THE VENTILATION AND COOLING OF LONG RAILWAY TUNNELS DURING EQUIPMENT: EXPERIENCES AND CHALLENGES ON THE EXAMPLE OF THE GOTTHARD BASE TUNNEL

Similar documents
Energy Management of the Refrigeration Systems at Zurich Airport. Burkhard Bein. Schaffhausen,

Data Center Energy Savings By the numbers

High Efficient Data Center Cooling

Aquaflair. BREC/F and BCEC/F kw

Improving the climate for data centers

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

Is Data Center Free Cooling Feasible in the Middle East? By Noriel Ong, ASEAN Eng., PMP, ATD, PQP

Introducing the Heat Wheel to the Data Center

A BSRIA Guide. Free Cooling Systems BG 8/2004 FREE COOLING SYSTEMS BSRIA By Tom De Saulles. Supported by

How Green can you go?

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

Technical Concept. Tunnel Air Shower. All Types Air Shower / Air Locks

Energy Engineering: Tools and Trends

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Next Generation Cooling

OPEN FACE Industrial East Grand Ave., Pomona, CA Fax:

ZTE ZXCR Series DX In-Row Air Conditioning Product Description

Second Stakeholder Meeting for Nonresidential HVAC Proposals Based on ASHRAE Revisions to Waterside Economizer

Designing Ultra-Efficient Building Cooling Systems

Data center cooling evolution. The hottest way to save energy. Lucio Bustaffa: Product Development Manager BlueBox Group

Indirect Adiabatic and Evaporative Data Centre Cooling

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD

DDDM 45 (40-60 TPH) DDDM 60 ( TPH) COLD AGGREGATE FEEDER. Auxiliary belt No. of bins. Gathering conveyor reduction gear

Motivair MLC-SC Air-Cooled Scroll Chillers Tons

Trane Engineering News Chiller Plant Case Study: Variable-Primary Flow Series Chillers with Free Cooling

MEASURE MONITOR UNDERSTAND

Planning a Green Datacenter

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

IN-DEPTH UNDERSTANDING OF HVAC EQUIPMENT & SYSTEM SPECIFICATIONS AND PERFORMANCE 11 & 12 JULY 2016 WISMA IEM

Excellent location for Data Center Campus in Hanko

Industry leading low energy evaporative fresh air cooling.

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

World Leaders in Mine Ventilation and Cooling Systems

AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

Efficiency of Data Center cooling

Indirect Adiabatic and Evaporative Data Center Cooling

Next Generation DCP Optimization using MV VSDs

AVANTAGE DATA CENTER. The only ecological «green» data center in Russia with application of the best innovative technologies

Thermal management. Thermal management

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

Engineered Energy Solutions An Overview. Controls, Automation and Energy Conservation

IXcellerate Moscow One Datacentre - Phase 1 & 2 Overview

Energy Saving in Cleanrooms

Excool Indirect Adiabatic and Evaporative Data Centre Cooling World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

Variable Speed DC Compressors

ecoenergy Innovation Initiative Research and Development Component Public Report

Present implementation: Condensing units, proces chillers (LT, MT) and professional storage cabinets. Per Henrik Pedersen

District Cooling Marches on in Dubai The Emirates Towers Case Study

Ecotel Free Cool 5-15kW

Energy-efficient heating, ventilation and air-conditioning Technologies for certified buildings

ASHRAE Data Center Standards: An Overview

InPac 600 Series Fully configurable severe duty and explosion proof HVAC and building pressurization systems 2 5 ton ::

Operation Guide CT100

DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書

Denton Vacuum Phoenix 400 Continuous In-Line Sputtering Deposition System General Specifications

Rack cooling solutions for high density racks management, from 10 to 75 kw

CTC Low Temperature Process Chillers

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

CUTTING-EDGE TECHNOLOGY MINING ENERGY INFRASTRUCTURE

The Platform for Productivity

CASE STUDIES ENERGY EFFICIENT DATA CENTRES

Why would you want to use outdoor air for data center cooling?

Variable Speed DC Compressors and Condensing Units

Impact of Air Containment Systems

ENCLOSURE HEAT DISSIPATION

Cooling Solutions & Considerations for High Performance Computers

Green Data Centers A Guideline

DATA CENTRE. JT First Tower Lane. Facility Product Description. Data Centre Services

New Wisconsin Energy Code: What it Means for Me?

Taking The Heat Off University of East Anglia Data Centre

Saving Energy with Free Cooling and How Well It Works

Airedale International Air Conditioning Limited. Leeds Road, Rawdon Leeds, LS19 6JY, England

SCHENDT ENGINEERING PRIOR EXPERIENCE

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet

TWO FINANCIAL IMPACT STUDIES. Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

DATA CENTRE. JT Five Oaks. Facility Product Description. Data Centre Services

Zurich West Data Center

White paper adaptive IT infrastructures

HVAC Project. Comparison of Revit MEP Automatic Duct Sizing and Equal Friction Method Manual Calculations

Technical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC

APC InRow Cooler Prototype Initial Report - Test Setup Verification. H. Coles, S. Greenberg Contributing: J. Bean (APC) November 18, 2011

Notes U695. (1) Vehicle power supply must meet the normal operating voltage, such as

Fast Route to Reliable Energy Savings ZIP Economizer

Reducing Energy Consumption with

FLEX Implementation. Roy Harter RLH Global Services. SAMG-D course, IAEA, Vienna, Austria October

Fair City Plaza. Task: Diagnose problems, recommend improvements for small municipal district cooling system

DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency

WHAT IS THE DIGI-RTU South 59 th Street Omaha, NE bes-tech.net

STATE DATA CENTER DRAFT PROPOSAL. STATE OF OREGON DATA CENTER 28 October 2016

STATEMENT. (2) PS701 is just offered for the professional and technical personnel of vehicle maintenance

How To Draw Chiller Monsters Werewolves Vampires And Zombies

Datasheet.

MSYS 4480 AC Systems Winter 2015

i-accurate_gb_ High precision air-conditioners for data centres cooling, with new inverter technology and R-410A refrigerant, from 6 to 150 kw

Transcription:

THE VENTILATION AND COOLING OF LONG RAILWAY TUNNELS DURING EQUIPMENT: EXPERIENCES AND CHALLENGES ON THE EXAMPLE OF THE GOTTHARD BASE TUNNEL Samuel Gehrig 8th International Conference Tunnel Safety & Ventilation, Graz, 2016 April 25 th 2016

CONTENT AND INTRODUCTION THE VENTILATION AND COOLING OF LONG RAILWAY TUNNELS DURING EQUIPMENT: EXPERIENCES AND CHALLENGES ON THE EXAMPLE OF THE GOTTHARD BASE TUNNEL Introduction The tunnel The boundary conditions The requirements The ventilation system The cooling system Experiences and challenges Conclusion THE VENTILATION AND COOLING OF LONG RAILWAY TUNNELS DURING EQUIPMENT 2

THE TUNNEL Courtesy of ATG THE VENTILATION AND COOLING OF LONG RAILWAY TUNNELS DURING EQUIPMENT 3

THE BOUNDARY CONDITIONS AND INTERFACES (1) The equipment work Courtesy of THE VENTILATION AND COOLING OF LONG RAILWAY TUNNELS DURING EQUIPMENT 4

THE BOUNDARY CONDITIONS AND INTERFACES (2) The machines deployed Diesel engines only, with very strict requirements: EU guideline 2004/26, status June 2004, oxidising catalyst for CO and HC, selective catalytic reduction system for NOx and a particle filter. General equipment procedure: 1. temporary installations, power and com-munication cables, using tyred vehicles. 2. slab track (the most power consuming process) using a rail train, a sleeper train, 450 m long concrete carrier train, and several smaller diesel driven machines assisting the trains (e.g. welding machine, concrete shuttles, etc.). Cf. picture. 3. installation of the remaining systems, such as the catenary, using trains driven with smaller locomotives and rail cars. Courtesy of THE VENTILATION AND COOLING OF LONG RAILWAY TUNNELS DURING EQUIPMENT 5

THE BOUNDARY CONDITIONS AND INTERFACES (3) The Heat sources Heat sources: Rock: up to 11.0 MWth per tube Machines: up to 1.7 MWth per tube Curing concrete: up to 0.4 MWth per tube THE VENTILATION AND COOLING OF LONG RAILWAY TUNNELS DURING EQUIPMENT 6

THE REQUIREMENTS TO VENTILATION AND COOLING Fresh air quantities compliant to SIA 196: Fresh air for transports: 2 m 3 /(minute, Diesel kw), Fresh air for heavy duty stationary engines: 4 m 3 /(minute, Diesel kw). Air velocity in the tubes within a working band of 0.3 m/s to 5 m/s: Consequence: Air volume flow in the tubes limited to 200 m 3 /s. Corresponding to 6 000 Diesel kw per ventilation line. Climatic goal at design: 28 C dry-bulb temperature in the working section Climatic goal during operation compliant with SUVA guidelines: No limit on the type of activity up to 28 WBGT. Only light works permitted between 28 to 30 WBGT. No work allowed above 30 WBGT. Other requirements: Monitoring of flow, climate and air quality. Re-use of ventilation and cooling systems of previous contractors. THE VENTILATION AND COOLING OF LONG RAILWAY TUNNELS DURING EQUIPMENT 7

THE VENTILATION SYSTEM Erstfeld Amsteg MFS Sedrun MFS Faido Bodio 120 m 3 /s 85 m3/s east tube west tube incoming air exhaust air gate air lock ( ) + lane change gate, door fan exhaust airways PLN_20160128_pictures-paper-LP21_GSA.vsd / LK03a Erstfeld Amsteg MFS Sedrun MFS Faido Bodio 200 m 3 /s 200 m 3 /s east tube 200 m 3 /s 100 m 3 /s west tube incoming air exhaust air gate air lock ( ) + lane change gate, door fan exhaust airways 100 m 3 /s PLN_20160128_pictures-paper-LP21_GSA.vsd / LK05 THE VENTILATION AND COOLING OF LONG RAILWAY TUNNELS DURING EQUIPMENT 8

THE COOLING SYSTEM Parameter Cooling GBT north Cooling GBT south Max. requested refrigeration capacity in tunnel, MW 8.4 11.8 Max. requested cooling capacity in tunnel, MW 11.4 16.0 Cooling capacity available at cooling plant, MW 11.4 21.0 Pump capacity available at cooling plant, m 3 /h 800 1 120 Max. number of MACs includable (net refrig. capacity 420 MW each) 20 28 Erstfeld Amsteg MFS Sedrun MFS Faido Bodio north center east tube south west tube cooling GBT north cooling GBT south cooling water pipes (feed and return) pump station heat exchanger mine air cooler (MAC) industrial water pipe cooling plant pressure exchange system P LN_20160128_pictures-paper-LP21_GS A.vsd THE VENTILATION AND COOLING OF LONG RAILWAY TUNNELS DURING EQUIPMENT 9

EXPERIENCES AND CHALLENGES (1) High coordination effort Integration of permanent equipment into temporary ventilation Integration of permanent equipment into the temporary ventilation Integrate permanent ventilation elements into the temporary ventilation where available in order to reduce additional maintenance and avoid the installation of parallel temporary systems. E.g. ventilation of cross connections, cf. picture. High coordination effort: 45 lots within and outside Transtec, needing at least an interface check to the lot ventilation / cooling 24 lots with interfaces identified. Coordination in time and space necessary. Coordination efforts amount to about ½ of total planning time. THE VENTILATION AND COOLING OF LONG RAILWAY TUNNELS DURING EQUIPMENT 10

EXPERIENCES AND CHALLENGES (2) Ventilation supports cooling Sizing of the ventilation according to SIA 196. Monitoring of pollutants concentrations during operation. Concentrations far below OEL most of the time. But: High volume flow rate strongly supports cooling of the tunnel. Courtesy of THE VENTILATION AND COOLING OF LONG RAILWAY TUNNELS DURING EQUIPMENT 11

EXPERIENCES AND CHALLENGES (3) Sizing of the cooling Climatic conditions during transition periods Sizing of the cooling: Designed for 28 C dry-bulb temperature, on the assumption of frequent relative humidity at 100%. Operated following the WBGT-index. As tunnel is sealed against water seepage, humidity is low in the central section, about 30% rh. Consequence: Cooling oversized. Climatic conditions during transition periods loss of control on the air flows or no cooling available consequence: unavoidable local overheating Courtesy of THE VENTILATION AND COOLING OF LONG RAILWAY TUNNELS DURING EQUIPMENT 12

EXPERIENCES AND CHALLENGES (4) Design of cooling water cycle Cooling GBT South: open water cycle high corrosion Cooling GBT North: closed water cycle low corrosion Cooling GBT North Cooling GBT South THE VENTILATION AND COOLING OF LONG RAILWAY TUNNELS DURING EQUIPMENT 13

EXPERIENCES AND CHALLENGES (5) Alternative cooling concept Present solution Future alternative 15-20 C above below ground Mine Air Cooler n times 1-4 C primary cycle refrigeration plant above below ground secondary cycle pump station fan PLN_20160128_pictures-paper-LP21_GSA.vsd / Alternativen compressor throttle water pipes (feed and return) refrigerant cycle air flow heat exchanger, condensor, evaporator cooling plant, open cooling tower THE VENTILATION AND COOLING OF LONG RAILWAY TUNNELS DURING EQUIPMENT 14

CONCLUSION Past: The systems devised and used fulfilled the requirements and were capable to adapt to an environment with parallel running processes. Present: Solid know-how for the ventilation and cooling of long railway tunnels during equipment by experiences made and challenges encountered. Future: Brenner Base Tunnel and Lyon-Turin can profit from this know-how. THE VENTILATION AND COOLING OF LONG RAILWAY TUNNELS DURING EQUIPMENT 15

Consulting. Engineering. Projects. Operations. www.poyry.com

BIBLIOGRAPHY 1) VERT-Filterliste, Geprüfte und erprobte Partikelfilter-Systeme für die Nachrüstung von Dieselmotoren, Bundesamt für Umwelt, Wald und Landschaft (BUWAL), Bern, Dezember 2005 2) Schweizerischer Ingenieur- und Architekten-Verein, SIA 196, Baulüftung im Untertagebau, Zürich, 1998 3) SUVA, Schweizerische Unfallversicherungsanstalt, Abteilung Arbeitsmedizin, Arbeitsmedizinische Prophylaxe bei Arbeiten im Untertagebau im feuchtwarmen Klima, März 2003, Bestellnr. 2869/26.d THE VENTILATION AND COOLING OF LONG RAILWAY TUNNELS DURING EQUIPMENT 17