General Specifications

Similar documents
General Specifications

General Specifications

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

General Specifications

General Specifications

General Specifications

FLEX Ex Spring Clamp Terminal Base

Fisher i2p-100 Electro-Pneumatic Transducer

Type i2p-100 Electro-Pneumatic Transducer

ABB MEASUREMENT & ANALYTICS DATA SHEET. JDF200 Field Indicator

Explosion Proof I/P Transducer

Series 3730 Type Electropneumatic Positioner

Level-Lance Model 5400A

SCADAPack Modbus multivariable transmitter

SIY. Features. PC-Programmable Signal Isolator/Converter

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

Dräger Polytron 8200 Stationary gas detector (CatEx)

Sensor boxes SRBE Key features and product range overview

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Level limit switch Series RF 3000 Selection list. Overview 2

PD301 - PD306 Head Mount SMART TEMPERATURE TRANSMITTERS

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

T EN TROVIS Electropneumatic Positioner

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

General Specifications

MODEL: MD7TC. Lightning Surge Protectors for Electronics Equipment M-RESTER

Series 3730 Electropneumatic Positioner Type

NELES ND7000 DIGITAL VALVE CONTROLLER

FloBoss 107 IEC Interface

SCADAPack Modbus multivariable transmitter

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas

Supplementary Components WirelessHART products

Terminal Boxes Series 8118

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR3/4 MLG Transmitter with Analog Output.

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Continuous level measurement Radar transmitters

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Series 3730 Type Electropneumatic Positioner

SFY Functional Safety Frequency-to-DC Transmitter with Display

MODEL: MD7ST. [3] LOOP DISCONNECT FUSE 0: Without 1: With (CENELEC/ATEX approval Not selectable)

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

CURRENT TO PROFIBUS PA CONVERTER

Series 3731 Type Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. WirelessHART components Gateway and accessories

Installation Equipments

YTA Series Temperature Transmitters

Series 3731 Type Electropneumatic Ex d Positioner with HART communication

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12

ERNG-X. Description. Applications. ERNG-X Specifications DERNG2108X012

Rosemount 248 Wireless Temperature Transmitter

WirelessHART Adapter SWA70

ROC800-Series IEC Interface

4110 HART Level Encoder

Temperature process values at a glance

UFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication

Series 3731 TROVIS SAFE Electropneumatic Ex d Positioner

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline

FloBoss 103 Flow Manager

Technical Data. General specifications. Rated operating distance s n 3 mm

Explosion-Proof Gauge Pressure Transmitter

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

TRANSMISSOR DE PRESSÃO PIEZO RESISTIVO INTELIGENTE MICRO PROGRAMÁVEL SÉRIE PAS

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

SRD991 Intelligent Positioner with HART, FoxCom, PROFIBUS-PA, FOUNDATION Fieldbus H1 or Without Communication

Analyze IT Analytical Instruments Two-Wire ph, ORP, plon Transmitters

Installation & Operation Manual

Miniature I/P, E/P Transducer

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM MT-436-TX

Fisher i2p-100 Electro-Pneumatic Transducer

Smart Wireless THUM Adapter

DVC2000 Series FIELDVUE Digital Valve Controllers

3420 Fieldbus Interface Module (FIM) Contents

Load Disconnect Switches and Motor Switches

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety

BLISS ANAND. BA-Series Magnetostrictive Level Transmitter

Technical Information Promonitor NRF560

Installation & Operation Manual

AS-interface Network Card

NELES INTELLIGENT VALVE CONTROLLER, SERIES NDX

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Conveyor Belt Alignment Switches from IDEM

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE PM MT-336-FX

Remote Level Display with Explosion Proof Enclosure

Transcription:

General Specifications Model MLX Loop Powered Process Indicator GS 60A02S01-01E-A The Model MLX Loop-Powered Process Indicator receives DC current signals from electronic transmitters and indicates process measurement values. Standard models are general purpose. STANDARD SPECIFICATIONS FUNCTIONAL SPECIFICATIONS Input: 4-20mA DC 2-wire Voltage Drop: 3.5V at 20mA LCD Display Numerical: Six 7-segment digits Alpha-numerical: Six 14-segment characters Bar graph: 20-segment Bar graph. Symbols: P, SP, T, F, %,, x10, x100, x1000 Configuration: User configurable for desired engineering units. Method: User configurable from front panel Zero & Span: Zero and span can be set between ±999999. Turn-on Time: 12 second (includes power on self-test and memory integrity check) Update Time: 1 second Isolation: Input/Output/Ground isolated to 500V DC PERFORMANCE SPECIFICATIONS Accuracy: ± 0.05% of full scale +1 digit Operating Current: 3.6mA to 28mA Ambient Temperature: -40 to +80 C (-40 to 176 F) Ambient Humidity: 0 to 100%RH at 23 C (73 F) Ambient Temperature Effect: 0.1 C per 10 C Over range: 200mA without damage Maximum error: +0.02%, -0.03% (of full scale) Conformity (Linearity): 0.03% Hysteresis error: 0.03% Repeatability: 0.03% Vibration: 3G @ 10-150Hz Shock: 50G Explosion Protection: FM, CSA, ATEX, and IEC PHYSICAL SPECIFICATIONS Enclosure Material Housing: Low copper cast aluminum alloy with Polyurethane resin baked finish - Deep sea moss green (equivalent of Munsell 0.6GY3.1/2.0) or SUS316 cast stainless steel (ASTM CF-8M) Name plate: Black anodized aluminum or 316 SST Tag: 304 SST Wired tag: 304 SST Degrees of Protection: NEMA 4X, IP67 Mounting: Nominal 2 (50mm) pipe mount or surface. (horizontal or vertical) Weight: 1.25kg (2.70 lbs)* *: Without mounting bracket Add 0.8 kg (0.35 lbs) for mounting bracket Electrical Connection: ½ NPT female or M20 female FEATURES User interface A front panel push button switch combined with four touch switches allows easy configuration of the indicator (calibration, span, zero and engineering units). Root extraction For applications where the process variable is non-linear and based on the square root, 3/2 root or 5/2 root, the MLX can be configured to display the root function of the input. Field Configurable Via the front panel user interface, the process variable parameters can be modified as desired in the field. LCD Display features The LCD display includes a bar graph for an analog indication of the process variable magnitude. The 6 digit display and 6 character display (combined with several symbols) give an instant view of all process variable parameters. A menu system allows customizing parameters such as decimal point position, engineering units, status of symbols and state of bar graph. Self-diagnostics Built-in diagnostics operate at power-up and during operation for ease of maintenance and troubleshooting. EMC Conformity Standard: EN61326-1 Class A, Table 2 (For use in industrial location) Built-in Loop Protection Includes circuitry that, in the event of MLX failure, automatically takes the MLX out of the loop thus maintaining loop integrity. Yokogawa Corporation of America 2 Dart Road, Newnan, GA 30265 800-888-6400 GS 60A02S01-01E-A Copyright September 2017 8 th Edition

MODEL AND SUFFIX CODES Model Suffix Codes Description MLX... Loop Indicator Input signal -A... 4 to 20mA DC Mounting 1... 2 inch Horizontal Pipe Housing 2... 1... 2... Communication -1. Standard Electrical Connection Optional Codes 0.. 2.. 3.. 4.. 5.. 6.. 2 inch Vertical Pipe (or wall mount) Cast aluminum alloy SUS316 cast stainless steel and ASTM CF-8M ANSI ½ - 14NPT female, two electrical connections without blind plug ANSI ½ - 14NPT female, two electrical connections and one 316 SST blind plug ISO M20 x 1.5 female, two electrical connections without blind plug ISO M20 x 1.5 female, two electrical connections and one 316 SST blind plug ISO G1/2 x 14 female, two electrical connections without blind plug ISO G1/2 x 14 female, two electrical connections and one 316 SST blind plug / Optional specification OPTIONAL SPECIFICATIONS (For Explosion Protected Type) FM Explosion-proof/FM Dust-Ignition-Proof Approval Conforms to: FM3600, FM3615, UL 1203 Explosionproof/Dust-Ignition-Proof for Class I, II, III, Division 1 & 2, Groups A G, FF1 Class I, Zone 1, Group IIC T4 Ambient Temperature: 40 to 80 C ( 22 to 176 F) Temperature class: T4 FM Intrinsically Safe/FM Explosion-proof/ FM Dust-Ignition-Proof /FM Non-incendive Approval Conforms to: FM3600, FM3610, FMRC 3611, FM 3615, FM 3616, UL 913, UL 1203, UL 60079-0, UL 60079-11 Intrinsically Safe for Class I, II, III, Division 1 & 2, Groups A - G, Factory Mutual (FM) Zone 20, Class I, Zone 0, AEx ia IIC, T4 Ga 40 C < Ta < 80 C ( 22 to 176 F) Explosion-proof/Dust-Ignition-Proof for Class I, II, III, Division 1 & 2, Groups A - G, Class I, Zone 1, Group IIC T4 Amb. Temp.: 40 to 80 C ( 40 to 176 F) FU1 Non-incendive for Class I, II, III, Division 2, Groups A - D, F, G, Class I, Zone 2, Group IIC T4 Enclosure: "NEMA 4X", Temp. Class: T4, Amb. Temp.: 40 to 80 C ( 40 to 176 F) Intrinsically Safe Apparatus Parameters [Groups A - G] Vmax=28 V, Imax=115 ma, Pmax=0.65 W, Ci=0 nf, Li=0 H Non-Incendive Apparatus Parameters [Groups A - G] Vmax=30 V, Imax=150 ma, Pmax=0.85 W ATEX Intrinsically Safe/ATEX Flameproof/ATEX Non-incendive Approval Applicable Standard: EN 60079-0, EN 60079-1, EN 60079-11, EN 60079-26, EN 60079-31 II 1G Ex ia IIC T4 Ga Entity parameters : Ui=28 V, Ii=115 ma, Pi=0.65 W, Ci=0 nf, Li=0 H II 2G Ex d IIC T4 Gb CENELEC ATEX KU21 II 2D Ex tb IIIC T135 Db II 3G Ex na IIC T4 Gc Entity parameters : Ui=30 V, Ii=150 ma, Pi=0.85 W Degree of protection : IP66 and IP67 Temperature class: T4, Ambient Temperature: 40 to 80 C ( 40 to 176 F) CSA Intrinsically Safe/CSA Explosionproof/ CSA Dust-Ignition-Proof /CSA Non-incendive Approval Certified to: CSA C22.2 No. 25, CSA C22.2 No. 30, CSA C22.2 No. 157, CSA C22.2 No. 213, CSA C22.2 No. 60079-0, CAN/CSA E60079-11 Class I, II, III; Groups A - G; Divisions 1 & 2. Class I, Zone 1, Group IIC T4. Class I, Division 1, II, III; Groups A - G; Divisions 1 & 2. Canadian Standards Zone 20, Class I, Zone 0 Association (CSA) AEx ia IIC T4 CU1 Canadian Standards Association (CSA) Class I, II, III; Groups A - D, F, G; Divisions 2. Class I, Zone 2, Group IIC T4. Enclosure rating: "Type 4X." Temperature Class: T4

OPTIONAL SPECIFICATIONS (For Explosion Protected Type) IECEx Scheme Combination of Approvals IEC Intrinsically Safe/IEC Flameproof/IEC Non-Incendive Approval Applicable Standard: IEC 60079-0:2011, IEC 60079-1:2008, IEC 60079-11:2011, IEC 60079-26:2009, IEC 60079-31:2008 Ex d IIC T4 Gb Ex tb IIIC T135 Db Ex ia IIC T4 Ga SU2 Ex na IIC T4 Gc Enclosure: IP66 and IP67 INMETRO (Brazil) Combination of FU1, CU1 and KU21 Approvals INMETRO Intrinsically Safe/INMETRO Flameproof Approval /INMETRO Non-Incendive Applicable Standard: ABNT IEC 60079-0:2011, ABNT IEC 60079-1:2008, ABNT IEC 60079-11:2011, ABNT IEC 60079-26:2009, ABNT IEC 60079-31:2008 Ex d IIC T4 Gb Ex tb IIIC T135 Db Ex ia IIC T4 Ga Ex na IIC T4 Gc Enclosure: IP66 and IP67 V1U BU1 OPTIONAL SPECIFICATIONS Coating Epoxy resin coating Polyurethane-Epoxy Anti-corrosion coating Note 1 Calibration Calibration range and scale ENG Stainless steel tag plate Paint Stainless steel tag screw attached to housing Stainless steel tag wired to housing Light Blue (RAL # 5012) Orange (RAL # 2008) Red (Munsell # 7.5 R4/14) Mint Green (CC55) Silver (RAL # 9006) Yellow (RAL # 1018) Gray (RAL # 7046) X1 X2 SST SSW P1 P2 P3 P4 P5 P6 P7 ORDERING INFORMATION Specify the following when ordering: 1. Model and suffix codes. 2. Option codes. 3. Tag number 4. Calibration range desired (optional) OPTIONS The MLX is fully field configurable from the front panel. To order a pre-configured unit, specify the /ENG option followed by the desired setpoints (zero, full scale, and engineering units). Example Ordering Information: MLX-A11-10/FF1/ENG/SST (Field Mounted Loop Indicator, 4 to 20mA DC, 2 Horizontal Pipe mount, aluminum housing, standard communication, ANSI ½ NPT electrical connection without blind plugs, FM Explosion-proof approval) 0-200 InH2O Scale in Engineering Units. Please specify Scale and Engineering units when ordering /ENG. FT-201 Specify Tag Number when ordering /SST and/or /SSW.

DIMENSIONS MOUNTING

WIRING The loop powered indicator series is powered by the current loop and does not require external power. All devices must be wired in series with the current loop. Twisted pair shielded cable is recommended. The following is a typical wiring example of the MLX Loop Indicator connected to an EJA Pressure Transmitter (Note: The EJA Transmitter below can be replaced with any 4-20mA 2 wire device. MLX Loop Indicator EJA Transmitter Loop Power Supply + - R Load + - J1 J2 Shorting Bar installed _ + + SUPPLY CHECK The above configuration is easily adaptable for use with a HART Transmitter, as shown below. MLX Loop Indicator HART Transmitter Loop Power Supply + - R Load + - J1 J2 Shorting Bar installed _ + + SUPPLY CHECK