Add-on Residual Current Protection PBSM MW

Similar documents
Residual Current Devices drcm Digital

Combined RCD/MCB Devices FRBmM, 1+N-pole

Residual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008

Table of Contents Protective Devices / Components

Residual Current Devices FRCdM Type B, B+ and Bfq Digital

Residual Current Devices FRCdM Type B, B+ and Bfq Digital

MCB. Elegance and precision engineering in the same breath. Range : upto 63Amps. Available in SP, SPN, DP, TP, TPN & FP version also Designed by HPL

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

Product Guide. UL 489 DIN rail miniature circuit breakers

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

W DATA SHEET: RCBO COMBINED MCB AND RCCB SERIES BOLF 1+N

DSE201, DSE201 M Compact design with enhanced protection

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

Digital Switchgear Communication at Eye Level planb.eu

Miniature Circuit Breakers for Railway Applications

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

MINIATURE CIRCUIT BREAKERS LPN UP TO 63 A (10 ka)

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

Jtec 10kA Miniature Circuit Breaker

AThink future. Switch to green. MCCB Panel Boards 400A / 630A / 800A.

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation

E-STOP relays, safety gate monitors

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

1492-SP Supplementary Protectors

60103 Circuit Breaker

CS8 Industrial Control Relays

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

Allen-Bradley 1492-RCDA4A40

E-STOP relays, safety gate monitors

Surge Protection Devices Ex9UE2

Residual Current Protective Devices / Arc Fault Detection Devices

Motor protection circuit breakers

E-STOP relay, safety gate monitor

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

Datasheet SRB301ST 24V (V.2)

Datasheet - SRB 402EM-24V

Power consumption In operation At rest For wire sizing

SR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories

Circuit Breakers Type CTI 25M, CTI 45MB

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

VAL-CP-3S-350. Extract from the online catalog. Order No.:

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

Miniature Circuit-Breaker IEC Series 8562

QUINT-PS/ 1AC/24DC/ 5

5SL Miniature Circuit Breakers

VAL-CP-1S-175. Extract from the online catalog. Order No.:

xeffect - Industrial Switchgear Range

Product Guide. UL 1077 DIN Rail Supplementary Protectors

Datasheet - SRB 301LC/B-24V

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

Miniaturecircuitbreaker(MCB),16A,3p,B-Char,AC. Application Switchgear for industrial and advanced commercial applications.

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

RESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka)

For Sales and Support call KMParts.com (866)

Section 4 Ground-Fault Protection Devices

Miniature Circuit Breakers and Supplementary Protectors. Contents

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

Disconnect Switches. Safe Switching and Disconnecting

Horizontal distribution busbar HX 3 80/125 A plug-in

Application Instantaneous release response current 5-10 x In. Switching capacity Switching Capacity 15 ka (IEC/EN ) U e V AC 230/400

xef xe f f ec f t - Industrial Sw S itc it hgea ge r Range Catalog alo ue 2017

E-STOP relays, safety gate monitors

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

ic60n RCBO 30 ma IEC , IEC , AS/NZS

Supplementary Circuit Protectors Type GSB63

SITOP in the SIMATIC Design

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

TT-2-PE-M-24DC. Extract from the online catalog. Order No.:

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

E-STOP relays, safety gate monitors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Overvoltage Protection Devices

RCDs RCBOs MCBs Isolating Switches Switchboards

PT 3-PB-ST. Extract from the online catalog. Order No.:

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)

xef xe f f ec f t - Industrial Sw S itc it hgea ge r Range Catalog alo ue 2018

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)

Extract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards

Safe timer relay/contact expansion modules

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

mcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches

Transcription:

SG_Bestell_MV_E.qxd 25.04.2005 09:39 Seite 36 Add-on Residual Current Protection PBSM MW By combining this device with a top-quality miniature circuit breaker of type PLS. (except PLSN) a top-quality RCBO unit (combined RCD/MCB device) is formed. Draw-out connection bar locked in installation position For subsequent mounting onto 2-, 3-, 3+N- and miniature circuit breakers PLS. Rated current 40 and 63 A WA_SG11902 36

SG_Bestell_MV_E.qxd 25.04.2005 09:39 Seite 37 Add-on Residual Current Protection Unit PBSM conditionally surge-current-proof 250 A, type AC MW Max. nominal current of PLS./I n (A) ype designation Article-No. Units per package WA_SG11702 WA_SG11802 WA_SG11902 40/0,50 63/0,5 3-pole 40/0,50 63/0,5 40/0,50 63/0,5 PBSM-402/003 262323 1 / 20 PBSM-402/01 262324 1 / 20 PBSM-402/03 262325 1 / 20 PBSM-402/05 262326 1 / 20 PBSM-402/1 262327 1 / 20 PBSM-632/003 262426 1 / 20 PBSM-632/01 262427 1 / 20 PBSM-632/03 262428 1 / 20 PBSM-632/05 262429 1 / 20 PBSM-632/1 262431 1 / 20 PBSM-403/003 262537 1 / 20 PBSM-403/01 262538 1 / 20 PBSM-403/03 262539 1 / 20 PBSM-403/05 262541 1 / 20 PBSM-403/1 262542 1 / 20 PBSM-633/003 262556 1 / 20 PBSM-633/01 262557 1 / 20 PBSM-633/03 262558 1 / 20 PBSM-633/05 262559 1 / 20 PBSM-633/1 262560 1 / 20 PBSM-404/003 262568 2 / 20 PBSM-404/01 262569 2 / 20 PBSM-404/03 262570 2 / 20 PBSM-404/05 262571 2 / 20 PBSM-404/1 262572 2 / 20 PBSM-634/003 262590 2 / 20 PBSM-634/01 262591 2 / 20 PBSM-634/03 262592 2 / 20 PBSM-634/05 262595 2 / 20 PBSM-634/1 262596 2 / 20 Add-on Residual Current Protection Unit PBSM MW conditionaly surge-current-proof, 250 A, sensitive to residual pulsating DC, type WA_SG11702 WA_SG11802 WA_SG11902 3-pole PBSM-402/003-A 262328 1 / 20 PBSM-402/01-A 262329 1 / 20 PBSM-402/03-A 262420 1 / 20 PBSM-402/1-A 262421 1 / 20 PBSM-632/003-A 262530 1 / 20 PBSM-632/01-A 262531 1 / 20 PBSM-632/03-A 262532 1 / 20 PBSM-632/1-A 262533 1 / 20 PBSM-403/003-A 262543 1 / 20 PBSM-403/01-A 262544 1 / 20 PBSM-403/03-A 262545 1 / 20 PBSM-403/1-A 262546 1 / 20 PBSM-633/003-A 262561 1 / 20 PBSM-633/01-A 262562 1 / 20 PBSM-633/03-A 262563 1 / 20 PBSM-633/1-A 262564 1 / 20 PBSM-404/003-A 262573 2 / 20 PBSM-404/01-A 262574 2 / 20 PBSM-404/03-A 262575 2 / 20 PBSM-404/1-A 262576 2 / 20 PBSM-634/003-A 262597 2 / 20 PBSM-634/01-A 262598 2 / 20 PBSM-634/03-A 262600 2 / 20 PBSM-634/1-A 262602 2 / 20 Explanation PBSM: P = XPole, BS = Add-on Residual Current Protection Unit onto PLS 37

SG_Bestell_MV_E.qxd 25.04.2005 09:39 Seite 38 Add-on Residual Current Protection Unit PBSM surge current-proof 3 ka, type G (ÖVE E 8601) MW Max. nominal current of PLS./I n (A) ype designation Article-No. Units per package WA_SG11702 PBSM-402/003-G 262422 1 / 20 WA_SG11802 3-pole PBSM-403/003-G 262552 1 / 20 WA_SG11902 PBSM-404/003-G 262577 2 / 20 Add-on Residual Current Protection Unit PBSM selective and surge current-proof 5 ka, type S MW Max. nominal current of PLS./I n (A) ype designation Article-No. Units per package WA_SG11702 PBSM-402/01-S 262423 1 / 20 PBSM-402/03-S 262424 1 / 20 PBSM-402/1-S 262425 1 / 20 PBSM-632/01-S 262534 1 / 20 PBSM-632/03-S 262535 1 / 20 PBSM-632/1-S 262536 1 / 20 WA_SG11802 3-pole PBSM-403/01-S 262553 1 / 20 PBSM-403/03-S 262554 1 / 20 PBSM-403/1-S 262555 1 / 20 PBSM-633/01-S 262565 1 / 20 PBSM-633/03-S 262566 1 / 20 PBSM-633/1-S 262567 1 / 20 WA_SG11902 PBSM-404/01-S 262586 2 / 20 PBSM-404/03-S 262587 2 / 20 PBSM-404/1-S 262588 2 / 20 PBSM-634/01-S 262603 2 / 20 PBSM-634/03-S 262605 2 / 20 PBSM-634/1-S 262607 2 / 20 Explanation PBSM: P = XPole, BS = Add-on Residual Current Protection Unit onto PLS. 38

SG_Bestell_MV_E.qxd 25.04.2005 09:39 Seite 39 Add-on Residual Current Protection Unit PBH By combination with miniature circuit breaker PLH => RCBO unit (MCCB) Add-on residual current unit (screw connection) for 80 or 125 A (2- pole and ) High flexibility and ease of installation thanks to variable wiring Free selection of main power supply Auxiliary switch 1 make contact included as standard in all PBH versions Permits combinations with a variety of characteristics thanks to the different rated currents and characteristics of the miniature circuit breakers PLH which can be connected For commercial and industry applications For subsequent mounting onto 2, 3, 3+N and -miniature circuit breakers PLH he screw connection to the PLH-device can be unscrewed at any time. Consequently, in case of modifications of the systems to be protected, the installation can be adapted to new requirements at any time. SG6002 39

SG_Bestell_MV_E.qxd 25.04.2005 09:39 Seite 40 Add-on Residual Current Protection Unit PBH AC-sensitive, conditionally surge-current-proof 250 A I n /I n (A) ype Designation Article No. Units per package SG5902 80/0.03 80/0.30 80/0.50 80/1.00 125/0.03 125/0.30 125/0.50 125/1.00 PBH-80/2/003 248818 1 / 4 PBH-80/2/03 248820 1 / 4 PBH-80/2/05 248822 1 / 4 PBH-80/2/1 248824 1 / 4 PBH-125/2/003 248799 1 / 4 PBH-125/2/03 248801 1 / 4 PBH-125/2/05 248803 1 / 4 PBH-125/2/1 248805 1 / 4 SG6002 80/0.03 80/0.30 80/0.50 80/1.00 125/0.03 125/0.30 125/0.50 125/1.00 PBH-80/4/003 248826 1 / 4 PBH-80/4/03 248828 1 / 4 PBH-80/4/05 248831 1 / 4 PBH-80/4/1 248834 1 / 4 PBH-125/4/003 248807 1 / 4 PBH-125/4/03 248809 1 / 4 PBH-125/4/05 248812 1 / 4 PBH-125/4/1 248815 1 / 4 Add-on Residual Current Protection Unit PBH Sensitive to residual pulsating DC, conditionally surge current-proof 250 A I n /I n (A) ype Designation Article No. Units per package SG5902 80/0.03 80/0.30 80/0.50 80/1.00 125/0.03 125/0.30 125/0.50 125/1.00 PBH-80/2/003-A 248819 1 / 4 PBH-80/2/03-A 248821 1 / 4 PBH-80/2/05-A 248823 1 / 4 PBH-80/2/1-A 248825 1 / 4 PBH-125/2/003-A 248800 1 / 4 PBH-125/2/03-A 248802 1 / 4 PBH-125/2/05-A 248804 1 / 4 PBH-125/2/1-A 248806 1 / 4 SG6002 80/0.03 80/0.30 80/0.50 80/1.00 125/0.03 125/0.30 125/0.50 125/1.00 PBH-80/4/003-A 248827 1 / 4 PBH-80/4/03-A 248829 1 / 4 PBH-80/4/05-A 248832 1 / 4 PBH-80/4/1-A 248835 1 / 4 PBH-125/4/003-A 248808 1 / 4 PBH-125/4/03-A 248810 1 / 4 PBH-125/4/05-A 248813 1 / 4 PBH-125/4/1-A 248816 1 / 4 Explanation PBH: P = XPole, BH = Add-on Residual Current Protection Unit onto PLH 40

SG_Bestell_MV_E.qxd 25.04.2005 09:40 Seite 41 Add-on Residual Current Protection Unit PBH Selective + surge current-proof 5 ka, type S/A I n /I n (A) ype Designation Article No. Units per package wa_sg1101 / WA_SG0301 80/0.30 80/0.50 80/1.00 125/0.30 125/0.50 125/1.00 PBH-80/4/03-S/A 248830 1 / 4 PBH-80/4/05-S/A 248833 1 / 4 PBH-80/4/1-S/A 248836 1 / 4 PBH-125/4/03-S/A 248811 1 / 4 PBH-125/4/05-S/A 248814 1 / 4 PBH-125/4/1-S/A 248817 1 / 4 Accessories for residual current protection unit PBH Operational voltage range V~ ype Designation Article No. Units per package Shunt trip release SG9998 110-415 12-60 Z-BHASA/230 248445 8 Z-BHASA/24 248444 8 Explanation PBH: P = XPole, BH = Add-on Residual Current Protection Unit onto PLH 41

SG_echnik_MV_E.qxd 25.04.2005 10:48 Seite 589 Add-on Residual Current Protection Unit PBSM Add-on residual current unit Line voltage-independent tripping By combining this device with a top-quality miniature circuit breaker type PLS. (exept PLSN.) a top-quality RCBO unit (combined RCD/MCB device) is formed. Rated current 40 and 63 A Permits combinations with a variety of characteristics thanks to the different rated currents and characteristics of the PLS.-miniature cirvuit breakers which can be connected Comrehensive range of accessories suitable for subsequent installation onto PLS. ype -A: Protect against special forms of residual pulsating DC which have not been smoothed. ype -G: High reliability against unwanted tripping. Compulsory for any circuit where personal injury or damage to property may occur in case of unwanted tripping (ÖVE-EN1, Part1, 12.14). ype -S: Selective residual current device, either sensitive to AC, type -S, or sensitive to pulsating DC, type -S/A, for protection against special forms of residual pulsating DC which have not been smoothed. Compulsory for systems with surge arresters downstream of the RCD (ÖVE-EN1, Part 1, 12.15). Accessories : Cover cap for draw-out connection bar Slotted one-way cheese head screw echnical Data included included Accessories (on PLS.): Auxiliary switch for subsequent installation ZP-AHK 248436 ripping signal contact for subsequent installation ZP-NHK 248437 Remote control and automatic switching device Z-FW/LP 248296 Shunt trip release ZP-ASA/.. 248438, 248439 Undervoltage release Z-USA/.. 248288-248291 Compact enclosure KLV-C-2 276240 KLV-C-4 276241 Additional terminal 35mm 2 HA7-ZK35 751942199 Anti-tamper device HA7-SPE 750960510 Connection diagramms 3-pole 2 4 2' 4' 2 4 6 2' 4' 6' 2 4 6 8N 2' 4' 6' 8N' Electrical Design according to IEC/EN 61009 Current test marks as printed onto the device ripping instantaneous 250A (8/20µ), surge current-proof ype G 10 ms delay 3kA (8/20µ), surge current-proof ype S 40 ms delay 6kA - with selective disconnecting function Rated voltage U n 230/400 V AC Operational voltage range 196-440 V Rated frequency 50 Hz Rated current I n 40 A, 63 A Rated tripping current I n 30, 100, 300, 500, 1000 ma Rated non-tripping current I no 0.5 I n Sensitivity AC and pulsating DC Service short circuit breaking capacity I cs same as connected PLS. (7.5 ka) Rated breaking capacity I cn same as connected PLS. (10 ka) Rated fault breaking capacity I m 6 ka (U n = 230V) 3 ka (U n = 400V) Mechanical Frame-size Device height Device width Mounting Degree of protection installed device Fastening screw Screw head breaking torque Upper and lower terminals erminal screws erminal protection 45 mm 90 mm 70 mm (2p), 107.5 mm (3p), 125 mm (4p) fix mounted onto PLS. IP40 M 2.5 (slotted one-way cheese head screw; > 0.6 Nm lift terminals M 5 (combined Philips/standard head screws according to DIN7962-Z2, Pozidrive) finger and hand touch safe, BGV A3, ÖVE-EN 6 erminal capacity Rigid conductors 1 x (1-25) mm 2 Flexible conductors (with wire end sleeve) 1 x (0.75-16) mm 2 Busbar thickness 0.8-2 mm Permitted ambient temperature range -25 C to +40 C Resistance to climatic conditions acc. to IEC/EN 60068-2 (25..55 C/90..95% relative humidity) Dimensions (mm) 2p 5,5 90 45 12mm 70 44 60 9,5 3p 4p 12mm 12mm 107,5 125 589

SG_echnik_MV_E.qxd 25.04.2005 10:48 Seite 590 Add-on Residual Current Protection Unit PBH By combination with miniature circuit breaker PLH => RCBO-Unit (MCCB) Add-on residual current unit (screw connection) for 80 or 125 A ( and ) High flexibility and ease of installation thanks to variable wiring (400 mm flexible connection wires 2p = 2 units, 4p = 4 units included in the set) Free selection of main power supply Auxiliary switch 1 NO included as standard in all PBH versions Permits combinations with a variety of characteristics thanks to the different rated currents and characteristics of the miniature circuit breakers PLH which can be connected For trade and industry applications For subsequent mounting onto 2, 3, 3+N and -miniature circuit breakers PLH oggle (serves as switch position- and tripping indicator) he screw connection to the PLH-device can be unscrewed at any time. Consequently, in case of modifications of the systems to be protected, the installation can be adapted to new requirements at any time. Accessories: Flexible connection wires (connection to PLH) are included in the standard set: 80A 2 x 16mm 2 (400mm each) 80A 4 x 16mm 2 (400mm each) 125A 2 x 35mm 2 (400mm each) 125A 4 x 35mm 2 (400mm each) Connection diagrams echnical Data Electrical Design according to IEC/EN 60947-2 Current test marks as printed onto the device Current flow paths Rated voltage U e 230/400 V AC Operational voltage range 196-440 V Rated frequency 50 Hz Rated current I n 80 A, 125 A Rated tripping current I n 30, 300, 500, 1000 ma Rated non-tripping current I no 0.5 I n Sensitivity AC and pulsating DC ripping characteristic instantaneous 250A (8/20µ), surge current-proof; ype S 40 ms delay 6kA (8/20µ) with selective disconnecting function, surge current-proof Rated service short circuit breaking capacity I cn same as connected PLH Rated ultimate circuit breaking capacity I cu same as connected PLH Rated fault short circuit breaking capacity I /n = I cu Rated peak withstand voltage U imp 4 kv (1.2/50µ) Endurance mechanical comp. PBH-80 >10000 PBH-125 >8000 Endurance electrical comp. PBH-80 >1500 PBH-125 >1000 Dimensions (mm) PBH/2p + PLH/2p Auxiliary Contact Utilisation category AC15 Rated voltage U e Rated operational current I e Mechanical Frame size Device height Device width Depth of central body Mounting Upper and lower terminals erminal protection 250 V AC 16 A AC 45 mm 90 mm 95 mm (5,5MU) 60 mm screwed onto PLH 2-, 3-, ; PBH-ASA lift terminals finger and hand touch safe, BGV A3, ÖVE-EN 6 erminal capacity Main conductor 2.5-50 mm 2 Auxiliary switch 1-25 mm 2 Degree of protection, built-in IP40 Permissible ambient temperature range -25 C to +40 C Resistance to climatic conditions acc. to IEC 60068-2 (25...55 C/90...95% relative humidity) PBH/4p + PLH/3p+N PBH/4p + PLH/3p PBH/4p + PLH/4p 590

SG_echnik_MV_E.qxd 25.04.2005 10:48 Seite 591 Wiring options Mounting PBH + PLH SG15102 SG15402 PBH + PLH Connection PBH/4p + PLH/3p PBH/4p PLH/3p SG15202 SG15302 Mounting arrangement residual current protection unit - shunt trip release - miniature circuit breaker - auxiliary contact PBH- PBH- Z-PBH-ASA PLH-3+N-pole 1 + + + 2 Z-LHK 13 21 22 14 591

SG_echnik_MV_E.qxd 25.04.2005 10:48 Seite 592 Accessories for PBH Shunt rip Release Z-PBH-ASA Can be mounted subsequently Contact position indicator red - green Marking labels can be fitted Wide operational voltage range Sufficient power of extra low voltage source must be ensured PBH-ASA/24: min. 90 VA Screws for mounting included PBH => PBH-ASA => PLH Connection diagram 1 2 echnical Data Z-PBH-ASA/24 Z-PBH-ASA/230 Electrical Minimum pulse duration 15 ms 10 ms Internal resistance 2 Ω 130 Ω Duty 100% 100% ripping time < 20 ms < 20 ms Peak withstand voltage (1.2/50µ) 2 kv 2 kv Endurance >4,000 operating cycles >4,000 operating cycles AC voltage range: Responding limit 8 V 70 V Operational voltage range 12-60 V 110-415 V Maximum current consumption during switch-on 1.4-7 A 3.4 A (at 230V) Current flow time at max. current consumption 4.0 ms 4.5 ms DC voltage range: Responding limit 11 V 90 V Operational voltage range 12-60 V 110-230 V Maximum current consumption during switch-on 1.7 A typ. 1.7 A typ. Current flow time at max. current consumption 2 ms 4 ms Mechanical Frame size 45 mm 45 mm Device height 90 mm 90 mm Device width 27 mm 27 mm Mounting quick fastening on DIN rail EN 50022 Degree of protection, built-in IP40 IP40 Upper and lower terminal screws lift terminals lift terminals erminal capacity 2.5-30 mm 2 2.5-30 mm 2 Fastening torque of terminal screws 4 Nm 4 Nm Dimensions (mm) 592