Intelligent Containment Systems

Similar documents
Product Overview. Geist Americas 1821 Yolande Ave. Lincoln, NE USA Tel:

Cooling Case Studies

From Power Strips to DCIM Solutions

Geist designs and manufactures intelligent hardware and software for the four cornerstones of data center management:

About Geist. geistglobal.com

High Tech Getting Too Hot? High Density Environments Require A Different Cooling Approach

Cooling Case Studies

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Data Center Enclosures Best Practices. Maximize the Efficiency of the Enclosure within a Data Center

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet

The Four 4R s. of Data Center Airflow Management. About Upsite Technologies

Switched, Outlet Level Monitoring

1.866.TRY.GLCC WeRackYourWorld.com

RCOBN PH6TL21-D Power Monitoring, Outlet Level. Part Number

Thermal management. Thermal management

Real-Time Monitoring: Understanding the Commonly (Mis)Used Phrase

G GRCOW PH6PS6-D-IP44 Power Monitoring, Outlet Level. Part Number

Cabinet Level Containment. IsoFlo Cabinet. Isolated Airfl ow Cabinet for Raised Floor Data Centers

ENCLOSURE HEAT DISSIPATION

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden

Containment Accessories Floor Mounting Template

APC APPLICATION NOTE #74

LCP Hybrid Efficient performance with heat pipe technology

survey, 71% of respondents listed Improving capacity planning as a top driver for buying DCIM 1.

Reducing Energy Consumption with

APC APPLICATION NOTE #146

Reverse Flow Cabinet. ContraFlo Cabinet. Reverse Flow Cabinet for Raised Floor Data Centers

Environmental Monitor (RSMICRO)

Power and Cooling for Ultra-High Density Racks and Blade Servers

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

To Fill, or not to Fill Get the Most out of Data Center Cooling with Thermal Blanking Panels

HIGHLY EFFICIENT COOLING FOR YOUR DATA CENTRE

Geist EMEA. Geist USA. Geist APAC

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Total Modular Data Centre Solutions

Data Centre Products. Airflow Management Solutions

Rittal Cooling Solutions A. Tropp

Reclaim Wasted Cooling Capacity Now Updated with CFD Models to Support ASHRAE Case Study Data

MSYS 4480 AC Systems Winter 2015

Design and Installation Challenges: Aisle Containment Systems

Reducing Data Center Cooling Costs through Airflow Containment

Switch to Perfection

Improving Data Center Efficiency

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

RiMatrix S Make easy.

Effectiveness and Implementation of Modular Containment in Existing Data Centers

A Green Approach. Thermal

Recapture Capacity for Existing. and Airflow Optimization

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

Fundamentals of CFD and Data Center Cooling Amir Radmehr, Ph.D. Innovative Research, Inc.

INNOVATE DESIGN APPLY.

POWER AND THERMAL MANAGEMENT SOLUTIONS

WIRELESS ENVIRONMENTAL MONITORS

» BEST PRACTICES FOR AIRFLOW MANAGEMENT AND COOLING OPTIMISATION IN THE DATA CENTRE

Power Monitoring in the Data Centre

Virtualization and consolidation

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model

INNOVATE DESIGN APPLY.

DATACOM CABINETS SOLUTION GUIDE

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Perfect Cooling. A perfect climate for high performance servers

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Data center solutions for successful companies Cooling solutions

ENCLOSURE THERMAL TESTING HEAT REMOVAL IN THE REAL WORLD

Running Your Data Center Under Ideal Temperature Conditions

Google s Green Data Centers: Network POP Case Study

Impact of Air Containment Systems

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

Air Containment Design Choices and Considerations

Optional Remote Sensors - Connect via RJ12 Standard sensor lengths include 12 and 20. Custom lengths available upon request. Temperature:

Optimizing Cooling Performance Of a Data Center

Avoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms

Liquid Cooling Package LCP Cooling Systems

Taking The Heat Off University of East Anglia Data Centre

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

Optimization in Data Centres. Jayantha Siriwardana and Saman K. Halgamuge Department of Mechanical Engineering Melbourne School of Engineering

How to Increase Data Center Efficiency

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc

APC InfraStruXure Solution Overview

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

Data Center Airflow Management Basics: Comparing Containment Systems

SmartAisle. SmartAisleTM. Energy-efficient use of existing cooling power in data centers to

MEASURE MONITOR UNDERSTAND

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Great Lakes Product Solutions for Cisco Catalyst and Catalyst Switches: ESSAB14D Baffle for Cisco Catalyst 9513 Switch

Using CFD Analysis to Predict Cooling System Performance in Data Centers Ben Steinberg, P.E. Staff Applications Engineer

A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems.

APC APPLICATION NOTE #114

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

DAX Directional Airflow exhaust system. Energy efficient heat removal and redistribution. Product overview and technical data

Data Centre Solutions. stableair. Solutions To Cut Cooling Energy Costs

Variable Density, Closed-Loop, Water-Cooled Data Center Solution

Rethinking Datacenter Cooling

Liebert DCW CATALOGUE

RE Series Rack from Eaton Product Presentation

Comprehensive Data Center Energy Management Solutions

PLAYBOOK. How Do You Plan to Grow? Evaluating Your Critical Infrastructure Can Help Uncover the Right Strategy

DC Energy, Efficiency Challenges

Transcription:

Intelligent Containment Systems

About Geist Geist designs and manufactures industry leading technology and software for powering, monitoring, cooling and managing critical data center infrastructure. We produce affordable, quality products while providing our clients with superior service. Whether it s enhancing customer care services or implementing new technologies, Geist promotes innovation, quality and satisfaction in all aspects of business. 877.449.4150 geistglobal.com

Maximize cooling efficiency and easily maintain a perfectly controlled temperature. Air Management Systems Opengate solutions offer sophisticated airflow management to data centers of any size and capacity. By containing and directing hot air, the Opengate line delivers significant cost savings while improving the long-term reliability of missioncritical IT equipment. Maintains a perfectly controlled and consistent IT environment Maximizes effi ciency while maintaining an ideal temperature throughout data centers Contains and evacuates 100 percent of the heat so no hot air mixes with cool air Exhausts heat directly from the cabinets, eliminating hotair bypass Maximizes chiller plant effi ciency with the highest possible return air temperatures Eliminates temporary fi xes like vinyl plastic sheeting with expertly manufactured chimneys and rack enclosures Intelligent fan units respond when sensors recognize a fl uxuation in demand. -2- geistglobal.com

COOL Airflow Assessment Program Geist s highly trained team of experts conduct a thorough site survey to identify key airflow trouble spots and recommend viable solutions in a customized Airflow Assessment Report. This assessment provides detailed insight into the efficiency of a data center's cooling circuit and summarizes the necessary steps to maximize cooling efficiency. Assessment ROI It s estimated that for every watt of power consumed by IT equipment in an average data center, another watt is required to remove the heat generated by that equipment. Based on this principle, significant cost savings can be achieved by implementing all or a portion of the steps prescribed in the Airflow Assessment Report. In addition to targeting airflow problem spots, Geist s assessment clearly calculates the estimated return on investment from the suggested recommendations. Indirect monetary benefits like improved reliability of equipment and upgraded working conditions are also included in the report. Geist s Airflow Assessment Report specifies the many overall benefits of effective airflow management. Assessment Team For more details on conducting an Airfl ow Assessment in your data center, contact one of Geist's cooling experts at 800.432.3219 or sales@geistglobal.com. Studies show 250 percent over-cooling is required when hot air is uncontrolled.* Without heat containment, hot air mixes with cold, leading to gross over-cooling. Opengate addresses this problem by focusing on containing hot air to improve cooling effi ciency by up to 40 percent. * ""Designing Better Data Centers"," ASHRAE Journal, 12/07, EPA - Uptime Institute conference material 800.432.3219-3-

Provides automated feedback to help cut total fan energy by 40 percent. Intelligent Cabinet or Row Containment The Opengate Intelligent Containment System centers on two critical components: 1) containing heat and 2) expelling heat directly to the Computer Room Air Conditioning (CRAC) units. This two-step focus maintains and stabilizes the ideal temperature for data center equipment. Fan controller The first step is addressed by Opengate s expertly manufactured chimneys and enclosures. The second step relies on sophisticated temperature and pressure sensors to control fan speeds and exhaust hot air through the chimneys at the most efficient rate. The combination of hot air containment and intelligently controlled fan speeds creates a consistent climate-controlled environment in the data center and within the cabinet rows. Opengate is available for virtually every new or existing cabinet model and confi guration. Geist has developed a vast library of cabinet-specifi c installation kits that include cabinet tops, blanking panels and mounting hardware. If a new cabinet or row confi guration is required, Geist s team of design engineers will deliver a solution in days. Pressure sensor Pressure sensor information is fed into the controller, which is then translated into commands that raise or lower fan speeds based on the server load. Part number EC00D SYSTEM EC10D SYSTEM EC10R SYSTEM EC20D SYSTEM EC20R SYSTEM EC30R SYSTEM EC1001C EC1001CT EC1002-0007X EC1002-0013X EC1002-08S EC1002-12S EC1002-24S EC1002-48S EC1001H EC10D EC20D EC30R Description (See page 4 for detailed descriptions.) Passive Heat Containment System Containment Cooling System includes Chassis, Host Controller with Pressure Sensor and (2) EC10D fan cartridges Row Containment Cooling System includes Chassis, Host Controller with Pressure Sensor and (2) EC10D fan cartridges Containment Cooling System includes Chassis, Host Controller with Pressure Sensor and (2) EC20D fan cartridges Row Containment Cooling System includes Chassis, Host Controller with Pressure Sensor and (2) EC20D fan cartridges Row Containment Cooling System includes Chassis, Host Controller with Pressure Sensor and (2) EC30D fan cartridges EC Base Chassis, 7.5 inches EC Base Chassis tall, 11.5 inches Duct Extender extends duct an additional 0-7 inches Duct Extender extends duct an additional 0-13 inches EC System Duct, 8 inches, stackable EC System Duct, 12 inches, stackable EC System Duct, 24 inches, stackable EC System Duct, 48 inches, stackable EC Host Controller, includes pressure sensor and mounting bracket Fan cartridge for use in EC 10D System Fan cartridge for use in EC 20D System Fan cartridge for use in EC 30D System -4- geistglobal.com

COOL A. Custom Chimney Opengate chimneys exhaust the cabinet s hot air through the ceiling return plenum or to other desired locations. Chimneys are adjustable to accommodate most ceiling heights. Durable and easy to assemble, each chimney is made of powdercoated steel, matching most data center cabinets. Adjustable duct extender kits: EC1002-0007X, EC1002-0013X Fixed length stackable ducts: EC1002-08S, EC1002-12S, EC1002-24S, EC1002-48S A B C C System Components EC00DT System EC20DT System EC30RT System B B. Fan Units Opengate fan cartridges evacuate hot air to maintain air fl ow at the exact rate the IT equipment generates. Each fan unit is manufactured with best-in-class components to ensure maximum run life and unparalleled effi ciency. EC10D, EC20D, EC30R C. Intelligent Controller The intelligent controller is the brains behind Geist's Enterprise Cooling (EC) system. It automatically adjusts fan unit speeds to exhaust exactly the right amount of air from each cabinet. The fan speed is controlled by information from pressure sensors that compare pressure inside cabinets with that in the room. The EC system works to maintain a zero differential between the two environments. The intelligent controller also logs and records valuable temperature and performance data. EC1001H 800.432.3219-5-

Opengate conforms to almost any environment to deliver intelligent cooling. Scalable Capacity System capacity automatically scales as loads are added or removed Automated load sharing returns all heat directly to return air plenum High-density loads can be directly coupled for single cabinet isolation Load sharing leads to lower cost per deployed kw, allowing all fans to run at energy effi cient speeds Load Sharing Multiple systems work together to share cabinet loads Operational redundancy increases as systems work in concert In the event of utility failure, heat continues to be exhausted by the Geist cooling unit using power provided by its PDU/UPS Geist's Environet software aggregates total airfl ow load and automates the process of defi ning requirements, allowing for a reduction of supply airfl ow across the data center. Automated Control Receive automatic notifi cation of system threshold breach via email or SNMP Environmental conditions are monitored and reported automatically IT intake air is stabilized within a few degrees of the supply air temperature at all points in the data center Optional placement of Geist cooling units avoids overhead obstructions such as cable trays. -6- geistglobal.com

COOL Passive Cabinet Containment Geist's Opengate is the most flexible cooling option on the market. With Opengate Passive Cabinet Containment, lowdensity cabinets can take advantage of a simple chimney solution to manage modest loads. Then, as cabinet loads increase, the passive system can be upgraded quickly to an Opengate Intelligent Containment System. It grows and adjusts to the needs of any data center with features like: System Components EC10DT System Efficient chimney systems For low-density cabinets (up to 4 kw) Heat is channeled directly to the hot air return no mixing with the cooler ambient air No active components relies on server fans to push exhaust Highly economical simple design is low cost and easy to install Occupies zero floor space mounted above the rack allows for maximum cabinet space Easily upgradable to an active system for higher density cabinets as density matures Removable blanking panels capture heat. As cabinets increase in density they can be upgraded to an Opengate Active Containment System. 800.432.3219-7-

Intelligent heat removal and monitoring solutions. Unity Cooling The Opengate Unity Cooling solution uses sensors and sophisticated software to integrate its row-based Intelligent Containment System with the data center s CRAC units. By establishing a link to the airfl ow requirement at the rack level, Unity Cooling controls the CRAC unit and delivers only the amount of cool air required by the data center. The fully automated system maximizes effi ciency by optimizing the amount of power required to maintain the appropriate temperature. The Unity Cooling solution saves up to 40 percent on power consumption. In addition, Unity Cooling gives you the advantage of: Scalability to adjust data center airfl ow to accommodate growth of additional servers and load for increased data center effi ciency Reporting coupled with the element of fan control to reduce fan power for better effi ciency IT Row Enclosure The Opengate Row Enclosure system encases an entire row of cabinets to completely contain heat and keep it from mixing with a data center's cold air. The enclosure includes Opengate's intelligent sensors and chimneys to exhaust heat directly to the CRAC. The system can be deployed in a variety of retrofi t or new construction confi gurations to meet your specifi c data center needs. Geist's IT Row Enclosure provides: Maximum effi ciency Effective control of thermal environment Flexibility to increase load from a few kw to 320 kw per row Automate cooling supply to match IT load -8- geistglobal.com

COOL Small Room Cooling Geist's RAC10 system evacuates heat from a small space and sends it to the outside corridor or ceiling plenum return. The unit allows the closet to breathe which leads to a perfectly controlled environment for your small computer and network rooms using building air. The unit interfaces with temperature sensors to adjust fan speeds as temperatures rise and fall while providing the needed visibility-to-cooling capacity, environmental information and alarms. Email alerts and the Web interface provide remote alerts and management for superior visibility and control of room environment. Opengate RAC10 The Opengate RAC10 system can be mounted to the wall or the ceiling for automated heat exhaust and critical monitoring and alerts. An optional Duct Kit can be added. The dimensions of the RAC10 fan enclosure are 21" W x 14" L. Wall Mount Ceiling Mount Ceiling Mount Wire Hanger Loop Cable Tie Loop Wall Stud Mounting Flange Optional Duct Kit Temp Sensor Port (4) Redundant Fans Internal Temp Sensor Ethernet RJ45 Power Input 800.432.3219-9-

Lower the operating temperature of network switches, load balancers and routers. Switch Cooling Network switches, load balancers and routers are often mounted in the back of a cabinet for more convenient cabling connections. Unfortunately, devices installed at the back of cabinets can be critically damaged or may go offl ine when they are fed pre-heated air from the servers. Opengate Switch Cooling addresses this issue by delivering cool air to network devices regardless of where they are mounted. Switch Cooling products are available in a wide range of confi gurations and rack space sizes. Designed to work with 1U to 9U devices and beyond, Opengate Device Cooling channels air to every kind of intake/exhaust confi guration imaginable. Network switches mounted at the top and rear of the rack are susceptible to heated air from the servers. This hot air is recirculated, putting stress on the device. Blanking Panels switch switch Active Opengate Switch Cooling products are confi gured to accommodate numerous intake/exhaust confi gurations. Passive Opengate Switch Cooling directs cool air to the network switches, signifi cantly lowering operating temperatures. switch switch Opengate Switch Cooling guides cool air to network devices mounted in non-ideal locations within the cabinet. In many cases this can be done with a simple passive device. Active fans may be incorported as confi guration, size and airfl ow requirements demand. -10- geistglobal.com

COOL Upsite Airflow Management Accessories KOLDLOK Raised Floor Air Management Model # Image Description Wave Grommet 20100 Seals openings in new and existing raised fl oor cutouts prior to the installation of cabling. Wave-shaped thermoplastic elastomer offers the best sealing against bypass airfl ow. Wave Cover 20101 Safety cover seals Wave Grommet when cables are not present. Integral 1010 Install prior to installation of cables. Split Integral 3030 Split design for easy install without disturbing existing cables. Surface Mount Original Grommet 2020 Surface Mount Large Grommet 2030 Seals a variety of existing raised fl oor tile cutouts and allows fl exibility to remove tiles without capturing cables. Surface Mount Extra Large Grommet 2040 Mini Grommet 10077 Smaller size 6 x 4 offers fl exibility for data centers that have multiple cable opening sizes. 3 Extended Brush 10012 6 Extended Brush 10013 Seals new and existing openings. Simple modifi cation creates the fl exibility to seal large and unique openings such as those found under PDUs. 4 Round Floor Grommet 40001 The split feature allows product installation or removal without disturbing cables. Hybrid brush technology membrane and bristles create extremely effective seal. HOTLOK Rack Airflow Management Model # Image Description 1U Blanking Panel 10031 2U Blanking Panel 10033 Cantilevered sealing vanes eliminate the gap between adjoining blanking panels or with installed equipment. Tool-free, snap-in installation requires no additional parts or components for installation. 1U Temp Strip Blanking Panel 10035 2U Temp Strip Blanking Panel 10038 Color-coded temperature ranges indicate potential hot spots by color based on ASHRAE standard. Easy-pull removal for any EIA-310-E standard openings. Round 4 Rack Mount Grommet 40002 Seals 4 cable openings without disturbing the cables in new and existing server rack cutouts. 1U Pass Through Blanking Panel 10112 2U Pass Through Blanking Panel 10113 Provides an effective airfl ow sealing solution when used in conjunction with pullout KVM switches or servers that may be occasionally extracted. Also provides rack sealing where cables prevent solid blanking panels from being installed. AISLELOK Airflow Management Model # Image Description Under Rack Panel 10103 25 x 4 x 3 under rack panel seals a variety of openings below the rack on new and existing raised server racks..5 Acrycell Tape 1 Acrycell Tape 2 Acrycell Tape 4 Acrycell Tape 10108-001 10108-002 10108-003 10108-004 Seals openings between racks in new and existing data center aisles. Designed to block bypass airfl ow and maximize cooling system effi ciency. Time release expansion ensures a tight seal around cables and other impediments. Customizable tape unrolls, creating one continuous and uniform top-to-bottom seal. 800.432.3219-11-

Geist Americas 1821 Yolande Ave. Lincoln, NE 68521 USA 800.432.3219 Tel: 402.474.3400 Geist DCiM 2290 East Prospect Rd, Ste. 6 Fort Collins, CO 80525 USA Tel: 877.449.4150 Geist Europe Unit 1, The Monarch Centre Venture Way Priorswood, Taunton Somerset, TA2 8DE UK Tel: +44 (0)1823.275100 Geist Asia China Tiley Plaza Bldg A, Unit #2808 No.199 Haide 3 Road Nanshan, Shenzhen Guangdong Province, China Postal Code 518000 Tel: +86.755.86639505 Geist Asia Hong Kong salesasia@geistglobal.com Tel: +852.90361927 geistglobal.com 20000402