Classic Keys Expansion board for the PC1

Similar documents
Kurzweil PCR-1/PCR-2

German D Grand EXP. Expansion Board for the PC3K Installation Instructions

Installing Kurzweil K2661 ROM Options

HARMONi G3. Quick Start Guide for HARMONi G3. imac Processor/FireWire Upgrade

Upgrading and Servicing Guide

E-MU PN FI10993 Rev. B

Hardware Replacement Guide Types 8099, 8116, 8155, 8156 Types 8157, 8158, 8159, 8160 Types 8215, 9210, 9211

Dell OptiPlex All-in-One. Stand Installation Guide

CRESCENDO /PB G3. Processor Upgrade Card for Macintosh PowerBook 1400 Series Computers. Quick Start Guide for Crescendo/PB G3

Upgrading and Servicing Guide

3 1 ROM. Installation Manual

Upgrading and Servicing Guide

CRESCENDO /7200 G3. Quick Start Guide for Crescendo /7200. Processor Upgrade Card for Power Macintosh 7200/8200 Computers

Upgrading and Servicing Guide

Upgrading and Servicing Guide

Memory (RAM) Replacement Instructions. apple PowerBook (FireWire) Tools Required. Electrostatic Discharge (ESD)

ENCORE /ST G4. Processor Upgrade Card for Power Mac G4 AGP Graphics. Quick Start Guide for Encore/ST G4

PC9/P9 Floppy Drive Replacement

H4 Series Hardware Replacement Guide

Hardware Replacement Guide Lenovo 3000 J Series. Types 8453, 8454, 8455, 8458, 8459, 8460

Getting Started. Overview of the Splash G3535

Hardware Replacement Guide

MacBook Core 2 Duo Clutch Cover

XPS 15 2-in-1. Service Manual. Computer Model: XPS Regulatory Model: P73F Regulatory Type: P73F001

RISC OS 3 software upgrade fitting instructions

Installation Note. Enhanced Memory Upgrade Kit (Option B72) for Agilent ESA-E Series and ESA-L Series Spectrum Analyzers

Upgrading and Servicing Guide

Table of Contents. 1.Introduction... P.2. 2.Product Tour... P Operating Instructions... P Important Notes... P.10

User Guide for NUC7i3DNHNC. Intel NUC7 Business, a Mini PC with Windows 10 NUC7i3DNHNC. User Guide

PC9/P9 CPU Card Replacement

Quick Start Guide ONLY for Encore/ST G4 Duet 1.8 GHz

TEMPO ATA133. Macintosh PCI Host Adapter Card. Quick Start Guide for Tempo ATA133

Sonnet AV/HPV Card Video Adapter Kit

Quick Start Guide ONLY for Encore/ST G4 Duet 1.8 GHz

Addendum for Tempo HD (Without Drive)

16MB Sound Flash Installation Instructions for E6400 Ultra, E4XT Ultra & E-Synth Ultra

Installation Guide. Wyse R Class Conversion to WES7. Wyse USB Firmware Tool TM Release Issue: PN: L Rev. B

User Guide. Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i5BNKP. Intel NUC 7 Enthusiast, a Mini PC with Windows 10 NUC7i7BNKQ

Intel NUC Kit NUC6CAYS User Guide

Dell XPS 14z Owner s Manual

Installing System Board Options

ENCORE /ST G4 DUET. Dual Processor Upgrade Card for Power Mac G4 AGP Graphics. Quick Start Guide for Encore/ST G4 Duet

2005 Sony Corporation Printed in China (1) Quick Start Guide NW-A1000 series / A3000 series

imac Intel 21.5" EMC 2638 RAM Replacement

User Guide. Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7BEKQA. Intel NUC 8 Home, a Mini PC with Windows 10 NUC8i5BEKPA

Software Upgrade v 2.0

MacBook Core 2 Duo Display Replacement

imac Intel 21.5" Retina 4K Display (2017) RAM

ThinkCentre Hardware Installation and Replacement Guide. Machine Types 6062, 6065, 6071, 6076, 6089, 7103, 9011, 9014, 9071, 9089, 9162, 9182, 9303

Boot Camp Installation & Setup Guide

Microprocessor Module Replacement Kit for Multi-Zone Leak Monitors Instruction Manual

Using memory cards (not supplied)

5x86 Third Serial Port Installation

RISC OS ROM upgrade kit installation and configuration instructions (For use with Archimedes 300 and 400 Series computers)

NASCAR Team Racing (Version 2.0) Motion Cabinet Upgrade Instructions

Mac OS 8 Installation Instructions for Sonnet Presto and Presto Plus Processor Upgrade Cards

Wall-Mounting your HP TouchSmart. User Guide

Replacing the Gateway M405 Keyboard

Installing MacBook Pro 17" Unibody Dual Hard Drive

Music Technologies Group. MTG Pro One TurboCPU CV (DAC) Installation Guide

Ribbon Supply Spindle Maintenance Kit

Hard Disk Drive (HDD) Data Protection Kit Installation Instructions

Acorn PC Card User Guide

Computer Upgrades CAUTION

An ISO 9001 Company. BOP 1KW-MG FIRMWARE RETROFIT KIT

READ ME FIRST Windows 95/98/Me/2000

TEMPO SATA X4i. Quick Start Guide for Tempo SATA X4i. Serial ATA Host Adapter for PCI-X. You Should Have. System Requirements

K Service Source. Macintosh II/IIx/IIfx

Service Manual - Memory Upgrade

Installation Guide. Copyright 2005 MSI Computer Corp.

Replacing or Upgrading DiskOnChip Memory

U-Storage User s Manual. Version 2.3

User Guide for NUC7CJYSAL. Intel NUC 7 Essential, a Mini PC with Windows 10 NUC7CJYSAL. User Guide

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Power Xpert Meter 2000 Gateway Card Kit

Retina MacBook 2017 Upper Case Assembly

Written By: Andrew Optimus Goldberg

Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i3BNHXF. Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i5BNHXF

4.1 General. 4 Replacement Procedures

WEASEL N/B MAINTENANCE

CncGcoder Models HD & HDx Manual

Power Xpert Meter 2000 Gateway Card Kit

SwitchBlade Switch Controller Quick Install Guide

Replacement Instructions

XPS 13 Convertible Service Manual

Editor/Plug-In Editor Manual

Copyright 2007 Hewlett-Packard Development Company, L.P. Windows is a U.S. registered trademark of Microsoft Corporation.

READ ME FIRST. *DSL Equipment Installation Guide: Efficient Networks 5260

TV1 Digital Player User s Manual

CameraMate. Hi-Speed 10 in 1 Digital Media Reader/Writer User s Guide

MacBook Core 2 Duo AirPort Card Replacement

TOYOTA YARIS HATCHBACK Preparation

READ ME FIRST Windows 95/98/Me/2000

User Guide for NUC7CJYSAL. Intel NUC 7 Essential, a Mini PC with Windows 10 NUC7CJYSAL. User Guide

Specifications. It s the sound.

JLTX Lever and Joystick Replacement Instructions

Cube Installation Kit Manual ENCORE /ST G4

Maxxyz Compact Retrofit Kit Installation Guide

ipod Classic Headphone Jack & Hold Switch Replacement

Part Number: 92P1476. h Battery pack. h Computer

Transcription:

Kurzweil PCR-2 Classic Keys Expansion board for the PC1 Installation Instructions November 7, 2005 TM 2005 All rights reserved. Kurzweil is a product line of Kurzweil Co., Ltd; Kurzweil, PC1 and KDFX are trademarks of Kurzweil Co., Ltd. All other products and brand names are trademarks or registered trademarks of their respective companies. Product features and specifications are subject to change without notice. Part Number: 910412 Rev. C

Kurzweil International Contacts Contact the nearest Kurzweil office listed below to locate your local Kurzweil representative. Kurzweil Co., Ltd. 178-353 Gajwa-dong Seo-gu, Incheon, Korea Tel: 82-32-580-1500 Fax: 82-32-584-4863 A N D Music Corp. 10107 S. Tacoma Way, A3 Lakewood, WA 98499, USA Tel: (253) 589-3580 Fax: (253) 589-3585 Young Chang Canada Corp. 250 Victoria Park Ave. Suite # 105 Toronto, Ontario Canada M2H 3P7 Tel: (905) 948-8052 Official distributors in other countries are listed on our website. World Wide Web Home Page http://www.kurzweilmusicsystems.com These Installation Instructions are valid for both the 88-key PC1x and the 61-key PC161 models. For statements that apply equally to both models, the generic name, PC1, will be used. Otherwise the specific model name, either PC1x or PC161, will be used.

Contents of the Kit Thank you for purchasing a PCR-2 ROM Expansion Kit for the PC1. The PCR-2 for the PC1 provides an array of classic keyboard sounds, and adds 128 programs and 32 setups to your PC1. Please read all of the introductory information in this document (through Tools and Materials Required for Installation) before proceeding with the installation. Finally, go to Updating Software on page 7 to update your PC1 software. Contents of the Kit In addition to this installation guide, your PCR-2 kit should contain the following items: Expansion board (single inline memory module, or SIMM) CD containing updated PC1 software Keyboard overlay with ROM2 sound categories, cut to fit over the Sound Select buttons on the PC1 s front panel User s Guide describing new software features, as well as information about programs and setups Safety Precautions To prevent risk of electrocution, make sure that the PC1 is disconnected from its power supply before you begin disassembling the instrument. Static electricity, even in small amounts, can cause damage to electronic components (especially memory). Before disassembling the instrument, touch a conductive metal surface to discharge any static electricity that you may have built up. Saving Your Data You may be upgrading your PC1 s software as part of this installation, which means that you ll need to do a hard reset before returning to normal operation. The hard reset initializes the PC1 so that it can use the new sounds and programs. It also deletes all userdefined data (programs, setups, and effects) from the PC1 s memory. If you don t want to lose your user data when you install this option, do a SysEx dump of all objects before you begin the installation. 3

System Requirements System Requirements If your instrument is a PC1x, it must have OS version 2.0 or later in order to work correctly with ROM 2. The PC161 supports ROM 2 from OS version 1.0. If you do not need to update your software, proceed to the installation procedure (page 6). 4 Checking Software Versions There are two ways to check the version of the operating system software. The first is to watch the display as the instrument powers up. During powerup, the display shows several messages. One of these messages is Welcome to the PC1x or PC161; this message also indicates the version of the operating system software on the bottom line of the display. The second way to check the version of the operating system software is to check the value of the OS Version parameter in the Global menu. Press the Global button, then press the Right cursor button until you see a parameter called OS Version. If you do not see this parameter, then you will need to update your OS software. Whichever method you use, if the operating system version is earlier than 2.0 and you have a PC1x, you need to update your operating system software. See page 7. Tools and Materials Required for Installation #2 (medium) cross-recess (Phillips head) screwdriver Two thick foam pads (keyboard models only) You ll need a flat work area large enough to accommodate the disassembled instrument. The foam pads listed in the required materials will protect the Alpha Wheel and knobs on keyboard units. Tools and Materials Required for Software Updates If you need to update your operating system software, you ll also need the following: Stand-alone sequencer or MIDI file player that has a CD-ROM drive and can send System Exclusive (SysEx) data or a personal computer (either Windows-compatible or a Macintosh or other computer capable of reading DOS disks and files)

Tools and Materials Required for Installation equipped with MIDI interface, CD-ROM drive, and sequencing software capable of sending SysEx data. MIDI cable If you do not have a device with a CD-ROM drive, you can download the files from our website, www.kurzweilmusicsystems.com. Sequencer Software for Windows-Compatible Computers Shareware/Freeware Windows Media Player. You need to have version 5 or later of Media Player older versions will not work correctly. You can download Windows Media Player from the following website http://www.microsoft.com/windows/windowsmedia/ download/default.asp Please note that Alesis Freeloader, which we recommend for the Mac, is buggy in the PC version and will not work correctly. Commercial software Logic (from EMAGIC) Sequencer Software for Macintosh Computers Shareware/Freeware Alesis Freeloader is available at the following website: http://www.alesis.com/downloads/software/ freeloader Please note that Windows Media Player, which we recommend for the PC, is buggy in the Mac version and does NOT work. Commercial software Performer (from Mark of the Unicorn) Logic (from EMAGIC) 5

Installing in the PC1 Installing in the PC1 Removing the Access Panel 1. Make sure that the PC1 is disconnected from its power supply, and that you ve discharged any residual static electricity by touching a conductive object (like the metal casing of the PC1 itself). 2. Position the foam pads on your work surface so that they ll support the ends of the keyboard. 3. Place the PC1 face-down on the foam pads, with the keyboard facing away from you. Make sure that the PC1 is not resting on the Alpha Wheel or sliders. 4. Using a #2 Phillips screwdriver, remove the seven screws that secure the access panel. 5. Remove the access panel by lifting its far edge and pulling it up and away from you. Installing the PCR-2 Board on the Engine Board This section describes the basic installation. 1. Locate the SIMM socket. It is about 4 long and near the front of the access slot. 2. Grasp the board so that the chips face away from you when you insert the connecting edge of the board into the socket. Notice the semi-circular notch at the center of the connecting edge. This notch aligns with a key on the SIMM socket, and ensures that you position the board correctly in the socket. 3. Place the board in the connection slot of the SIMM socket, aligning the notch in the board with the key in the socket. The board will rotate toward you when you release it. 4. Press straight down on the top edge of the board until the locking tabs at each side of the socket snap into place. Reassembly and Hardware Verification 1. Replace the access panel, and replace the retaining screws. 6

Updating Software 2. Turn the PC1 on, and watch the display. The display should show Welcome to the PC1x or PC161, then should go to the program mode. 3. Press the Global button, then press the Right cursor button repeatedly to scroll through the parameters until you find the parameter named Expansion, which should have a value of Yes. If the value of the Expansion parameter is No, the PCR-2 board isn t installed properly on the main engine board. You should repeat the installation procedure or consult a Kurzweil dealer or certified service center. Updating Software If you have not checked the software versions yet, you should do so now. If your instrument is the PC1x, the Classic Keys option requires version 2.00 or higher. The PC161 do not need to update the software. See System Requirements on page 4 to learn how to check software versions. You update your OS by using a sequencer application to load a MIDI file(.mid) into the PC1 s flash ROM. The file is named pc1x200.mid. The version number is indicated by the last three digits in the filename. A more recent version would have a higher number in the filename. Saving Objects Updating software components requires you to do a hard reset before resuming normal operations. This deletes all user-defined information from the PC1 s memory. You should dump all userdefined programs, setups, and effects to an external storage system (like a computer sequencer) before updating your software. Otherwise, they ll be lost. See the programming chapter in your PC1 Musician s Guide for information about dumping programs and other objects. Preparing Your Sequencer You ll need either a standalone sequencer, or a personal computer with a MIDI interface and sequencing software. 7

Updating Software 1. Connect a MIDI cable from your sequencer s or computer s MIDI Out port to the PC1 s MIDI In port. 2. Launch the sequencer application. Launching the PC1 s Boot Block You ll need to run the boot block for any software updates you make (including updating the boot block itself). 1. If the PC1 is on, turn it off. 2. Turn the PC1 on, and watch the display. 3. When you see Please wait..., press and release the Panic button. After a few seconds, you ll see Install FlashROM via MIDI. This is the boot block. 4. Follow the instructions below. Updating Operating System The operating system software, together with the soundware data, are part of the PC1 sound engine. You ll use the Install FlashROM via MIDI (sound engine) option to install both the operating system software and the soundware. 1. If the boot block is not already running, launch it as described above. 2. When the boot block has finished launching, the display shows Install engine via MIDI. 3. Press Yes again. The display changes to Waiting for MIDI. 4. If necessary, insert the PC1 CD into the sequencer s or computer s CD-ROM drive. 5. Find and open the appropriate MIDI file for your PC1. The version number (last three digits) must read 200 or higher. 6. Play the MIDI file. The top line of the display shows SYS3-0 file 1 of 1, and the bottom line shows segment 1 of 31. When the display shows Done, stop the sequencer if it doesn t stop automatically. As soon as you see Done, you can go on to the next step. 8

Updating Software 7. Proceed to Doing a Hard Reset below. Doing a Hard Reset This procedure assumes that you re in the boot block menu. If you aren t, relaunch the boot block (see page 8 if you need a reminder), then proceed. 1. Press the Left or Right cursor button until you see Hard RESET in the bottom line of the display. 2. Press Yes. The display prompts you with a question: Erase RAM objects? 3. Press the Right cursor button. This performs the hard reset and returns you to the boot block menu. 4. Follow the instructions in Returning to Normal Operations From the Boot Block Menu below. Returning to Normal Operations From the Boot Block Menu 1. Press the Left or Right cursor button until you see Run engine in the bottom line of the display. 2. Press Yes. After a few seconds, you ll be back in performance mode. You re now ready to verify the software installation. Verifying the Software Installation This procedure assumes that you ve properly installed the hardware portion of the PCR-2 option, verified the installation (as described on page 6), executed a hard reset, and returned to a performance mode. 1. Press the Global button to enter the menu of global parameters. 2. Press the Right cursor button repeatedly until you see the parameter named OS Version. The version number in the display should match the version number in the name of the operating system file you installed (the version must be 2.0 or later for the PCR-2 option to work with the PC1x). See the troubleshooting section below if any of the steps in the verification procedure gave you the wrong result. 9

Updating Software Troubleshooting for Software Updates You re not likely to have problems updating your software. In fact, there are very few things that can go wrong: Display is Stuck at Waiting for MIDI The MIDI signal isn t getting to the PC1. Make sure that the computer or sequencer s MIDI Out is connected to the PC1 s MIDI In. Make sure the cable isn t defective. Try another cable if necessary. Display Never Shows Done It s possible that the PC1 isn t receiving all of the MIDI file data. Try playing the MIDI file at a slower tempo. It s also possible that there s an issue with your MIDI interface. Installing the latest version of your interface s USB driver (available from the interface s manufacturer) may help. You might also try a different MIDI interface. Version in Display Doesn t Match Version of File If the version number you see in the display doesn t match the version number on the file you installed, the file didn t get installed properly. Try installing the file again. Watch the display carefully to make sure the instrument is receiving data from the sequencer. make sure that you see Done in the display before stopping the playback of the file. If you downloaded or copied any of the files, one or more of them may be corrupted. Try downloading the files again. The address for the Kurzweil website is www.kurzweilmusicsystems.com. If you re still having problems, consult a Kurzweil dealer or service center. 10