PHOENIX CONTACT - 07/2006

Similar documents
PHOENIX CONTACT - 01/2007

QUINT-BUFFER/24DC/24DC/40

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

TRIO-DIODE/12-24DC/2X10/1X20

Extract from the online catalog

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

QUINT-PS-3x AC/24DC/10

STEP-PS/1AC/24DC/1.75

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

MINI-PS AC/10-15DC/8

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

QUINT-PS AC/24DC/10

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

QUINT-PS/ 1AC/24DC/ 5

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

QUINT-DC-UPS/24DC/40. Extract from the online catalog. Order No.:

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

Redundancy Module QUINT-DIODE/40

UNO-PS/1AC/12DC/30W. Primary-switched power supply unit. Data sheet. 1 Description

ASI QUINT /2.4 EFD

onlinecomponents.com

1-Phase Power Supply, Primary Switch Mode for Use in Potentially Explosive Areas QUINT-PS AC/24DC/5/EX

Uninterruptible Power Supply Unit for Universal Use QUINT-DC-UPS/24DC/40

STEP-PS/1AC/24DC/2.5. Extract from the online catalog. Order No.: DIN rail power supply of 24 V DC/2.5 A, primary switched, single phase.

QUINT-PS/24DC/48DC/ 5

QUINT-PS/ 1AC/24DC/20/CO

Power supply CP-C 24/5.0

Power Supply HARTING pcon

MINI MCR-SL-UI-2I(-SP)(-NC)

Uninterruptible power supply - TRIO-UPS/1AC/24DC/

Power Supply HARTING pcon

Redundancy unit CP-A RU

RTU500 series Data Sheet Power Supply CP-E 24/2.5

MINI MCR-SL-PT100-UI(-SP)(-NC)

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

Power supply CP-E 24/10.0 Primary switch mode power supply

Power supply CP-E 24/0.75 Primary switch mode power supply

Power supply CP-E 48/1.25 Primary switch mode power supply

FL MC 2000E (SM40) LC

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

DC/DC converters - QUINT-PS/24DC/24DC/

EMD-SL-LL-230. Electronic monitoring relay for level monitoring of conductive liquids. INTERFACE Data sheet _en_04. 1 Description.

PHOENIX CONTACT Features

Power supply CP-D 12/2.1 Primary switch mode power supply

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

PHOENIX CONTACT - 05/2007

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range)

MINI MCR-SL-UI-REL(-SP)

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

ETD-BL-1T-OFF-CC- 10S

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

PI-EX-ME-2NAM/COC-24VDC

MINI MCR-SL-PT100-UI-200

PHOENIX CONTACT - 12/2007

PI-EX-ME-2NAM/COC-120VAC

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

MINI MCR-SL-CVS NC

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

QUINT-UPS/ 24DC/ 24DC/10

AO561 Analog Output Module

AI561 Analog Input Module

Power supply CP-C 24/5.0

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

onlinecomponents.com

20A DRR Module / 40A DRR Module

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

Redundancy unit CP-D RU Accessory for CP range power supplies (e.g. switch mode power supplies CP-D range)

AO523 Analog Input Module

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

TU531, TU532 Terminal Unit

DC561, digital input/output module,

PHOENIX CONTACT - 10/2009

PSR-PS21. SIL coupling relay. Data sheet. 1 Description

This data sheet is only valid in association with the IL SYS INST UM E user manual.

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

Industrial Power Supplies

DI561 Digital Input Module

DC562, digital input/output module,

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

Valueline Industrial PC

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

Installation / Control Technique

DI572 Digital Input Module

Output Voltage* (nom.)(adjustable)

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

PHOENIX CONTACT - 11/2008

Transcription:

Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER, a maintenance-free buffer module on a capacitor basis. Systems can therefore also run in unstable networks or are, in the event of failures of a longer duration, correctly shut down after all relevant process data is saved. The bridging time is 200 ms at 20 A and 4 s at 1 A. The buffer module also acts as a power storage device for peak loads and for triggering fuses. For function monitoring, an active switching output and a control lamp are used. With the integrated diode, loads can be divided into buffered and unbuffered loads. Thus, the buffer period is extended and the buffered consumers are protected against errors in the internal network. Maintenance-free due to capacitor-based power buffer The slim design saves space on the DIN rail High system availability due to clear signaling Extended buffer period for critical loads through decoupled input Danger! Components with dangerously high voltage and high stored energy are located in the device! Never carry out work on live parts! Depending on the ambient temperature and the load, the housing can become very hot! Make sure you always use the the latest documentation. It can be downloaded at www.download.phoenixcontact.com. A conversion table is available on the Internet at www.download.phoenixcontact.com/general/7000_en_00.pdf.

Order data Description Type Order No. Pcs./Pkt. Buffer module with maintenance-free capacitor-based power storage device QUINT-BUFFER/24DC/20 2866213 1 Accessories Type Order No. Pcs./Pkt. Universal wall adapter UWA 182/52 2938235 1 Technical data Input data Nominal input voltage 24 V DC DC input voltage range 22.5 V DC... 30 V DC Buffer period 0.2 s (20 A) 4 s (1 A) Charging time < 27 s Current consumption 0.1 A (idling) 0.6 A (charging process) 20.6 A (max.) Protection against polarity reversal Yes Charging delay No Connect threshold < 22 V DC (fixed) (U IN - 1 V)/0.1 s (variable) Protective circuitry Transient surge protection Suppressor diode, 35 V DC Input fuse, integrated (slow-blow, internal) Output data Nominal output voltage 24 V DC (depending on the input voltage) Setting range of the output voltage 22 V AC... 28.5 V AC Buffer voltage U IN - 0.8 V and > 22.0 V Output current 20 A Output current limit 27 A (buffer mode) Max. transit current 27 A (at 40 C) 20 A (at 70 C) Disconnect > 4.5 s (buffer mode) loss 2.5 W (ready at 27 A) 9.8 W (buffer mode at 27 A) Efficiency > 95 % (at 27 A) Residual ripple < 100 mv SS (buffer mode) Peak switching voltages < 100 mv SS (20 MHz) Connection in parallel Yes, for increasing the buffer time and for redundancy Surge protection against internal surge voltages Yes, limited to approx. 35 V DC Resistance to reverse feed < 35 V DC (buffer mode) Status indication Status display LED " ", green Buffer module is loaded: LED ON 102035_03_en PHOENIX CONTACT 2

Signal output Active (high = buffer module is loaded) Output description Continuous current Output voltage +20 ma +24 V Standards Electrical Equipment for Machinery EN 60204 Safety transformers for power supply units EN 61558-2-17 Electrical safety (of information technology equipment) EN 60950/VDE 0805 (SELV) EN 61558-2-17 UL/C-UL recognized UL 60950 Industrial control equipment UL/C-UL Listed UL 508 Shipbuilding German Lloyd, ABS Electronic equipment for use in electrical power installations EN 50178/VDE 0160 SELV EN 60950 (SELV) and EN 60204 (PELV) Safe isolation DIN VDE 0106-101 Approvals Granted approvals Granted approvals for potentially explosive areas u F ABS U General data Insulation voltage input/output 1 kv (routine test) 1 kv (type test) Installation position Horizontal DIN rail NS 35, EN 60715 Degree of protection IP20 Class of protection III, without PE connection MTBF > 500 000 h in acc. with IEC 61709 (SN 29500) Housing version AluNox (AlMg1) Width 64 mm Height 130 mm Depth 125 mm Width with alternative assembly 122 mm Height with alternative assembly 130 mm Depth with alternative assembly 67 mm Weight 1 kg Climatic data Ambient temperature (operation) -25 C... 70 C Ambient temperature (storage/transport) -40 C... 85 C Max. permissible. relative humidity (operation) 95 % (at 25 C, no condensation) Vibration (operation) < 15 Hz, amplitude ±2.5 mm in acc. with IEC 60068-2-6 15 Hz... 150 Hz, 2.3g, 90 min. Shock 30g in all directions in acc. with IEC 60068-2-27 Pollution degree in acc. with EN 50178 2 Climatic class 3K3 (in acc. with EN 60721) 102035_03_en PHOENIX CONTACT 3

Conformance with EMC directive 89/336/EEC Immunity to interference in acc. with EN 61000-6-2 Discharge of static electricity in acc. with EN 61000-4-2 Housing Level 4 Contact discharge 8 kv Discharge in air 15 kv Comments Criterion B Electromagnetic HF field in acc. with EN 61000-4-3 Housing Level 3 Frequency range 80 MHz... 1 GHz Field intensity 10 V/m Comments Criterion A Fast transients (burst) in acc. with EN 61000-4-4 Input 2 kv (level 3 - asymmetrical: conductor to ground) Output 2 kv (level 3 - asymmetrical: conductor to ground) Signal 1 kv (level 2 - asymmetrical: conductor to ground) Comments Criterion B Surge voltage capacities (surge) in acc. with EN 61000-4-5 Input/Output/Signal 0.5 kv (level 1 - asymmetrical: conductor to ground) 0.5 kv (level 1 - symmetrical: conductor to conductor) Comments Criterion B Conducted disturbance in acc. with EN 61000-4-6 Input/Output/Signal Level 3 Frequency range 0.15 MHz... 80 MHz Voltage 10 V Comments Criterion A Emitted interference in acc. with EN 61000-6-3 Radio interference voltage in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential Emitted radio interference in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential Note: Criterion A: Normal operating behavior within the defined limits. Criterion B: Temporary impairment to operational behavior that is corrected by the device itself EN 55011 corresponds to CISPR11 / EN 55022 corresponds to CISPR22 EN 61000 corresponds to IEC 1000 Block diagram Input Output 102035_03_en PHOENIX CONTACT 4

Structure 1 - DC input 2 - DC output 3 Control lamp " " 4 Switching output active 5 - DIN rail adapter 6 - Switch DYNAMIC ON/OFF 4 QUINT BUFFER GND 5 3 DC 24 V Input 20 A Output 1 + + 2 6 [mm 2 ] AWG [Nm] solid stranded Torque Input 0.5-16 0.5-10 20-6 1.2-1.5 Output 0.5-16 0.5-10 20-6 1.2-1.5 signal 0.2-2.5 0.2-2.5 24-12 0.5-0.6 Input data Nominal input voltage DC input voltage range Input fuse, integrated Type of connection Stripping length Output data Nominal output voltage Setting range of the output voltage Output current Type of connection Stripping length 24 V DC 22.5 V DC... 30 V DC (slow-blow, internal) Screw connection 10 mm 24 V DC (depending on the input voltage) 22 V AC... 28.5 V AC 20 A Screw connection 10 mm 102035_03_en PHOENIX CONTACT 5

DC 24 V Input QUINT-BUFFER/24DC/20 Safety and warning notes The power supply units are built-in devices. The device may only be installed and put into operation by qualified personnel. The corresponding national regulations (e.g. VDE, DIN) must be observed. Installation Danger! Components with dangerously high voltage and high stored energy are located in the device! Never carry out work on live parts! Depending on the ambient temperature and the load, the housing can become very hot! Before startup please ensure: The mains connection has been carried out by a competent person and protection against electric shock is guaranteed! All feed lines are sufficiently protected and dimensioned! All output lines are dimensioned according to the maximum output current of the device or separately protected! Sufficient convection is guaranteed! In order for the device to function in the manner intended. it is not necessary to observe any minimum spacing to other devices. The power supply unit can be snapped onto all DIN rails in acc. with EN 60715. They must be horizontal (connecting terminal blocks below). QUINT BUFFER GND 20 A Output + + 102035_03_en PHOENIX CONTACT 6

Installation position 64 125 QUINT BUFFER GND 130 DC 24 V 20A Input Output + + Slim-style installation: Installation depth 125 mm (+ DIN rail) (state at delivery) Low-profile installation: Installation depth 67 mm (+ DIN rail) Slim-style installation: Assembly Position the module with the DIN rail guide on the upper edge of the DIN rail, and snap it in with a downward motion. Dismantling Pull the snap lever open with the aid of a screwdriver and slide the module out at the lower edge of the DIN rail. 102035_03_en PHOENIX CONTACT 7

Low-profile installation: Low-profile installation can be achieved by mounting the device at right-angles to the DIN rail. Mount the DIN rail adapter (UTA 107) as described in the figure. No additional mounting material is required. Fixing screws: Torx T10 (torque 0.8 Nm... 0.9 Nm). Input AC DC + Supply QUINT BUFFER 4-POL QUINT BUFFER 4-POL Unbuffered Load Buffered Load The buffer module is connected at the output of the power supply via the "+" and "-" screw connections of the 24 V DC input (connection as 4-pos.). The output is decoupled from the input by means of the internal diode. The stored power is only delivered at the output (see figure). If no decoupling is required, the buffer module can also be connected to the power supply as a 2-pos. connection via the "+" and "-" connections of the DC output (see figure). Protection of the primary side AC DC+ Supply DC + QUINT BUFFER 2-POL QUINT BUFFER 2-POL Buffered Load Device installation must be carried out according to the regulations in EN 60950. For device protection, there is an internal fuse. Additional device protection is not necessary. If an internal fuse is triggered, there is most probably a malfunction in the device. In this case, the device must be inspected in the factory! 102035_03_en PHOENIX CONTACT 8

Output All loads that, in the event of a failure of the supply voltage, are to be supplied with power stored in the buffer module, ("Buffered Load"), are connected to the "+" and "-" of the DC output. We recommend that all other loads not requiring buffering in the event of a failure of the supply voltage ("Unbuffered Load") should be connected parallel to the power supply unit. This extends the buffer time, as it depends on the output current (see figure). The internal diode guarantees that the buffered loads are decoupled from the unbuffered loads. Output voltage The output voltage of the buffer module is equal to the supply voltage connected. If the input voltage falls within 0.1 s by more than 1 V, the buffer is connected and the output voltage is regulated to this value. This dynamic detection can be disabled with switch "DYNAMIC ON/OFF". The minimum connect threshold is 22 V. The device is electronically protected against short circuit and idling. In the event of a malfunction, the output voltage is limited to 35 V DC. Signaling For function monitoring, there is the active signal output and an LED " ". The signal output is connected via the " " and "GND" screw connections. The 24 V DC signal can carry up to 20 ma. State 1 State 2 LED " " ON Flashing Active signal output " " U = +24 V (in reference to "-") U = 0 V (in reference to "-") Meaning 1. Supply voltage is present 2. Buffer module is charged 3. Buffer module is ready 1. There is supply voltage, buffer module is being charged Or 2. There is no supply voltage, the power store in the buffer module will be provided at the output (as long as is available) 102035_03_en PHOENIX CONTACT 9

Function For all connected loads, QUINT-BUFFER provides a regulated and uninterrupted 24 V DC voltage at the output for a load current of 20 A. Once the 24 V supply voltage has been applied, the integrated capacitor-based power storage device is charged. If the supply voltage fails, uninterrupted operation of up to 4 seconds for all connected loads is guaranteed with the stored power. buffer period [s] 10,0 1,0 1 2 3 Buffer time extension With the decoupled input, the connected consumers can be divided into buffered and non-buffered loads. Thus, the buffer time, which is dependent on the output current, is extended. If only the critical consumers are protected, the buffer time is markedly extended. In addition, the decoupled input of the connected consumers protects against errors in the internal network. 0,1 0 5 10 15 20 1 at 22,5 V 2 at 24 V 3 at 28,5 V Output current [A] 102035_03_en PHOENIX CONTACT GmbH & Co. KG 32823 Blomberg Germany 10 Phone: +49-(0) 5235-3-00 Fax: +49-(0) 5235-3-4 12 00 www.phoenixcontact.com www.phoenixcontact.com/salesnetwork