Kaye Validator AVS Version Z3007, Rev D June Advanced Validation System Console SW Enhancements

Similar documents
IP-guard v3.2 Migration Guideline

iphone Backup 1 P a g e

Standard Operating Procedure for the Kaye Validator AVS System

OMS User Manual. Document Author & Review Name Position Signature Date SHAH Marie Software Project Manager 25/04/2016

Software Release Notes

Nova series update F/W & Boot code from Boot Utility

Mobile Inventory Tracking & Sales Management Software. Installation Procedure

PS751 - Firmware(FW) Upgrade Instruction

Web management. How to access to the web management. Log into the web management via a laptop

BRIVO ONSITE QUICK START GUIDE 09/14/17

Software Release Notes

PROFOREST FIELD AUDIT MOBILE APPLICATION USER MANUAL

Deploying ios Devices with the Casper Suite and Apple Configurator. Technical Paper June 2012

GIGATRAK CLIENT INSTALL HANDHELD TERMINAL

Smart Home Controller 2.3 Release Notes Contents

Audio Signage Solution

COMPANY ADMIN GUIDE. CurateFx is provided under license to TM Forum by Tr3Dent, and powered by the Tr3Dent Transformation Accelerator Platform. V0.

RF Thermal Validation System. Kaye RF ValProbe PRESSURE HUMIDITY. High accuracy measurement of temperature and humidity

14. Firmware update procedure

Introduction. Package Checklist. Minimum System Requirements. Registering Your Product. More Help

Face & Fingerprint Recognition Product

Software.

GIGATRAK HANDHELD INSTALL AND SYNC

Have a Backup. Learning objectives. An understanding of the importance of backing up and archiving. Ability to prepare a backup plan

STAROS user manual. Headquarter Flat D, 5/F, Excelsior Building, 364 Nathan Rd., Kowloon, H.K TEL: (852) FAX: (852)

ICP DAS IOP760AM FAQ. FAQ Version ICP DAS Co., Ltd

1. Introduction Minimum system requirements Basic Concept Server mode

Auto Upgrade. Auto upgrade - Network Method

Registering & Upgrading FW VIA Connect PRO

S38 Basic Configuration

IceWarp to IceWarp Migration Guide

Membrane Bezel Kit. Models: T600, T600e, T500, T500e, Speed Scrub 500 and A500

MCSA Windows 10. A Success Guide to Prepare- Microsoft Configuring Windows Devices. edusum.com

Do not connect the printer to your computer s USB port until advised to.

PrepAwayExam. High-efficient Exam Materials are the best high pass-rate Exam Dumps

Contents. Table of Contents

PDU Utility. User Manual

GIGATRAK HANDHELD TERMINAL DOWNLOAD

IDVisor Smart ID Scanner. User s Guide. Age Verification machine

Royal. Wi-Fi Memory Expander

Trial Guide. June 2018 Samsung Electronics. A new way to control OS version for B2B customers

You can measure distances and the area within a boundary and then convert those measurements to GeoMarks.

Setup Guide for Hard-Wire Ethernet Connected TP-Link TL-WR841N 300 Mbps Wireless N Router AARP Foundation Tax-Aide Colorado Technology Specialist

Honeywell MasterLink Software Application R500.1

QUICK START GUIDE. QC IP Camera & NVR Bundle ENGLISH

CLIQ Web Manager. User Manual. The global leader in door opening solutions V 6.1

How to recover from a forgotten administrator password

Evidence.com June 2016 Release Notes

WISP Setup Guide for TP-Link TL-WR841N 300 Mbps Wireless N Router AARP Foundation Tax-Aide Colorado Technology Specialist

SC-T35/SC-T45/SC-T46/SC-T47 ViewSonic Device Manager User Guide

Operating Instructions

DATA ARCHIVING SOFTWARE V.

If your Mac keeps asking for the login keychain password

TEAM5 Operation Manual

On occasion, due to a failure or water damage it may become necessary to replace an APEX, APEX LITE, or APEX JR with another controller.

User s Guide Brother Software Licence Management Tool

TRIDENT - CMS Plus. 64CH Central Management System Software

Oct 2007 Version 1.01

This means that pre revisions of AMWorks software may not be able to either open or read the newer database files.

Note, you must have Java installed on your computer in order to use Exactly. Download Java here: Installing Exactly

AtmoCONTROL FDA EDITION IQ DOCUMENTATION OQ DOCUMENTATION 100% ATMOSAFE. MADE IN GERMANY.

GIGATRAK CLIENT INSTALL HANDHELD TERMINAL

RX300 Settings Manual General

Guide for Initial StrataSync Setup for new users and admins

How to assign an IP address and access your device

Service Bulletin Rev Firmware Upgrade for ACRC100 Series

VMware AirWatch Database Migration Guide A sample procedure for migrating your AirWatch database

Evidence.com May 2016 Release Notes

OSMO Release Notes Major Updates. Notes

MetaMoJi Share for Business Ver. 3 MetaMoJi Note for Business Ver. 3 Migration Guide

Xerox IJ Print Server Powered By Fiery. Information Assurance Disclosure

Technical Bulletin. Serial Number Effective: Q Product Line: Merlin Elite Pro Subject: Merlin Elite Pro Improvements

FLOWgate500. Software Manual. Software Manual FLOWgate500 Release 2.2. Revision number: V2.2. Manufacturer: SICK AG. Erwin-Sick-Str.

Wireless DCP. Owner s Manual. Introduction

IPM Secure Hardening Guidelines

Firmware Update Process

PIVOT CMS CLIENT SOFTWARE USER MANUAL

SPDS v2.0 The Smart Way to Analyze and Fix the Printer

FOTA Update Procedure for NL-SW-LTE-S7588-V

ASSA ABLOY. CLIQ Connect PC Application FAQ

Migration of Cisco Physical Access Manager to the Identiv Connected Physical Access Manager

NORDSON CORPORATION AMHERST, OHIO USA

Configuring, Managing and Troubleshooting Microsoft Exchange Server 2010 Service Pack 2

Initial App SetupR. Initial App Setup Mertik Maxitrol GmbH & Co. KG

C-Assist Set up Guide

Installation. SIM card. microsd card (optional)

new world ERP Server Migration Checklist New World ERP TMS

Table of Contents 1. Quick Start, Short Form Instruction 2. Display overview 3. Settings 4. Info 5. Chart 6. CLI 7. Support 8. MAC friendly version

VIEVU 2 Configuration Utility User Guide

PAS. Installation Guide. BG0608 Rev. A1. Copyright SATEC Ltd.

Moving HRtrack to a new computer

X35 Apollo System Upgrading Monitor Software & ECU Firmware Version

X35 Apollo System Upgrading Monitor Software & ECU Firmware Version

Neposmart NS14WG Indoor and NS14BG Outdoor Camera Web App User Manual

User Manual. Thermo Scientific Orion

Shepherd II. Collective Management & Configuration Utility for VIVOTEK Cameras. Rev Camera 02. Camera 01. Camera 04.

DCH-G022 mydlink Connected Home Hub

User Guide for Windows OS

PMS 138 C Moto Black spine width spine width 100% 100%

EAN-FPGA Firmware Update 1500-OEM

Transcription:

Kaye Validator AVS Version 1.2.3 Z3007, Rev D June 2017 Kaye Advanced Validation System (AVS) version 1.2.3 is an upgrade for the Advanced Validation System version 1.2.1, including the enhancements and fixes described below. Kaye Validator AVS 1.2.3 is released with software version 1.2.3.0 software compatible with firmware version 1.2.1.61 only. Upgrade AVS Software 1.2.3 first, then using the software, upgrade AVS firmware to version 1.2.1.61. No Upgrade of firmware is required if your Advanced Validation System firmware is already at version 1.2.1.61. AVS Software 1.2.3 needs to be revalidated with IQ/OQ procedure. Advanced Validation System Console SW 1.2.3 Enhancements The version 1.2.3 software is designed to upgrade the previous versions of AVS software on consoles running under Windows 8.1. Before installing the version 1.2.3 software you should close any programs that may be running. Installing the Version 1.2.3 Software from USB Complete the following steps to install the version 1.2.3 software: 1. Sign out the Kaye Operator user and Login as Kaye Administrator 2. Insert the USB containing Kaye Validator Upgrade installer into the Console. 3. Refer the Console SW Upgrade installer guide to complete the installation.

Kaye Advanced Validation System (AVS) version 1.2.1 Enhancements and defect fixes Kaye Advanced Validation System (AVS) version 1.2.1 is an upgrade for the Advanced Validation System version 1.2.0.21, including the enhancements and fixes described below. Kaye Validator AVS 1.2.1 is released with software version 1.2.1.0 software compatible with firmware version 1.2.1.61 only. Upgrade AVS Software 1.2.1 first, then using the software, upgrade AVS firmware to version 1.2.1.61. No Upgrade of firmware is required if your Advanced Validation System firmware is already at version 1.2.1.61. AVS Software 1.2.1 needs to be revalidated with IQ/OQ procedure. Advanced Validation System Console SW 1.2.1 Enhancements Improved support for Sync In, Sync Out and Archive operations to folder on network path (mapped drive) with Windows domain security. The version 1.2.1 software is designed to upgrade the previous versions of AVS software on consoles running under Windows 8.1. Before installing the version 1.2.1 software you should close any programs that may be running. Installing the Version 1.2.1 Software from USB Complete the following steps to install the version 1.2.1 software: 4. Sign out the Kaye Operator user and Login as Kaye Administrator 5. Insert the USB containing Kaye Validator Upgrade installer into the Console. 6. Refer the Console SW Upgrade installer guide to complete the installation.

Kaye Advanced Validation System (AVS) version 1.2 Enhancements and defect fixes Kaye Advanced Validation System (AVS) version 1.2 is an upgrade for the Advanced Validation System version 1.1, including the enhancements and fixes described below. Kaye Validator AVS 1.2 is released with software version 1.2.0.21 software and firmware version 1.2.1.61. AVS Software 1.2 is compatible with firmware version 1.2.1.61 only. Upgrade AVS Software 1.2 first, then using the software, upgrade AVS firmware to version 1.2.1.61. No Upgrade of firmware is needed if your Advanced Validation System firmware is already at version 1.2.1.61. AVS Software 1.2 needs to be revalidated with IQ/OQ procedure. Advanced Validation System Console SW 1.2 Enhancements Optimization of AVS Wi-Fi configuration and functionality. Setup review to display complete information of Setup in Qualification screen. User can add Limit Lines for Real Time Qualification graph. User can have graph zoom ability to define fixed Y and X axis range. Support for manual scaling of graph. User can to synchronize time at start of qualification. User can add Cycle time and Exposure time to real-time screen (statistical box). User can set privilege for Stop Qualification. Display of Event messages during Qualification and effect in Audit Trail. User can start Qualification with at least some valid data for Manual operation. Improved cycle selection screen in Reports. Display of AVS LED connection and study status. User can have Customer logo in all reports. Allow user to define report footer parameters in Preferences and apply to Setup/Calibration/Verification reports. Update firmware versions format in Reports and Main App. Determine if AVS firmware and AVS console software are compatible or not. Improved software upgrade installation. AVS OS image and firmware auto installation from Console SW.

Advanced Validation System FW 1.2.1.61 Enhancements Auto reconnect Wi-Fi (on network availability & AVS restart). Allow user to have up-to 63 characters for Wi-Fi password. Improved report file generation. Support of qualification cycle time feature. Improved LED indication function. Firmware Upgrade Installation AVS console SW 1.2 provides functionality to upgrade AVS FW to user with Admin privileges. The AVS Firmware Upgrade tool is accessible from the Admin tile. For upgrading the Firmware please follow the steps exactly as outlined in the software: 1. Dock the console to the Kaye Validator AVS that is supposed to get upgraded Note: FW upgrade using Ethernet or Wi-Fi is not supported! Press the Get AVS SN number to establish a connection to the Kaye Validator AVS. This assures the connectivity and retrieves the serial number for the audit trail entry. 2. Insert a USB thumb drive with the firmware as provided by Kaye into the console USB port located on back of the Kaye Validator AVS unit. You can easily identify the correct USB port by referring to the displayed picture. 3. Now everything is ready to upgrade the firmware. Please make sure the Validator AVS is properly powered and not switched off during the upgrade process. Otherwise the system can be damaged and need to get restored in a Kaye Service Center. Press Upgrade Firmware and wait until a message tell you to restart the Kaye Validator AVS. The version 1.2 software is designed to upgrade the previous versions of AVS software on consoles running under Windows 8.1. Before installing the version 1.2 software you should close any programs that may be running. Installing the Version 1.2 Software from USB Complete the following steps to install the version 1.2 software: 7. Insert the USB containing Kaye Validator Upgrade installer into the Console. 8. Refer the Console SW Upgrade installer guide to complete the installation.

Kaye Advanced Validation System (AVS) version 1.1 Enhancements and defect fixes Kaye Advanced Validation System (AVS) version 1.1 is an upgrade for the Advanced Validation System version 1.0, including the enhancements and fixes described below. Kaye Validator AVS 1.1 is released with software version 1.1.0.9 software and firmware version 0.0.1.45. AVS Software 1.1.0.9 is compatible with FW version 0.0.1.45 only. Upgrade AVS Software 1.1.0.9 first, then using the software, upgrade AVS firmware to version 0.0.1.45. No Upgrade of firmware is needed if your Advanced Validation System firmware is already at version 0.0.1.45. AVS Software 1.1.0.9 needs to be revalidated with IQ/OQ procedure. Advanced Validation System Console SW 1.1.0.9 Enhancements The Kaye AVS SW is changed to separate calibration and verification parameters in setup. The Kaye AVS SW is changed so that user define number of set points for calibration and verification in setup. The Kaye AVS SW is changed to so that user can modify verification parameters before starting verification process. The Kaye AVS SW is changed to so that user can run a manual calibration. Manual Calibration and Verification can be run in scenarios like without both IRTD and Bath connected, with IRTD and without Bath connected and without IRTD and with bath connected. The Kaye AVS SW is changed to provide archive functionality for exporting and removing old data files to and from the console. The Kaye AVS SW is changed so that CSV export may show details of Setup. The Kaye AVS SW is changed to allow AVS firmware upgrade via the Console. The Kaye AVS SW is changed to provide sync feature to allow data file synchronization across several consoles. The functionality is also used to backup, restore and archive files. Issues related to incorrect set point information in calibration screen is solved. Issues related to incorrect checklist in calibration screen is solved. Advanced Validation System FW 0.0.1.45 Enhancements The Kaye AVS FW is changed to separate calibration and verification parameters in setup. The Kaye AVS FW is changed to so that user can choose verification parameters (Low Set Point, High Set Point and Check Point) different than calibration parameters. The Kaye AVS FW is changed to so that user can run a manual calibration. The Kaye AVS FW is changed to so that user can choose lethality calculation option While Max Temp >= and While Min Temp >=.