Can be configured in the PNOZmulti Configurator Semiconductor outputs: or 4 safety outputs in accordance with EN 954-1, Cat. 3

Similar documents
20 inputs for connecting, for example:

Products. Base units PNOZmulti Base units PNOZmulti PNOZ m0p (ETH) PNOZ m1p (ETH) PNOZ m2p (ETH) PNOZ m3p (ETH) 2.

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Two-hand control unit

Contact expander modules

E-STOP relays, safety gate monitors

Two-hand control unit

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Two-hand control unit

E-STOP relay, safety gate monitor

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Safe monitoring relays

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Safe timer relay/contact expansion modules

Faults on the system Proximity switch connection technology:

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

Safe timer relay/contact expansion modules

E-STOP relay, safety gate monitor

E-STOP relay, safety gate monitor

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Safe monitoring relays

E-STOP relays, safety gate monitors

PNOZ ml1p. PNOZmulti Modular Safety System. Operating Manual No EN-05

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Safety relays PNOZsigma

E-STOP relays, safety gate monitors

PNOZ m EF 8DI4DO. Configurable Control System PNOZmulti. Operating Manual EN 02

PNOZ s1. Safety relays. Operating Manual EN-07

E-STOP relays, safety gate monitors

Electronic monitoring relays PMDsrange

PNOZ s9. Safety relays. Operating Manual EN-08

PNOZ s2. Safety relays. Operating Manual EN-07

Speed Monitor. Up to PL e of EN ISO PNOZ s30. Unit features

Datasheet - SRB 402EM-24V

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

PNOZ m EF PDP Link. Configurable Control System PNOZmulti. Operating Manual EN 02

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

PNOZ m EF Multi Link. } Configurable control systems PNOZmulti 2. Operating Manual EN-04

Safety Technique. SAFEMASTER C Multifunction Safety Module BH 5910

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Datasheet - SRB 301LC/B-24V

MINI-PS AC/10-15DC/8

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

XPSMCMDO Digital output pairs expansion modules with screw term

Datasheet SRB301ST 24V (V.2)

Safety module - PSR-SCP- 24DC/TS/S

PSEN 4.2a/b/p/M12. PSEN sensor technology. Operating Manual EN-02

PNOZ mc6p, PNOZ mc6.1p

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

XPSMCMDI Input expansion module with screw term

PHOENIX CONTACT Features

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

XPSMCMMX inputs 2 output pairs expansion module with screw term

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

AS-i 3.0 Sercos Gateways with integrated Safety Monitor

Operating Manual PNOZ mm0p. Operating Manual PNOZ mm0p. PNOZ mm0p. Configurable Control System PNOZmulti. Operating Manual No.

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

MSR178DP. Description. Features. Specifications

PNOZ m B0. Configurable Control System PNOZmulti. Operating Manual EN 04

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

PSR DC/ESP4/2X1/1X2

PNOZ mc4p. } Configurable safety systems PNOZmulti. Operating Manual EN-05

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

Datasheet - AZM 200SK-T-1P2PW

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

PNOZ ms1p. Configurable Control System PNOZmulti. Operating Manual EN 11

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

Safety relay emergency stop/protective door, 230VAC, 3 enabling paths

Operating Manual PNOZ mc3p. Operating Manual PNOZ mc3p. PNOZ mc3p. Configurable Control System PNOZmulti. Operating Manual No.

PHOENIX CONTACT - 07/2006

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

Transcription:

Products Expansion Gertebild mo1p modules PNOZmulti Verwendung/Bildunterschrift_multi_Modul Expansion module for connection to a base unit from the configurable control system PNOZmulti Approvals Unit features Gertemerkmale Can be configured in the PNOZmulti Configurator Semiconductor outputs: 2 safety outputs in accordance with EN 954-1, Cat. 4 or 4 safety outputs in accordance with EN 954-1, Cat. 3 Status indicators Plug-in connection terminals (either cage clamp terminal or screw terminal) Max. 6 units can be connected to the base unit Geraetemerkmal_Coated Version Coated version: Increased environmental requirements Unit description Bestimmung/Gertebeschreibung_multi_Zusatz_Modul The expansion module may only be connected to a base unit from the configurable control system PNOZmulti (please refer to the document "PNOZmulti System Expansion" for details of the base units that can be connected) Bestimmung/Gertebeschreibung_multi_System The configurable control system PNOZmulti is used for the safety-related interruption of safety circuits and is designed for use in: E-STOP equipment Safety circuits in accordance with VDE 0113 Part 1 and EN 60204-1 The coated version of the product is suitable for use where there are increased environmental requirements (see Technical Details). System requirements Systemvoraussetzungen - Verweis auf Produktänderungen Please refer to the "Product Modifications" document in the "Version overview" section for details of which versions of the base unit and PNOZmulti Configurator can be used for this product. Safety features Sicherheitseigenschaften_multi_allgemein The relay conforms to the following safety criteria: The circuit is redundant with built-in self-monitoring. The safety function remains effective in the case of a component failure. Sicherheitseigenschaften_Halbleiter The safety outputs are tested periodically using a disconnection test. Zulassungen Bestimmung/Gerätebeschreibung_Zusatz_Coated Version Block diagram Blockschaltbild Interface to previous module Interface to next module 24 V 0 V O0 O1 O2 O3 24 V 0 V -21

Function description Funktionen_multi_Halbleiterausg The expansion module provides additional semiconductor outputs. The function of the outputs on the safety system depends on the safety circuit created using the PNOZmulti Configurator. A chip card is used to download the safety circuit to the base unit. The base unit has 2 microcontrollers that monitor each other. They evaluate the input circuits on the base unit and expansion modules and switch the outputs on the base unit and expansion modules accordingly. The online help on the PNOZmulti Configurator contains descriptions of the operating modes and all the functions of the PNOZmulti safety system, plus connection examples. Wiring Verdrahtung The wiring is defined in the circuit diagram in the Configurator. Please note: Information given in the "Technical details" must be followed. Outputs O0 to O3 are semiconductor outputs. Use copper wire that can withstand 75 C. -22

Preparing for operation Betriebsbereitschaft herstellen Supply voltage Supply voltage AC DC 24 V + 24 V DC 0 V 0 V Semiconductor outputs Redundant output O0 (O2) K1 Single output O1 (O3) K2 O0 (O2) K1 K2 O1 ( O3) K3 K4 Feedback loop Feedback loop Redundant output Contacts from external contactors O0 (O2, O4) O1 (O3, O5) K2 K1 I0 L+ -23

Terminal configuration Klemenbelegung Dimensions Abmesungen 121 (4.76") 94 (3.70") 22,5 (0.88") -24

Maximum capacitive load C (μf) with load current I (ma) at the semiconductor outputs C (µf) 6 4 2 0 0 10 50 100 200 400 600 800 1000 1200 1400 1600 1800 2000 I (ma) Notice ][Wichtig_PDB This data sheet is only intended for use during configuration. Please refer to the operating manual for installation and operation. ][Technische Daten_multi_Basis Technical details Electrical data Module's supply voltage via base unit 5 V DC Voltage tolerance -2 %/+2 % Power consumption 2.5 W Status display LED Times Switch-on delay 5.00 s Supply interruption before de-energisation 20 ms Semiconductor outputs Number 4 Switching capability voltage 24 V current 2 A power 48 W Derating of coated version at an ambient temperature > 50 C Voltage 24 V No. 773505 Current 1 A No. 773505 Power 24 W No. 773505 Max. capacitive load 1 µf External supply voltage 24.0 V Voltage tolerance -15 %/+20 % Max. duration of off time during self test 300 µs Galvanic isolation yes Short circuit-proof yes Switch-off delay 30 ms Residual current at "0" 0.5 ma Signal level at "1" UB - 0.5 V DC at 2 A -25

Environmental data Ambient temperature -25-60 C No. 773505 0-60 C No. 773500 Storage temperature -25-70 C Climatic suitability in accordance with EN 60068-2-30, 93 % r. h. at 40 C EN 60068-2-78 Condensation temporary No. 773505 not permitted No. 773500 EMC EN 61131-2 Vibration to EN 60068-2-6 Frequency 10-150 Hz No. 773500 5-500 Hz No. 773505 Max. acceleration 1g Airgap creepage in accordance with EN 61131-2 Overvoltage category III Pollution degree 2 Rated insulation voltage 30 V Corrosive gas check SO2: concentration 10 ppm, duration 10 days, passive DIN V 40046-36 No. 773505 H2S: concentration 1 ppm, duration 10 days, passive DIN V 40046-37 No. 773505 Shock stress EN 60068-2-27 Technische Daten_Satz No. 15g 11 ms Mechanical data Protection type Mounting (e.g. cabinet) IP54 Housing IP20 Terminals IP20 DIN rail Top hat rail 35 x 7.5 EN 50022 Recess width 27 mm Housing material Housing PPO UL 94 V0 Front ABS UL 94 V0 Cross section of external conductors with screw terminals Power supply, inputs, auxiliary output, semiconductor outputs, test pulse outputs, cascading outputs: 1 core flexible 0.50-1.50 mm², 22-14 AWG 2 core, same cross section, flexible: with crimp connectors, without insulating sleeve 0.50-0.75 mm², 22-20 AWG without crimp connectors or with TWIN crimp connectors 0.50-0.75 mm², 22-20 AWG Torque setting with screw terminals 0.25 Nm Cross section of external conductors with spring-loaded terminals: 0.50-1.50 mm², 26-14 AWG Flexible with/without crimp connectors Spring-loaded terminals: Terminal points per connection 1 Stripping length 9 mm Dimensions Height 94.0 mm Width 22.5 mm Depth 121.0 mm Weight 154 g No. 773500 156 g No. 773505 No. stands for order number. Si-Kennzahlen_alle -26

Safety characteristic data Unit Operating mode EN ISO 13849-1: 2006 PL EN 954-1 Category EN IEC 62061 SIL CL PFH [1/h] EN ISO 13849-1: 2006 T M [year] SC outputs single-channel PL d (Cat. 2) Cat. 3 SIL CL 2 7.00E-09 20 SC outputs dual-channel PL e (Cat. 4) Cat. 4 SIL CL 3 8.60E-10 20 Si_Kennzahlen_Erläuterung_1 All the units used within a safety function must be considered when calculating the safety characteristic data. Technische Daten_Satz Normen The standards current on 2008-03 apply. Bestelldaten Order reference Product type Features Order no. Expansion module, 2 or 4 semiconductor outputs, safe 773 500 coated version Expansion module, 2 or 4 semiconductor outputs, safe, coated version 773 505 Bestelldaten Zubehör PNOZ mi1/2p-ml1/2p-mc0p-mo1/3p Order reference: Accessories Product type Features Order no. Set spring terminals 1 set of spring-loaded terminals 783 400 Set screw terminals 1 set of screw terminals 793 400 Bestelldaten Zubehör Abschlussstecker/Steckbrücke mit coated Order reference: Connectors Product type Features Order no. PNOZmulti bus terminator Terminator 779 110 PNOZmulti bus terminator coated Terminator, coated version 779 112 KOP-XE Jumper 774 639 KOP-XE coated Jumper, coated version 774 640-27