Universal counter UZ 9648 Counting - length measurement - metering - positioning

Similar documents
Setpoint adjuster SG 9648 Output standard signals 0/ ma or 0/ V DC

Standard-Signal-Panelmeter S 9648 Industry standard signals - integrated transmitter-supply - potentiometer

Speed indicator DR 1010 Revolution per minute - speed - flow

Tank-Display TA 1010 Content measurement for different formed tanks by hydrostatic pressure or distance measurement Features

Setpoint adjuster SG 1010 Output standard signals 0/ ma or 0/ V DC

Standard Signal Meter S 1010

Conductivity-Panelmeter LF 9648 Conductivity measurement with 2-and 4-electrode cells

Measuring Amplifier DMS 50 Weight - Force - Pressure - Torque with strain gauges

Pressure-Converter UNICON -P Differential pressure - diminished pressure - overpressure - barometric pressure - flow rate Features

Safety Temperature Limiter TT-STL 50

Amplifiers, Counters, Timers & Controls

SSR - Supplies - Relays

Temperature-Guard TG 50 Pt100/Pt Thermocouple J, K, N, S

Tachometers TC-4B-V TC-6A-V Electronic cam-operated switching devices FC-21-V... 50

02/11/2015

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

Process displays For current and voltage

02/11/2015

LAUREL ELECTRONICS, INC.

LAUREL. MAGNA Series Large Digit Displays for Counter / Totalizer Pulse Input ELECTRONICS, INC. Features. Description

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

Controller. Applications. Characteristics. Extruder machines Heating control systems Facility engineering Wide range of instrumentation

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

02/11/2015

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

Counting On Your Process Preset Counters

Displays Transducers. Displays and transducers

DIGITAL DISPLAY. for Industry Applications. Series WAY-D. Key-Features:

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

DIGITAL DISPLAY. for Industry Applications. Serie REX-D. Key-Features:

FACTORY AUTOMATION. Manual Speed Monitor KFU8-DW-1.D

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

Contact protection relay

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

Geräte-Handbuch Device manual Notice pour utilisateurs

Electronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Safety Relay F 121 Emergency-Stop Relay, Safety Gate Monitor

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs

Assembly. Front view. LED yellow: Relay output I. LED yellow: Relay output II

G60 SERIES ELECTRONIC PRESET COUNTER ESC P1 / P2 SHIFT RESET ENT

JUMO Quantum PID100/PID200/PID300

English. Operating manual. Limit switch GS125. Keep for future reference. Ventures / brands of GHM

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Peak/Valley Hold Unit (PVHU) User Manual V3.00

Introduction. Features. Index

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

mxcontrol Multifunction Controller

Your process requires the utmost attention Our new ACT20C signal conditioners support you in achieving this

Display and Monitoing Units

Operating Instructions

KTC. Preset Counter/ Timer. Programmable Type. Model Number Legend SALIENT FEATURES. Sensing. Digital Panel Meters

Electronic timer CT-AHD.22

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

FLOW MONITOR & TRANSMITTER

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

Zelio Count - Counters RC87610

DINALOG A 144 x 36 A1400 Light-Strip Indicator

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

Electronic timer CT-ERD.12

Absolute Encoders Multiturn

LAUREL ELECTRONICS, INC.

Phase loss monitor CM-PBE Phasemonitor for over and undervoltage CM-PVE Ordering details

Operating instructions. Standstill monitor A / / 2011

Alarm Unit DG 3200 Control And Monitor Standard Signals

adjustment via factory default or directly on the sensor signal display flashing at threshold undercut or /exceedance

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

signo 727 SSI operating instructions

Supply voltage. Input current. Encoder supply. Memory SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA,

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

VariTrans P Standard-Signal Isolators

Technical specifications

PGR-3200 MANUAL INSULATION MONITOR

Supply voltage. Input current. Encoder supply. Memory

LAUREL. Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 ELECTRONICS, INC. Features. Description

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

Contents. Temperature & Process Measurement Indicators Setup Guide

signo 727 SSI Operating Instructions Position-Indicator with/without limit values and SSI input from absolute encoder

Rotary Measurement Technology Absolute Encoders, Singleturn

02/11/2015

DRTS 33. The new generation of advanced three phase relay test set

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

S-Line HIGH BRIGHTNESS AND ACCURACY DIGITAL LED INDICATORS MODULAR INDICATORS / TOTALIZERS WITH UNIVERSAL ANALOG INPUT

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

VariTrans A The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply.

Transcription:

+49-(0)40-670 73-0 Fax +49-(0)40-670 73-288 info@martens-elektronik.de www.ghm-messtechnik.de Universal counter UZ 9648 Counting - length measurement - metering - positioning Features M LED-Display 14.2mm red M Display range -99999... 999999 M 0... 3 Decimal points programmable M Up- and down counter function M 2 digital inputs channel for summation and subtraction M Integrated transmitter-supply 24/8 V DC M Auto-reset or external reset M Max. 4 alarm outputs, relay SPDT M Display conversion programmable M Isolated analog output 0/4... 20 ma and 0/2... 10 V DC M Front Protection IP65 DIN 96x48 mm General The universal counter UZ9648 has been designed for field application in process control and automation. Parameters for operation mode can be programmed. The counter can be used wherever quantity processes should be measured, displayed and monitored. Short information Programming Transmitter-supply Input prescaler Display conversion Alarm (Preset) outputs Analog output Parameters are programmed via front-side membrane keypad The integrated transmitter supply allows direct connection of pnp initiators, light barriers, mechanical switch contacts, proximity switches, rotary encoder (24 V DC) and Namur initiators (8 V DC). Separate programmable prescaler for input channels. Programmable divisor and factor makes the display adaptable for measuring applications, e.g. flow, length etc.. Alarm outputs can be programmed as continuous contact or pulse contact. Switching performance is programmable as minimum or maximum function. Proportional to the display value an isolated analog output signal 0... 20 ma/0... 10 V DC or 4... 20 ma/2... 10 V DC can be generated. Start value and end value are prorammable. Output changes automatically from current signal to voltage signal, depending on burden. - 1 -

+49-(0)40-670 73-0 Fax +49-(0)40-670 73-288 info@martens-elektronik.de www.ghm-messtechnik.de Technical data Power supply Supply voltage : 230 V AC ±10 %; 115 V AC ±10 %; 24 V AC ±10 % or 24 V DC ±15 % Power consumption : max. 3.5 VA, with analog output 5 VA Operating temperature : -10... +55 C Standard Rated voltage : 250 V AC acc. to VDE 0110 between input/output/supply voltage, degree of pollution 2, over-voltage category III Test voltage : 4 kv DC, between input/output/supply voltage - conformity : EN55022, EN60555, IEC61000-4-3/4/5/11/13 Input pnp-input : Ri = 6.3 kω switching level: < 4 V low; > 8.5 V high; hysteresis > 2.5 V, max. 35 V DC Namur input : Ri appr. 1 kω (< 4 ma) switching level: < 1 ma low; >2.2 ma high; hysteresis > 0.5 ma max. 35 V DC Counting frequence max. : Input A or B = 15 khz, A and B together = 6 khz, switch contact = 30 Hz debounced, 2-channel rotary pulse generator = 8 khz; Counting delay : 100 μs when reset; 20 ms when programming another preselection Min. pulse width : electronic pulse 50 μs, switch contact 5 ms External reset : min. pulse width 10 ms Transmitter-supply : 8 V DC controlled (Namur), 24 V DC (pnp), Ri approx. 150 Ω, max. 50 ma (25 ma with 4 Relais outputs) Display : LED red, 14.2 mm Indicating range : -99999... 999999 digit with leading zero suppression Additional display : LED 2-digit red, 7mm (parameter - and output indicator) Output Relay : SPDT < 250 V AC < 250 VA < 2 A, < 300 V DC < 50 W < 2 A Transistor : max. 35 V AC/DC, 100 ma, with short circuit protection Analog output : 0/4... 20 ma burden 500 Ω; 0/2... 10V burden >500 Ω, isolated Automatic output changing (burden dependent) -Accuracy : 0.1 %; TK 0.01 %/K Case : Panel case DIN 96x48 mm, material PA6-GF; UL94V-0 Dimensions : Front 96x48 mm, mounting depth 100 mm, Weight : max. 390 g Electrical connection : Clamp terminals, 2 mm² single wire, 1,5 mm² flexible wire, AWG14 Protection : Front IP65, terminals IP20, finger safe acc. German BGV A3 Dimension Seal Position terminal strips Panel cut-out acc. to DIN 43700-96x48-2 -

Connection diagrams Terminal strip A 2-channel rotary encoder (ext. supply) PNP-Initiator, rotary encoder (24 V DC) Namur- Initiator (8 V DC) Switchingcontact Input A Input B Gnd Reset count lock /stop Terminal strip B (varies with version) 2 alarm outputs Relay Transistor 24 V/8 V max. 50 ma Transmittersupply Terminal strip C (varies with version) 2 alarm outputs Analog output Relay Transistor AO Terminal strip D supply voltage (varies with version) - 3 -

+49-(0)40-670 73-0 Fax +49-(0)40-670 73-288 info@martens-elektronik.de www.ghm-messtechnik.de Controls and indicators Process value Field for additional text Parameter display or activated alarm (preset) outputs Unit-field Parameter button Down button Up button. For se- Descriptions Operating of the device is arranged in 2 levels. The requested parameter can be called by button lections within a parameter or for entering data, use buttons and. Button combinations: + + sets counting value back to the start value (). + 1 parameter back. + sets parameter to zero or minimum value. After power-on, the device is located in the Working level. Set points of alarm outputs can be programmed if available. Pressing the button for more than 2 seconds, activates the Configuration level. Now all the parameters which define the function of the device can be programmed. These are measuring input, input configuration, display conversion and switching performance of the alarm outputs and analog output. After finishing the configuration or when longer than 2 minutes no button was pushed, the program jumps back to the working level. Leaving the configuration level is possible at any time when pushing the button. Error codes: Reading this symbol in the parameter display a parameter failure has been occurred. The display flashes. When pushing one of the buttons the error code will be deleted and the device is running with factory programmed parameters. Configuration and function of the device must be checked. If the error occurs again, please ship the device to factory for repair service. Programming lock active see page 9 Overflow see page 11 Start-up note: The device has to be configured, before it can be used (see page 6). - 4 -

Notes to representation Parameter is only displayed when configurated Parameter is only displayed when feature is included (see order code) Please Note: All parameters can be called if they are not blocked by other programmed parameters and if they are available. Factory settings are shown in the display. Working level Button Display Description Count value Output indication (only if installed and activated). Setpoint output A1 Setting possible from... digit with buttons and. Setpoint output A2 Setting possible from... digit with buttons and. Setpoint output A3 Setting possible from... digit with buttons and. Setpoint output A4 Setting possible from... digit with buttons and. - 5 -

+49-(0)40-670 73-0 Fax +49-(0)40-670 73-288 info@martens-elektronik.de www.ghm-messtechnik.de Configuration Button Display Description (Display graphic shows factory settings) Press 2s Working level 1 2 Function: input configuration A and B; count direction = A up, B down = A up, B down, for switching contacts = A up, B up = A up, B up, for switching contacts = rotary encoder Prescaler input A Setting possible from... digit with buttons and. (Only every n th pulse is counted) 3 Prescaler input B Setting possible from... digit with buttons and. (Only every n th pulse is counted) 4 Transmitter supply/input level = 24 V DC for pnp-proximity switch = 8 V DC for Namur-proximity switch* (*with ext. 5 V supply also suitable for TTL signals) = only for factory settings. 5 Count value at Power-on = loads start value () (see page 7) = count value is stored if power fails 6 Number of decimal places Continue page 7-6 -

Button Display Description (Display graphic shows factory settings) 7 Divisor for display Setting possible from... digit, with buttons and. also see page 11 8 Factor for display Setting possible from... digit, with buttons and. also see page 11 9 Start value Count value after reset. Setting possible from... Digit with buttons and. 10 End value : the counter operates as totalizing counter in the full range range. When reaching the value or, the counter stops. In the case of overflow the display flashes. : the counter operates as ring counter between start value and end value (see following parameter). 11 Count value for internal reset Setting possible from... digit with buttons and. Continue page 8-7 -

+49-(0)40-670 73-0 Fax +49-(0)40-670 73-288 info@martens-elektronik.de www.ghm-messtechnik.de Button Display Description (Display graphic shows factory settings) 12 Switching performance alarm (preset) output A1 = no output (min) = continuous contact: on-off (max) = continuous contact: off-on = pulse contact: off-on-off = pulse contact: on-off-on 13 Setpoint output A1 Setting possible from... digit, with buttons and. 14 Switching time output A1 [sec]. Setting possible from... s, with buttons and. 15 Switching performance alarm (preset) output A2 = no output (min) = continuous contact: on-off (max) = continuous contact: off-on = pulse contact: off-on-off = pulse contact: on-off-on 16 Setpoint output A2 Setting possible from... digit, with buttons and. 17 Switching time output A2 [sec]. Setting possible from... s, with buttons and. Note: The parameter settings for A3... A4 have to be configured in the same way. Continue page 9-8 -

Button Display Description (Display graphic shows factory settings) 18 Analog output ma (0-10 V DC) ma (2-10 V DC) The switch-over from current to voltage output is load dependent ( 500 Ω = current output, > 500 Ω = voltage output). 19 Start value for analog output Setting possible from... Digit with buttons and. 20 End value for analog output Setting possible from... digit with buttons and. If the start value > end value, the output works with decreasing characteristic. 21 Parameter lock = no lock = configuration level locked = all parameters locked = only with analog output ( only for factory settings) Return to the working level (count value) - 9 -

+49-(0)40-670 73-0 Fax +49-(0)40-670 73-288 info@martens-elektronik.de www.ghm-messtechnik.de Linear counter This counter can operate in the full range from -99999 up to 999999. Counting can start from any start value. Depending on up or down counter function the count value will increase or decrease. Maximum 2 alarm (preset) outputs can be activated either as continous or pulse contact. Reset to the start value only with external reset. Example Start value (after Reset) subtraction count wise addition count wise Counter stops max. count range Counter stops Ring counter This counter operates in the range between start () and end value (. ) or reverse. The procedure repeats regularly unless the counting direction is reversed. Depending on the counting mode, the count value goes back from end value to start value or from start value to end value. 0 and 360 are identical in a circle. The start value and the end value coincide in the ring count mode. Example End value 360 Start value 0 (without reset, too) subtraction count wise addition count wise - 10 -

Display conversion With certain settings of a divisor ( ) and factor ( ) it is possible that the counter does not work in the full range (0... 999999). The relationship is as following: 8 x 10 6 x factor ( ) Maximum display range = divisor () should be > 999999 If the calculated value is less than 999999, the maximal counter value stops at this value. This can be avoided with the prescaler respectively Example: The flow rate in a measuring system shall be measured in m³ and displayed without decimal places. The sensor generates every 0.084m³ one pulse. For programming of the display conversion, the sensor constant has to be converted to a fraction first. Therefor It follows: Factor ( ) = 84 Sensor constant = Divisor () = 1000 Please set for factor = 84 and for divisor = 1000. The check of the maximum display range shows: 8 x 10 6 x 84 Maximum display range = 1000 = 672000 This means, the counter can display maximum up to 672000 m³, when the counting stops. If this is insufficient, part of the divisors can be applied to prescaler or respectively. In this example if divisor was reduced to 500, the maximum display range is > 999999 and full capacity of the counter will be reached. The procedure is as following: Set the divisor to 500, the prescaler respectively (depending to the input) to 2. The calculated value:: 8 x 10 6 x 84 Maximum display range = 500 = 1344000 This provides an optimum configuration for the current example. - 11 -

+49-(0)40-670 73-0 Fax +49-(0)40-670 73-288 info@martens-elektronik.de www.ghm-messtechnik.de Ordering code UZ9648-1. - 2. - 3. - 4. - 5. - 6. - 7. 1. Terminal strip A 1 2 configurable counting inputs, extensive counting functions, integrated transmitter-supply, programmable display conversion, reset input 2. Terminal strip B 00 not installed 2R 2 alarm outputs 2T 2 alarm outputs 3. Terminal strip C 00 not installed 2R 2 alarm outputs 2T 2 alarm outputs AO Analog output relay transistor relay transistor 0/4... 20 ma or 0/2... 10 V DC isolated 4. Terminal strip D supply voltage 0 230 V AC ± 10 % 50-60 Hz 1 115 V AC ± 10 % 50-60 Hz 4 24 V AC ± 10 % 50-60 Hz 5 24 V DC ± 15 % 5. Option 00 without option 6. Unit (on the panel front) 7. Additional text (on the additional text field on the panelmeter, maximum 3 x 90mm WxH ) - 12-10/04-V1.6-00