 V (plus) Control line GS VS 90 Fingerprint scanner or code keypad Connecting cable Yellow White Green Brown Signal GND (minus) RS-485 A RS-485 B 24 V (plus) GS 96 95 94 Connection terminals of SECUREconnect 200R (frame-side) The terminals V42 and G42 are provided for the connection of an external voltage supply to operate SECUREconnect 200. Attention: Only voltage sources in accordance with EN 60950 may be used. Stabilized power supply 110V AC /, Switch control (optional) SECUREconnect 200R

SECURY Solid Automatic, brass handle, & 45mm SECUREconnect plate series 200, DOOR FRAME DOOR LEAF Potential-free contact for external: - Intercom - Switch - Access control 03 5 Term.: V4 / 93 (short term open) Term.: V42(+) / G42(-) SECURY Automatic Black = 90 Grey = GS Brown = VS Potential-free contact Intercom Switch Access control Power supply = (not supplied) to, SECUREconnect 200 = B-55600-20-4-6 Faceplate for = 9-45903-01-0-8 SECUREconnect (2 required) SECURY Automatic = 6-28485-XX-0-8 = K-18153-01-0-1

Assembly Door Multi-point Multipoint and Operating Locking Instructions System, Solid brass SECUREconnect handle & 200 45mm Connection plate series Diagram Connection diagram SECURY Automatic with (leaf-side) Impulse-controlled door opening time approx. 2s (cannot be adjusted). Permanent door opening time corresponds to duration of control signal. SECUREconnect 200F GS VS 90 Connection terminals of SECUREconnect 200R (frame-side) The terminals V42 and G42 are provided for the connection of an external voltage supply to operate SECUREconnect 200. Attention: Only voltage sources in accordance with EN 60950 may be used. Stabilized power supply 110V AC /, Switch control SECUREconnect 200R

Door Multi-point Locking System Assembly Door Multipoint Instructions Locking System How Solid to Reverse brass Latches handle & Connect 45mm plate Extension series to Door Lock REVERSE LATCH (Use flathead screwdriver) REVERSE AUTOMATIC LATCH (Use 4mm Allen T-key H-00345-04-0-0) 2 1 2 1 3 1. Presse slightly while pulling the latch 4 4 3 5 CONNECT AUTOMATIC EXTENSIONS TO DOOR LOCK (Use Torx 15 T-key H-00346-15-0-0) Cutting dimension 220mm 1. Loosen screw (do not remove) 2. Remove screw 470mm 3. Hook the driving rod to the coupling plate and retighten both screws How to Reverse Latches & Connect Extension to Door Lock_ V.05.2014