////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards)

Similar documents
////// SUBSTATIONS. Control command and local Scada

DC Substations / Supply Program

Traction Power Systems / Program

////// SUBSTATIONS. Voltage Limiting Device. VGuard

////// SUBSTATIONS SEPCOS. Control and protection relay

////// SUBSTATIONS SCMS. Stray Current Monitoring System

High-Speed DC Circuit-Breakers rolling stock Type UR26, UR36 & UR40

Innovation on Medium Voltage Switchgear

Alberto Carini, LPLS Italy, June 2013 MNS is The Intelligent MCC. ABB Group June 21, 2013 Slide 1

MNS Platform, low voltage systems Rear Access Power Motor Control Center. Alberto Carini, Global Product Manager

Air-insulated medium-voltage secondary distribution switchgear

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

High Safety low voltage switchgears For maximum requirements far beyond all standards.

KMP A3. Air Insulated Medium Voltage Switchgear Powerful. Safe. Highly Available

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

Products Portfolio. Pole mounted Vacuum Recloser

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

Quasar Series Technical Features

Lightning and Surge Arresters

Adaptors Busplug Low Voltage Switchboard Equipment

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Specification Voltage Limiting Device

Disconnect Switches. Safe Switching and Disconnecting

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

SENTRON 3VL Molded Case Circuit Breakers

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

VIP 40/45 VIP 400/410

GHA. Gas-Insulated Circuit-Breaker Switchgear Unit up to 40.5 kv. Gas-Insulated Switchgear. Customer Benefits

Air Circuit Breakers. 1/2 Introduction

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

Jtec 10kA Miniature Circuit Breaker

Feeder/ Motor Protection Relay VAMP 40

Remotely Operable 1500V DC Disconnector & Short-Circuit Switch Assembly

power pazifik MV Switchgear Secondary Distribution Networks Fully Gas-Insulated Modular and Compact (RMU) System Up to 36 kv

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

Relays for Various Protection Applications / 7SV600

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

3RV1 Circuit-Breakers

Supplementary Circuit Protectors Type GSB63

TECHNICAL SPECIFICATION FOR A 1500V DC SWITCHGEAR ASSEMBLY

MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A

Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

SACE Emax 2 Specification guide

Series 230 Automatic Transfer Switch

MESP TECHNICAL SPECIFICATION FOR 22 kv METAL ENCLOSED SWITCHGEAR

Communication Gateway COM 610. Product Guide

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A

SIPROTEC 7SV600 Numerical Circuit-Breaker Failure Protection Relay

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

Power Transmission Division Link between power generation and distribution

Package Substation. The efficient solution for your electrical distribution network

PROTECTION RELAYS: INNOVATIONS FOR THE BENEFIT OF THE USER

LV power circuit breaker and switch-disconnectors. Masterpact NW Direct current 1000 to 4000 A. Catalogue

Sivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip

Protection relays.

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

For Transmission, Distribution and Machinery protection.

ASCO SERIES 230 Automatic Transfer Switch

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

Medium Voltage Metal-Enclosed Power Capacitor Banks

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

SIRCO Load break switches for power distribution from 125 to 5000 A

100% electricity. Automatic transfer switch controllers ATL series

ENhanced TEChnology. Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1

MEDIUM VOLTAGE PRODUCTS. UniSec Air-insulated medium voltage secondary distribution switchgear Informed choice for safety

SWITCHGEAR MODELS CEP 14 / 15

EFASOLAR PVStation Solutions

Arc protection relay. Features Three-phase overcurrent function. Application

Generator Protection Unit, GPU Hydro Multi-line A SW version 2.4X.X

Catalog. Arc Guard System TM TVOC-2

Reliable Switchgear from One Proven Supplier

Ground Breaking MV Switchgear

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

US Catalog July 2016 SMISSLINE TP

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

Add-on Residual Current Protection PBSM MW

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

Medium Voltage Distribution Catalogue GenieEvo range. Air Insulated MV Switchgear kv

Feeder Protection Relay REF 610. Product Guide

Non-conventional instrument transformers Advanced GIS substations with IEC LE process bus

Switch Disconnectors, Main and EMERGENCY-STOP Switches

11 kv Indoor Switchgear - SCADA Controlled

Innovation for MV distribution

RER 123 Bus Connection Module. Technical Description

Medium Voltage Metal-Enclosed Harmonic Filter Systems

Series 2400 Paralleling Switchgear

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

GE Energy Connections Grid Solutions MMLZ. Technical Data Sheet Auxiliary Modules. Publication reference: MMLZ/EN TDS/B

PROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

ATV340D75N4E variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet

MNS ACS880 Switchgear mounted industrial drives

GPM500 Generator Protection Module

Benefits, offering and references

G - Base. Relays THREE PHASE + NEUTRAL CURRENT PROTECTION RELAY

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

Transcription:

////// SUBSTATIONS DC Switchgear Range Type MBS (IEEE/ANSI standards)

GENERAL INFORMATION With a complete range of equipment and a leading expertise in DC traction power substations, Sécheron SA is a world leader and major partner for electrification of DC traction networks. Covering all activities from calculation, network design and engineering, up to the production of the DC Systems, Sécheron SA can offer customers and partners tailor made solutions based on a modular concept and standard products. Our equipment is developed on world leading technology and proven worldwide design and acceptance. In-house technology covers all key devices applied in the DC Systems (Rectifiers, DC HSCB, Disconnect Switches, Protection Relays, Measuring Amplifiers, etc.). U [VDC] 1800 900 MBS 20 UR26 MBS 20 UR46 MBS 20 UR60 MBS 24 UR80 0 2000 4000 6000 8000 I [A] MAIN BENEFITS D Limited maintenance with easy access to all parts. D DD Very compact with minimum depth. DD Possibility to install cubicles directly against a wall. DD Front access to all equipment. MAIN BENEFITS DD Fully type tested according to IEEE Std. C37.20.1-2015 and C37.14-2015. 2 DC Switchgear Range / Type MBS (IEEE/ANSI standards)

HSCB DC SWITCHGEAR: DESCRIPTION DC traction networks require safe power distribution and reliable control systems. The MBS breaker panel is based on Sécheron traction DC protection experience and proven technology components are applied for all major functions in this cubicle. The DC switchgear serves as the control and protection equipment for the DC power distribution. The DC breaker panel type MBS is a modular concept cubicle which integrates different functions and equipment in three compartments: Rear high-voltage busbar compartment Protection and control system High-speed circuit breaker trolley /// REAR HIGH-VOLTAGE BUSBAR COMPARTMENT The high-voltage compartment is at the rear of the cubicle. It contains the main busbar, cable connections, voltage and current measuring and, where applicable, disconnector switches. MBS Feeder Panel /// PROTECTION AND CONTROL SYSTEM The protection and control system is located at the front of the cubicle. This low-voltage compartment contains low-voltage components and ensures the protection through the SEPCOS, protection and control relay. /// HIGH-SPEED CIRCUIT BREAKER TROLLEY The high-speed circuit breaker (Sécheron UR series) is mounted on a removable four-wheeled trolley which can be easily withdrawn from the cubicle. The trolley also contains the load measurement system. The HSCB is connected to the auxiliary circuits thanks to an unpluggable multiple connector and the breaker is connected to the high-voltage busbars by power finger connectors. All trolleys are exchangeable by one of the same type and are easy to manoeuvre. The withdrawable high-speed circuit breaker trolley has four positions: Service position Test position Disconnected position Removed position When the trolley is in service position, the front high-voltage door is locked and it is not possible to access the trolley. When high-voltage is applied to the breaker, it must be open before the trolley can be moved from service to test position. The trolley is moved from one position to another either manually by an external handle or electrically via the SEPCOS touch screen display. In this way, user s security is ensured. Trolleys can be encoded to ensure that they cannot be exchanged for a trolley of another type. Active equipment is located on the trolley. The motorized trolley is an available option that allows the trolley to be disconnected in remote mode, thus replacing the line isolating disconnecting switch. MBS Feeder Trolley Service and test positions DC Switchgear Range / Type MBS (IEEE/ANSI standards) 3

HSCB DC SWITCHGEAR: CHARACTERISTICS Symbol CUBICLE TYPE MBS 24 Unit MBS 20 Rated service current I Ne [A] 2000 4000 6000 8000 Rated voltage U Ne [VDC] 800/1600 Circuit breaker type - - UR26 UR46 UR60 UR80 Power frequency withstand voltage - Active part to earth (50 Hz, 1 min) - [kv] 5.5/9.2 Main busbar I e [ka] Up to 11 Busbar rating - Connection - [A] 2000 4000 6000 8000 Rated short-circuit current 800 VDC 1600 VDC I Nss /Î Nss [ka] 120/200 60/100 Protection degree - - IP20 or IP42 Ambient temperature range T [ C] -5 to +40 Typical weight - [kg] 500 550 650 700 Dimensions (W x D x H) - [mm] [in] 500 or 600 x 1600 x 2400 19.75 or 23.5 x 63 x 94.5 For further characteristics: Please refer to the data sheet for the individual circuit-breaker type. Characteristics according to IEEE Std. C.37.16-2009. Designed according to standard specifications C37.20.1-2015 and C37.14-2015. HSCB DC SWITCHGEAR: COMPOSITION Key components of the switchgear are designed and manufactured by Sécheron and are fully compatible. SEPCOS Control and protection relay VM10 / VM12 Voltage measuring amplifier SEPCOS Display Touch screen interface MIU10 Current measuring amplifier UR26 to UR80 High-Speed Circuit Breaker Optional: SWS Disconnector 4 DC Switchgear Range / Type MBS (IEEE/ANSI standards)

HSCB DC SWITCHGEAR: APPLICATIONS Line feeder Line feeder with isolating switch Line feeder with earthing switch Rectifier breaker Line feeder with by-pass Line feeder with by-pass and isolating switch Installation of lightning arrester for outgoing feeder is available upon request. HSCB DC SWITCHGEAR: MAIN DIMENSIONS 19.75 or 23.5 63 42.25 20.75 86.5 8 56.25 30.25 Low-voltage compartment (control and protection circuits) DC circuit breaker HSCB connector (harting) Withdrawable breaker trolley HSCB control High-voltage compartment VM10 / VM12 Voltage measuring isolator MIU10 Current measuring isolator Output cables Shunt (current) Main plugs (power circuit) Main busbar Optional: Load measurement system Optional: By-pass busbar Optional: Motor Optional: Disconnecting switch DC Switchgear Range / Type MBS (IEEE/ANSI standards) 5

DISCONNECTING DC SWITCHGEAR Disconnector cubicles are applied for incoming DS, negative DS or coupling DS. The system contains two compartments: High-voltage compartment Low-voltage compartment Each compartment has a separate front door and can be mounted against the wall. Cable connection is possible from the bottom or top. Disconnectors are rated 2000 A, 4000 A, 6300 A and 8000 A. /// INCOMING DS CUBICLE Incoming DS cubicles isolate the positive high-voltage output transformer/rectifier group from the feeder DC distribution bus. Disconnectors may have single or double poles. Double poles are used to disconnect the positive and the negative pole simultaneously. Operation may be motorized or manual. There are four different sizes: 19.75 in, 31.5 in, 47.25 in or 63 in. Incoming DS cubicles may contain up to 4 disconnectors. /// NEGATIVE DS CUBICLE Negative DS cubicles isolate the negative pole of the rectifier groups from the return current of the network (rail). Operation may be motorized or manual. There are four different sizes: 19.75 in, 31.5 in, 47.25 in or 63 in. Negative DS cubicles may contain up to 4 disconnectors. /// COUPLING DS CUBICLE Coupling DS cubicles subdivide the DC switchboard into separate busbar sections. Operation may be motorized or manual, size is 19.75 in. Disconnecting Switch cubicle Below are the different configurations according to the cubicle dimensions and types: Incoming DS cubicle Negative DS cubicle Coupling DS cubicle 2000 A - 1 pole 4000 A - 1 pole 6000 A - 1 pole 2000 A - 2 poles 4000 A - 2 poles 2000 A - 1 pole 4000 A - 1 pole 2200 6000 A - 1 pole 2000 A - 1 pole 4000 A - 1 pole 6000 A - 1 pole 500 1 1 1 1 1 1 1 1 1 1 1 Disconnecting Switch SWS 500 1400 800 2200 2 2 2 1 1 2 2 2 1 1 1 800 1400 1200/1600 2200 4 4 4 2 2 4 4 4 2 2 2 1200 1400 Disconnecting Switch SWS 6 DC Switchgear Range / Type MBS (IEEE/ANSI standards)

CONTROL AND PROTECTION RELAY SEPCOS is a protection and control unit that is applied to the outgoing feeder or the incoming HSCB cubicles in the DC traction substation. /// MAIN FEATURES Modular PLC concept, PLC programming, IEC 61131 normalized programming. Fully approved in railway substation environment IEC 60255-22. High noise immunity thanks to sampling rate at 40 microseconds and 16 bits A-D converter. /// PROTECTION FUNCTIONS All typical protection functions (e.g. DDL +/-, Imax +/-, etc.). /// CONTROL FUNCTIONS HSCB ON/OFF control with electric or magnetic holding. Intertripping, automatic reclosing, anti-pumping, load measurement. External synchronization of the PLC, measurement supervisor control. /// OPEN TO ALL CUSTOMER NETWORKS AND PROTOCOLS TCP/IP: Modbus-TCP. Specific TCP/IP based power distribution protocols: IEC 60870-5-104, IEC 61850, DNP 3.0. Fieldbus: Modbus-RTU, Profibus-DP. 1 SEPCOS may be controlled and parametrized through a user-friendly 7 color touch screen Display located on the front door of the cubicle. 2 All functions are available through a web-server (S-Web), including visualization of trends. 1 SEPCOS in a low-voltage compartment 2 STANDARDS According to IEEE Std. C37.20.1-2015 and IEC 60980 (Seismic tests). Approved type test reports available. Main features MBS 20 MBS 24 Rated voltage 800 VDC 1600 VDC 800 VDC 1600 VDC Rated service current 6000 A 6000 A 8000 A 8000 A Rated making & breaking capacity 120/200 ka 60/100 ka 120/200 ka 60/100 ka Duty classes a, b, c, d a, b, c, d a, b, c, d a, b, c, d Degree of protection IP42 IP42 IP42 IP42 INTERNAL ARC TEST Main features MBS 20 Rated voltage 900 VDC Rated insulation voltage 1800 V Prospective current under arcing conditions 50/71 ka Permissible arc duration 250 ms Degree of protection IP42 DC Switchgear Range / Type MBS (IEEE/ANSI standards) 7

SG839112BEN_A00-09.17 Sécheron SA Rue du Pré-Bouvier 25 1242 Satigny - Geneva CH-Switzerland www.secheron.com Tel: +41 (0)22 739 41 11 Fax: +41 (0)22 739 48 11 substations@secheron.com This document is not contractual and contains information corresponding to the level of technology at the date of printing. Sécheron reserves the right to modify and/or improve the product, whose characteristics are described in these documents, as required by new technology at any time. It is the purchaser s responsibility to inform himself, no matter what the circumstances, of the product s maintenance conditions and requirements. Sécheron reserves all rights, especially those arising from our General Delivery Conditions. Copyright 2017 Sécheron SA