Acquisition and Evaluation, 2825A... TEL: Measuring Instrument Control and Configuration via Communication Interfaces RS-232C 501

Similar documents
DynoWare. Electronics & Software. Software for Data Acquisition and Evaluation. Type 2825A...

DynoWare. Electronics & Software. Software for Data Acquisition and Evaluation. Type 2825A...

DAQ-System for DynoWare

System Requirements Operating System Windows XP, Windows Vista >512 MB RAM CPU speed >2,5 GHz CD-ROM drive USB or parallel interface Important

DataFlow. DataFlow. Electronics & Software. Quality Monitoring System. DataFlow Statistics. Type 2805A...

Electronic SUNSTAR & 传感与控制 Software TEL: FAX: KiBox To Go Measurement and Ev

Instruction Manual DynoWare Type 2825A

Application The standard SmartCrash segment is used vertically in the automotive industry and in vehicle crash test centers, and horizontally in tower

SCP for Plastics Processing

Pressure Measurement, Application The Multi Sensor Set is designed for industrial use in multicavity molds. The multi-channel connectors Type

advanced, Technical Data General Power supply VDC 24 ±10 % Power consumption W <20 Operating temperature range C Storage temperature r

NextView 4 Software for Data Acquisition and Analysis

Quick Start Guide. Cole-Parmer USB-based Data Acquisition Software

Technical Data Press Force Sensor Type 9323AA 9323A 9333A 9343A 9363A 9383A 9393A Measuring range F z, max. kn

Overview DT Measure Foundry is a drag-anddrop test and measurement application builder designed to give you top performance

DT Measure Foundry TM is a powerful software package designed for test and measurement,

KiBox To Go. Electronics & Software. Measurement and Evaluation System for Combustion Analysis on Test Benches and in Vehicles

Type 5863A2 Process values and measuring curves can be sent in cycles to a data server in the network. The software service required for the d

CoMo Logic. Electronics & Software. Single-Channel y(t) ControlMonitor. Type 5875A...

Data acquisition hardware

Software Package Installation Instructions

TROVIS-VIEW software TROVIS 6661

EXPERIMETRIA LTD. S.P.E.L. Advanced Software Family. Brochure. Isosys Kymograph.

40 to 150 MHz digital and mixed oscilloscopes

TROVIS-VIEW 4 Software TROVIS Operating Instructions EB 6661 EN. Electronics from SAMSON

Quick Start Guide Agilent Technologies 14565A Device Characterization Software for Windows 98, Windows NT 4.0, Windows 2000 and Windows XP

A variety of ECONseries modules provide economical yet flexible solutions. Waveform Generation

MC.72xx - 32 bit Digital Pattern Generator with programmable logic levels

MEphisto Scope 1 A D. Prozessor-Steuerung. Interner Daten-/Steuer-Bus. Digital I/O-Teil

maxymos BL Electronics & Software XY Monitor for Good/Bad Evaluation of Curves Type 5867B...

...the precision signal conditioning company. Combustion Analyzer Series. Automotive Research & Development.

DT9828. USB Powered Thermocouple Measurement Module. Key Features: Analog Input Channels

HCC-F Software. Honigmann Computer Control - Precision Friction Meter

catman Data Acquisition and Analysis software Special features Data sheet Generic Modules Application Modules

A 40-pin connector provides access to 24 DIO connections.

4-component Dynamometer (RCD)

Hand-held thermometer Model CTH6200

MC.72xx - 32 bit Digital Pattern Generator with programmable logic levels

easy-to-use flexible powerful Measurement and controlling with Windows Flexible configuration of user interfaces and displays

VIBBOX. 32, 48, or 64-Channel Sound & Vibration Solution Expansion to 256 Channels. Key Feature of Each VIBbox: Table 1. Key Features of VIBbox Models

Hand-held thermometer Model CTH6200

Features. High-precision Analog input board (Low Profile size) for PCI Express AI-1616L-LPE AI-1616L-LPE 1. Ver.1.01

Hand-Held Thermometer Model CTH 6200

BTH-1208LS Wireless Multifunction DAQ Device

DT9828. Low-Cost, Isolated, Thermocouple Measurement Module. Overview. Key Features. Supported Operating Systems

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

ArbExpress AXW100 Waveform Creation and Editing Tool for Tektronix AWG/AFG Installation Manual

CVI SPECTRAL PRODUCTS. 111 Highland Drive Putnam CT, (860) SM32Pro

A variety of ECONseries modules provide economical yet flexible solutions

Flexible configuration of user interfaces and displays. Easy generation of protocol and presentation sheets

Measurement Equipment for Future Transient Recorder TransCom-CompactX MF Instruments GmbH

Features Summary. Input Ranges

Personal Daqs USB Data Acquisition Modules Models /55 & /56

DT3000 Series. DT3000 Series. Key Features. at full rated throughput.

Operation Manual for USB Autoscope Lite. Contents. USB Autoscope Lite Operation Manual

DT3016. High-Speed, Multifunction PCI Data Acquisition Board. Overview. Key Features. Supported Operating Systems

DIAGNOSTICS PN# / / FSP

ArbExpressr AXW100 Waveform Creation and Editing Tool for Tektronix AWG/AFG Version

Precision hand-held pressure indicator Model CPH6400

DM3100 Solutions. Application-specific Portable Data Capture Systems built on the DM3100 Data Platform. PC-based Data Logger. Digital Oscilloscope

Figure 3.174: Illustration of the code of the event f USB that plots an USB camera frame if the typed frame is under the acceptable limits (case 0)

DT9800 Series. USB Function Module for Data Acquisition

MODEL.6715 DATA ACQUISITION SOFTWARE INSTRUCTION MANUAL

CompuScope 1602 product introduction

TROVIS-VIEW 4 Software TROVIS Operating Instructions EB 6661 EN. Electronics from SAMSON

±500 V Isolation Protects Your Data. Sample Rate. 16 bits ±1.25 V, ±2.5 V, ±5 V, ±10 V 100 ks/s 16 2

BE/EE189 Design and Construction of Biodevices Lecture 5. BE/EE189 Design and Construction of Biodevices - Caltech

Welcome Subject to change without prior notice / Siemens AG, 2009

Analog Input Sample Rate

AD16-16(PCI)EV. Features. High-Resolution Analog Input Board for PCI AD16-16(PCI)EV 1. Ver.1.01

General Specifications

AD12-16(PCI)EV. Features. Analog Input Board for PCI AD12-16(PCI)EV 1. Ver.1.01

Data Acquisition Laboratory

Keysight Technologies VEE Pro 9.32

VIBbox 64-Channel Sound & Vibration Solution

Orbit USB Interface Module. User Manual

Power & Harmonics Analyzer

TABLE OF CONTENTS PRODUCT DESCRIPTION VISUALIZATION OPTIONS MEASUREMENT OPTIONS SINGLE MEASUREMENT / TIME SERIES BEAM STABILITY POINTING STABILITY

DMT PERFORMING UNDER PRESSURE DMT. With USB adapter and software. Applications. Special features. Description 1/7

AIO UE3-PE. Features. 1MSPS 12-bit Analog I/O Board for PCI Express AIO UE3-PE 1. Ver.1.01

DT MS/s High-Speed, Isolated Simultaneous USB Data Acquisition Module. Overview. Key Features. Bandwidth of the DT9862

Practical and Compact!

ALMEMO 202 ALMEMO professional measuring instrument, latest V7 generation with data logger function. ALMEMO V7 Measuring Instrument

Version: 16/12/2013. GSV-2MSD-DI Data Logger Instruction manual

Peregrine Technology CO.,LTD. DSO Oscilloscope. User Menu. V1.1 Date: 2014/07/11

LabVIEW Core 1. What You Need To Get Started. File Locations. The course installer places the course files in the following location: ni.

VM600 Configuration Software. Configuration Software for VM600 Series Machinery Protection Systems (MPS) FEATURES

Advanced NI-DAQmx Programming Techniques with LabVIEW

AN-619 APPLICATION NOTE

1. Learn about LabView software and its different components

ECONseries Low Cost USB DAQ

Operating Manual for ThermoView PC Software

2.0 GHz Pentium M 760 and 1.5 GHz Celeron M 370 Embedded Controllers for PXI

Measure Foundry. Open. Powerful. Application Builder for Test & Measurement Systems. Measure Foundry Instruments and Advanced Instruments versions:

AN-730 APPLICATION NOTE One Technology Way P.O. Box 9106 Norwood, MA Tel: 781/ Fax: 781/

KingView Quick Start Manual How to create a new project

6224 Ethernet-Based Strain Measurement Module

USB-500 Series Getting Started Contents

Acquiring Data from Sensors and Instruments Using MATLAB

Transcription:

Electronics SUNSTAR & 传感与控制 Software http://www.sensor-ic.com/ TEL:0755-83376549 E-MAIL: DynoWare Software for Data Acquisition and Evaluation 2825A... Kistler DynoWare is a universal and easy to use software, which is particularly suitable for force measurements with dynamometers or single and multi-component force sensors. Simple operation Configuration and control of Kistler measuring instruments via USB, RS-232C or IEEE-488 Useful signal evaluation and calculation functions Simultaneous recording of up to 28 measuring channels Realtime visualization of measured curves The software is ideal for the acquisition and evaluation of physical measurands Description For signal analysis, DynoWare offers the technician realtime visualization of the measured curves together with useful calculation and graphics functions. Apart from simple configuration of the most important measuring instruments, this software supports individual documentation of the measurement, along with storage of configuration data and measured data. The signal evaluation also enables compensation of undesirable signal drift due, for example, to undue influence of temperature. DynoWare supports several A/D cards (PCI/PCMCIA) as well as USB 2.0 of DAQ-System 5697A. Technical Data Data Acquisition Cards Supported 2855A4, PCIM-DAS 1602/16 PC bus: PCI Number of measuring channels: 8, analog, differential Resolution: 16 Bit Measuring range: ±1,25 V; ±2,5 V; ±5 V; ±10 V Sampling rate: 1 measuring channel active: 100 ks/s 8 measuring channels active: 12,5 ks/s Application DynoWare is the data acquisition software of choice for cutting force measurement. It supports both stationary and rotary measuring systems from Kistler. However, DynoWare can also be used for any reaction force measurements or crash measurements with Kistler multicomponent dynamometers. At the same time, the measured data from signal amplifiers of other manufacturers can also be measured and evaluated. 2855A5, PC-CARD-DAS 16/16 1) PC bus: PCMCIA, PC-CARD Number of measuring channels: 8, analog, differential Resolution: 16 Bit Measuring range: ±1,25 V; ±2,5 V; ±5 V; ±10 V Sampling rate: 1 measuring channel active: 100 ks/s 8 measuring channels active: 12,5 ks/s 5697A: USB DAQ-System Connection: UBS 2.0 Number of measuring channels: 28 2), analog, single-ended Resolution: 16 Bit Measuring range: ±0,1 V, ±0,2 V, ±0,5 V, ±1 V, ±2 V, ±5 V, ±10 V Sampling rate: 1 Channel active: 1 MS/s 8 Channels active: 125 ks/s 16 Channels active: 62,5 ks/s 1) 2) Not supported on Windows Vista and Windows 7. DynoWare 2825A as well as Update 2825E allow to control one charge amplifier only. DAQ-System 5697 is capable to acquire 28 channels maximum. Page 1/6

Acquisition and Evaluation, 2825A... TEL:0755-83376549 E-MAIL: Measuring Instrument Control and Configuration via Communication Interfaces RS-232C 5011Bx2, 5015A..., 5017..., 5018A..., 5019..., 5070A, 5080A..., 5223..., 5237..., IEEE-488 5011Bx1, 5015Ax1xx, 5070Axxxx1 USB 2.0 5018A..., 5080A... Triggering Analog, digital and by Keyboard Digital Signal Evaluation Within a measuring window Averaging Minimum and maximum values Integral Determining the signal frequency Signal smoothing/filtering Moving mean value Moving median value Filters: High pass, low pass, band pass and band stop Compensation of signal drift Tools Voltmeter function Oscilloscope function Documentation of the Measurement Each measurement can be individually documented. Storage of measurement and configuration data with or without remarks Export of measured data and ASCII format (.txt) or (.csv) for Excel, DIAdem, LabVIEW, Matlab, etc. Printer Printing of test records and configuration data is supported by Windows Example of a Test Record Graphics Functions Measured data represented on one or more graphs Display as y(t) and y(x) graphs Display of numeric values Cursor function Zoom function Calculation Functions Multi-component force-moment calculation Calculation of radial and tangential forces with rotating cutting force dynamometer 9123 /24 Mathematical functions Page 2/6

Acquisition and Evaluation, 2825A... TEL:0755-83376549 E-MAIL: Cable Concept for DynoWare 2825A with A/D Cards 2855A4 and 2855A5 Signal Conditioner Measuring Signal Connecting Cable A/D Acquisition Card 5070 5080... 1) 1500B15 D-Sub pos. 15 pole 1500B15 D-Sub neg. 37 pole Digital L Trigger H Digital L Output H 2 m 2855A4 PCIM-DAS1602/16 (PCI-Bus) 5011 5015 5018... other products 1500A67 8x BNC pos. 1500A67 D-Sub neg. 37 pole 2 m D-Sub pos. 37 pole Only for signals from the 6-component summing calculator 5017Bxxx1 5070Ax2xxx 5080Axx8xxxx 2) 1500A7 D-Sub pos. 15 pole 1500B15 D-Sub neg. 37 pole 1500B69 D-Sub pos. 37 pole MERITEC 50 pole 2 m Digital Trigger Digital Output L H L H 1 m 1) Cable 1500B15 is used when output signals Fx1+2, Fx3+4, Fy1+4, Fy2+3, Fz1, Fz2, Fz3, Fz4 have to be acquired. 2) Cable 1500A7 is used when summed signals Fx, Fy, Fz, Mx, My, Mz have to be acquired. 3) Windows Vista/Windos 7 does not support PC card DAS 16/16 2855A5 3) PC-CARD-DAS16/16 (PC-CARD-Bus) 50 pole Page 3/6

Acquisition and Evaluation, 2825A... TEL:0755-83376549 E-MAIL: Cable Concept for DynoWare 2825A with DAQ-System Typ 5697A Signal Conditioner Measuring Signal Connecting Cable A/D Acquisition Card 5070 5080... 3) D-Sub pos. 15 pole 1700A111A2 D-Sub neg. 15 pole 5697A 5011 5015 5018... other products 8x BNC pos. 1700A113A2 D-Sub neg. 15 pole D-Sub pos. 15 pole 3) Cable 1700A111A2 can be used in addition with DAQ-System 5697A, regardless of summed or output signals being acquired. Page 4/6

Acquisition and Evaluation, 2825A... TEL:0755-83376549 E-MAIL: Interface Cables Signal Conditioner RS-232C Interface Cable (Null Modem) 5011Bx2 1475A3 D-Sub pos. 25 pole 1475A3 D-Sub neg. 9 pole 3 m 5015 5018... 5070 5080... D-Sub pos. 9 pole 1200A27 5 m D-Sub neg. 9 pole Typical Measuring Chain with DAQ-System 5697A1 Dynamometer Connecting cable, Charge Amplifier Connecting cable DAQ-System high resistant 9129AA 1677A5 5070A 1700A111A2 5697A1 1200A27 Notebook (customer) with DynoWare Page 5/6

Acquisition and Evaluation, 2825A... TEL:0755-83376549 E-MAIL: Requirements for the PC Operating System: Windows NT4.0 (SP4), 2000, XP, Vista, Windows 7 (32-bit/64-bit versions) Pentium PC 500 MHz or higher Hard disc: 100 MB free space for data storage and software installation Memory: at least 512 MB RAM Super VGA monitor, screen resolution set to at least 800x600 Vacant port (PCI or PC-CARD) for data acquisition board 2855A4/2855A5 USB 2.0 port for DAQ-System 5697A USB port for USB/RS-232C converter ( 2867) Parallel interface Centronics (LPT1) or USB for license key CD-ROM drive A color printer is recommended for creating hard copies of graphs Acrobat Reader for reading the PDF Instruction Manual Optional Accessories Data acquisition card 2855A4, PCIM-DAS 1602/16 Data acquisition card 2855A5, PC-CARD-DAS 16/16 DAQ system, USB 5697A... Connecting cable 1500B15 Connecting cable 1500A67 Connecting cable 1700A111A2 Connecting cable 1500B69 Connecting cable 1700A113A2 Interface cable 1200A27 Interface cable 1475A3 USB/RS-232C converter 2867 Ordering Key Scope of Delivery Including Accessories DynoWare Complete Version Runtime license key for parallel interface 2825A-02-1 DynoWare Complete Version 2825A-02-2 Runtime license key for USB interface (HASP) DynoWare Update Version DynoWare Demo Version DAQ-System for DynoWare Complete version HASP license key, 2825A USB 2.0 DAQ-box USB cable, length 1,8 m Universal AC/DC adapter 100... 240 V DAQ-System for DynoWare Update version, 2825E USB 2.0 DAQ-box USB cable, length 1,8 m Universal AC/DC adapter 100... 240 V 2825E-02-0 2825D-02-0 5697A1 5697A2 Windows is a registered trade mark of Microsoft Corporation. Adobe Reader is a registered trade mark of Adobe. Page 6/6