LogicStudio Training Guide

Similar documents
Training Kit for HP 1660/70 Series Logic Analyzers

Getting Started with LabVIEW Virtual Instruments

Quick Reference Guide WaveRunner Xi-A and MXi-A Oscilloscopes

2 Lab 2: LabVIEW and Control System Building Blocks

Student Quick Reference Guide

Peregrine Technology CO.,LTD. DSO Oscilloscope. User Menu. V1.1 Date: 2014/07/11

LogicStudio USB Logic Analyzer. Faster, Smarter Debug

Linear Control Systems LABORATORY

TBS2000 Oscilloscope Demo Guide 28 JULY 2016

Step 1. Overview. Goal. System Requirements - 1 x WaveAce passive probe. Setup

Help Volume Agilent Technologies. All rights reserved. Agilent E2485A Memory Expansion Interface

PCI-express data acquisition card DAQ0504M User Guide

ME 365 EXPERIMENT 3 INTRODUCTION TO LABVIEW

The iworx 214 and LabScribe V2.0 Tutorial. Overview

Exploring the Custom Analysis Interface for use with MATLAB on Tektronix Oscilloscopes

Front-Panel Menus and Controls

One possible window configuration preferences for debug cycles

Projecting The Digital Teacher s Edition in READ 180 Universal

Help Volume Hewlett Packard Company. All rights reserved. Toolsets: IA Format Utility

Quick Reference Guide WaveRunner 6 Zi Oscilloscopes

1. Getting Started with WaveForms

Navigator Software User s Manual. User Manual. Navigator Software. Monarch Instrument Rev 0.98 May Page 1 of 17

Parallel and Serial Bus Analysis Instructor s Guide

How to Save Google Maps Offline to a Mobile Phone

Dash HF Family High Speed Data Acquisition Recorder

Getting Started with DADiSP

EE 210 Lab Assignment #2: Intro to PSPICE

The uscope Getting started

Vision Pointer Tools

Lectora Audio Editor Information Center

Logic Analyzers by Link Instruments, Inc Logic Analyzers

Manual imso-204x. RevOrig_

BusFinder Series. LA3000 Series 2 in 1 Analyzer (Protocol + Logic) Manual

Small rectangles (and sometimes squares like this

Logic Analyzer Software Manual

Data Acquisition Software and Hardware Demonstration Guide

Part 1- Package contents: Part 2 Front Panel Layout. Part 3 Rear Panel Layout

Model JI-820 Incremental Encoder Emulator. User Manual

Step-by-Step Data Acquisition Part II Exercise 2: Generating an Analog Output Waveform

The LabVIEW Programming Environment and Basic Operations

OpenStax-CNX module: m Thermometer VI * National Instruments

R&S RTB2000 Oscilloscope Release Notes Firmware Version

Capstone Appendix. A guide to your lab computer software

Automatic Operation: This is the simplest and quickest way to capture a signal, knowing little about what you are measuring.

RLanglois ScanPro 3000 High Definition Microfilm Scanner Help Guide

Editing screen recordings with Camtasia Studio

PI3000. User Guide PASSENGER INFORMATION SYSTEM. rev 1.2

GFT6084 Quad 2 / 4GS Digitizer

This is a demonstration of how you can create a Microsoft Power Point presentation:

Quick Start Guide. Cole-Parmer USB-based Data Acquisition Software

Data Acquisition. Software and Hardware. Demonstration Guide. For: NetDAQ Logger for Windows Hydra Logger for Windows Trend Link for Fluke

I 2 C and SPI Protocol Triggering and Decode for Infiniium 9000 Series Oscilloscopes

Emote 1.0 Users Manual

ECB Digital - Way to Go! (7th Grade)

Part 1- Package contents: Part 2 DVR Camera and Power Connections

Manual. User Reference Guide. Analysis Application (EMG) Electromyography Analysis

JAZZ HARMONY User Manual

Adding the ILA Core to an Existing Design Lab

Introduction And Overview ANSYS, Inc. All rights reserved. 1 ANSYS, Inc. Proprietary

Student eedition About Student eedition

SwiftMaps Plugin User Guide

Lab Exercise 2: Data Acquisition with NI LabVIEW

Page 1 of 6. ME 3200 Mechatronics I Laboratory Lab 2: LabView Computer Systems. Introduction

MindWare Electromyography (EMG) Analysis User Reference Guide Version Copyright 2011 by MindWare Technologies LTD. All Rights Reserved.

Thyro-PX Software and Touch Display

Energy profiler and Network analyzer Training Lab manual for

Test Procedure for the NIS5101

PacTracs 2.0 Quick Start Guide

Computer Essentials Session 1 Lesson Plan

Manual imso-204 imso-204l

Mouse. Mouse Action Location. Image Location

Guide to User Interface 4.3

DDX-R Quick Start Guide

MiBio Reference Manual

Boise State University Digital Systems Laboratory

4-20 ma Current Data Logger

15. Check this point when you can t communicate

EASY INTERACTIVE WHITEBOARD

DLM2000 Series. Mixed Signal Oscilloscope. IM E 3rd Edition

GUARDIAN ALARM SYSTEMS

USB Instruments EasyScope II for PS40M10 "Swordfish" Help

Digital Storage Oscilloscope

MDA 8 preview SP3 What s New Functionality Overview

MDA V8.1 What s New Functionality Overview

Alibre Design Tutorial - Simple Revolve Translucent Glass Lamp Globe

1 Place the iworx/214 unit on the bench, close to the computer. 3 When the dialog box appears, select ahk214.iws and then click Load.

Introduction to XDisp Qt The New HKL-2000 and HKL-3000 Diffraction Image Display

Tutorial - Introduction to LabScribe and the IX-ELVIS

Tektronix DPO Demo 1 Board Instruction Manual

AiM User Guide. Race Studio 3 Track Manager. Release 1.00

Experiment 1: The LabScribe Tutorial

ECB Digital - Our World (5th Grade)

Exercise 0 - Open and Run a Virtual Instrument (Slide 12)

PC Based Logic Analyzer. Project Proposal

ECB Digital - Click 3 (4th Grade)

The Sales Rep s Guide to Using Drive

Web Accessibility Change Your Mouse Pointer Visibility Handbook

VERUS Navigation Guide

Using OPUS to Process Evolved Gas Data (8/12/15 edits highlighted)

Working with Spectrum Tabs, Plots, and Charts

Transcription:

LogicStudio Training Guide Summary This guide provides step by step instructions explaining how to use the LogicStudio software. LogicStudio can operate in demo mode providing full access to all controls and features when the hardware or demo board is not available. The LogicStudio software provides tools for viewing, measuring and analyzing digital, serial and analog waveforms. This guide will explain how to use the various tools built-in to LogicStudio such as cursors, waveform magnifier, history mode, serial trigger/decode and viewing analog waveforms from the WaveJet. The LogicStudio software can be downloaded at: http://www.lecroy.com/logicstudio/ LeCroy Corporation LogicStudio Training Guide page 1 of 7

1. Download and install the LogicStudio software appropriate for your computer from the LeCroy website including the instrument drivers. 2. Connect the LogicStudio module to the computer using the USB cable. 3. Launch the LogicStudio software. 4. Use the Help pull down menu in the LogicStudio software to access the User manual. Review the manual briefly to familiarize yourself with its content. 5. Use the file pulldown in the LogicStudio software to load the Default Setup. Figure 1: The Logic Studio default setup 6. Connect the LeCroy WS-100 demo board to an available USB port. If a new hardware found message appears press the Cancel button and continue. The WS-100 only uses the USB port for power. 7. Connect logic pod leads D0 through D4 to the output pins marked D0 through D4, respectively, on the WS-100 demo board using the micrograbber adaptors on the logic pod leads. LeCroy Corporation LogicStudio Training Guide page 2 of 7

(Note do not push the logic pod leads directly over the square pins on the WS-100 digital outputs as they are too large for the pod sockets and will spread them.) 8. Point and click the Setup: Signals button on the LogicStudio software. This will open the signal definitions pop up which allows you to define the type of signals and the signal name associated with each of the available inputs. Select D15 and remove it using the red X at the top of the pop up. Similarly remove the lines labeled D14 through D5. 9. Press the Auto trigger button in the upper left corner of the LogicStudio software display. The device should begin to acquire signals which will appear to be untriggered. 10. Press the Setup:Trigger button at the top of the LogicStudio software display. The trigger setup pop up will appear. Set up an edge trigger on the positive going edge of signal D4. Press OK, the signal display of Logic Studio will now appear stable. Figure 2: Logic Studio triggered on positive going edge of D4 LeCroy Corporation LogicStudio Training Guide page 3 of 7

11. Investigate the effect of changing the Setup:sampling frequency control. 12. Press the Magnifier button, shown in figure 3, it will be highlighted in blue. Move your cursor into the signal display. This tool provides a quick magnified view to see details in the signal display window. Click the Magnify button again to close the magnifier window. Figure 3: The Cursors, Rearview, Magnifier, and Zoom to Window icons 13. Press the cursor tool, it will be highlighted in blue. Click in the signal display, a vertical cursor will appear. Click on the cusor line and drag your mouse horizontally from the cursor, this will cause a dotted line with the time between the cursor line and the mouse position to be displayed. The time difference between the cursor line and the mouse cursor is shown above the line the reciprocal of the time difference (frequency) appears below the dotted line. 14. Click on the double arrow symbol on the right hand side of the cursor tool. A pop up box will allow you to define a total of 4 cursors. Exercise this feature so that you are familiar with cusor operations. Measure the frequency of signal D0. When done turn off all the cursors. 15. Press the Single button. The Logic Studio with take a single sweep and then stop, indicated by the Stop button being highlighted in blue. The RearView button should also be highlighted in blue. Press the double arrow on the RearView button. A pop up slide control will appear. By moving the slider it allows you to display the history of data acquisitions. Close the slider and return to Normal trigger. 16. Select signal D4 in the signals control panel, press the red X to remove D4. Do the same for D3-D1. 17. Click on the signal D0 in the signals control panel. You should see a signal definition box at the bottom of the LogicStudio software display. Change the signal type to Digital Bus, Radix Hex, Name: Bus, and LeCroy Corporation LogicStudio Training Guide page 4 of 7

change the color to orange. Check the Data boxes 0-4. 18. Press the Expand signal button on the Bus label in the signal control panel. You should see the bus view of the signal along with the five signals making up the bus. Use the magnifier to expand the displaly of the bus so you can see the bus values in hex. Use the zoom control to expand the signal display so the bus values are visible without the magnifier. Figure 4: The bus view setup 19. Remove the data bus from the signals control panel. Press the + sign and add a signal. Define it as I2C decode, RADIX:ASCII, Name I2C, Data assigned to 15, Clock assigned to 14. Connect the D15 logic pod lead to the CH1 test point on the WS-100 demo board. Similarly, connect the D14 line to the CH2 test point on the WS100. Push the selection button on the WS-100 until the LED marker S2 is flashing. This will output signals from the WS-100. 20. Setup the trigger on the LogicStudio to trigger on the positive edge of the clock signal. 21. Use the zoom control to expand the I2C signal until the decoded data is visible. LeCroy Corporation LogicStudio Training Guide page 5 of 7

Figure 5: The I2C decode display with the data table pop up 22. Press the single trigger button, than the open data table button on the I2C signal label. The data table will be shown as a pop up. The data table summarizes the data content seen on the I2C bus. 23. Connect the LogicStudio leads D0 through D4 to the respective digital output pin on the WS-100 using micrograbbers. Trigger the Logic Studio on the positive going edge of D4. 24. Connect the rear panel USB port of a WaveJet oscilloscope to the computers USB port. Connect a coaxial cable from the Trig Out connector on the LogicStudio module to the EXT input of the WaveJet oscilloscope. Turn on the oscilloscope and use the utilities menu to set it for remote control via USB. Set the trigger source to EXT, positive slope with a trigger level of 500 mv. 25. Use the Setup : Signals button to setup up digital lines for D0 D4. Add another signal and select Type: Analog Channel, Name : Chanel 1 and associate it with channel 1 of the oscilloscope. 26. Use the Devices pull down menu to activate the Scope Device. LeCroy Corporation LogicStudio Training Guide page 6 of 7

27. You should now observe both the digital lines as well as the analog signal from channel 1 of the oscilloscope. Figure 6: WaveJet oscilloscope waveform setup LeCroy Corporation LogicStudio Training Guide page 7 of 7