CuteLine AIN8 Temperature. Manual

Similar documents
CuteLine AIN8 UI - Voltage Current. Manual

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

iothinx 4500 Series (45MR) Modules

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL

Warranty. Warning. Copyright. Contact Us

NetBiter I/O Extender User Manual

Submittal Data Sheet WAGO Node for itm

USER MANUAL FOR FIOA-0402-U-16

Installation and Operation Manual. INTEGRA BTU Meter System

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

USER GUIDE PEL / PEL-M

Features and Benefits. Certifications

XT-9100 Technical Bulletin

Installation Manual CCL 20 D PTZ camera controller unit DIN-rail mounting

ETHERNET/MFC 010 Technical Datasheet

UNIVERSAL CURRENT CONVERTER

POWERWISE INDAC SETUP MANUAL

USER GUIDE PEL 8K / PEL 8K-M

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

Safety: UL508 EMC: CE IEC , IEC Vibration: IEC (2 g s during operation) Warranty

Expansion Module HZS 541-1S

PBSCONTROL. AMS-R4000 Modular RTU. Remote Terminal Unit

DIN-rail mountable relay unit for commercial control, power switching and home automation applications

IQ3/XNC M-Bus Master

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

TM3TI4 module TM3-4 inputs temperature

Component identification

Product Specification for SAB-S-MODBUS

8520/8520R. User Manual

GW-7228 J1939/Modbus RTU Slave Gateway

icex-cmtm General specs and Installation guide

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

iologik 4000 Series (M) Modules

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3704, EP GFK-2960B November 2017

PRM Integration Guide with. MTL 4840 Series HART Multiplexer

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

Quick Installation Guide

Manual and Protocol Description

GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

BARIX IO12. I/O to RS-485 Modbus converter for commercial interfacing, control and home automation applications PRO D UCT MANUAL. Version: 2.

VersaMax IP Input Module

Features and Benefits. Certifications

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

PLC PL User Manual

Moxa TCC-100 Series User s Guide

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

Carbon Monoxide Sensor - ModBus

DL-10. User Manual. RS-485 Remote Temperature and Humidity. English Ver. 1.0, Jul. 2017

iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

L-MBUS20/L-MBUS80. User Manual. M-Bus Level Converter. LOYTEC electronics GmbH

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

GFC111-MB. Flow Computer With RS485 MODBUS FEATURES 1. DESCRIPTION APPLICATIONS

H704-42(H)(E), H704-42/1(H)(E)

NGC-40-BRIDGE. Control and Monitoring Modules for use with the nvent Raychem NGC-40 System Installation Instructions

EAZY-CAL LVC-4000 LVDT Signal Conditioner User Manual

PRODUCT FAMILY: SOLO Controllers Number: AN-LC-009

MRUC-20 Modul-R CAN Bus Network

Accessory Modules. Reference Guide. Extension modules for IL-NT, IC-NT, ID-Lite genset or engine controllers, IA-NT. April ComAp, spol. s r.o.

iologik E4200 Modular Active Ethernet I/O adaptor IT and Instrumentation for industry Introduction Specifications LAN Regulatory Approvals Warranty

Instruction Manual. ICENI/MA-01 MODBUS Master Module. Pub_ Issue 1

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

Vorne Industries. Model 77/232 Serial Input Numeric 3" Display User's Manual

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

EX-RC1 Remote I/O Adapter

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664, EP-3704, EP GFK-2960F September 2018

smart meters... 6 panel meters... 7 field displays... 8 display types loop powered displays TRANSMITTERS & CONVERTERS...

Trident and Trident X2 Digital Process and Temperature Panel Meter

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System

Temperature module. 4 inputs for resistance thermometers

KTA-250 Anemometer Alarm Card

SK TU4-IOE-M12-C Part Number

Remote I/O Product Specification

Synergy Controller Application Note 20 April 2008, Revision P4 Tidal Engineering Corporation 2008

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

TM3TI4 module TM3-4 inputs temperature

ASTAT XB/XBm Remote Operator

Temperature module. 4 inputs for thermocouples

M1000 INTELLIGENT ZONE CONTROL SYSTEM

Diagnostics (Logical) Diagnostics (Physical)

is then retained absolutely without interruption.

NGC-40-BRIDGE CONTROL AND MONITORING MODULES FOR USE WITH THE RAYCHEM NGC-40 SYSTEM INSTALLATION INSTRUCTIONS

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

BARIX X8. I/O to RS-485 Modbus converter for commercial interfacing, control and home automation applications. Version: 2.01.

Temperature controller Ducted systems

MLC 9000 Bus Compatible PID

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

MOXA TCC-120/120I User s Guide

TM3TM3 module TM3-2 temperature inputs and 1 analog output

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

Transcription:

CuteLine Manual Doc.-No. : Version : 1.4 Date of Issue : HUEGLI TECH Switzerland This document, and the information contained herein is the intellectual property of HUEGLI TECH. It is to be used only in conjunction with the specific system or the specific equipment for which it was meant, and may not be used for any other purpose. The copyright has been applied to every page. We reserve all rights for this document, also in the event of application for patents or registry of patterns or designs. None of the information contained herein may be disclosed to third parties, nor may it be reproduced, copied or transmitted in any way, shape or form, or by any means, electronic, mechanical, or otherwise, without the prior written permission of HUEGLI TECH. Unless otherwise stated, masculine nouns and pronouns do not refer exclusively to men. All trademarks used in this document are properties of their respective owners.

1 Mounting The CuteLine modules are designed to be mounted on a 35 mm DIN Rail and can be easily attached and detached from the DIN rail. To mount the module on the DIN rail, attached the upper portion of the module onto the DIN rail and press down the module until the hook clicks itself. To remove the module from the DIN rail, simply unhook the lower part using a screwdriver and lift the enclosure from the DIN rail. 2 Electrical Connection All connectors can be pulled out from the board for easier wiring. 2.1 Power Supply The nominal supply input for CuteLine Module is 24 VDC power supply but it can also work from a voltage range of 7-30VDC. The green LED on the front is turned on when the device is connected to the power supply. The supply input is reverse polarity protected. 2.2 Sensor Connection For each of the 8 analogue inputs, Thermocouple type K/J/L, Pt1000 (RTD) or Pt100 (RTD)/NI100 can be connected. If a thermocouple is used the + of it must be connected to AINx+ (for example AIN1+) and the must be connected to the corresponding AINx- (for example AIN1-). Using a 2 wire Pt1000 (RTD) or Pt100 (RTD)/NI100 one wire must be connected to AINx+ (for example AIN4+) and the other wire must be connected to the corresponding AINx- (for example AIN4-). With DIP Switch 1 the type of input is selected. Each of the 8 switches is assigned to the corresponding input. Note: Pt1000 (RTD) sensor type is available on HT-CL-AIN8PT1000 Module Pt100 (RTD) and NI100 sensor types are only available on HT-CL-AIN8T Module Version: 1.4 Manual 2 / 12

If the sensors are connected as in the drawing above, DIP Switch 1 must be configured as follows : SW1:1 SW1:4 ON Note: Unused inputs (AINx+) should be connected to their corresponding pair inputs (AINx-), the corresponding DIP switch must be. Input Selection DIP Switch 1 Thermocouple K, J, L Pt100(RTD) / NI100 Input AIN 1 SW1:1 SW1:1 ON Input AIN 2 SW1:2 SW1:2 ON Input AIN 3 SW1:3 SW1:3 ON Input AIN 4 SW1:4 SW1:4 ON Input AIN 5 SW1:5 SW1:5 ON Input AIN 6 SW1:6 SW1:6 ON Input AIN 7 SW1:7 SW1:7 ON Input AIN 8 SW1:8 SW1:8 ON 3 Serial Connection The CuteLine Module provides two kinds of serial connection: Can Bus RS485 Various Protocols Mod Bus RTU 3.1 Can Bus Connection Using the Can Bus connection, the bus cable must be connected to the terminals Can H(igh) and Can L(ow). If the module is the first or the last device in the bus, a termination resistor is required. There is a build in resistor (120 Ohms) which can be activated by switching SW2:8 to ON position. Shielded cable (for example HELUKABEL CAN BUS 2x0.22) must be used for the CAN Bus connection. Recommended Wiring Version: 1.4 Manual 3 / 12

3.2 Can Bus Connection to IG-NT / IS-NT If the device is connected to IG-NT / IS-NT, the address setting (DIP SW2) in the CuteLine module must be configured to match the setting in the Controller. In the GenConfig, the CuteLine devices should be selected as a Generic Extension -> AI (generic). Address Settings for IG-NT / IS-NT Mode DIP Switch 2 Address SW2:1 SW2:2 SW2:3 SW2:4 SW2:5 SW2:6 SW2:7 1 2 ON 3 ON 4 ON ON 5 ON 6 ON ON 7 ON ON 8 ON ON ON 9 ON 10 ON ON 11 ON ON 12 ON ON ON 13 ON ON 14 ON ON ON 15 ON ON ON 16 ON ON ON ON Any changes on the address settings (switches SW2:1 to SW2:7) are valid only after a Power Down Reset Version: 1.4 Manual 4 / 12

Sensors that can be configured in GenConfig that supports this module include Thermocouple (K, J, L) ( o C/ o F) and Pt1000 (RTD) or Pt100 (RTD)/NI100 ( o C/ o F). 3.3 Can Bus Connection to HT Controller (DST Mode) If the device is connected to HT Controller, the address setting (DIP SW2) in the CuteLine module must be configured to match the setting in the Controller. In the BoardPrg, the CuteLine devices must be selected as DITHERM or DIVIT. The module covers automatic two DITHERM / DIVIT addresses because on one DITHERM / DIVIT address as there are only 3 (DITHERM) or 4 (DIVIT) input channels that are configurable. Note: In DST Model, Yellow LED on the front is blinking when data are sent out. In default mode, the unit for temperature reading of thermocouples type K and Pt100 or Pt1000 (RTD) is in C. Using other sensors see chapter 3.6 Version: 1.4 Manual 5 / 12

Address Settings for DST Mode DIP Switch 2 Address SW2:1 SW2:2 SW2:3 SW2:4 SW2:5 SW2:6 SW2:7 DITHERM #01 + #02 ON DITHERM #03 + #04 ON ON DITHERM #05 + #06 ON ON DITHERM #07 + #08 ON ON ON DITHERM #09 + #10 ON ON DITHERM #11 + #12 ON ON ON DITHERM #13 + #14 ON ON ON DITHERM #15 + #16 ON ON ON ON DIVIT #01 + #02 ON ON DIVIT #03 + #04 ON ON ON DIVIT #05 + #06 ON ON ON DIVIT #07 + #08 ON ON ON ON DIVIT #09 + #10 ON ON ON DIVIT #11 + #12 ON ON ON ON DIVIT #13 + #14 ON ON ON ON DIVIT #15 + #16 ON ON ON ON ON Any changes on the address settings (switches SW2:1 to SW2:7) are valid only after a Power Down Reset Selecting DITHERM Address reads on Inputs 1-3 and 5-7 from the AIN8 Temp 3.4 Can Bus Connection in J1939 Mode In this mode the CuteLine Module provides the possibility to connect it to any controllers which can read the SPN s for single exhaust gas temperatures. In the J1939 protocol for single exhaust gas temperature measurement, each PGN contains the measurement of 4 Cylinders (Cyl. 1 4, Cyl. 5 8 etc.). Since the module has 8 inputs it will transmit the measurements of two PGN s. The only exception is for cylinders 17 20 where only the measurements of AIN 1 to AIN 4 are transmitted. Measurements of AIN 5 to AIN 8 are ignored. Note: In J1939 Mode, Yellow LED on the front is blinking when data are sent out. In default mode, the unit for temperature reading of thermocouples type K and Pt100 or Pt1000 (RTD) is in C. Using other sensors see chapter 3.6 Address Settings for J1939 Mode DIP Switch 2 Address SW2:1 SW2:2 SW2:3 SW2:4 SW2:5 SW2:6 SW2:7 Cylinder #1 to #8 SPN 1137-1144 ON PGN 65187 (FEA3) + PGN 65186 (FEA2) Cylinder #9 to #16 SPN 1145-1152 PGN 65185 (FEA1) + PGN 65184 (FEA0) Cylinder #17 to #20 SPN 1153-1156 PGN 65183 (FE9F) ON ON ON ON Any changes on the address settings (switches SW2:1 to SW2:7) are valid only after a Power Down Reset Version: 1.4 Manual 6 / 12

3.5 Can Bus Connection to IL-NT / IC-NT If the device is connected to IL-NT / IC-NT, the address setting (DIP SW2) in the CuteLine module must be configured to match the setting in the Controller. The four analogue inputs under IOM can be configured as the desired sensor type by loading the corresponding sensor characteristics curve (CRV file). Analogue Input Sensor loading the desired CRV by browsing the destined folder To be configured as Thermocouple K ( o C) and Pt100 or Pt1000 (RTD) ( o C), the ready sensor characteristics curve (CRV file) for these sensors can be downloaded from http://www.huegli-tech.com/. For other type of sensors, the respective sensor characteristics curve must be created by the user accordingly. Note: In this Mode, Yellow LED on the front is blinking when data are sent out. In default mode, the unit for temperature reading of thermocouples type K and Pt100 or Pt1000 (RTD) is in C. Address Setting for IL-NT / LC-NT Mode DIP Switch 2 SW2:1 SW2:2 SW2:3 SW2:4 SW2:5 SW2:6 SW2:7 ON ON ON ON Any changes on the address settings (switches SW2:1 to SW2:7) are valid only after a Power Down Reset When the module is in IL-NT / IC-NT Mode, only inputs 1-4 from the AIN8 Temp can be read in. Version: 1.4 Manual 7 / 12

3.6 Can Bus Connection to IL-NT / IC-NT (Special) If the device is connected to IL-NT / IC-NT using the special mode, the address setting (DIP SW2) in the CuteLine module must be configured to match the setting in the Controller.Under this mode, it is capable of monitoring the temperature sensor up to 6 from CuteLine device though the controller supports only four configurable analog inputs. Among the four analogue inputs under IOM, the first one must be configured as the indication of the display which are currently monitoring since the display is changing between two sets of reading. It can be configured by loading the characteristics curve (CRV file) named AIN8 Temp Indication which can be downloaded from http://www.huegli-tech.com/ Analogue Input Sensor loading AIN8 Temp Indication characteristics curve (CRV file) The other three analogue inputs can be configured as the desired sensor type inputs by loading the corresponding sensor characteristics curve (CRV file). To be configured as Thermocouple K ( o C) and Pt100 or Pt1000 (RTD) ( o C), the ready sensor characteristics curve (CRV file) for these sensors can be downloaded from http://www.huegli-tech.com/. For other type of sensors, the respective sensor characteristics curve must be created by the user accordingly. Note: In this Mode, Yellow LED on the front is blinking when data are sent out. In default mode, the unit for temperature reading of thermocouples type K and Pt100 or Pt1000 (RTD) is in C. Version: 1.4 Manual 8 / 12

Analogue Input Sensor loading the desired CRV by browsing the destined folder Address Setting for IL-NT / LC-NT Mode (Special) DIP Switch 2 SW2:1 SW2:2 SW2:3 SW2:4 SW2:5 SW2:6 SW2:7 ON ON ON Any changes on the address settings (switches SW2:1 to SW2:7) are valid only after a Power Down Reset When the module is in IL-NT / IC-NT (Special) Mode, only inputs 2-4 and 6-8 from the AIN8 Temp can be read in. Display As the display can show only three readings at one time, the reading shown at display is moving to and fro between 1 st set of reading (123) and 2 nd set of reading (456). 1 st set of Reading 2 nd set of Reading Indication 123 Indication 456 1 Input AIN2 4 Input AIN6 2 Input AIN3 5 Input AIN7 3 Input AIN4 6 Input AIN8 Version: 1.4 Manual 9 / 12

3.7 Mod Bus RTU Connection When working in this mode, the CuteLine Module works as a Mod Bus Slave so the Master has to request data from it. The connection must be on the terminals RS485A and RS485B. If the module is the last device in the bus, an external 120 Ohms termination resistor must be added. Recommended Wiring There are fixed object numbers for the 8 analogue inputs : 30001 AIN 1 30002 AIN 2 30003 AIN 3 30004 AIN 4 30005 AIN 5 30006 AIN 6 30007 AIN 7 30008 AIN 8 The Master can read a single or several objects by using the command 04. In standard the scaling for the temperature is in C and only for thermocouples type K and Pt100 or Pt1000 (RTD). Using other sensors see chapter 3.6 The communication settings are 9600 / 19200 Baud (depending on DIP SW2:5), 8 Bit, 1 Stop Bit, No Parity. The yellow LED on the front is blinking when data are sent out after a request from the Master. Version: 1.4 Manual 10 / 12

Address Settings for Mod Bus RTU Mode DIP Switch 2 Address SW2:1 SW2:2 SW2:3 SW2:4 SW2:5 SW2:6 SW2:7 1 * ON Any changes on the address 2 ON * ON settings (switches SW2:1 to 3 ON * ON SW2:7) are valid only after a 4 ON ON * ON 5 ON * ON Power Down Reset 6 ON ON * ON 7 ON ON * ON 8 ON ON ON * ON 9 ON * ON 10 ON ON * ON 11 ON ON * ON 12 ON ON ON * ON 13 ON ON * ON 14 ON ON ON * ON * = Baud Rate Selector 15 ON ON ON * ON = 9600 Baud 16 ON ON ON ON * ON ON = 19200 Baud 3.8 Using other Sensors When using a connection to a HT Controller, J1939 protocol or Mod Bus RTU in standard setup, only thermocouples type K and Pt100 or Pt1000 can be connected to the device. With the software Cute- Line Configuration, the module can be configured to use different sensors like thermocouples type J or NI100. Latest version of the software can be downloaded from http://www.huegli-tech.com/ To start the configuration, switch off the module and set the DIP SW2 to these positions: Connect the PC / Laptop to the module: Launch the software and click on Connect. Select the type of sensor which is connected to the individual inputs and click on OK. If the configuration is successful, you will receive a pop box message to notify you about it. After this is completed, click on Disconnect and turn off the power supply to the module. This completes the sensor type configuration process. To resume the use of the module, put back DIP SW2 to the position of the configuration as needed and follow the instruction to the relevant chapters. Version: 1.4 Manual 11 / 12

4 Technical Data Power Supply... 7-30VDC, Reverse Polarity Protected Current Consumption...35 ma with 24VDC Input @ 25 C Number of Inputs... 8, Differential Sensor Types/Range Thermocouple Type K... 0 ~ 850 C (32 ~ 1562 F) Thermocouple Type J... 0 ~ 620 C (32 ~ 1148 F) Thermocouple Type L... 0 ~ 610 C (32 ~ 1130 F) Pt100 (RTD) #... -100 ~ 300 C (-148 ~ 572 F) NI100 #... -60 ~ 160 C (-76 ~ 320 F) Pt1000 (RTD) *... -100 ~ 300 C (-148 ~ 572 F) Resolution... 1 Accuracy Thermocouple Type K...0.7% of Full Scale @ 25 o C RTD..1.2% of Full Scale @ 25 o C Calibration...Factory Calibrated Communication Supported Protocols...Can Bus IS/IG... Can Bus HT Controller... J1939 Can Bus IC/IL...Can Bus IC/IL (Special)... Mod Bus RTU Operational Temperature...-40 to +85 o C (-40 to +185 o F) Storage Temperature...-40 to +85 o C (-40 to +185 o F) Relative Humidity...5 to 95%, Non-condensing Dimension... 30 x 110 x 94 mm Weight... 190g Wire Size... 22 to 12 AWG Mounting... DIN Rail 35 mm * Pt1000 (RTD) sensor type is available on HT-CL-AIN8PT1000 Module. # Pt100 (RTD)/NI100 sensor types are only available on HT-CL-AIN8T Module. Version: 1.4 Manual 12 / 12